Loading...
HomeMy WebLinkAboutEVALUATION REPORT ` O ` 11 W 10FIVED REVIE FOR ' CODE CO JUL 012021ST� L St.1. i ft County � "tiank, I-55 p P�� 3�� 13 ® oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION O. East Coast Metals,Inc. Evaluation Report E10240.08.08-R5 7905 W. 20th Avenue FL5374-R6 Hialeah, FL 33014 Date of Issuance:09/03/2008 (305)885-9991 Revision 5:09/29/2020 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition(2020) Florida Building Code sections noted herein. DESCRIPTION: TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEIVIO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen P.E. ^"", •�,;�.5 ^�;; '=,: The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 09/29/2020.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02019,NEMO ETC,LLC > NMEMO etc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: TRIMLOCK and TRIMLOCK PLUS,as produced by East Coast Metals,have demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein. STANDARDS: Section Property Standard Year 1507.3.7 Installation,non-HVHZ FRSA/TRI(09-18) 2018 1518.8.1 Installation,HVHZ RAS 118,119&120 2020 1523.6.5.2.2 Static uplift resistance TAS 101 1995 1504.2.1.1 Overturning resistance SBCCI SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015 ERD(TSTG049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015 Florida TEC(TST7393) TAS 101 S10-628R 10/27/2010 NEMO(TST6049) Tensile adhesion 4i-ECM-20-SSCRT 09/29/2020 PRI(TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI(TST5878) TAS 101 ECM-003-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-004-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-006-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-008-02-01 06/13/2008 East Coast Metals Metal Quality Mill Certifications Various Intertek/ATI(QUA1844) Quality Control Participation Letter 03/11/2015 Intertek/ATI(QUA1844) Quality Control Florida BCIS Current PRODUCT4. DESCRIPTION: 4.1 TRIMLOCK: Pre-formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof the adhesive. TRIMLOCK is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. a TRIMLOCK is available in 119-3/8-inch (+3/8")length by 3,3.5, m 4,5 or 6-inch(+3/8-inch)heights with 1.5-inch(+1/16-inch) deck-flanges. NEW ETC,LLC Evaluation Report E10240.08.08-RS Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6 TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020 Page 2 of 7 L y NNEMO etc. 4.2 TRIMLOCK PLUS: Pre-formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. TRIMLOCK PLUS is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges,designed for installation atop the roof �� underla ment via placement in FBC Approved roof tile adhesive, Y P P P which flows-through and interlocks with the underlying � o adhesive. TRIMLOCK PLUS is available in 119-3/8-inch(+3/8")length by 3, 3.5,4,5 or 6-inch(+3/8-inch)heights with 1.5-inch(+1/16-inch) ' deck-flanges. Cd1y 4.4 TRIMLOCK and TRIMLOCK PLUS are fabricated of the following metals: ➢ Galvalume Steel: Min.0.019+0.002-inch,ASTM A792,AZ55,min.35 KSI. ➢ Aluminum: Min.0.032+0.002-inch,ASTM B209,3003-1-114,min.21 KSI. ➢ Stainless Steel: Min.0.019+0.002-inch,ASTM A240/A480,T304,min.35 KSI. 5. WITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or R902 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.4 This Evaluation Report does not include evaluation of roof edge termination. 5.5 HVHZ JURISDICTIONS(e.g.,Broward and Miami-Dade Counties): 5.5.1 For TRIMLOCK,refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,Drawing 12, Detail 3;or RAS 120,Drawing 15, Detail 3. For TRIMLOCK PLUS,refer to the installation instructions herein. 5.5.2 Installations of TRIMLOCK are prescriptive by RAS 118, 119 and 120, and the data in Tables 1A and 1B is supplemental to these prescriptive allowances. Installations of TRIMLOCK PLUS are limited to projects having a required moment resistance (Mr) or uplift resistance(F,),as determined in accordance with RAS 127,not greater than the data in Tables 1A and 1B. NEMO ETC,LLC Evaluation Report E10240.08.08-RS Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6 TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020 Page 3 of 7 NMEMO I etc. TABLE ZA: PERFORMANCE LIMITATIONS—HVHZ INDEPENDENT PADDY PLACEMENT(MARGIN OF SAFETY ALREADY APPLIED) Hip&Ridge Anchor Adhesive Allowable Performance Tile Placement Moment Based Uplift Based Design Metal Type Type (See 5.7) Mf(ft-Ibf) F'(Ibf) Galvalume°, ICP Adhesives&Sealants"Polyset TRIMLOCK aluminum or clay or AH-160"or DAP Foam"Touch'n Seal Independent 171 159 stainless steel concrete StormBond 2 Two-Component Roof Tile Adhesive" Galvalume®, ICP Adhesives&Sealants"Polyset TRIMLOCK aluminum or clay or AH-160" or DAP Foam"Touch'n Independent 177 165 PLUS stainless steel concrete Seal StormBond 2 Two-Component Roof Tile Adhesive" TABLE 1B: PERFORMANCE LIMITATIONS—HVHZ INTERDEPENDENT PADDY PLACEMENT MARGIN OF SAFETY ALREADY APPLIED) Hip&Ridge Anchor Adhesive Allowable Performance Design Metal Type Tile Type Placement Moment Based Uplift Based (See 5.7) Mf(ft-Ibf) F'(Ibf) TRIMLOCK Galvalumea ICP Adhesives&Sealants"Polyset or , clay or AH-160"or DAP Foam"Touch'n TRIMLOCK aluminum or concrete Seal StormBond 2 Two-Component Interdependent 95 88 PLUS stainless steel Roof Tile Adhesive" TRIMLOCK Galvalume®, clay or ICP Adhesives&Sealants"Polyset Interdependent 99 94 stainless steel concrete RTA-1" TRIMLOCK aluminum clay or ICP Adhesives&Sealants"Polyset Interdependent 90 84 concrete RTA-1" ®, TRIMLOCK Galvalume clay or ICP Adhesives&Sealants"Polyset PLUS aluminum or concrete RTA-1" Interdependent 90 84 stainless steel TRIMLOCK Galvalume®or clay or DuPont de Nemours"TILE BOND" Interdependent 123 117 stainless steel concrete Roof Tile Adhesive" TRIMLOCK aluminum clay or DuPont de Nemours"TILE BOND'" Interdependent 79 73 concrete Roof Tile Adhesive" Galvalume®, TRIMLOCK aluminum or clay or DuPont de Nemours"TILE BOND"" Interdependent 79 73 stainless steel PLUS concrete Roof Tile Adhesive" TRIMLOCK Galvalume®or clay or DAP Foam DAP Foam"Touch'n Seal Interdependent 146 139 stainless steel concrete StormBond Roof Tile Adhesive" TRIMLOCK Aluminum clay or DAP Foam DAP Foam"Touch'n Seal Interdependent 58 54 concrete StormBond Roof Tile Adhesive" TRIMLOCK Galvalume®, clay or DAP Foam DAP Foam"Touch'n Seal PLUS aluminum or concrete StormBond Roof Tile Adhesive" Interdependent 58 54 stainless steel NEMO ETC,LLC Evaluation Report E30240.08.08-R5 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6 TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020 Page 4 of 7 ONEMOletc. 5.6 NON-HVHZ JURISDICTIONS: 5.6.1 For TRIMLOCK,refer to FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. For TRIMLOCK PLUS, refer to the installation instructions herein 5.6.2 Installations are limited to projects having hip and ridge design pressure requirements,determined in accordance with Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, not greater than the following values. TABLE 2A: PERFORMANCE LIMITATIONS—NON-HVHZ INDEPENDENT PADDY PLACEMENT MARGIN OF SAFETY ALREADY APPLIED) Hip&Ridge Anchor Adhesive Tile Placement Allowable Design Metal Type Type (See 5.7) Uplift(psf) Galvalume®, ICP Adhesives&Sealants"Polyset AH-160"or TRIMLOCK aluminum or clay re DAP Foam"Touch'n Seal StormBond 2 Two- Independent 173 stainless steel concrete Component Roof Tile Adhesive" Galvalume®, ICP Adhesives&Sealants"Polyset AH-160"or TRIMLOCK PLUS aluminum or clay re DAP Foam"Touch'n Seal StormBond 2 Two- Independent 178 stainless steel concrete Component Roof Tile Adhesive" TABLE 2113: PERFORMANCE LIMITATIONS—NON-HVHZ INTERDEPENDENT PADDY PLACEMENT MARGIN OF SAFETY ALREADY APPLIED) Hip&Ridge Anchor Adhesive Tile Placement Allowable Design Metal Type Type (See 5.7) Uplift(psf) Galvalume®, ICP Adhesives&Sealants"Polyset AH-160"or TRIMLOCK PLUS TRIMLOCK or aluminum or clay re DAP Foam"Touch'n Seal StormBond 2 Two- Interdependent 98 stainless steel concrete Component Roof Tile Adhesive" TRIMLOCK Galvalume®or clay or ICP Adhesives&Sealants"Polyset,RTA-1" Interdependent 110 stainless steel concrete TRIMLOCK aluminum clay or ICP Adhesives&Sealants"Polyset RTA-1" Interdependent 93 concrete Galvalume®, clay or TRIMLOCK PLUS aluminum or ICP Adhesives&Sealants"Polyset RTA-1" Interdependent 93 stainless steel concrete TRIMLOCK Galvalume®or clay or DuPont de Nemours"TILE BOND'"Roof Tile Interdependent 152 stainless steel concrete Adhesive" TRIMLOCK aluminum clay or DuPont de Nemours"TILE BOND'"Roof Tile Interdependent 82 concrete Adhesive" Galvalume®, clay or DuPont de Nemours"TILE BOND"Roof Tile TRIMLOCK PLUS aluminum or Interdependent 82 stainless steel concrete Adhesive" Galvalume®or clay or DAP Foam DAP Foam"Touch'n Seal StormBond TRIMLOCK stainless steel concrete Roof Tile Adhesive" Interdependent 148 clay or DAP Foam DAP Foam"Touch'n Seal StormBond TRIMLOCK Aluminum Interdependent 61 concrete Roof Tile Adhesive" Galvalume®, clay or DAP Foam DAP Foam"Touch'n Seal StormBond TRIMLOCK PLUS aluminum or Interdependent 61 stainless steel concrete Roof Tile Adhesive" MEMO ETC,LLC Evaluation Report E10240.08.08-115 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6 TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020 Page 5 of 7 NNEMO I etc. 5.7 Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT"paddy placement: Each individual tile is bonded to the hip&ridge anchor in its own,single foam paddy or continuous foam ribbon; tile head laps are not bonded. Allowable performance data for "INDEPENDENT"paddy placement has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement: Each individual tile is bonded to the hip & ridge anchor in a foam paddy,and a second foam paddy bonds the tile head lap,or two tiles are bonded to the hip& ridge anchor using a single foam paddy. Allowable performance data for"INTERDEPENDENT"paddy placement has a 4 to 1 margin of safety applied to ultimate performance. 6. INSTALLATION: 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the Authority Having Jurisdiction. 6.2 TRIMLOCK or TRIMLOCK PLUS shall be free of dust, debris, oils or other bond-breaking substance prior to placement of adhesive. 6.3 TRIMLOCK shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c.along both deck-flanges. Fasteners shall be positioned%-inch from the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3;or RAS 120, Drawing 15, Detail 3. 6.4 TRIMLOCK PLUS shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the TRIMLOCK PLUS into the wet adhesive and allow it to set-up prior to installation of roof tiles. i View of Tile Adhesive Placement for TRIMLOCK PLUS Installation 6.4.1 It is critical that the bond between the TRIMLOCK PLUS,the tile adhesive and the underlayment is not disturbed prior to or during placement of the ridge tiles. NEMO ETC,LLC Evaluation Report E30240.08.08-RS Certificate of Authorization a32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-R6 TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020 Page 6 of 7 ONEMOletc. 6.4.2 Data herein for TRIMLOCK PLUS relates to installation over a TWO-PLY underlayment system, as detailed in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, using a hot-asphalt- applied,ASTM D6380,Class M cap sheet(commonly called a'30/90 system'). Alternate underlayment systems are those having a current Florida Statewide Product Approval and/or approved on a local-level by the Authority Having Jurisdiction, listed specifically for use with the selected Approved tile adhesive. 6.5 Tile shall be installed atop the hip&ridge anchor in accordance with the tile adhesive manufacturer's Approved, published installation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or RAS 118, RAS 119, RAS 120 requirements. Hip/Rid'e Tile c:::::ii E i Tile Adhesive Trim Lock Phis Mortar or Weather Block t:...+ r; :�. ' Adhesive �+' ��°�` ��°• + � Tile Adhesive View of TRIMLOCK PLUS Installation after Weather Blocked 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Hialeah, FL QUALITY9. Architectural Testing,Inc.,an Intertek Company—QUA1844;(847)718-6307; naura.alcheikh@intertek.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report E10240.08.08-R5 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ&HVHZ EVALUATION FL5374-116 TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision 5:09/29/2020 Page 7 of 7