HomeMy WebLinkAboutAPPROVED Hip & Ridge Attachment -TRI 'EDITION
STMJCT+JRF DRIP AND RIDGE SUPPORT FHW-17
OPTIONS:METAL,WOOD AND PLASTIC
1
Underlayment Approved for Wood Hip and Ridge Support Attachment
Adhesive Applications with Code Approved Roof Tile Adhesive zz
Metal Hip and Ridge Support
Frame Installed as per the
Manufacturer's Product Approval
i
Plastic Ridge Support Used in
Conjunction with Code Approved
Roof Tile Adhesive
Seal All Nail Penetrations with Compatible Roof Cement
Unless the Underlayment Meets ASTM D-1970 Sec.7.9.
Note:Stacking of Nailer Boards may be Used.Maximum Thickness of 2"per Additional Nailer Board.
STRUCTURE HIP AND RIDGE SUPPORT FHW-18
OPTION:CODE APPROVED PRE-BAGGED MORTAR
Point Mortar to Desired Finish
Install Hip and Ridge Tile in a Continuous Bed of Code
Approved Pre-Bagged Mortar.Mortar Shall Completely Fill the
Entire Cavity and Provide a Bond with the Hip and Ridge Tile.
J Note:SSTD 11-99 Code Compliant
Documentation shall be provided when
a continuous bed of code approved pre-
bagged mortar is used for structural
support in the installation of hip and ridge
roof tile.
NOTE—Drawings are for illustrative purposes and do not reflect all methods of installation. Please refer to written text.
FRSA-TRI Florida High Wind Concrete and Clay Tile Installation Manual-6th Edition 12/31/20