Loading...
HomeMy WebLinkAboutPROJECT INFORMATION Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wysslingconsulting.com July 2, 2021 Jacob Humpherys, COO Meraki Solutions 30700 Wekiva River Road Sorrento, FL 32776 Re: Engineering Services Rochester Residence 6905 Bayard Road, Fort Pierce, FL 7.920 kW System Dear Mr. Humphreys: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Meraki Solutions representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by Meraki Solutions and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of truss system with all chords constructed of 2 x 4 dimensional lumber at 24” on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce Pine Fir #2 or better with standard construction components. The existing roofing material consists of composite asphalt shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used • 160 MPH wind loading based on ASCE 7-16 Exposure Category “C” at a slope of 20 degrees • 7 PSF = Dead Load roofing/framing Live Load = 20 PSF/ 0 PSF(where panels are installed) • 3 PSF = Dead Load solar panels/mounting hardware Total Dead Load =10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the (FBC 2020, 7th Edition). Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent “Ironridge Installation Manual”, which can be found on the Ironridge website (http://ironridge.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the Natio nal Design Standards (NDS) of timber construction specifications for Spruce Pine Fir #2 assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 ½”, is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 ½” with a minimum size of 5/16” lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48” o/c. 4. Panel supports connections shall be staggered to distribute load to adjacent trusses. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the FBC 2020, 7th Edition, current industry and standards, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Florida License No. 81558 Fort Pierce Utilities Authority Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF PLAN PV04 ROOF ATTACHMENTS PV05 MOUNTING DETAIL PV06 LINE DIAGRAM PV07 LABELS PV08 PLACARD PV09 SITE PHOTOS COVER PAGE - PV01 DRAWN BY: SoloCAD 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS AERIAL VIEW: SHEET INDEX: EQUIPMENT: AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) RACKING: IronRidge - 48" O.C. OCCUPANCY: R-3 ZONING: RESIDENTIAL APPLICABLE GOVERNING CODES 2020 NEC 2020 FBC 7th Edition 2018 IBC 2018 IEBC 2018 IRC STREET VIEW: GENERAL NOTES SITE SPECIFICATIONS AC INV MSPM JB JB JB Fort Pierce Utilities Authority SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: EQUIPMENT LEGEND: INVERTERVISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINE BATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER SUB SUB PANEL ENGINEER STAMP (IF APPLICABLE) SITE PLAN - PV02 DRAWN BY: SoloCAD 126'-5" 77'-0" FRONT OF HOME 6905 Bayard Rd. MP1 PITCH: 20° AZIMUTH: 90° MP2 PITCH: 20° AZIMUTH: 180° MP3 PITCH: 20° AZIMUTH: 270° AC INV MSPM JB JB JB Fort Pierce Utilities Authority SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: EQUIPMENT LEGEND: INVERTERUTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV MSP M COMBINER BOX BATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER SUB SUB PANELVISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER)PV AC ENGINEER STAMP (IF APPLICABLE) ROOF PLAN - PV03 DRAWN BY: SoloCAD FRONT OF HOME MP1 PITCH: 20° AZIMUTH: 90° MP2 PITCH: 20° AZIMUTH: 180° MP3 PITCH: 20° AZIMUTH: 270° 18'' TYP 3' TYP ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING manufactured_truss RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 MSP JB JB JB EQUIPMENT INFORMATION: RAIL MANUFACTURER IronRidge RAIL PART NUMBER XR-100 ATTACHMENTS FlashVue ATTACHMENT QTY 82 SPLICE QTY 10 MIDCLAMP QTY 32 ENDCLAMP QTY 32 ROOF INFO: Fort Pierce Utilities Authority SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: ENGINEER STAMP (IF APPLICABLE) PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:24 ARRAY AREA:MODULE COUNT * 18.06ft² = 433.44 ROOF AREA:1947.28 ft² PERCENT OF ROOF COVERED:22% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1200 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 14.63 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²ROOF ATTACHMENTS - PV04 DRAWN BY: SoloCAD 4'-0" RAIL (E) COMP SHINGLE ROOF (1 LAYER) ATTACHMENT PV MODULE (E) RAFTER/TOP CHORD DETAIL, MOUNTING AND FLASHING 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT (PER MANUFACTURER) 4" RAIL 2.5" MIN. EMBED. FLASHING (SEE DATASHEET FOR DETAILS) RAIL 1" PV MODULE FRAME RAIL ATTACHMENT 2'-8" MIN - 3'-10" MAX 3 RAIL PV MODULE 48" MAX SPAN1'-8" MAX. 21 FRONT VIEW 10" MIN - 1'-4" MAX 2'-8" MIN - 3'-10" MAX 10" MIN - 1'-4" MAX SIDE VIEW3 (E) RAFTER/TOP CHORDS (E) RAFTER/TOP CHORD END CLAMP DETAILS MID CLAMP DETAILS21 END CLAMP MID CLAMP EQUIPMENT INFORMATION: RAIL MANUFACTURER IronRidge RAIL PART NUMBER XR-100 ATTACHMENTS FlashVue ATTACHMENT QTY 82 SPLICE QTY 10 MIDCLAMP QTY 32 ENDCLAMP QTY 32 ROOF INFO: ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING manufactured_truss RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 Fort Pierce Utilities Authority SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:24 ARRAY AREA:MODULE COUNT * 18.06ft² = 433.44 ROOF AREA:1947.28 ft² PERCENT OF ROOF COVERED:22% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1200 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 14.63 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft² ENGINEER STAMP (IF APPLICABLE) MOUNTING DETAIL - PV05 DRAWN BY: SoloCAD AC DC J-BOX = = = = = = STRING (2) 12 MODULES = = = = = = STRING (1) 12 MODULES J-BOX J-BOX 2 3 UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT 1 1 SolarEdge SE7600H-US (240V) 2 (E) 120/240 VAC TO UTILITY GRID (E)UTILITY METER (E) LOADS N G SUPPLY SIDE CONNECTION: NEC 230.46, NEC 230.79, NEC 705.12(A) (E)GROUNDING ELECTRODE INTERCONNECTION NOTES 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)] WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH [NEC 240.21(B)] DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. 3. FUSED AC DISCONNECT TO BE USED. 4 (E) 150A-2P (E) 150A MAIN SERVICE PANEL 4 (N) 40A FUSES PV AC DISCONNECT 60A FUSED, AIC 10kA VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE DATE: July 1, 2021 SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) Fort Pierce Utilities Authority Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. ENGINEER STAMP (IF APPLICABLE) LINE DIAGRAM - PV06 DRAWN BY: SoloCAD Conduit & Conductor Schedule TAG WIRE GAUGE DESCRIPTION QTY CONDUIT SIZE CONDUCTOR RATING # OF CONDUCTORS DERATE TEMP. DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 10 AWG PV-WIRE , USE-2, COPPER (L1, L2)(2)N/A - FREE AIR 35A N/A - FREE AIR 0.96 33.6A N/A - FREE AIR 6 AWG BARE, COPPER (GROUND)(1) 2 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (L1, L2)(2)3/4" EMT 35A 1 0.96 33.6A 11.9%10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (GROUND)(1) 3 10 AWG THHN/THWN-2, COPPER - (L1, L2)(4) 3/4" EMT 35A 0.8 0.96 26.88A 19.8% 10 AWG THHN/THWN-2 - (GROUND)(1) 4 6 AWG THWN-2 COPPER - (L1, L2, NEUTRAL)(3)3/4" EMT 65A 1 0.96 62.4A 35.5%8 AWG THWN-2 COPPER - (GROUND)(1) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER EQUIPMENT SCHEDULE: TYPE:QTY:DESCRIPTION:RATING: MODULES:(24)TSM-DD06M.05(II) 330 330 W INVERTERS:(1)SolarEdge SE7600H-US (240V)7600 W AC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE 60A DC OPTIMIZERS:(24)SolarEdge P340 15 Adc SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING- MAXIMUM NUMBER OF MODULE STRINGS. MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER. Fort Pierce Utilities Authority SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: LABEL 6 MARKED AT AC DISCONNECTING MEANS. [NEC 690.54] LABEL 5 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES.[NEC 705.12(B)(2)(3)(c)] LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(c)] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT 2 8 6 9 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 7 1 1 1 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 7 3 LABELING DIAGRAM: LABEL 7 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(D)(2)] LABEL 9 SIGN LOCATED ON OR NO MORE THAN 3FT FROM INITIATION DEVICE [NEC 690.56(C)(2)]. LABEL 8 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 1 PLACED ON THE MAIN DISCONNECTING MEANS FOR THE PV SYSTEM. [NEC 690.13(B)] LABELING NOTES: 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2.LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 3 4 1 LABEL 4 PLACED ON EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES [NEC 705.10(C)] 2 3 4 1 ## ### LABEL 2 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] ENGINEER STAMP (IF APPLICABLE) LABELS - PV07 DRAWN BY: SoloCAD AC INV MSPM JB JB JB Fort Pierce Utilities Authority SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CAUTION DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) 6905 Bayard Rd., Fort Pierce FL 34951 ENGINEER STAMP (IF APPLICABLE) PLACARD - PV08 DRAWN BY: SoloCAD PV ARRAY PV ARRAY MAIN DISTRIBUTION UTILITY DISCONNECT AC DISCONNECT INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH FRONT OF HOME PV ARRAY Fort Pierce Utilities Authority SITE INFORMATION Shawn Rochester 6905 Bayard Rd. Fort Pierce , FL 34951 AC SYSTEM SIZE: 7.6 kW AC DC SYSTEM SIZE: 7.92 kW DC Lat, 27.5454516 Long, -80.3948952 (24) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE7600H-US (240V) INVERTER(S) DATE: July 1, 2021 Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 CONTRACTOR INFORMATION: SITE PHOTOS: ENGINEER STAMP (IF APPLICABLE) SITE PHOTOS - PV09 DRAWN BY: SoloCAD