Loading...
HomeMy WebLinkAboutWeldDeckCerts2021NDT NON DESTRUCTIVE TESTING GROUP 8181 Broadznoor St. Caledonia, MI. 49316 WELDER AND WELDING OPERATOR QUALIFICATION TEST RECORD Welders Name Matthew ODonnell Identification No. 0-546 Qualification Date 01/10/21 Welders S/S No. 592-74-1045 In Accordance with WPS No. 006 Revision 0 Welding Process (es) SMAW Type Manual Mode of Transfer for GMAW N/A RECORD ACTUAL VALUES Variable Used in Qualification Qualification Range JOINT Joint Type Are Spot Arc Spot / Seam Backing Material Type Structural Structural Groove Welded from: One side or both sides NA NA BASE METAL (4.7.1.1) Material Spec. Sheet Steel A446 Gr. A A446 Gr. A Supporting Steel A570 A570 Groove NA NA Fillet NA NA Are Plug NA NA Arc Spot .1046" .1046" Arc Seam NA NA COATING (S) Type None NA Thickness None NA POSITION (4.7.1.5 & 4.7.1.6) Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot Flat Flat Arc Seam NA NA Progression NA NA ELECTRODE (4.7.1.3 & 4.7.1.4) Size NA NA Group Designation NA NA VISUAL EXAMINATION RESULTS (4.6) Specimen 1 PASS Specimen 2 PASS Appearance PASS Cracks NONE Undercut NONE Reinforcement <1/16" Diameter of Arc Spot Nugget 1/2" Test Conducted By Frank Minerro Per Non -Destructive Testing Group Inc. Laboratory Test No. OOC-25097 Date of Test 01/10/21 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance With the requirements of section 4.6 of ANSI / AWS D1.3 — (98). Structural Welding Code — Sheet Steel. Company: Accurate Welding Services LLC Authorized By Carol Smith NDT NON DESTRUCTIVE TESTING GROUP 8181 Sroadmoor St. Caledonia, MI. 49316 WELDER AND WELDING OPERATOR QUALIFICATION TEST RECORD Welders Name Gerald Quinones Identification No. Q-541 Qualification Date 01/10/21 Welders S/S No. 157-68-0069 In Accordance with WPS No. 006 Revision 0 Welding Process (es) SMAW Type Manual Mode of Transfer for GMAW N/A RECORD ACTUAL VALUES Variable Used in Oualification Qualification Range JOINT Joint Type Are Spot Arc Spot / Seam Backing Material Type Structural Structural Groove Welded from: One side or both sides NA NA BASE METAL (4.7.1.1) Material Spec. Sheet Steel A446 Gr. A A446 Gr. A Supporting Steel A570 A570 Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot .1046" .1046" Arc Seam NA NA COATING (S) Type None NA Thickness None NA POSITION (4.7.1.5 & 4.7.1.6) Groove NA NA Fillet NA NA Are Plug NA NA Arc Spot Flat Flat Arc Seam NA NA Progression NA NA ELECTRODE (4.7.1.3 & 4.7.1.4) Size NA NA Group Designation NA NA VISUAL EXAMINATION RESULTS (4.6) Specimen 1 PASS Specimen 2 PASS Appearance PASS Cracks NONE Undercut NONE Reinforcement <1/16" Diameter of Arc Spot Nugget 1/2" Test Conducted By Jose Perez Per Non -Destructive Testing Group Inc. Laboratory Test No. OOC-25106 Date of Test 01/10/21 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance With the requirements of section 4.6 of ANSI / AWS D1.3 — (98). Structural Welding Code — Sheet Steel. Company: Accurate Welding Services LLC Authorized By Carol Smith NDT NON DESTRUCTIVE TESTING GROUP 8181 Broadmoor St. Caledonia, MI. 49316 WELDER AND WELDING OPERATOR QUALIFICATION TEST RECORD Welders Name Joshua Britto Identification No. B-539 Qualification Date 01/10/21 Welders S/S No. 590-06-7334 In Accordance with WPS No. 006 Revision 0 Welding Process (es) SMAW Type Manual Mode of Transfer for GMAW N/A RECORD ACTUAL VALUES Variable Used in Qualification Qualification Range JOINT Joint Type Are Spot Arc Spot / Seam Backing Material Type Structural Structural Groove Welded from: One side or both sides NA NA BASE METAL (4.7.1.1) Material Spec. Sheet Steel A446 Gr. A A446 Gr. A Supporting Steel A570 A570 Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot .1046" .1046" Arc Seam NA NA COATING (S) Type None NA Thickness None NA POSITION (4.7.1.5 & 4.7.1.6) Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot Flat Flat Are Seam NA NA Progression NA NA ELECTRODE (4.7.1.3 & 4.7.1.4) Size NA NA Group Designation NA NA VISUAL EXAMINATION RESULTS (4.6) SSpecimen 2 PASS Specimen 1 PASS Appearance PASS Cracks NONE Undercut NONE Reinforcement <1/16" Diameter of Arc Spot Nugget 1/2" Test Conducted By Jose Perez Per Non Destructive Testing Group Inc Laboratory Test No. OOC-25092 Date of Test 01/10/21 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance With the requirements of section 4.6 of ANSI / AWS D1.3 — (98). Structural Welding Code — Sheet Steel. Company: Accurate Welding Services LLC Authorized By Carol Smith NDT NON DESTRUCTIVE TESTING GROUP 8181 Broadmoor St. Caledonia, MI. 49316 WELDER AND WELDING OPERATOR QUALIFICATION TEST RECORD Welders Name Raymond VanLuvender Identification No. V-540 Qualification Date 01/10/21 Welders S/S No. 038-46-8068 In Accordance with WPS No. 006 Revision 0 Welding Process (es) SMAW Type Manual Mode of Transfer for GMAW N/A RECORD ACTUAL VALUES Variable Used in Qualification Qualification Range JOINT Arc Spot Arc Spot / Seam Joint Type Backing Material Type Structural Structural Groove Welded from: One side or both sides NA NA BASE METAL (4.7.1.1) Material Spec. A446 Gr. A A446 Gr. A Sheet Steel 570 Supporting Steel Groove NA NA A N NA Fillet NA NA Arc Plug NA NA Are Spot .1046" .1046" Arc Seam NA NA COATING (S) None NA Type Thickness None NA POSITION (4.7.1.5 & 4.7.1.6) Groove NA NA Fillet NA NA Arc Plug NA NA Are Spot A Flat Flat Arc Seam NA NA Progression NA NA ELECTRODE (4.7.1.3 & 4.7.1.4) Size NA NA Group Designation NA NA VISUAL EXAMINATION RESULTS (4.6) Specimen 1 PASS Specimen 2 PASS Appearance PASS Cracks NONE Undercut NONE Reinforcement <1/16" Diameter of Arc Spot Nugget 1/2" Test Conducted By Jose Perez Per Non -Destructive Testing Group Inc. Laboratory Test No. OOC-25093 Date of Test 01/10/21 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance With the requirements of section 4.6 of ANSI / AWS D1.3 — (98). Structural Welding Code — Sheet Steel. Company: Accurate Welding Services LLC Authorized By Carol Smith NDT NON DESTRUCTIVE TESTING GROUP 8181 Sroadmoor St. Caledonia, MI. 49316 WELDER AND WELDING OPERATOR QUALIFICATION TEST RECORD Welders Name William Ledley Identification No. L-542 Qualification Date 01/10/21 Welders S/S No. 262-79-1130 In Accordance with WPS No. 006 Revision 0 Welding Process (es) SMAW Type Manual Mode of Transfer for GMAW N/A RECORD ACTUAL VALUES Variable Used in Qualification Qualification Range JOINT Joint Type Arc Spot Arc Spot / Seam Backing Material Type Structural Structural Groove Welded from: One side or both sides NA NA BASE METAL (4.7.1.1) Material Spec. Sheet Steel A446 Gr. A A446 Gr. A Supporting Steel A570 A570 Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot .1046" .1046" Are Seam NA NA COATING (S) Type None NA Thickness None NA POSITION (4.7.1.5 & 4.7.1.6) Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot Flat Flat Arc Seam NA NA Progression NA NA ELECTRODE (4.7.1.3 & 4.7.1.4) Size NA NA Group Designation NA NA VISUAL EXAMINATION RESULTS (4.6) Specimen 1 PASS Specimen 2 PASS Appearance PASS Cracks NONE Undercut NONE Reinforcement <1/16" Diameter of Arc Spot Nugget 1/2" Test Conducted By Jose Perez Per Non Destructive Testing Group Inc. Laboratory Test No. OOC-25095 Date of Test 01/10/21 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance With the requirements of section 4.6 of ANSI / AWS D1.3 — (98). Structural Welding Code — Sheet Steel. Company: Accurate Welding Services LLC Authorized By Carol Smith NDT NON DESTRUCTIVE TESTING GROUP 8181 8roadznoor St. Caledonia, MI. 49316 WELDER AND WELDING OPERATOR QUALIFICATION TEST RECORD Welders Name Leon Cundiff Identification No. LC-543 Qualification Date 12/28/20 Welders S/S No. 423-39-4744 In Accordance with WPS No. 006 Revision 0 Welding Process (es) SMAW Type Manual Mode of Transfer for GMAW N/A RECORD ACTUAL VALUES Variable Used in Qualification Qualification Range JOINT Joint Type Arc Spot Arc Spot / Seam Backing Material Type Structural Structural Groove Welded from: One side or both sides NA NA BASE METAL (4.7.1.1) Material Spec. Sheet Steel A446 Gr. A A446 Gr. A Supporting Steel A570 A570 Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot .1046" .1046" Arc Seam NA NA COATING (S) Type None NA Thickness None NA POSITION (4.7.1.5 & 4.7.1.6) Groove NA NA Fillet NA NA Arc Plug NA NA Are Spot Flat Flat Arc Seam NA NA Progression NA NA ELECTRODE (4.7.1.3 & 4.7.1.4) Size NA NA Group Designation NA NA VISUAL EXAMINATION RESULTS (4.6) Specimen 1 PASS Specimen 2 PASS Appearance PASS Cracks NONE Undercut NONE Reinforcement <1/16" Diameter of Arc Spot Nugget 1/2" Test Conducted By Jose Perez Per Non -Destructive Testing Group Inc Laboratory Test No. OOC-25096 Date of Test 12/28/20 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance With the requirements of section 4.6 of ANSI / AWS D1.3 — (98). Structural Welding Code — Sheet Steel. Company: Accurate Welding Services LLC Authorized By Carol Smith NDT NON DESTRUCTIVE TESTING GROUP 8181 Sroadmoor St. Caledonia, MI. 49316 WELDER AND WELDING OPERATOR QUALIFICATION TEST RECORD Welders Name David Mendez Identification No. DM-544 Qualification Date 12/28/20 Welders S/S No. 593-31-2775 In Accordance with WPS No. 006 Revision 0 Welding Process (es) SMAW Type Manual Mode of Transfer for GMAW N/A RECORD ACTUAL VALUES Variable Used in Qualification Qualification Range JOINT Joint Type Arc Spot Arc Spot / Seam Backing Material Type Structural Structural Groove Welded from: One side or both sides NA NA BASE METAL (4.7.1.1) Material Spec. Sheet Steel A446 Gr. A A446 Gr. A Supporting Steel A570 A570 Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot .1046" .1046" Arc Seam NA NA COATING (S) Type None NA Thickness None NA POSITION (4.7.1.5 & 4.7.1.6) Groove NA NA Fillet NA NA Arc Plug NA NA Arc Spot Flat Flat Arc Seam NA NA Progression NA NA ELECTRODE (4.7.1.3 & 4.7.1.4) Size NA NA Group Designation NA NA VISUAL EXAMINATION RESULTS (4.6) Specimen 1 PASS Specimen 2 PASS Appearance PASS Cracks NONE Undercut NONE Reinforcement <l/16" Diameter of Arc Spot Nugget 1/2" Test Conducted By Jose Perez Per Non -Destructive Testing Group Inc Laboratory Test No. OOC-25102 Date of Test 12/28/20 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance With the requirements of section 4.6 of ANSI / AWS D 1.3 — (98). Structural Welding Code — Sheet Steel. Company: Accurate Welding_ Services LLC Authorized By Carol Smith