HomeMy WebLinkAboutAPPROVED 05-20-2021 Sam Comer-FINAL05/27/2021 E-1 1 OF 2GENERATORADDITION RISERDIAGRAMNEW GENERATOR FOR:SAM COMER8590 GERMANY CANAL RD.FORT PIERCE, FL. 34987NTS 1 GENERATOR ADDITION RISER DIAGRAM DATEREVISIONMARKDATE: SHEET DATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911SCOPE OF WORK: ·RELOCATE ABANDONED AT&T BOX. ·EXISTING METER CAN GROUNDING ELECTRODE MAY REQUIRE TO BE SHIFTED TO MAKE ROOM FOR NEW ATS AND PANEL FEEDER FROM ATS. FIELD VERIFY IF REQUIRED. ·INSTALL 200AMP SE RATED ATS TO THE RIGHT OF EXISTING UTILITY METER CAN ON EXTERIOR WALL. ·RE-FEED INTERIOR PANEL FROM NEW ATS. SEPARATE NEUTRALS AND GROUNDS IN PANEL IF REQUIRED. ·INSTALL COLD WATER BOND FROM ATS TO NEAREST CU WATER PIPING. ·FORM AND POUR CONCRETE PAD FOR GENERATOR. UTILIZE 2"x10" FORM BOARDS. ·PROVIDE AND INSTALL (1) 24kW GENERAC GENERATOR. ·PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FROM ATS TO GENERATOR. WILL HAVE TO HAND TRENCH NEW CONDUIT FROM ATS TO GENERATOR. ·PROVIDE (2) LOAD SHED DEVICES PER SIZING DATA THIS SHEET. ·NEW LP TANK TO BE PROVIDED AND INSTALLED BY FERRELLGAS UNDER A SEPARATE PERMIT. ·NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPE OF WORK. EXISTING 200 AMP METER CAN 120/240 1Ø NEW 200 AMP GENERAC SE RATED ATS 100AMP BREAKER EXISTING (2) 5/8" X 8' CU GROUND RODS EXISTING 200 AMP PANEL NEW GENERATOR: AIR COOLED GENERAC 24KW GRADE GENERAL NOTES: 1. 2. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE. ATTIC ATTIC GRADE ELECTRICAL LEGEND: SURFACE MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD FLUSH MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD SURFACE MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD FLUSH MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD UTILITY METER CAN OR METER/MAIN COMBO UNIT GENERATOR AND GENERATOR PAD GAS STORAGE TANK SURFACE MOUNT AUTOMATIC TRANSFER SWITCH NON-FUSED DISCONNECT FUSED DISCONNECT 30AR NF 3R FRAME SIZE NEMA RATING NON FUSED 30AR 30AF 3R FRAME SIZE NEMA RATING FUSE SIZE CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION EXISTING 2"PVC UNDERGROUND SERVICE FEEDER EXISTING OVERHEAD SERVICE RISER, WEATHERHEAD, AND UTILITY FEEDERS EXISTING 1/2"PVC W/ (1) #4 BARE CU 2"PVC W/ (3) #4/0 THWN AL 2"PVC W/ (3) #4/0 THWN AL, (1) #6 THHN CU GROUND 1-1/4"PVC SLEEVE W/ GENERAC CABLE W/ (3) #3 THHN CU, (1) #8 THHN CU GROUND, (5) #14THHN CU 1-1/4"PVC W/ (3) #3 THHN CU, (1) #8 THHN CU GROUND 3/4"PVC W/ (7) #14 THHN CU 1/2"PVC W/ (1) #4 BARE CU A B C D E F G H I D POINT OF NEW CONNECTION EXISTING WATER LINE F (EXISTING)B AC ALTERNATING CURRENT A/C AIR CONDITIONING AFG ABOVE FINISHED GRADE AL ALUMINUM (CONDUCTOR) AHU AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AMP AMPERE AFCI ARC FAULT CIRCUIT INTERRUPTER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE C CONDUIT CU COPPER (CONDUCTOR) COVB CITY OF VERO BEACH DC DIRECT CURRENT DISC DISCONNECT EXIST EXISTING FPL FLORIDA POWER & LIGHT G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER IRC INDIAN RIVER COUNTY KVA KILOVOLT AMPERE KW KILOWATT MC METAL CLAD CABLE MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANELBOARD MTS MANUAL TRANSFER SWITCH MSB MAIN SWITCHBOARD MLO MAIN LUGS ONLY NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NTS NOT TO SCALE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NON-SE NON SERVICE ENTRANCE RATED PLCS PLACES (QUANTITY) PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT RMC RIGID METAL CONDUIT RTU ROOF TOP UNIT SE SERVICE ENTRANCE RATED TYP TYPICAL TEMP TEMPORARY TRANS, TX TRANSFORMER UG UNDERGROUND UL UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERE W WATT XFMR TRANSFORMER ABBREVIATIONS: NATURAL GAS METER NOTE: NOT ALL CONDUIT AND WIRE SHOWN ON THIS SCHEDULE MAY PERTAIN TO THIS PROJECT. (SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) INTERIOREXTERIOR INTERIOREXTERIOR EXTERIORINTERIOR EXTERIORINTERIOR FINISHED FLOOR C I GROUND ROD LOAD MANAGEMENT "LCM" LOAD SHED LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENT AND FREQUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). GENERAL NOTES: ·THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. ·THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE NFPA 70 (2017). ·ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. ·THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NATIONAL ELECTRICAL CODE NFPA 70, ARTICLE 110.26 SPACES ABOUT ELECTRICAL EQUIPMENT. ·PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. ·ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. ·GROUNDING PER NATIONAL ELECTRICAL CODE NFPA 70, ARTICLE 250 GROUNDING AND BONDING. ·STANDBY SYSTEM INSTALLATION PER NATIONAL ELECTRICAL CODE NFPA 70, ARTICLE 702 OPTIONAL STANDBY SYSTEMS, AND MANUFACTURER INSTALLATION INSTRUCTIONS. FROM NEW ATS E E ETO EXISTING PANEL F:\GENERATOR DRAWINGS\05-20-2021 Sam Comer\05-20-2021 Sam Comer.dwg, 5/27/2021 9:06:25 AM COVERED PATIO COVERED PATIO COVERED PATIO CONC. SLAB DRIVEWAY NEW 500 GAL. LP TANK (BY OTHERS) 15'-0"NEW UNDERGROUND GENERATOR FEEDER AND CONTROL CABLES NEW UNDERGROUND GENERATOR GAS LINE EXISTING UNDERGROUND GENERATOR GAS LINE EXISTING UTILITY METER NEW ATS EXISTING PANEL SINGLE FAMILY RESIDENCE 8590 GERMANY CANAL RD. FORT PIERCE, FL. 34987 OAK TREE 60'-0" 05/27/2021 2 OF 2GENERATORSITE PLAN &PAD DETAILDATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911DATEREVISIONMARKDATE: SHEET E-2 1/2" = 1'-0" 2 GENERATOR PAD DETAIL TOP VIEW LEFT ELEVATION FRONT ELEVATION DRILL DRILL 1/4" DEEPER THAN ANCHOR EMBEDMENT CLEAN DRIVE TIGHTEN 3-5 X DRILL BIT SIZE: 1/2"TIGHTENING TORQUE: 45ft.lbs. MIN. ANCHOR EMBEDMENT: 2-1/2" 1/4" MIN.54" 32" 10" MIN. 32"54" NOTE: UTILIZE 2"x10" FORM BOARDS. TOP OF GENERATOR PAD TO BE A MINIMUM OF 10"AFG 0'3"6"1'2' SCALE: 1/2" = 1'-0" NOTE: 1.THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI STANDARD B212.15 IS RECOMMENDED. 2.ANCHOR BOLTS TO BE 3/8"DIA.x3-3/4"LONG UNLESS OTHERWISE NOTED.NEW GENERATOR FOR:SAM COMER8590 GERMANY CANAL RD.FORT PIERCE, FL. 349871" = 10'-0" 1 GENERATOR SITE PLAN N W S E 0'2.5'5'10'20' SCALE: 1" = 10'-0"F:\GENERATOR DRAWINGS\05-20-2021 Sam Comer\05-20-2021 Sam Comer.dwg, 5/27/2021 9:03:29 AM