HomeMy WebLinkAboutBLOWER DOOR TEST, DUCT LEAKAGEEnvelope Leakage Test Report
(Blower Door Test)
R402.4.1.2 Compliance
Permit
Job Information
Builder: DR HORTON Community: �e Lot: 41
Address: ? 1, ,. Unit:
City: aState: FL Zip:
Air Leakage Test Results Passing results must be 7ACH(50) or less
X 60 ' 1 -3 Method for calculating building volume:
CFM(50) Building Volume ACH(50) Retrieved from architectural plans
O Code software calculated
PASS L] FAIL
0 Field measured and calculated
When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department.
Certification of Test Results
R1107_a_1 _7 Tectina Th. k.61,jin r J,., u; . �; L n _
_ _...1. .., b ",,,,b u,,,Lai a,. ua 0:raLeu ana vennea as naving an air leakage rate of not exceeding 7 air changes
per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a
pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or
individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. A written report of the results of the test
shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at anv time after crP;;f nn of
all penetrations of the building thermal envelope.
Testing Company
Company Name: SUN SEAL LLC Phone: 321-412-0035
1 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: 11 Z . 1 'Z,-7Y
Signature of Tester:
Printed Name of Tester: RAULY BAGGETT
License/Certification # 506619S Issuing Authority BPI
Duct Leakage Test Report
Prescriptive or Performance Method
Permit #
Job Information
Builder: DR HORTON Community: Ge r Lot: ty
Address: ) ttc `�_ C, Unit: f j
City: + P;e r State: FL Zip:
Duct Leakage Test Results O Presciptive Method 0 Performance Method
System 1
System 2
System 3
Sum of any additional
systems
Total of all systems
Total of all systems
ASS
Testing Company
Total Conditioned
Square Footage
El FAIL
i
cfm25 Q Prescriptive Method cfm25 (total)
To qualify as "substantially leak free" Qn must be less than or equal to 0.04
cfm25 if air handler unit is installed. If air handler unit is not installed, On Total
must be less than or equal to 0.03. This testing method meets the
cfm25 requirements in accordance with Section R403.2.2
cfm25
cfm25
0 Performance Method cfm25 (Out or Total)
To qualify as "substantially leak free" Qn must not be greater than the
proposed duct leakage Qn specified on Form R405-2014
Leakage Type selected
on Form R405-2014
(Energy Catc)
Qn specified on Farm
R405-2014 (Energy Caic)
Company Name: SUN SEAL LLC Phone: 321-412-0035
1 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: —11 '2 6 120 - f
Signature of Tester: I 01 %
Printed Name of Tester: RAULY BAGGETT
License/Certification # 5066185 Issuing Authority