HomeMy WebLinkAboutEVALUATION REPORT Ceraricate of Authorization Mo. 29824 E K ILRE 17520 Edinburgh Drive Tampa,FL 33647 TE HAIICAL SERVICES, LLC (813)480-3421 EVALUATION tEPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: BEACON SALES ACQUISITIONS, INC. Issued October 14,2020 CIO OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Coming Parkway Toledo,OH 43657 (800)438-7465 www.owenscoming.com Manufacturing I ocation: Houston,TX Brentwood,NH Quality Assura e: PRI Construction Materials Technologies,LLC(QUA9110) SCOPE Category: Roofing file dopy Subcategory: Undedayments Code Sections: 1507.1.1, 1507.1.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction N aterials Technologies(TST6049) OCF-294-02-01 IMES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction h aterials;Technologies(TST6D49) OCF-338-D2-DI ASTM D 1970 2015a 'Determined to be i quivalent to ASTM D 226-09,Type II PRODUCT DESC PTION TRI-BUILT Gran flar A self-adhered underlayment used as an alternative to ASTM D 226,Type II roofing felt. Underlayment The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls vw-fh nominal dimensions of 3-ft x 65-ft. See manufacturer's installation instructions for further detail. t3GR2000T fL34539 Page.T Of 3 This evaluation re rt is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation rer Drt does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically adaresi ed herein. G R K c/o OWENS CORNING SALES ACQUISITIONS,INC. ROOFING AND ASPHALT LLC TECHN AL SERviCES, LLC TRI-BUILT Granular Undeflaynent APPLICATION Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Deck shall be installed in accordance with FBC requirements. Roof decks shalt have no more than 1/8 gap at abutting joints. Min.slope: 2:12 or in accordance in with FBC Application: Prior to beginning installation, the undertayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment installation shall comply with FBC Table 1507.1.1.1. 1 The underlayment shall be installed with the roll length parallel to the save,stetting at the eave fold the underlayment away from save onto itself. The underlayment shall be installed direct-to-decking with the lower release backer removed and pressed firmly into place to ensure complete.contact with the-deck. Repeat with upper release backer. Overlap successive courses with minimum 3"side laps and minimum 6"staggered end laps. In steep-slope applications (>6:12), it is permissible to nail the underlayment 12- j inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave and overlapped a minimum of 6-inches. For eave protection, the underlayment should extend to a point 18-inches beyond ` the interior wall. Min.Applicator', Temperature: 40'F;Contact the,manufacturer when installing at temperatures below the minimum application temperature. Allowable l oof coverings: Mechanical attachment of asphalt shingles and slate shingles shall be permitted in accordance with the FBC. OCR20001 FL34539 Page 2 of 3 This evaluation re. rt is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addres`ed herein. �"�j BEACON SALES ACQUISITIONS,INC. G D i1 l.�I1 . c%OWENS CORNING ROOFING AND ASPHALT LLC TECHN AL SERvims,LLC TRI-BUILT Granular Underlayment LIMITATIONS 1) This ev iluation report is not for use in the HVHZ. 2) Fire CI sification is not within the scope of this evaluation. 3) Wind u liftrssLstance.in not within scope of this-evaluation. 4) Installa on of the evaluated product shall comply with this report,the FBC,and the manufacturer's published applica on instructions. Where discrepancies exist between these sources, the more restrictive and FBC compl t installation detail shall prevail. 5) Deck s bstrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall bf checked for protrusion and corrected prior to underlayment application. 6) The un erlayment may be used as described in other current FBC product approval documents. 7) Roof erings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastene I through the underlayment to the roof deck. 8) The un. erlayment shall not be installed over existing roof coverings. 9) The un erlayment shall be installed starting at the eave in horizontal layers such that the laps shed water from thi deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a minimu i of 24-inches from the preceding course. 10) The und erlayment shall be exposed on the roof deck for a maximum duration of 30 days. 11) All prod i icts listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 20-3. COMPLIANCE&JATEMENIT The products ev iluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,7th Edition (2020)as evidenced in the referenced documents submitted by the named manufacturer. FA .....:•�°q���i� 2020.10.14 0Fs,.-. 1- 2zF - -04'00' 15:45:22 No 74.021 :' STATE OF :Q/� i0,n'•.� P - 4 .' Zachary R.Priest,P.E. --�F •� O R l�•••G���`� Florida Registration No.74021 Organization No.ANE9641 CERTIFICATION i F INDEPENDENCE CREEK Technical Se vices,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distdbuting products under this evaluation. CREEK Technical Se vices,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.11 does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.1 does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product END OF REPORT OCR20001 FL34539 Page 3 of 3 This evaluation re rt is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Service LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation re rt does not express nor imply warranty,installation, recommended use. or other product attributes that are not specifically addres ed herein.