Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit #: • Q)`-I C'?
Job Information
Builder: K Hovnanian Community: Lot:
Address: �-. Unit.
City: �p t� , �+�C" State: FL Zip:
House S.F. Avg. Ceiling Height: Total Volume:
04
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive; or ERR Method
P�t�SC�t1�iiV� METFi�?D � The building or owe€ling unit she€€ lee tested and ver€f€ed as having �n air leakage rate or not ex�eeding 7 air
change' per hour at a pressure of 0.2"Inch w.g. (50 pascals) in climate zones 1 and 2.
PERFORMANCE
OR ERI METH QD '-The building or dwelling unit shah be tested -and verified as hav€ng an air leakage rate of not
exceeding the selected ACH(50) value, as shown on FORM 14405-2017 (Performance) or 11406-2017 (ERI), section labeled as Infiltration, sub
section ACH.
ACH(50) specified on Form 1?405M2017-Energy Cale (Performance) or R406�2017 (ERI):
Pressure &Flow Data (For Single Point)
ACH50 = CFM (50) x 60 /House Volume =
[PASS ❑ FAIL
❑ When ACH(50) is less than 3, Mechanical Ventilation installation must
be verified by building department.
Method for caicufatini~ building volume:
Retrieved from architectural plans
Code Software calculated
Field measured and calculated.
pg, Testing shall be conducted in accordance with ANSlf RESNETJICC 380 and reported at a pressure inch w,g. (Sp pascals). Testingng shall be
conducted by eitherindividual as defined irrSectidn s'a�,903(S} or (7�, �laricltr Statues, or individuals licensed asset faith in Section 4��,�.OSt3}(fh {gj,or (i} or`
an approved third party, A written report of the results of the test shall be signed by the party conducting the test and provided to the code official, Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope,
Testing
Company
Company Name: RunBrook, LLC Phone: 561-510-5715
hereby verify that the above Air Leak 'e results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirementa)(Zorclirg'V the compliance method selected above.
Signature of Tester:
Printed Name of Tester: rank Costagliola
License/Certification #:
3243649
Date of Test: 7 1)ei Id
Issuing Authority: RESNET
RUNBROOK
Duct Leakage Test Report
GREEN BUILDING Imo. ENERGY TESTING.
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
jurisdiction: Permit #:�� -- b �7 6'
,fob Information
Builder: K Hovnanian Community: �S Lot:
Address: Unit:
City:- le r State: FL Zi p:
Duct` Leakage Test Results
System 1 0 Prescriptive Method cfm25 (Total)
cfm25
To qualify as "substantially leak free" Qn must be less than or equal to
System 2 0.04 if air handler unit is installed. If air handler unit is not installed,
cfm25 Qn Total must be less than or equal to 0,03, This testing method
System 3 meets the requirements in accordance with Section R403.3.3.
cfm25
um of any
additional systems -- cfm25
Performance / ERI Method cfm25 (out or Total)
Total of all C� To qualify using this method, Qn must not be greater than the
systems cfm25 proposed duct leakage Qn specified on Form R405-2017 or R40&2017,
r\ _ �`'�
Qn LeakageType e selected on Form Qn specified on Form R405-2014
Total of all or Total Conditioned yP
systems Square Footage R405-2017 (Energy Calc) or R406-2017 (Energy Calc) or 40&2017
PASS FAIL
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553,993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes,
Testing Company`
Company Name: RunBrook, LLC Phone: 561-51M715
I hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements according to the compliance method selected above,
61)
Signature of Tester: Date of Test: <7C
Printed Name of Tester:
Frank Costagliola