Loading...
HomeMy WebLinkAboutAPPROVED COMER SPECS20/22/24 kW INCLUDES: • True Power- Electrical Technology Two-line multilingual digital LCD Evolution' controller (Eng li sh/Spani sh/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor e Standard WI-Fi® connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation 0 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure.* 'Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. hops: //assels.swri, org/IibraryJDirectoryOfListedProducts/ Constructionlndustry/973_DoC 204_13204-01-01_Rev9.pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- erac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when it's needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER`" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINK° CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link WI-Fi allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAC 0 GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz G007042-2, G007043-2, G007042- 43�3,(Aluminum -Bisque) - 22 kW 60 Hz G0072 -0, G007210-0 trmjnum - Bisque) - 24 kW 60 Hz c E 1 I us or CLISTEDUS Note: CEL or CUL certification only agiles to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MAXI- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component, O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. O PWRVIEW' TRANSFER SWITCH: The Generac PWRview Automatic Transfer Switch integrates the PWRview energy monitor to provide real-time energy con- sumption data that can help lower a home's electricity bill. Using a convenient mobile app, homeowners can access energy usage and alert information while under utility power or generator power. The PWRview energy monitor is a simple to use and low cost tool which helps save money over the life of the generator. Included with model G007210-0. w GENERACQ@@0E pAGPROMISEPWRIM C � � 20/22/24 kW Features and Benefits Engine ♦ Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. ♦ "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. ♦ UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. PWRview Transfer Switch (if applicable) • PWRview energy monitor • Ability to view real-time energy consumption data • PWRview mobile app EvolutionT`" Controls • AUTO/MANUAl1OFF illuminated buttons • Two-line multilingual LCD • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Programmable exercise • Smart battery charger • Main line circuit breaker ♦ Electronic governor Energy usage at -a -glance. Better understand the home's energy profile. Access daily energy intelligence and insights. Selects the operating mode and provides easy, at -a -glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Smooth, weather -resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to verify the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Verifies engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. ENERAC® 20/22/24 kW Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. Installation System • 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6,27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month 's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 20/22/24 kW Specifications Generator Model 13007038-1 G007042-2 13007038�3 G0070424 13007209-0 G007039-1 G007043-2 13007039�3 G0070434 G007210-0 (20 kW) (22 kW) - (20 W) (22 kW) (24 IrW) Raiedmaxrmumcon8nucuspawercapaetty (!P T T 26,OQo-Viratts• 22000Watts rOT000W2ttsk 22Q(IOrNatts` 2�QWaOs Rated maximum continuous power capacity (NG) 18 000 Watts' 19,500 Watts 18 000 Watts' 19,500 Watts" 21,000 Watts' RatertYoltaga 24(b T 3 Rated maximum continuous load current - 240 volts (tP/NG) 83.3 / 75.0 91 7 / 81 3 83 3 / 75 0 91 7 / 81 3 100 / 87 5 �__.� - TotahHarmonicDistodlonessittan5 Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Number of rotor Doles 2 Power factor 1.0 BaitetrequtiemenY(nottnolruted) _ __ 1"Dolls group`26R54flCGA4nnimum=ar6oup35AGNr650'CC><trrftrvrfafm Unit weight (lb / kg) 448 / 203 466 / 211 436 / 198 445 / 202 455 / 206 :Dimensrons(CxWxftlinln ` _ , _ " __s_u _ _ v: 4&x,25429f12t9x635x73T Sound output in dB(A) at 23 it (7 m) with generator operating at normal load"` 67 67 67 67 67 :Soirndout01 4 do( A) at 23 i (rm) xnth generator m.0utef Tesk :law spaed exercise made _ : '=5 ___ r .'`7 Exercise duration 5 min . Engine Engine type GENERAC G Force 1000 Series .�r Note Fuel pipe�must be sueded for toll load. Required fuel pressure to generator fuel inlet at all Toad ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG,10-12 in water column (2.49-2.99 kPa) for gas. For BTU content, multiply ft /hr x 2500 (tP) or ft Jhr x 1000 (NG). far Megajoule content, multiply m3/hr x 93.15 (LP) or m'/hr x 37.26 (NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation FRbdebuttons AUTD _ = Auiomaticstartareuttit[yfariure Nleekty 8r weekly o Mar tilyselectahle:exerolser _ _ MANUAL `— — ..v._ >_ __. —. Start with starter control, unit stays on. If utility fads, transfer to load takes place. p� _ � „':Stopsumt:PowerisremuY,ed C'ofrftdkandehugersGlYoperattff_ - - -- Ready to Run/Maintenance messages Standard � Standard , ( pgina nor hwrsrndication Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) �i_ tlftyYNfagaLnss/€teiumtoUbbi�adtustailt�(hrnwriatrtsatUng) Future Set Capable on ma Set Error warning _ Standard AtuilNattrtdctarntenance.Gags> Engine start sequence Cyclic cranking 16 sec on 7 rest (90 sec maximum duration) Sta (ertoc rod,' Stadengagpatle engagi unOC secafterangrnefSasstappe�: _ Smart Battery Charger Standard — =Standard Charger 1 ault/Mi singpGuramm _ _ — _ Low Battery/Battery Problem Protection and Battery Condition radiation _ Standard AutortabcUol6�e>RegutatiorrvnlhOYeratjdUnd�ValtagsProleeti94� �_ _ __ _��__� u� _ <� Under Frequency/Overload/Stepper Overcurrent Protection Standard Automatic Low Oi Pressure/Fligh 011 Temperature Shutdown �� Standard f+ercrar/QaersPaed C7Hz)Crpmene LassShutdovarr_ _ _ r _ _ Shandardt High Engine Temperature Shutdown Standard Y _ — Internal FaUltltrtearrecfi Wtrinq¢ratechoir ": _ — ._ ._t. __ —_ av-.- _ .__ _ r SEanaT J Common external fault capability Standard '*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters, Rating definitions - Standby: Applicable or supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). *Maximum kilovolt amps and current are subject to and limited by such (actors as fuel BTUlmegajoule content, ambient temperature, altitude, engine power and condition, etc. Maxmum power decreases approximately 3.5%for each 1,0OO If (304.8 m) above sea level; and also will decrease approximately 1%far each 10 °F (6 °C) above 60 °F (16 °C). 20/22/24 kW Service Rated Automatic Transfer Switch Features • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for ail classes of Ioad,100%equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMANL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility Dimensions 200 Amps 120/240, ie Open Transition Service Rated Height Width pepth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76,43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 PWRview Automatic Transfer Switch Features • Integrated PWRview monitor provides real-time energy usage data through PWRview app. • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of Ioad,100%equipment rated, hoth inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibiliy. • Heavy duty Generac Contactor is an ETL recognized device. Dimensions 200 Amps 120/240,1a Open Transiticn Service Rated Height Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13,5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 Switch Options Model G007039.1, G007039-3 (20 kW) G007043.2, G007043.3 (22 kW) Current rating (amps) 200 =uoitage:ratin�(VAC� _ f i ___= 12Qj244 i?i s _„ Utility voltage monitor (Oxed)' -Pick-up 80% -Dropout 65% �etumto=ll0iy*__.��x�, v x�u_.___.___ ApPrt7x�3sec_�- _�_._� Exercises bi-weekly for 5 minutes' � Standard rE}itn�lirst� `,� �,-_._� u.._ .. _� SLui�rdE __. _,-..� _� Enclosure type NEMA/UL 3R �CireurLbreakecproiacte�.�;: �__:� _.,_...__ 1ZDDB _ _ _ Lug range 250 MCM - #6 *Function of Evolution controller Exercise can be set to weekly, bl-weekly, or monthly Model Current ratinc (amps) 20D Utility voltage monitor (fixed)' -Pick-up 80% -Dr000ut 65% Exercises bi-weekly for 5 minutes' Standard =aruU�,li�sted� _ � � _5tanoar�_ -, �.N= . �" �._ �. Enclosure tune NEMA 3R Lug range 250 MCM - #6 *Function of Evolution controller Exercise can beset to weekly, bi-weekly, or monthly 20/22/24 kW Model UPC G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 G007209-0 696471071511 G007210-0 696471078220 LEFT SIDE VI EW Available Accessories Dimensions & UPCs FRONT VIEW Dimensions shown are appropmate. See installaflon manual far exact dimensions. 00 NOT USETNESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2020 Generac Power Systems, Inc. All dghts reserved. All specifications are subject to change without notice. Part No. A0000937814 Rev. B 07/30/2020