HomeMy WebLinkAboutAPPROVED Re-Roof Forms ST. LUCIE WORK,'-;-
Section A (General information)
Master Permit No. Process No.
Contractors Name: Total Home Roofing License# CM 330489
Job Address 0,91,,d.LLll1_i ZaQ P—
ROOF CATEGORY
Slope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles
sphaltic Shingles 0 Metal Panel/Shingles Mood Shingles/Shakes
13 Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
0 New roof 13 Repair 13 Maintenance Reroofing Cl Recovering
.ROOF SYSTEM INFORMATION
Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF)
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets,
I
I
I � !
t
t
7/16/2021 29357_32342_1.jpg(800.800)
�F
BAS
(18D
URAA 1
(120)
BAS 3
12 (1345 :
1
20 CPAA
(240)
5
5 OPA4.
19D
https://www.paslc.org/ImageSketches/sketch/29/29357_32342_l.jpg 1/1
ST. LUCIE WORKS
Section C(Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':—"oc @ Lap,#Rows—®_oc
(If a component is not used,identify as"NA") Zone 1:_." oc @ Lap,#Rows_®_ac
System Manufacturer: C@rtainteed Zone 2:_"oc @ Lap,#Rows—®'ao
Product Approval No.: FL2533-R24 Zone 3:_"oc @ Lap,#Rows—0'00
Number of Fasteners Per Insulation Board:
Design Wind Pressures,From RAS 128 Or Calculations: Zone 1':--Zone 1: one 2:_Zone 3:_
Zone 1':-34.6 Zone 1:: 0 Zone 2: Zone 3'1a4 Illustrate Components Noted and Details as Applicable:
Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: -127.5 Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashin&Coping,Etc. ..
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: Wood Flashing,Component Material,Material'Thickness,Fastener
++ Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: �8 Comply with RAS 111 and Chapter 16..
Slope:06d--
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT'
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer: Flintlastic
Top Insulation Size and Thickness: Flintlastic FT.
Top Insulation Fastener/Bonding Material: 1 5'
Mean
Base Sheet(s)&No.of Ply(s): Flintlastic Roof
Base Sheet Fastener/Bonding Material: Drip Edge:3"X 3"GalvAlum Height
SA
Ply Sheet(s)'&No.of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Flintlastir.
Top Ply Fastener/Bonding Material:
( SA
ST. LUCIE WORKS
Section D(Steep Slope Roof System)
Roof System Manufacturer: Owens Corning
Notice of Acceptance Number:
FL10674-R16
Minimum Design Wind Pressures,If Applicable(From RAS 127 or calculations):
Zone 1:'2�one 2e:'Z�one 2n-108one 2rr108 one 3erl�one 3r:128
DwkTyM: Wood
Type Undedayment
Roof Sbpe:
12 Insulation: N/A
Fire Barrier: N/A
1 1/4"Ring hank ails
Rid a f1 Fastener Type &Spacing: a'nr. I apc 19"nr. Fluid
Adhesive Type: N/A
Type Cap Sheet N/A
Mean RoofHeigM: 1 �' Roof Covering: I Asphalt Shingles
Type& Size Drip 3" X 3" Galy Alum
Edge: