Loading...
HomeMy WebLinkAboutAPPROVED Boral Estate NOAMIAMI•DADE COUNTY MIAMI-PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.g2L/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Estate "S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 19-1021.03 and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Semino NOA No. 21-0107.03 CMLAWD�ADE COUNTY Expiration Date: 08/23/21 ' " • ' Approval Date: 03/04/21 Page 1 of 9 ROOFING ASSEMBLY APPRovAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Estate "S" Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Applicant Boral Estate `S' Roof Tile Length = 16-1/2" Width = 13" Trim Pieces 1= varies w = varies varying thickness 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL Test Product Specifications Description TAS 112 Low profile, interlocking, extruded Type lb concrete roof tile equipped with two nail Class III hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. TAS 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BONDTM Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Touch `N Seal StormBone 2 Two- Two component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive MIAMNDADE COU �gn...• l Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. DuPont de Nemours, Inc. DAP Foam, Inc. NOA No. 21-0107.03 Expiration Date: 08/23/21 Approval Date: 03/04/21 Page 2 of 9 2.3 EVIDENCE SUBMITTED: Test Agency Test Identifier Test NamerKepor[ Dnty Redland Technologies 7161-03 PA 102 Dec. 1991 7161-03 PA 102(A) Dec. 1991 7161-03 PA 108 Dec. 1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, 1994 PA 108 Aug. 1994 Professional Service 224-47099 PA 112 Sept. 1994 Industries, Inc. The Center for Applied 94-060B PA 101 March, 1994 Engineering, Inc. 94-084 PA 101 May 1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 PA 102 Oct. 1994 25-7094-4 PA 102 Oct. 1994 Project No. 307025 PA 100 Oct. 1994 Test #MDC-76 25-7183-1 PA 102 Feb. 1995 25-7183-2 PA 102 Feb. 1995 25-7214-2 PA 102 March, 1995 25-7214-6 PA 102 March, 1995 Celotex Corporation Testing 528454-2-1 PA 101 Sep. 1998 Services 520109-2 Dec. 1998 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 IBA Consultants, Inc. 2381-264 TAS 112 01/08/08 American Test Lab of South RT1210.03-15 TAS 112 12/17/15 Florida PRI Construction Material DAPF-004-02-05 TAS 101 07/26/18 Technologies DAPF-004-02-07 Static Uplift Resistance 07/26/18 (Adhesive Set) NEMO ETC, LLC 4c-DPBS-20-LSOTM-01.C.R1 TAS 101 12/17/20 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set file applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Minimum slope 4/12 for mechanically attached tile. NOA No. 21-0107.03 Expiration Date: 08/23/21 Approval Date: 03/04/21 Page 3 of 9 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications_ Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Boral Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length -I (ft.) Width-w (ft.) Boral Estate `S' Roof Tile 10.0 1.375 1.08 Table 2: Aerodynamic Multipliers - X (ft) Tile Profile X (ft3) Batten Application X (ft3) Direct Deck Application Boral Estate 'S' Roof Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M9 (ft.-lbf) Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Boral Estate `S' Roof Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck N/A 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" plywood) (min. 19/32" plywood) Boral Estate 2-10d Ring Shank Nails 27.8 37.4 28.8 `S' Roof Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail2 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw2 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Cli 2 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail Eave Cli 2 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails Field Clip) NOA No. 21-0107.03 Expiration Date: 08/23/21 Approval Date: 03/04/21 Page 4 of 9 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nails Eave Cli T_ J I 2-10d Ring Shank Nails 43.0 67.5 50.9 1 Installation with a 4" the headlap and fasteners are located a min. of 2'/2" from head of tile. 2 When using only one fastener use the hole that is approximately 4-3/4" away from interlocking edge. Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Boral Estate `S' Roof Tile Adhesive 3 See manufactures component approval for installation requirements. 4 Dupont de Nemours, Inc, TILE BONDT"' Roof Tile Adhesive weight per patty 8 grams. * SEE NOTE* 2a 35 5 ICP Adhesives and Sealants, Inc, ICP Adhesve Polyset0 AH-160 two -component foam weight per patty 8 grams 26.1 6 DAP Foam, Inc. Touch `N Seal StormBond° 2 Two -Component Polyurethane Roof Tile Adhesive two -component foam weight per paddy $ grams. 35 7 Dupont de Nemours, TILE BONDTM Roof Tile Adhesive weight per patty 16 grams. 67 * SEE NOTE* 2b *NOTE* SEE 2A- page 8 of 9 for details/data. SEE 2b- page 9 of 9 for details/data. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Boral Estate `S' Roof Adhesive? Tile 8 See manufactures component approval for installation requirements. 9 ICP Adhesives and Sealants, Inc, ICP Adhesve Polyset0 AH-160 two -component foam weight per patty 54 grams. 86.6 10 ICP Adhesives and Sealants, Inc, ICP Adhesve PolysetO AH-160 two -component foam weight per patty 24 grams 45.5 11 DAP Foam, Inc.Touch `N Seal StormBond° 2 Two -Component Polyurethane Roof Tile Adhesive 60 two -component foam weight per paddy 60 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf) for Mortar or Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Boral Estate `S' Roof Mortar Set 20.6 Tile NOA No. 21-0107.03 MIAMMADE CO Expiration Date: 08/23/21 Approval Date: 03/04/21 Page 5 of 9 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". No z BORAL ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No. 21-0107.03 Expiration Date: 08/23/21 Approval Date: 03/04/21 Page 6 of 9 Nail Holes PROFILE DRAWING BORAL ESTATE "S" CONCRETE ROOF TILE 9 NOA No. 21-0107.03 MIAMI•DADE COUNTY Expiration Date: 08/23/21 • • Approval Date: 03/04/21 Page 7 of 9 Set No.:I2a Photograph wn� Interdependent: Two (2) beads/paddys,' Attachment: minimum 1" x 1" x 8" minimum contact area l of 16 ir,* each Type SET 2A Paddy Minimum I Attachment Min. Tile Contact) Characteristic Resistance Expresseo Placement Area, in' per Tile ' Resistance force, Ibf as a Moment, ft-Ibf Attachment: Two l2) beads/paddys, Interdependent mir rIum 1- n. x 1-in. x 8-in. 32 33 35 Adhesive Rates: 8 gram/paddy $ORAL ESTATE "S" CONCRETE ROOF TILE NOA No. 21-0107.03 MIAMWADE COUNTY Expiration Date: 08/23/21 •I Approval Date: 03/04/21 Page 8 of 9 I Edependent: Two (2) beads/paddys, rninimum 2" x 2" x 4", starting V back from Attachment. - head of Underlying tile, minimum contact area of 8 inI each Own SET 2B 4b Paddy I Minimum 11 Attachment Min, Tile Contact Characteristic Resistance Expressed Type Placement Area, in :perTile Resistance Force, Ibf[as a Moment, ft•lbf i I Attachment: Two (2) beads/paddys, minimum 2-+n. x 2-in. x 4"in., starting Incirprr nt 1" bdck from head of underlying the Adhesive Rates: 16 gram/paddy 61 $ORAL ESTATE " S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE 67 NOA No. 21-0107.03 MIAMI-DADE COUNTY Expiration Date: 08/23/21 "' • ' Approval Date: 03/04/21 Page 9 of 9