FL # FL27499-R2
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juanOadynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Comphance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Lucas A. Turner, P.E„ MBA
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of product Standards
Certified By
Sections from the Code
FL27499 R2 CQL_LyjLMLWff
Standard
Year
TAS 100
1995
TAS 110
2000
TAS 12S
2003
https:fffloridabuilding. orglprtpr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM61AUfHr09JhSJEVB8g2gEgg%3d%3d 1/5
1/18/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
Go to Page 49
10/24/2020
10/26/2020
11/01/2020
12/16/2020
12/17/2020
10 10 Page 1 / 2 0 •
FL #
Model, Number or Name
Description
27499.1
DM Class 1000 1" Nallstrip
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R2 II NSS16HZ odf
Approved for use outside HVHZ: Yes
Verified By: Scott Walters 62354
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R2 AE DM Fvall pAf
Created by Independent Third Party: Yes
27499.2
DM Class 1000 1" Nallstrip,
.032" Aluminum roof panel, 16" wide, with I" snap fit seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva[ report for Limits of Use.
FL27499 R2 II N A16H .pd[
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R2 AF DM FvAD.giff
Created by Independent Third Party: Yes
27499.3
DM Class 1050 1 1/2" Nallstrip
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499 R2 lI NSAI9HZ =
Verified By: Scott Wolters, RE. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R2 AE DM vala pd[
Created by Independent Third Party: Yes
27499.4
DM Class 1050 1 1/2" Nallstrip
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva] report for Limits of Use.
FL27499 R2 II NSS19HZ.12d[
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R2 AF DM Fval4 pd1
Created by Independent Third Party: Yes
27499.5
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva[ Report for Limits of Use.
Installation Instructions
FL27499 R2 II DM Dwg5,p&
Verified By: Scott Wolters FLPE# 62394
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R2 AE DM vals.pX
Created by Independent Third Party: Yes
27499.6
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Installation Drawings and Eval Report for
Limits of Use.
Installation Instructions
FL27499 R2 II DM Dwg6.pdf
'Verified By: Scott Wolters FLPE# 62394
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R7 AF DM Ve16.pdf
Created by Independent Third Party: Yes
27499.7
DM Class 1150 1" Mechanical Seam
26 Ga. Galvalume coated steel roof panel, 21" wide, with 1"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
,FL27499 R2 II DM DwoZ,pdf
hftps:/Ifoddabuilding.org/pr/pr app_dfl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM61AUfHrO9JhSJEVB8g2gEgg%3d°/"3d 2/5
WOLTERS ENGINEERING
ENGINEERING, DRAFTING. CONSULTING
15211 970h Road N
West Palm Beach, FL 33412
Ph/Fx'(561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 1000 26 GA. GALVALUME 1" NAILSTRIP 16" WIDE
ROOF PANEL (FLPA# 27499.1)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the 7m Edition (2020) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.40-450-44 and G3443.14-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "NSS16-HZ" dated 8/15/19, signed and sealed by Scott Wolters, PE,
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE.
3 Supplemental Calculations to support "NSS16-HZ" drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 71h Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 16" (nominal)
Fastener Spacing across panel: 16" (at Nailstrip)
(Panels overlap with male/female snap fit)
Min. Slope: HVHZ: 2"712"
Non-HVHZ: V2112" (with Lap Sealant)
3"112" (no Lap Sealant in Field Zone)
'rFrIAl MIN, IN AI �KIANi CIVIAIi4A1,1I I ; '?10r`FGONI�l o N41\11tPOWN
Field
Installation
Perimeter & Comer
Installation
Max, Design Pressure:
-116 psf
-176 psf
Fastener Spacing:
3" From Ends, 6" Max. O.C.
3" From Ends, 6" Max. O.C.
Min Panel Fasteners:
#10xl" Panclip Fasteners
#10x1" Panclip Fasteners
Panel Sealant:
Continuous bead of Geocel 2300
or 2320 at Nailstrip side of seam
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps meeting the requirements of
FBC Section 1507.1.1.1, may be used to prevent galvanic reactions.
Underlavment: Minimum ASTM D 226 Type 11, installed and anchored per FBC Section
1507.1.1.1 (min).
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps meeting the requirements of
FBC Section 1507.1.1.1 may be used to prevent galvanic reactions.
Minimum Substrate: /z (15/32" min) 4-ply CDX Plywood or'/<" solid wood planks S.G. = .42
min. nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The %" wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer,
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
5P CAI.IZIN6IN IMPAC1"1,5151ANrCUMAINVM15, 5f0rTrIZ0N1S. & WI )OW)
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. Where required by the Florida Building Code, panels shall be
permanently labeled with the manufacturer's name and/or logo, and the
following statement, "Dynamic Metals FL#27499.1, DM Class 1000".
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 31d party CIA provider, to the dimensions shown on Drawing NSS16-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ2-2310920
5VC-0490718 5VC-0360516 SSQ2-2320920
Re -Roofing: The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1511 of the Florida Building Code.
If you have any questions or need more information concerning this approval, please contact me.
Thank you, Otte
��• �t �. L N,� �V,
No 62354
Cott Wolters x `:
FL PE# 62354
VT20 ?020:c`: STATE of
'! it
+`d,,d f!! I I I lt`y
5PF:CIPo.IZIN( IN IMPACT PF5151AN1 CU1 JAINVVN_LS ()k°FFp0�ti5.g WINf70W5
.v us rsm s.wm '; "E ji'o, zeerset (Iw) tau totad/swduAPp'lo/w AItlW3 SSZL-GZ9h9S1 Hd
M NVW 151 . ,� , �,%3r�. y yay �^Ya ice` I6Z/-6791i951 'xvi L9LEF 1i 'H�tl3B Wltld 153M
Bl SI B ilNYlq 311YNr _p 3als N UYW W[6 41WI r
4sita "co) ia+r7vtawmwoudpmmm �tlOd 3A4d OVE ��
B�°B'u Sld13W JINVNA4
T
i
b rn
o�N
ino=
0
j
8
' Q
C
3
°
�YW
c
I
u
1`1
O
U
N
LLJ =
>
J
CO W
4' Z
d Q
LL
cry O
O
Q �
w
T
C) J
C> Q
0
T
U) J
Q �
J Q
U �
04
kx�
N
0
a`
a
a