HomeMy WebLinkAboutBuilding Permit Application All APPLICABLE INFO UST BE COMPLETED FOR APPLICATION TO BE ACCEPTED J
Date: ! ' Permit Number: 1
RECMVED
�40 LIU�Il� JUL 2021
0
P1 .) Building Permit Application �'ft����n`�
fternitHng
Planning and Development Services
Building and Code Regulation Division Commercial Residential
2300 Virginia Avenue,Fort Pierce FL 34982
Phone:(772)462-1553 Fax: (772)462-1578
PERMIT APPLICATION FOR:
PROPOSED IMPROVEMENT LOCATION:
Address: 17-Z de rl L
Property Tax ID#: ( - a v� ' 001)1 '- 1)00- ,7 Lot No.
Site Plan Name: I , ,►n Block No.
Project Name: � 14,h Ides-)' et ri ce,
DETAILED DESCRIPTION OF'WORK:
/ II .S-I/ c-vv,Q .
iVeAAr
New Electrical Meter Second Electrical Meter
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit-check all that apply:
_Mechanical _Gas Tank _Gas Piping _Shutters _Windows/Do o _Pond
_Electric _Plumbing _Sprinklers _Generator Roof Pitch
Total Sq. Ft of Construction: ® � Sq. Ft. of First Floor:
�1 o�
Cost of Construction:$ 4s-100 o. Utilities: —Sewer _Septic Building Height:
OWNER/LESSEE: CONTRACTOR:
a' O r)
Name 9'Yr) % J-� Name:
Address:O L/SGj i bble nkz hr • N bJ Company:-06t,011,441n "
City: Ida i M 4vnm State:W Address: ItpolS'- /VW /-C C
Zip Code: Fax: City: K L State- r-E,
Phone No. Zip Coder yqrZ Fax: � •�� 7
E-Mail: Phone No -
Fill in fee simple Title Holder on next page(if different E-Mail--7-.
from the Owner listed above) State or County License Ccc 03�
If value of construction is 2500 or more,a RECORDED Notice of Commencement is required.
If value of HAVC is$7,500 or more,a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _ Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls, signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property. A Notice of Commencement must be recorded in the public records of St.
Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult
with lender or an attorney fore commencing work or recording our Notice of Commencement.
Sig a r of w r/Lessee/Contractor as Agent for Owner lgnatur Contractor/Lice e I er
STATE OF FLORI A STATE OF FLORID
COUNTY OF�- W COUNTY OF �'4-e1
Sxu6rn to(or affirmed)and subscribed before me of Swoyn to(or affirmed)and subscribed before me of
sical Presence or Online Notarization % P ysical Presentee or Online Notarization
this ay of 2020 by thisMaay of ✓k 2024 by
1
Name of person mak"n tatement. / Name of person making stat ent.
Personally Known OR Produced Identification V/ Personally Known v/ OR Produced Identification
Type of Identi cation ,/ /,� Type of Identification
Produced IU c,�h Produced
tgna ure of Nota (Signature of Notar Publi -
;oii?voye JENNIF RDAVIS
Commission No. :,; MY COMM;3 I� #GG 953418 ;otP�:�yc;' JENNIFER DAVIS
Commission N .:_
s. EXPIRE a ary 29,2024 :* *, MISSION#(C@$)418
Bonded Thru Notary Public Underwriters . :,e EXPIRES:February 29,2024
%•. P: I-am Public I In PDAtprc;
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
Rev.
NOTICE OF COMMENCEII<ENT
To be completed when construction value;exceeds$2,500.00
PERMIT# TAX FOLIO# 1 4509-807-0009-000-4
STATE OF FLORIDA COUNTY OF: ST LUCIE
I
The undersigned hereby gives notice that improvement-will be made to certain real prop!erty,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement II LEGAL DESCRIPTION: OAKS AT INDIAN RIVER LOT 6—122 EDEN CREEK;LANE JENSEN BEACH
GENERAL DESCRIPTION OF IMPROVEMENT: RE-ROOF j
OWNER INFORMATION OR LEESEE INFORMATION IF,THE LESSEE CONTRACTED FOR THE IMPROVEMENT:
Name:TRACI D.SMITH JEFFREY C.SMITH Phone:
Address: 9459 NW COBLENTZ AVENUE UNIONTOWN OH 44685
Interest in property: Owner i
Name and address of fee simple titleholder if different from Owner listed above):( bo e). �
CONTRACTOR'S NAME:CARDINAL ROOFING&SIDING COMPANY INC i Phone No:772-335-9550
Address: 1601 SE S.NIEMEYER CIRCLE.PORT ST LUCIE FL 34952 f
SURETY COMPANY(if applicable,a copy of the payment bond is attached):
Name and address: ;U o T w n
mx1r_n
a—
r)
Phone No.: Bond.Amount:f �O�m�m
LENDER'SNADIE: Phone No.: v_O�c�
Address: Z Q0 0 m
c�$Nmz
i �cng
Persons within the State of Florida designated by Owner upon who �,
y
m notices or other documents may be served as provided o z r
713.13(1)(a)7.,Florida Statutes: m N Name: 8 z
o n
Address: i Phone No.: rn j m
N .X
fJ �
In addition to himself or herself,owner designates G)N 'n
of O
1
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statues. m
Phone number of person,or entity designated by Owner: j 0
A 0
i c
Expiration date of Notice of Commencement: 0 1
(the expiration date may not be before the completion of construction and final payment to the contractor,but will be,l year, c
recording unless a different date is.specified): z
i 1
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF CO
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713 PART 1.SECTION 713.13.FLORIDA STATUTES AN]
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY:A NOTICE OF COMMENCEMENT 11
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FIN)
CONSULT WITH-YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF
COMMENCEMENT
Under penalty of perjury, ecl a that I have r d foregoing and that the facts Stated are true to the best of my knowledge and belief.
$ �1 � ! '
Si nature of O. ne r e or O ner s or Less e s Authorized Officer/Direetor/Partner/Manager/Attorney-in-fact
OWNER-'.. j. ..
Signat,90FY s ni'tle/Office
r Y L= 7
Theforegomg instrument;t as,ac�Cgowledged before me this day of TZ1 it e 20 Z
�^Yj�h1rGI 9s.�rn�f,1� as OWNe•'R— for
n�Nantf,,bf p Type of authority-(e.g.office,trustee) Party on behalf of whom instrument was executed
Personally K
-?! fs:Si na Ynown or produced identification
X i tA Type of Identification Produced
1'rint,5 p:Cnjjinissioned Name of Notary)
I` i
Vp i
T:IBLDIBI °orms�Ney��lpplicationsli orms\Notice Of Commencement.Docx Rev.9/15/11
,` c,1.
;. 2,1
i
{
ST. LUCIE WORKS
Aille CO��'
REVED FOR
Section A(General Information) CODE COMPLIANCE
Master Permit No. PSIS CIE COUNTY
fJ Q CC N/ 2f
Contractors Name: 1 Qiti�l a� y.. �L' License# C CC 03 ZSI
Job Address `h • .�rQrnosry� FL.
ROOF CATEGORY
❑Low Slope E3 Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
❑Asphaltic Shingles xyetal Panel/Shingles Mood Shingles/Shakes
Prescriptive BUR-RAS 150
ROOF ROOF TYPE
❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑Recovering
.ROOF SYSTEM INFORMATION ",p H010 �
Low Slope Roof Area(SF) Steep Sloped Roof Area (SF) 7 0�� Total (SF) / U y V
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
6S �
AM
OF
37'
6
r
a
��
<.
�,,
"�:�`
e_
.r'
ST. LUCIE :WORKS File Copy
Pq
CODE COMPLIANC
ST. LUCIE COO INT'V
Section D (Steep Slope Roof System) 1B0C (
Roof System Manufacturer: "� •
Notice of Acceptance Number:
FL . I702-2 . �
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
Zone 1: Zone 2e: one 2n:-Zone 2r: Zone 3e: Zone 3r:
\Der-kTy
ythdilt
[.Roof Sbpe
n A-Nmer 1 �-Ridge-vowat oNFWener Type Spaemg: 1-y 'S •N ,o�,-,�I` ,s (, -0 C.
adhesive Type: F q
T 'e=Ga Sheep
YP..
Mean Rod Height: 2Z' i�iaof•Gzvedngi •26 6 rR• S-�
Types&.Sine Drip
Edge:
s ue, S #loo-
�i 6C• F�11
File, C®y)v Phone: 954-784-2941
ederal
® 7-�51�Qv
E-Fax: 954-784-7875
o r admin@fed-eng.com
.ngineering RE �R www.fed-eng.com
®nesting, Inc.
ST. '. CIE COUNTY
DATE: 7/7/21 CC7 eY o.: 21RO551
CLIENT: Cardinal Roofing and Siding of Florida
ADDRESS: 1601 S E South Niemeya Circle,• Port St Lucie,FL 34990
PROJECT: Jeffrey Smith
ADDRESS: 122 Eden Creek Lane; Jensen Beach,FL 34957
1
ASCE 7-16 DESIGN PRESSURE CALCULATIONS
In Accordance with Chapter 30,Part I
Proiect Information: Sloped Wood Deck Roof
Height= 24' Exposure: D Ultimate Windspeed: V,,i= 170 mph
Length= 60' Category: H Basic Windspeed: Vnd = 132 mph
Width= 50' Slope: 8:12 KZ= 1.11 Kd=0.85
Design Calculations:
Velocity Pressure: q = 0.00256*[(1.11)(0.85)(1.00)(1.00)(132)2]
=42.1 psf
Width of Pressure Coefficient Zone: 0.1(50') = 5.0'
0.4(24') = 9.6' } use: a= 5.0'
Effective Wind Area: <10ft2
For parapet height three feet(3')or larger,zone three(3)can be treated as zone two(2)(ASCE7-16).
External Pressure Coefficient: Internal Pressure Coefficient
1) GCP1 = -1.8 1) GCPi = 0.18
2e) GCP2e = -1.8
2r) GCP2r = -1.8
2n) GCP2n = -2.0
3r) GCP3r = -2.0
3e) GCP3e = -3.2
Design Pressures:
1) Field P1 = 42.1*(-1.8-0.18)= -83.3 psf
2e) Perimeter Ridge: P2e= 42.1*(-1.8-0.18)= -83.3 psf
2r) Perimeter Eave : P2r= 42.1*(-1.8-0.18)= -83.3 psf
2n) Perimeter Gable: P2n= 42.1*(-2.0-0.18)= -91.7 psf
3r) Comer Ridge P3r= 42.1*(-2.0-0.18)= -91.7 psf
3e) Comer Eave P3e= 42.1*(-3.2-0.18)= -142.2 psf
MIAMI- F D R7T
QME
(ad N
AASMO R78AcaMt.�. //
_.0101 Approved Laboratory
Page 2
122 Eden Creek Lane
? Jensen Beach,FL
Based on RAS-133 and F.L. #17022.1, the following are our recommended VMAX 5V Crimp Exposed
Seam Roof Panels attachment requirements using#10 x 1.5" screw fasteners with sealing washers:
Zone 1: 12" - 12"pattern at 16" o.c. (Method B)
Zone 2e: 12" - 12"pattern at 16" o.c. (Method B)
Zone 2r: 12" - 12"pattern at 16" o.c. (Method B)
Zone 2n: 12" - 12"pattern at 16" o.c. (Method B)
Zone 3r: 12" - 12"pattern at 16" o.c. (Method B)
Zone 3e: 12" - 12"pattern at 6" o.c. (Method D)
Notes: All work shall be in compliance with the local building code product control notice of
acceptance and manufacturer specifications and the Florida Building Code 2020 edition.
Wind load calculations based on ASCE 7-16 and information provided by client.
All work shall be inspected by our field engineer or city inspector to verify compliance
with specifications.
` Sincerely;''`;:,
Kei%i ; ek3lanca`F.E: 717 Z
_ %Federal Engi�eei-ing Testing,Inc.
R
'Flor13a Reg'No. 59394
Certificate of.A #5471
�; - -
'-Miami-Dadetounty Certification#21-0201.02
_ 7
7i •.
MIAMI
(a"�c'
-=ME F D
[an�`snr�o RranoQ,o�e�_v, ° �!a—
�J _.�� Approved Laboratory
N
1 pp AA
c
BCIS Home i Log In User Registration Hot Topics Submit Surcharge Stats&Facts 1 Publications ( Contact Us BCIS Site Map I Links i Search
(Zpr
a File Copy
R
L�:-, .�� Product Approval
USER:Public User
5
Product Approval Menu>Product or Application Search>Application List>Application Detail R Ee _
,H6iM16+
WW'
. FL# FL R8 CODE COMPLIANCE
Application Type Revisionvision ��++
Code Version 2020 ST. L CIE Co �
Application Status Approved
Comments
Archived LL
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL17022 R8 COI 269a VMAX plywood.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
i
Product Approval Method Method 1 Option D
Date Submitted 10/05/2020
Date Validated 10/12/2020
Date Pending FBC Approval 10/25/2020
Date Approved 12/15/2020
Date Revised 12/16/2020
Summary of Products
FL# Model, Number or Name Description
17022.1 01: 26ga VMax on Plywood 26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 26ga VMAX plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-228 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 26ga VMAX plywood.pdf
Created by Independent Third Party: Yes
17022.2 02: 032 Aluminum VMax on Plywood Nominally 0.032" aluminum (or thicker) VMax 5V panel with
21"coverage on 15/32" (min) plywood or 3/4" (min) thick
wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 032 VMAX 21in plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 032 VMAX 21in plywood.pdf
Created by Independent Third Party: Yes
17022.3 03: 26ga VMax on Plywood 26ga (min) VMax 5V panel with 24"coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank. Option for fasteners in
the flats and in the ribs.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 26ga VMAX plywood flats.pdf
Approved for use outside HVHZ:Yes . Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.25 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 26ga VMAX plywood flats.pdf
Created by Independent Third Party: Yes
17022.4 04: 26ga CorMax on Plywood 26ga (min) CorMax corrugated panel with 29.5"coverage on
15/32" (min) plywood or 3/4" (min)thick wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL17022 R8 II 26ga CorMax Plywood HVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-161 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 26ga CorMax Plywood HVHZ.pdf
Created by Independent Third Party: Yes
17022.5 05: 26ga CorMax on Battens 26ga (min) CorMax corrugated panel with 29.5" coverage on
2x4 (min) battens.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 26ga CorMax Battens.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-161 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 26ga CorMax Battens.pdf
Created by Independent Third Party: Yes
Sack Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
3
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® e'Chsck
r Credit Card
Safe
(Jj• ' vt��� } � i x1 � Y Yi��M I `�
k'
`mot
1,7022 101 R 8
ffi
13
EXTREMEMETAL
FABRICATORS
SKILLED CRAFTERS OF METAL ROOFXNG SYSTEMS,
26ga ( min ) VMAX over 15/32" ( min ) plywood
Extreme Metal Fabricators
2120 SW Poma Dr I Palm City FL 34990
Product Description
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/811.
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#9 or #10 x 1.5" fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
m T•
I berlake Cove, LLC
3324 W Univ Ave #206 i Gainesville FL
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
N
TE ]9
F�-2020 1 O:o i — No.81377 _
� �00 08 33+01'00_
S-)3 4
Q STATE OF e�
"tORIOP.•'
�S
/ONAL
signed
'datecopies
. .. •.
and sealed and the signature,must be
verified on any ..
• Ex posed Sea
r.x
r
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A: #9 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 86 PSF
Method B: #10 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 93.5 PSF
Method C: #10 x 1.5" fastener in 12"-12" pattern at 8" o.c.: 101 PSF
Method D: #10 x 1.5" fastener in 12"-12" pattern at 6" o.c.: 228 PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in
FL 17022.01-R7
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The same entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
.Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
GTORS.
�.'$ S
'.
0 X, twt i
t "Y�, � -��', ;'a� � � �'z.�Sk �.,t,� �'TS'•''�'s,^ r'�s.�,.; '^� ?-k c€'�� �� ' �'�y°f t'; �a, ?Idr ,i
,g�gy �`Y"a h• &, � '.�8 L � "E 'i xr q�� �5,.* s �� �' Y���><,"�" M a'y��' `..�,`. � � u��`
Instructions:
Select the appropriate load table that applies to the
structure in question.
2
Determine the design wind speed for the project 2 3
location. 2 1 1 2
Use the attachment method indicated for that 2 1
windspeed within each roof zone. 2 2 3 a
2 1 2 2 3 a
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken 2
for each zone and reported using the standard zones 2 1 1 2
1-2-3: 2
Zone 1 includes zones 1 and 1' a I3 3 a
Zone 2 includes zones 2e, 2r, and 2n �-1aL HIPROOF GABLEROOF �aL f
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple a:10%OF LEAST HOIZONTAL DIMENSION OR 0.4H,WHICHEVER IS SMALLER,BUT NOT
LESS THAN EITHER 4%OF LEAST HORIZONTAL DIMENSION OR 0FT(OSHA
scheme, at the expense of some design efficiency. OR AS DETERMINED BY DESIGN OR OTHER AF4 IWILE CODE
Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional.
METHOD A: METHOD B: METHOD C: METHOD D:
#9 AT 16"O.C. ##1l)AT 16"O.C. #10 AT 8"O.C. #10 AT 6"O.C.
r —12"(NOM) 12" (NOM) -� NR: NOT RATED. CONSULT DESIGN
PROFESSIONAL AS NEEDED
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof,or gable/hip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26 a 5V Crimp on 15/32" ghLAXood FL17022.01: 26 a 5V Crimp on 15/32" I wood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1 I "A A A A A A A
Zone 2: A A A A A 'TA A A F jC D FOMY, Zone 2: A A A A CDC=�
Zone 3: A A A A A A i B CD� D .p r~ tq 5n
Zone3: ,A A A l ;C„ D D ,.
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 70,hip roof with Have either a flat roof less than 7°,hip roof with
max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12&12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26 a 5V Crimp on 15/32' pl ood FL17022.01: 26 a 5V Crimpon 15/32" plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: ; A A A A A A A A A A A Zone 1: A A A A A A A l B C
Zone 2: A A A A A . A A A _A .B. C - Zone 2: A A A. _A A B
Zone 3: A A A A A A A B �SD ® �®' Zone 3: 3 A A A B D =<
- s - e
C r• , � �k � 'V' "v 3„serpp�, u.1. q Lw^+ �.w
31-1 MAN.
BCIS Home i Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications 1 Contact I to Map I Links Search
Florida File Copy
Product Approval
c,, ` - USER:Public User
REVIEWED FUH
ProductApproval Menu>Product or Application Search>Application List>Application Detail
CODE (COMPLIANCE
a a FL# FLvision . "�
31 ST L CIE COUNTY
Application Type Revision
Code Version 2020 11�®OCC
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email lilt West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By John W. Knezevich, PE
(s Validation Checklist- Hardcopy Received
Certificate of Independence FL5259 R31 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
FM 4474 2011
FRSA/TRI, Sixth Edition 2018
UL1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/22/2020
Date Validated 10/26/2020
Date Pending FBC Approval 11/01/2020
Date Approved 12/15/2020
Date Revised 12/21/2020
Summary of Products
FL# Model, Number or Description
Name
5259.1 Polyglass Roof Roofing underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5259 R31 II 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside HVHZ: Yes R31.g_df
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this Evaluation Reports
application relates to one particular FL5259 R31 AE 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
underlayment system for use in tile roof R31.pdf
systems. Refer to ER Section 5.8.3 for other Created by Independent Third Party: Yes
systems and associated maximum design
pressures. 2.) Refer to ER Section 5 for
other limits of use.
Back Neut
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy atatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
w ® eIIheck
Credit Card
Safe E
MEMO ! Etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
Polyglass USA, Inc. Evaluation Report P12060.02.09-1127
1111 West Newport Center Drive FL5259-1131
Deerfield Beach, FL 33442 Date of Issuance:02/24/2009
(954)233-1330 Revision 27:09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEIVIO ETC,LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 17.
Prepared by: ,
���..........
Robert J.M. Nieminen, P.E.
Florida Registration No.59166,Florida DCA ANE1983 %'1.i n" The facsimile seal appearing was authorized by Robert Nieminen,P.E.on
09/30/2020.This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC,LLC
ONEMO etc.
ROOFING COMPONENT EVALUATION:
1. C.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
DA•D
Section Property Standard'' Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1/R905.1.1 Material standard ASTM D226 2009
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
1507.11.2/R905.11.2 Material standard ASTM D6164 2011
1507.11.2/R905.11.2 Material standard ASTM D6222 2011
1507.11.2/R905.11.2 Material standard ASTM D6509 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. 'REFERENCES:
Ent Examination Reference Date Entity Examinatwn Reference _ Date
_ ... - to
ERD(TST 6049) Wind Uplift 11757.08.01-1 _ 08/13/2001 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) TAS 103 PLYG-SC12115.08.17 08/08/2017
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) TAS 103 PLYG-SC13035.08.17 10/31/2017
ERD(TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 FM(TST 1867) Wind Uplift 3004091 01/12/2000
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ICC-ES(EVL 2396) IBC Compliance ESR-1697 04/01/2019
ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 M-D(CER 1592) HVHZ Compliance NOA 17-0614.22 07/06/2017
ERD(TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 MTI(TST 2508) ASTM D4798 JX20H7A 04/01/2008
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 NEMO(TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018
ERD(TST 6049) ASTM D4977 P13030.11.09-3 11/30/2009 NEMO(TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019
ERD(TST 6049) ASTM D1970 P33360.06.10 06/25/2010 NEMO(TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019
ERD(TST 6049) TAS 103 P33370.03.11 03/02/2011 NEMO(TST 6049) ASTM D6222 4S-PLYG-18-002.05.19-C 05/20/2019
ERD(TST 6049) Tensile Adhesion P33370.04.11 04/26/2011 NEMO(TST 6049) ASTM D1970 4j-PLYG-I9-5SUDL-00.A 09/10/2019
ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-G 10/08/2019
ERD(TST 6049) TAS 103 P40390.08.12-1 08/06/2012 NEM0(TST 6049) TAS 103 4S-PLYG-18-004.10.19-1 10/08/2019
ERD(TST 6049) Tensile Adhesion P40390.08.12-2 08/07/2012 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-L 10/09/2019
ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 NEMO(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-01.A 10/10/2019
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.12.19-F 12/18/2019
ERD(TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-02.A 01/02/2020
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 NEMO(TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.H 01/14/2020
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEMO(TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.K 01/14/2020
ERD(TST 6049) ASTM D6164 P37590.03.13-3A 05/06/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.01.20.A 01/16/2020
ERD(TST 6049) ASTM D6S09 P37590.03.13-1-R1 06/26/2013 NEMO(TST 6049) ASTM D6164 4S-PLYG-18-004.01.20.B 01/16/2020
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO(TST 6049) ASTM D6222 4S-PLYG-18-002.12.19-K-R1 01/07/2020
ERD(TST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO(TST 6049) TAS 103 PLYG-SC15855.05.20.A 05/29/2020
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 NEMO(TST 6049) TAS 103 4j-PLYG-20-SSUDL-01 07/06/2020
ERD(TST 6049) Wind Uplift P11781.11.03-RS 11/26/2013 NEMO(TST 6049) ASTM D6222 4q-PLYG-I9-SSMBB-05.A 07/23/2020
ERD(TST 6049) 30/90 physicals P45270.05.14 05/12/2014 NEMO(TST 6049) ASTM D4798/1)1623 4j-PLYG-I9-SSUDL-05.A 09/10/2020
ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 NEMO(TST 6049) ASTM D1970 4j-PLYG-20-SSUDL-05.A 09/30/2020
ERD(TST 6049) Tensile adhesion 6020.09.14-6 09/08/2014 NEMO(TST 6049) TAS 103 4j-PLYG-20-SSUDL-05.0 09/30/2020
ERD(TST 6049) Tensile adhesion P46520.10.14 10/03/2014 NEMO(TST 6049) TAS 103 4j-PLYG-20-SSUDL-11 09/30/2020
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization N32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 2 of 17
ONEMO I etc.
Enti Examination Reference Date Entity Examination Reference Date
ERD(TST 6049) ASTM D1970/D4798 P43290.10.14 10/17/2014 PRI(TST 5878) Tensile Adhesion PRIO1111 04/08/2002
ERD(TST 6049) TAS 103 PLYG-SC7550.03.15 03/24/2015 PRI(TST5878) TAS 103 PUSA-018-02-01 07/14/2003
ERD(TST 6049) Tensile adhesion P40390.04.15 04/03/2015 PRI(TST5878) TAS 103 PUSA-035-02-01 09/29/2006
ERD(TST 6049) TAS 103 P44360.10.14-R1 05/18/2015 PRI(TST5878) TAS 103 PUSA-055-02-02 12/10/2007
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 PRI(TST5878) ASTM D6222 PUSA-061-02-02 01/28/2008
ERD(TST 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016 PRI(TST 5878) ASTM D6164 PUSA-088-02-01 07/29/2009
ERD(TST 6049) Tensile adhesion PLYG-SC10130.06.16-2 06/27/2016 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
ERD(TST 6049) TAS 103 PLYG-SC10130.06.16-3 06/27/2016 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
ERD(TST 6049) ASTM D3970/D4798 PLYG-SC8080.07.16 07/16/2016 UL(QUA9625) Quality Control Service Confirmation(FL) 09/13/2018
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 UL(QUA9625) Quality Control Service Confirmation(TX) 11/07/2019
ERD(TST 6049) TAS 103 PLYG-SC13040.12.16 12/27/2016 UL(QUA9625) Quality Control Florida BCIS Current
oe1401 t o
Product Material Standard Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet
4.3 Elastoflex S6 G ASTM D6164 FL, PA Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRl 09-18
4.4 Elastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TR109-18
4.5 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.6 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
FRSA/TRI 09-18 waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.7 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRl09-18
4.8 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
(FR) FRSA/TRI 09-18
4.9 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied"Cap Sheet"in the
"Two Ply System"from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
4.10 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet"in the
"Two Ply System"from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth
Edition beneath mechanically fastened tile roof systems
4.11 Polyflex SA P ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI 09-18
4.12 Polyflex SA P FR ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRl09-18
4.13 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet
4.14 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet
NEIVIO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization N32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 3 of 17
OMEMO etc.
PRODUCT14.
Product Material Standard 7714 t(s) Description
4.15 Polystick IR-Xe ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.16 Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 PA,TX membrane,glass fiber reinforced,surfaced with
polyolefinic film surface
4.17 Polystick MU-X ASTM D19701 FL,NV, PA Nominal 54-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polypropylene film surface
4.18 Polystick TU Max ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane with a 190 g/m2 polyester fabric surface
4.19 PolystickTU P FRSA/TRI 09-18 FL, PA,TX Nominal 130-mil thick rubberized asphalt waterproofing
membrane,glass-fiber/polyester reinforced,with a
granular surface
4.20 PolystickTU Plus ASTM D1970 FL, PA,TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane,glass fiber reinforced,with a polyester fabric
surface
4.21 Polystick XFR ASTM D1970 NV,TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane,glass fiber reinforced,surfaced with a
textured film surface
5.1 This is a Building Code Evaluation. Neither MEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for
any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the productJs specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
I Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard
laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 4 of 17
ONEMO etc.
5.6 Allowable Roof Covers:
TABLE 1: ROOF"COVER OPTIONS
Clay and Concrete Tile' Metal Slate or wood
Underlayment Shingles
Asphalt (1507.3) Slate-Type
Mechanical Adhesive- Panels Shingles Shingles Shingles
(150Z2J : Attach Set (1507.4) (1507.5) (150Z7) (isoZ s) Shakes(150Z9)
Yes Yes Yes Yes Yes Yes Yes Yes
Elastobase (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to (Alternate to D226, (Alternate to D226,
D226,Type II) See 5.8.3) See 5.8.3) D226,Type II) D226,Type II) D226,Type II) Type II) Type II)
Yes Yes Yes Yes Yes Yes Yes Yes
Elastobase P (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to (Alternate to D226, (Alternate to D226,
D226,Type II) See 5.8.3) See 5.8.3) D226,Type II) D226,Type ll) D226,Type II) Type II) Type II)
Yes Yes
Polyglass Base No (as Base Sheet, (as Base Sheet, No No No No No
See 5.8.3) See 5.8.3)
Yes Yes
Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No No No
I
See 5.8.3) See 5.8.3)
Elastoflex S6 G No Yes Yes No No No No No
(See 5.6.1)
Elastoflex S6 G FR No Yes No No No No No No
Yes Yes
HydraGuard Dual Pro Yes No No Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R9D5.1.1.3)
Yes Yes Yes
HydraGuard Tile Pro Yes Yes Yes Yes Yes
(See 5.6.1) (loins strips,1507.1.1.3 (Joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Mule-Hide SA-APP Cap Sheet No Yes Yes No No No No No
(See 5.6.1)
Mule-Hide SA-APP Cap Sheet(FR) No Yes Yes No No No No No
(See 5.6.1)
Polyflex G No Yes Yes No No No No No
(See 5.6.1)
Polyflex G FR No Yes No No No No No No
Polyflex SA P No Yes Yes No No No No No
(See 5.6.1)
Polyflex SA P FR No Yes Yes No No No No No
(See 5.6.1)
Yes Yes
Polystick IR-Xe Yes No No No No Yes
(joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
Polystick MTS Plus Yes Yes No Yes Yes Yes
(joint strips,3507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
((oint strips,1507.1.1.3 Uoin[strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Polystick TU Max No Yes Yes Yes Yes No Yes Yes
(See 5.6.1) (loint strips,1507.1.1.3 (Joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Polystick TU P No Yes Yes No No No Yes Yes
(See 5.6.1) (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes Yes
Polystick TU Plus Yes Yes Yes Yes Yes
(See 5.6.1) Uoint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
Polystick XFR Yes Yes No Yes Yes Yes
(joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
NEMO ETC,LLC. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 f"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 5 of 17
ONEMO etc.
5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations.
'TABLE 1A:ALLOWABLE UNDERLAYMENT.j'TILE-ADHESIVE COMBINATIONSZ'
Underlayment Adhesive Florida Product Approval
Polystick TU Max or Polystick TU Plus DAP Foam"Touch'n Seal FL14506
Storm Bond Roof Tile Adhesive'
HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or Polystick Dupont"Tile Bond—Roof Tile FL22525
TU Plus Adhesive"
Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA- ICP Adhesives and Sealants
APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, "Polyset®AH-160" FL6332
Polystick TU P or Polystick TU Plus
Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA- ICP Adhesives and Sealants
APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, "Polyset®RTA-1" FL6276
Polystick TU P or Polystick TU Plus
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates(designed to meet wind loads for project)
Underlayment"' Application
Type Primer Material(s)
HydraGuard Dual Pro, (Optional)ASTM plywood,OSB,Southern Yellow Pine or Huber Engineered
HydraGuard Tile Pro,Polystick IR- Deck/ D41 Woods"ZIP System"Panels
Xe,Polystick MTS Plus,Polystick sheathing
ASTM D41 structural concrete
MU-X,Polystick TU Max, self- ASTM C1289 Type II Class 1 polyisocyanu rate,ASTM
Polystick TU P,Polystick TU Plus, adhering Insulation (Optional)ASTM C1289 Type V polyisocyanurate-composite,DensDeck
Polystick XFR,Mule-Hide SA-APP D41 or WB-3000 Prime or SECUROCK Gypsum-Fiber Roof Board
Cap Sheet,Mule-Hide SA-APP
Cap Sheet(FR),Polyflex SA P or Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P or Mule-
Polyflex SA P FR Hide Nail Base
Deck ASTM D41 structural concrete
Elastoflex S6 G or Elastoflex S6 G Insulation (Optional)ASTM DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
FR hot asphalt D41
Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P,Mule-
Hide Nail Base or Polyglass G2 Base
Deck ASTM D41 structural concrete
torch- Insulation (Optional)ASTM DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
Polyflex G or Polyflex G FR applied D41
Base Sheet N/A Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass
G2 Base or Polyglass Base
z Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FLS259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 6 of 17
NNEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets-not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but—
for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1(forTwo-
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-52.5 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min.4-inch wide strips of Elastoflex SAW over all OSB joints
Base Ply: Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#2 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
NEMO ETC,LLC. Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 7 of 17
OMEMO etc.
#5 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#6 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered.
#7 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#8 All other direct-deck,adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29(February 2020)for enhancements.
#9 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#10 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#11 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
pP pP g p
NEW ETC,LLC. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVH2 EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 8 of 17
NEW I etc.
#12 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#13 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt.
#14 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#15 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#16 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#17 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#18 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 9 of 17
OMEMO I etc.
#19 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#20 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#22 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#23 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#25 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 7Tn EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 10 of 17
ONEMO I etc.
#26 Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#27 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: (Optional)PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#28 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#29 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#30 Maximum Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#31 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#32 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVH2 EVALUATION F1.5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 11 of 17
*NEMO etc.
#33 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#34 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with CMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#35 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#36 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt.
#37 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#38 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEMO ETC,U.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 12 of 17
MEMO I etc.
#39 Maximum Design Pressure=-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
to
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#40 Maximum Design Pressure=-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#41 Maximum Design Pressure=-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#42 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#43 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 13 of 17
ONEMO I etc.
#45 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#46 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS Plus,self-adhered
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#47 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: CMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#48 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#49 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#50 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt.
#51 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
NEW ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 14 of 17
i
OMEMO I etc.
5.9 Exposure Limitations:
TABLE.3:'EXPOSURE`LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base Mechanically attached 30
Polystick IR-Xe or Polystick MU-X Mechanically attached 90
HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick MTS Plus,Polystick TU Max,Polystick
TU P,Polystick TU Plus or Polystick XFR Any type(per Table 1) 180
Elastoflex S6 G,Elastoflex S6 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Adhesive-set tile roof system 180
Sheet(FR),Polyflex G,Polyflex G FR,Polyflex SA P or Polyflex SA P FR Mechanically attached UNLIMITED
5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE`4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Staging Slope
Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) Prohibited without battens
HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS Plus Flat 6-tile stack(4 over 2) 5:12
Lugged 6-tile stack(4 over 2) 4:12
Flat 6-tile stack(4 over 2)or 10-tile stack 7:12
Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat or Lugged 6-tile stack(4 over 2) 7:12
Polystick TU Plus
Flat or Lugged 10-tile stack 6:12
Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens
I
�I
i
NEMO ETC,I.I.C. Evaluation Report P32060.02.09-R27
Certificate ofAuthorization N324S5 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underiayments Revision 27:09/30/2020
Page 15 of 17
ONEMO I etc.
6.1 Polyglass Roof Underlay'Wen ts shall be installed in accordance with Polyglass published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application,and prime the substrate(if applicable).
6.3 " " Elastobase,'Elastobase P ofr"Mi Ule-Hide Nail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM D226,Type
II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed,and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
MU-X,Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP,Polyflex SA P FR,Mule-Hide SA-APP Cap
Sheet or SA-APP Cap Sheet(FR),self-adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G
FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table
1.
6.3.2 Tile Applications:
6.3.2.1 Elastobase(poly-film top), Elastobase P(poly-film top)and Mule-Hide Nail Base are limited to use as a mechanically attached
base sheet in the"TWO-PLY SYSTEM"from FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual,Sixth
Edition,followed by Polystick MTS Plus,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick XFR,Polyflex SAP,Polyflex
SA P FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered or Polyflex G or Polyflex G FR,torch-applied. Tile
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.3.2.2 Elastobase(sanded-top)and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the"TWO-
PLY SYSTEM" from FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by
Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380),asphalt-applied or Polyflex
G or Polyflex G FR,torch-applied. Tile roof installation method is limited by the selected Cap Sheet,as set forth in Table 1.
• When Elastobase(sanded-top)or Elastobase P(sanded-top)is followed by asphalt-applied Elastoflex S6 G, Elastoflex S6
G FR or FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380), refer to FRSA/TRI,Sixth Edition,Appendix A,Table 1
or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase(sanded-top)or Elastobase P(sanded-top)is followed by torch-applied Polyflex G or Polyflex G FR,refer
to Section 5.8.3.2 herein for attachment requirements.
6.4 HydraGuard Dual Pro,HydraGuard Tile Pro,Mule-Hide,SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,
Polyflex SA"P'FR,Polystick"IR=Xe,Poly`stick'MTS Plus,Polystick`MU-X,Polystick TU Max;'Polystick TU P,Polystick TU Plus or
Polystick XFR:
ti
6.4.1 General:
All t •4 1
seal-lap seams(selvage laps must be firmly rolled with a k„ M
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
X
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric). ;
���
63tr
3"�
s
View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
NEIVIO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 16 of 17
OMEMO I etc.
6.4.2 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt, Elastobase,Elastobase P or
Mule-Hide Nail Base,the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile Applications(excludes HydraGuard Dual Pro,Polystick IR-Xe and Polystick MU-X):
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi-Ply Underlayment Systems:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro,POlyflex SA P,Polystick MTS Plus,Polystick MU-X,Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive-set tile systems. Limits of use are those associated with the top-layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 'Elastoflex.S6 G:or Elastoflex%G FR..
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply
System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.6 .. Polyflex-G or.Polyflex G FR.�
6.6.1 Shall be installed in compliance with requirements as an alternate to the"Heat Applied Cap Sheet"in the"Two Ply System"in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
117. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section
4 herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (414)248-6409; Karen.buchmann@ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC. Evaluation Report P32060.02.09-R27
Certificate ofAuthorization#32455 7'"EDITION(2020)FBC NON-HVH2 EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 17 of 17