HomeMy WebLinkAboutEVALUATION REPORT ` O `
11 W 10FIVED REVIE FOR
' CODE CO
JUL 012021ST� L
St.1. i ft County � "tiank,
I-55
p P�� 3�� 13
® oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION O.
East Coast Metals,Inc. Evaluation Report E10240.08.08-R5
7905 W. 20th Avenue FL5374-R6
Hialeah, FL 33014 Date of Issuance:09/03/2008
(305)885-9991 Revision 5:09/29/2020
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7th Edition(2020) Florida Building Code sections noted herein.
DESCRIPTION: TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEIVIO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen P.E. ^"", •�,;�.5 ^�;; '=,: The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 09/29/2020.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019,NEMO ETC,LLC
>
NMEMO etc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: TRIMLOCK and TRIMLOCK PLUS,as produced by East Coast Metals,have demonstrated
compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/Conditions of Use set forth herein.
STANDARDS:
Section Property Standard Year
1507.3.7 Installation,non-HVHZ FRSA/TRI(09-18) 2018
1518.8.1 Installation,HVHZ RAS 118,119&120 2020
1523.6.5.2.2 Static uplift resistance TAS 101 1995
1504.2.1.1 Overturning resistance SBCCI SSTD 11 1997
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Static Uplift Resistance E42730.08.13 08/23/2013
ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015
ERD(TSTG049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015
Florida TEC(TST7393) TAS 101 S10-628R 10/27/2010
NEMO(TST6049) Tensile adhesion 4i-ECM-20-SSCRT 09/29/2020
PRI(TST5878) TAS 101 ECM-001-02-01 09/21/2001
PRI(TST5878) TAS 101 ECM-003-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-004-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-006-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-008-02-01 06/13/2008
East Coast Metals Metal Quality Mill Certifications Various
Intertek/ATI(QUA1844) Quality Control Participation Letter 03/11/2015
Intertek/ATI(QUA1844) Quality Control Florida BCIS Current
PRODUCT4. DESCRIPTION:
4.1 TRIMLOCK:
Pre-formed metal channel designed for use as a hip and ridge
base to which roof tiles are bonded in FBC Approved roof the
adhesive. TRIMLOCK is characterized by its profiled and
perforated upper horizontal flange designed to receive and
allow for interlock with the overlying tile adhesive. a
TRIMLOCK is available in 119-3/8-inch (+3/8")length by 3,3.5, m
4,5 or 6-inch(+3/8-inch)heights with 1.5-inch(+1/16-inch)
deck-flanges.
NEW ETC,LLC Evaluation Report E10240.08.08-RS
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6
TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020
Page 2 of 7
L y
NNEMO etc.
4.2 TRIMLOCK PLUS:
Pre-formed metal channel designed for use as a hip and ridge
base to which roof tiles are bonded in FBC Approved roof tile
adhesive. TRIMLOCK PLUS is characterized by its profiled and
perforated upper horizontal flange designed to receive and
allow for interlock with the overlying tile adhesive and its
perforated deck flanges,designed for installation atop the roof ��
underla ment via placement in FBC Approved roof tile adhesive,
Y P P P
which flows-through and interlocks with the underlying � o
adhesive.
TRIMLOCK PLUS is available in 119-3/8-inch(+3/8")length by 3,
3.5,4,5 or 6-inch(+3/8-inch)heights with 1.5-inch(+1/16-inch) '
deck-flanges.
Cd1y
4.4 TRIMLOCK and TRIMLOCK PLUS are fabricated of the following metals:
➢ Galvalume Steel: Min.0.019+0.002-inch,ASTM A792,AZ55,min.35 KSI.
➢ Aluminum: Min.0.032+0.002-inch,ASTM B209,3003-1-114,min.21 KSI.
➢ Stainless Steel: Min.0.019+0.002-inch,ASTM A240/A480,T304,min.35 KSI.
5. WITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or R902 for
requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and
limitations concerning the use of foam plastic insulation.
5.4 This Evaluation Report does not include evaluation of roof edge termination.
5.5 HVHZ JURISDICTIONS(e.g.,Broward and Miami-Dade Counties):
5.5.1 For TRIMLOCK,refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,Drawing 12, Detail 3;or RAS 120,Drawing 15,
Detail 3. For TRIMLOCK PLUS,refer to the installation instructions herein.
5.5.2 Installations of TRIMLOCK are prescriptive by RAS 118, 119 and 120, and the data in Tables 1A and 1B is
supplemental to these prescriptive allowances.
Installations of TRIMLOCK PLUS are limited to projects having a required moment resistance (Mr) or uplift
resistance(F,),as determined in accordance with RAS 127,not greater than the data in Tables 1A and 1B.
NEMO ETC,LLC Evaluation Report E10240.08.08-RS
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6
TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020
Page 3 of 7
NMEMO I etc.
TABLE ZA: PERFORMANCE LIMITATIONS—HVHZ
INDEPENDENT PADDY PLACEMENT(MARGIN OF SAFETY ALREADY APPLIED)
Hip&Ridge Anchor Adhesive Allowable Performance
Tile Placement Moment Based Uplift Based
Design Metal Type Type (See 5.7) Mf(ft-Ibf) F'(Ibf)
Galvalume°, ICP Adhesives&Sealants"Polyset
TRIMLOCK aluminum or clay or AH-160"or DAP Foam"Touch'n Seal Independent 171 159
stainless steel concrete StormBond 2 Two-Component Roof
Tile Adhesive"
Galvalume®, ICP Adhesives&Sealants"Polyset
TRIMLOCK aluminum or clay or AH-160" or DAP Foam"Touch'n Independent 177 165
PLUS stainless steel concrete Seal StormBond 2 Two-Component
Roof Tile Adhesive"
TABLE 1B: PERFORMANCE LIMITATIONS—HVHZ
INTERDEPENDENT PADDY PLACEMENT MARGIN OF SAFETY ALREADY APPLIED)
Hip&Ridge Anchor Adhesive Allowable Performance
Design Metal Type
Tile Type Placement Moment Based Uplift Based
(See 5.7) Mf(ft-Ibf) F'(Ibf)
TRIMLOCK Galvalumea ICP Adhesives&Sealants"Polyset
or , clay or AH-160"or DAP Foam"Touch'n
TRIMLOCK aluminum or concrete Seal StormBond 2 Two-Component Interdependent 95 88
PLUS stainless steel Roof Tile Adhesive"
TRIMLOCK Galvalume®, clay or ICP Adhesives&Sealants"Polyset Interdependent 99 94
stainless steel concrete RTA-1"
TRIMLOCK aluminum clay or ICP Adhesives&Sealants"Polyset Interdependent 90 84
concrete RTA-1"
®,
TRIMLOCK Galvalume clay or ICP Adhesives&Sealants"Polyset
PLUS aluminum or concrete RTA-1" Interdependent 90 84
stainless steel
TRIMLOCK Galvalume®or clay or DuPont de Nemours"TILE BOND" Interdependent 123 117
stainless steel concrete Roof Tile Adhesive"
TRIMLOCK aluminum clay or DuPont de Nemours"TILE BOND'" Interdependent 79 73
concrete Roof Tile Adhesive"
Galvalume®,
TRIMLOCK aluminum or clay or DuPont de Nemours"TILE BOND""
Interdependent 79 73
stainless steel
PLUS concrete Roof Tile Adhesive"
TRIMLOCK Galvalume®or clay or DAP Foam DAP Foam"Touch'n Seal Interdependent 146 139
stainless steel concrete StormBond Roof Tile Adhesive"
TRIMLOCK Aluminum clay or DAP Foam DAP Foam"Touch'n Seal Interdependent 58 54
concrete StormBond Roof Tile Adhesive"
TRIMLOCK Galvalume®, clay or DAP Foam DAP Foam"Touch'n Seal
PLUS aluminum or concrete StormBond Roof Tile Adhesive" Interdependent 58 54
stainless steel
NEMO ETC,LLC Evaluation Report E30240.08.08-R5
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6
TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020
Page 4 of 7
ONEMOletc.
5.6 NON-HVHZ JURISDICTIONS:
5.6.1 For TRIMLOCK,refer to FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition.
For TRIMLOCK PLUS, refer to the installation instructions herein
5.6.2 Installations are limited to projects having hip and ridge design pressure requirements,determined in accordance
with Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, not
greater than the following values.
TABLE 2A: PERFORMANCE LIMITATIONS—NON-HVHZ
INDEPENDENT PADDY PLACEMENT MARGIN OF SAFETY ALREADY APPLIED)
Hip&Ridge Anchor Adhesive
Tile Placement Allowable
Design Metal Type Type (See 5.7) Uplift(psf)
Galvalume®, ICP Adhesives&Sealants"Polyset AH-160"or
TRIMLOCK aluminum or clay re DAP Foam"Touch'n Seal StormBond 2 Two- Independent 173
stainless steel concrete Component Roof Tile Adhesive"
Galvalume®, ICP Adhesives&Sealants"Polyset AH-160"or
TRIMLOCK PLUS aluminum or clay re DAP Foam"Touch'n Seal StormBond 2 Two- Independent 178
stainless steel concrete Component Roof Tile Adhesive"
TABLE 2113: PERFORMANCE LIMITATIONS—NON-HVHZ
INTERDEPENDENT PADDY PLACEMENT MARGIN OF SAFETY ALREADY APPLIED)
Hip&Ridge Anchor Adhesive
Tile Placement Allowable
Design Metal Type Type (See 5.7) Uplift(psf)
Galvalume®, ICP Adhesives&Sealants"Polyset AH-160"or
TRIMLOCK PLUS
TRIMLOCK or aluminum or clay re DAP Foam"Touch'n Seal StormBond 2 Two- Interdependent 98
stainless steel concrete Component Roof Tile Adhesive"
TRIMLOCK Galvalume®or clay or ICP Adhesives&Sealants"Polyset,RTA-1" Interdependent 110
stainless steel concrete
TRIMLOCK aluminum clay or ICP Adhesives&Sealants"Polyset RTA-1" Interdependent 93
concrete
Galvalume®, clay or
TRIMLOCK PLUS aluminum or ICP Adhesives&Sealants"Polyset RTA-1" Interdependent 93
stainless steel concrete
TRIMLOCK Galvalume®or clay or DuPont de Nemours"TILE BOND'"Roof Tile Interdependent 152
stainless steel concrete Adhesive"
TRIMLOCK aluminum clay or DuPont de Nemours"TILE BOND'"Roof Tile Interdependent 82
concrete Adhesive"
Galvalume®, clay or DuPont de Nemours"TILE BOND"Roof Tile
TRIMLOCK PLUS aluminum or Interdependent 82
stainless steel concrete Adhesive"
Galvalume®or clay or DAP Foam DAP Foam"Touch'n Seal StormBond
TRIMLOCK stainless steel concrete Roof Tile Adhesive" Interdependent 148
clay or DAP Foam DAP Foam"Touch'n Seal StormBond
TRIMLOCK Aluminum Interdependent 61
concrete Roof Tile Adhesive"
Galvalume®, clay or DAP Foam DAP Foam"Touch'n Seal StormBond
TRIMLOCK PLUS aluminum or Interdependent 61
stainless steel concrete Roof Tile Adhesive"
MEMO ETC,LLC Evaluation Report E10240.08.08-115
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6
TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020
Page 5 of 7
NNEMO I etc.
5.7 Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT"paddy placement: Each individual tile is bonded to the hip&ridge anchor in its own,single
foam paddy or continuous foam ribbon; tile head laps are not bonded. Allowable performance data for
"INDEPENDENT"paddy placement has a 2 to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement: Each individual tile is bonded to the hip & ridge anchor in a foam
paddy,and a second foam paddy bonds the tile head lap,or two tiles are bonded to the hip& ridge anchor
using a single foam paddy. Allowable performance data for"INTERDEPENDENT"paddy placement has a 4 to
1 margin of safety applied to ultimate performance.
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ)
attached in accordance with FBC Chapter 23 to the satisfaction of the Authority Having Jurisdiction.
6.2 TRIMLOCK or TRIMLOCK PLUS shall be free of dust, debris, oils or other bond-breaking substance prior to
placement of adhesive.
6.3 TRIMLOCK shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch head diameter galvanized annular ring
shank nails spaced 6-inch o.c.along both deck-flanges. Fasteners shall be positioned%-inch from the outside edge
of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RAS 118, Drawing 13, Detail 3;
RAS 119, Drawing 12, Detail 3;or RAS 120, Drawing 15, Detail 3.
6.4 TRIMLOCK PLUS shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile
adhesive centered beneath each 1.5-inch wide deck flange. Place the TRIMLOCK PLUS into the wet adhesive and
allow it to set-up prior to installation of roof tiles.
i
View of Tile Adhesive Placement for TRIMLOCK PLUS Installation
6.4.1 It is critical that the bond between the TRIMLOCK PLUS,the tile adhesive and the underlayment is not disturbed
prior to or during placement of the ridge tiles.
NEMO ETC,LLC Evaluation Report E30240.08.08-RS
Certificate of Authorization a32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6
TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020
Page 6 of 7
ONEMOletc.
6.4.2 Data herein for TRIMLOCK PLUS relates to installation over a TWO-PLY underlayment system, as detailed in the
FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, using a hot-asphalt-
applied,ASTM D6380,Class M cap sheet(commonly called a'30/90 system').
Alternate underlayment systems are those having a current Florida Statewide Product Approval and/or approved
on a local-level by the Authority Having Jurisdiction, listed specifically for use with the selected Approved tile
adhesive.
6.5 Tile shall be installed atop the hip&ridge anchor in accordance with the tile adhesive manufacturer's Approved,
published installation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall
be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or RAS 118, RAS 119, RAS 120
requirements.
Hip/Rid'e Tile
c:::::ii E i
Tile Adhesive
Trim Lock Phis
Mortar or Weather Block
t:...+ r; :�.
' Adhesive
�+' ��°�` ��°• + � Tile Adhesive
View of TRIMLOCK PLUS Installation after Weather Blocked
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Hialeah, FL
QUALITY9.
Architectural Testing,Inc.,an Intertek Company—QUA1844;(847)718-6307; naura.alcheikh@intertek.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report E10240.08.08-R5
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-116
TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020