Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOF Florida Building Code Online 7/14/21,11:31 AM BCIS Home I Log In User Registration I Hot Topics ( Submit Surcharge I Stats&Facts i Publications I Contact Us ( BCIS Site Map Links I Search FloridPr RECEIVED l � Product Approval USER:Public User JUL 14 2021 Product Approval Menu>Product or Application Search>Application List>Application Detail .St.IaJCIe County I FL# FL27499-R4 Permitting Application Type Revision Code Version 2020 Application Status Approved REVIEWED FOR Comments Archived rl �✓CODE COMPLIANCE ST. LUCIE C®UNW Product Manufacturer Dynamic Metals ®®CC Address/Phone/Email 3201 SE Dominica Terace ll� Stuart, FL 34997 (772) 872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus �1�� �©�� juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory MetalRoofings., Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C1 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Scott Wolters the Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A.Turner, P.E., MBA F.,1 Validation Checklist- Hardcopy Received Certificate of Independence FL27499 R4 COI_Dyn COI.pdf Referenced Standard and Year(of Standard) Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 1 of 5 Florida Building Code Online 7/14/21,11:31 AM Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2021 Date Validated 04/30/2021 Date Pending FBC Approval 05/03/2021 Date Approved 06/08/2021 Sumiiia_ry of Pro ducts_ .° hp lGo to Pagel Page 1/2 FL# Model, Number or Name Description 27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16"wide,with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4991 Dwg_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R4 LE_4991 Eval.pdf Created by Independent Third Party: Yes 27499.2 DM Class 1000 1" Nailstrip, .032"Aluminum roof panel, 16"wide, with 1"snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4992 Dwq.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE_4992 Eval.pdf Created by Independent Third Party: Yes 27499.3 DM Class 1050 1 1/2" Nailstrip .032"Aluminum Roof Panel, 19" Wide, with 1 1/2"snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II_4993 Dwg.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4_AE_4993 Eval.pdf Created by Independent Third Party: Yes 27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2"snap fit seams Limits of Use Installation Instructions Approved-for use in HVHZ:Yes FL27499 R4_II_4994 Dwa_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4994 Eval.pdf Created by Independent Third Party: Yes 27499.5 DM Class 1150 1" Mechanical Seam .032"Aluminum roof panel, 21"wide, with 1"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4995 Dwg_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE#62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports https://floridabuiIding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 2 of 5 Florida Building Code Online 7/14/21,11:31 AM Other: Please see Eval Report for Limits of Use. FL27499 R4 AE 4995 Eval.pdf Created by Independent Third Party: Yes 27499.6 DM Class 1150 1" Mechanical Seam .032"Aluminum roof panel, 21"wide, with 1"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: No FL27499 R4 II 4996 Dwo_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE#62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499 R4 AE 4996 Eval.pdf Limits of Use. Created by Independent Third Party: Yes 27499.7 DM Class 1150 1" Mechanical Seam 26 Ga. Galvalume coated steel roof panel, 21"wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4_II_4 7 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499 R4 AE 4997 EvaL f Limits of Use. Created by Independent Third Party: Yes 27499.8 DM Class 1500 1 1/2" Mechanical .032"Aluminum roof panel, 20" wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4_II_4998 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4998 Eval.pdf Created by Independent Third Party: Yes 27499.9 DM Class 1500 1 1/2" Mechanical 16 oz. Copper roof panel, 16"wide, with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4999 Dwg.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4_AE_4999 Eval.pdf Created by Independent Third Party: Yes 27499.10 DM Class 1500 1 1/2" Mechanical 26 Ga. galvalume coated steel roof panel, 16"wide, with 1 Seam 1/2"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49910 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE_49910 Eval.pdf Created by Independent Third Party: Yes 27499.11 DM Class 1500 1 1/2" Mechanical .032"Aluminum roof panel, 16"wide, with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4_II_49911 Dwg.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R4 AE_49911 Eval.pdf Created by Independent Third Party: Yes 27499.12 DM Class 1500 1 1/2" Mechanical 24 Ga. galvalume coated steel roof panel, 16"wide, with 1 Seam 1/2"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II_49912 Dwo.odf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 3 of 5 Florida Building Code Online 7/14/21,11:31 AM Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE_49912 Eval.pdf Created by Independent Third Party: Yes 27499.13 DM Class 1500 1 1/2" Mechanical 24 Ga. galvalume coated steel roof panel, 20"wide, with 1 Seam, 1/2"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49913 Dwo. f Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49913 Eval.pdf Created by Independent Third Party: Yes 27499.14 DM Class 1750 1 3/4"Snaplock 24 Ga. Galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams,attached to metal deck. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II_49914 Dwo.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE_49914 Eval.pdf Created by Independent Third Party: Yes 27499.15 DM Class 1750 1 3/4" Snaplock .032"Aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams,attached to metal deck. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II_49915 Dwg_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE_49915 Eval.pdf Created by Independent Third Party: Yes 27499.16 DM Class 1750 1 3/4"Snaplock .032" aluminum roof panel, 18"wide,with 1 3/4"Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49916 Dwg_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R4_AE_49916 Eval.pdf Created by Independent Third Party: Yes 27499.17 DM Class 1750 1 3/4"Snaplock 24 Ga. galvalume coated steel roof panel, 18"wide,with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49917 dwa.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva] report for Limits of Use. FL27499 R4 AE_49917 Eval.pdf Created by Independent Third Party: Yes 27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18"wide, with 2"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49918 Dwo_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE_49918 Eval.pdf Created by Independent Third Party: Yes 27499.19 DM Class 2000 2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 18"wide, with 2" standing seams. Limits of Use Installation Instructions https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 4 of 5 Florida Building Code Online 7/14/21,11:31 AM Approved for use in HVHZ:Yes FL27499 R4 II 49919 Dwa_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE_49919 Eval.pdf Created by Independent Third Party: Yes 27499.20 DM Class 500 5V Crimp 26 Ga. galvalume coated steel roof panel, 24"wide,with 5V crimp. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49920 Dwo_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R4_AE_49920 Eval.pdf Created by Independent Third Party: Yes I GO to Page Page 1/2 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395,*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe https://floridabuiIding.org/pr/pr_app dti.aspx?param=wGEVXQwtDquH0E2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 5 of 5 - i ®M CLASS 1000 V NAILSTRIP 16" WIDE m2, 26 GA, GALVALUME R®®E PANEL (HVHZ) �Ir 16"o.c. aLi °Q .. . ........... 'JS may, E gd� Wood Deck Integral Snap Lock s Pi G Geocel 2300 or 2320 Sealant N ErE J 1� F #10x1" Q =� Pancake-Head Screw w a, (See Eval Report for 3 Fastener Spacing) Lj zmA 0 �m� 16" o LL 314" Panel Profile NSB— ' 1/1 WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING 15211 97th Road N West Palm Beach,FL 33412 Ph/Fx:(561)225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1000 26 GA.GALVALUME 1" NAILSTRIP 16"WIDE ROOF PANEL(FLPA#27499.1) MANUFACTURER: DYNAMIC METALS,LLC 3201 SE DOMINICA TERRACE STUART, FL 34997 To all concerned, The DM Class 1000 Series 26 Ga. Galvalume 1"Nailstrip 16"Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min)that meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been tested per TAS 100,TAS 125, and ASTM E2140 by Intertek B&C with results shown in test reports G3443.40-450- 44,G3443.14-450-44, and M1607.01-450-44. It has also been tested per TAS 110 by PRI Construction Materials Technologies,with results shown in test reports VLS-004-02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing"NSS16-HZ'dated 8116/19,signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc.signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies,signed and sealed by Zachary R Priest, PE. 3. Supplemental Calculations to support NSS16-HZ,signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above,this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 16" (nominal) Fastener Spacing across panel: 16"(at Nailstrip) (Panels overlap with male/female snap fit) Min. Slope: HVHZ: 1712" Non-HVHZ: Y2'712" 5FECIAUZIN6 IN IMPACT F�515fAW CUI:fAINWALU5,5fOUI;ON5, &WINPOW5 Option#1 Option#2 Installation Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6" Max. O.C. Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geocell 2300 Continuous bead of Geocel 2300 or 2320 at Nailstrip side of seam or 2320 at Nailstrip side of seam at roof slopes<3"/12"only) Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ in areas with windspeeds< 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type Il, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ in areas with windspeeds< 170 mph, 1"round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Minimum Substrate: % (15/32" min)4-ply CDX Plywood or%"solid wood planks(S.G. _ .42 min) nailed to 2x rafters spaced 24" max. on center with 8d ring-shank nails spaced 6"on center. Note: The%"wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above,or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5FFCIALIZIN6 IN IMPACT FF515fANf CUKAMM1,5, 5f0FFFP,0Nf5, &WINPOW5 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133. 5. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e),may be used for project specific approval by the local authorities having jurisdiction. 6. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement,"Dynamic Metals FL#27499.1, DM Class 1000". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines,per approval of 3m party QA provider,to the dimensions shown on Drawing NSS16-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re-Roofing: The DM Class 1000 Series 26 Ga. Galvalume 1"Nailstrip 16"Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. I Thank you, 4,e�, `; t�vo� ''�•,f ,• O No 62354 Scott Wolters FL PE#62354° APR 15 21Tt o'•• STATE O F .:/4/ r + ri s`� • ..,.•G��C?�+tea z+ ] >�l68GiE ', 5F CIALIZING IN IMPACTR; 515MNf CTUAINWA15,5f0VF,0Nf5, &WINPOW5