HomeMy WebLinkAbout56-SF-2085570 FinalSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: Artemio & Ana Rosa Reyes Resendiz
AGENT: Karner Surveying, Inc
PROPERTY ADDRESS: 4413 Pressler Ln Fort Pierce, FL 34982
APPLICATION #:AP1505989
PERMIT #:56-SF-2085570
DOCUMENT # : F 11664354
DATE PAID.05/22/2020
FEE PAID:545.00
RECEIPT #:56-PID-4415370
LOT: 1 & 2
SUBDIVISION:
BLOCK: 1
Cardinal Glades ID#: 2434-802-0001-000-8
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH
STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ]
[01]
TANK SIZE [11 1090.00 [2]
[ ] [27]
SURFACE WATER
FT
[ ]
[021
TANK MATERIAL Polypropylene
[ ] [28]
DITCHES 49
FT
[ ]
[031
OUTLET DEVICE
[ ] [291
PRIVATE WELLS 93
FT
[ ]
[04]
MULTI -CHAMBERED [LYj N ]
[ ] [301
PUBLIC WELLS
FT
[ ]
[051
OUTLET FILTER Polylok PL-68
[ ] [311
IRRIGATION WELLS
FT
[ ]
[06]
LEGEND 1. 70-143-11DC4 2.
[ ] [321
POTABLE WATER 80
FT
[ ]
[07]
WATERTIGHT
[ ] [331
BUILDING FOUNDATIONS 6
FT
[ ]
[08]
LEVEL
[ ] [34]
PROPERTY LINES 37
FT
[ ]
(091
DEPTH TO LID
[ ] [35]
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ]
[10]
AREA [1) 679 [2] SQFT
[ ] [36]
DRAINFIELD COVER
[ ]
[11]
DISTRIBUTION BOX HEADER X
[ ] [37]
SHOULDERS
[ ]
[12]
NUMBER OF DRAINLINES 1. 6.00 2.
[ ] (38]
SLOPES
[ ]
[131
DRAINLINE SEPARATION
[ ] [391
STABILIZATION 07/20/2021
[ ]
[141
DRAINLINE SLOPE
[ ]
[15]
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ]
[161
ELEVATION [ ABOVE / BELOW ]BM 16,00
[ ] [401
UNOBSTRUCTED AREA
[ ]
[17]
SYSTEM LOCATION
[ ] [41]
STORMWATER RUNOFF
[ ]
[18]
DOSING PUMPS
[ ] (42]
ALARMS
[ ]
[191
AGGREGATE SIZE
[ ] [43]
MAINTENANCE AGREEMENT
[ ]
[201
AGGREGATE EXCESSIVE FINES
[ ] [44]
BUILDING AREA
[ ]
[211
AGGREGATE DEPTH
[ ] [45]
LOCATION CONFORMS WITH SITE PLAN
FILL
/ EXCAVATION MATERIAL
[ ] [461
FINAL SITE GRADING
[ ]
[221
FILL AMOUNT
[ ] [47]
CONTRACTOR MICHAEL STUHR (ASHTON
[ ] [48]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ]
[231
FILL TEXTURE
[ ]
(24]
EXCAVATION DEPTH
ABANDONMENT
[ ]
[25]
AREA REPLACED
[ ] [491
TANK PUMPED
[ ]
[26]
REPLACEMENT MATERIAL
[ ] [50]
TANK CRUSHED & FILLED
Comments: Comments
are on page 2.
CONSTRUCTION I APPROVED / L t. Lucie CHD DATE: 05/05/2021
DISAPPROVE Environmental S eciali t II Ni ole Montan z Department of He
FINAL SYSTEM [ AppROVED / DISAPPROVED ]: St. Lucie CHD DATE: 07/20/2021
nVironmental Specialist I Matt S ny (Florida Department of H
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1505989 EID2085570
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION #:AP1505989
PERMIT #:56-SF-2085570
DOCUMENT # : FI 1664354
DATE PAID.05/22/2020
FEE PAID:545.00
RECEIPT #:56-PID-4415370
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, filter, and 6x10 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final
inspection for mound system, and final site grading.
Final inspection completed. Mound system checked and final site grading completed.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1505989 EID2085570