HomeMy WebLinkAboutRevisions OFFICE USE ONLY:
DATE FILED:'\�5�a� PERMIT# �-
REVISION FEE:Br � 5 RECEIPT# A aO
PLANNING & DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION RECEIVED
2300 VIRGINIA AVENUE
FORT PIERCE,FL 34982-5652 JUL 15 2021
(772)462-1553
OL 6dFip GounK'
APPLICATION FOR BUILDING PERMIT REVISIONS Permitting
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
�2) 7 D vt- L 3INr1
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
C a na c T kj 4v)gA 4fa-n ;n R -2 0
CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: R 9 94610 ST.LUCIE CO CERT. #:
BUSINESS NAME:
QUALIFIERS NAME: fn i Chk e t- D i f-CO-oceg W
ADDRESS: Bgqy kw)e5o;7e P v)-c `T ra',L—
CITY: (�i Qi�fce STATE:f[- ZIP: `31/5Y5--
PHONE(DAYTIME): -772- -77g7 FAX:
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION: File Copy
NAME: .L i
ADDRESS: qob tL4ktt,-L P,--e
CITY: (7- P"c+'c r- ST E:, F ZIP: 3 y 6 VS—
PHONE (DAYTIME): , _ ;� ''«t FAX:
dj�
SLCCC: 9123109
Revised 06130117
4; �t,•:4 �t7
;
FORM R405-2020 File Copy
FLORIDA ENERG D R BUILDING CONSTRUCTION
I
Florida Department o usiness and Professional Regulation - Residential Performal l�@thod
Project Name: Melville Residence `�et`r'7s"� r �e�
2021
�+o aA St.Lucie County
Street: 7827 Saba[Lake Drive �d D q _ �33+7 t �• " "'�'�� Permitting
City,State,Zip: Port St.Lucie,FL,34950 O / oP ,�C
Owner: Melville Residence ��Ju ctTy
Design Location: FL,Fort Pierce County:BOMcie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Type43966.7 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead AggR=4.1 3378.70 ft2
b.Frame-Wood,Adjacent R=19.0 588.00 ft
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Types (4148.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 4148.00 ft2
6. Conditioned floor area above grade(ft2) 4148 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
7. Windows(779.1 sqft.) Description Area 12.Ducts R ft2
a. U-Factor: Sgl,U=0.66 524.99 ft2
a.Sup:Attic,Ret:Attic,AH:AHU 6 95
b.Sup: Attic,Ret:Attic,AH:Garage 6 95
SHGC: SHGC=0.21
b. U-Factor: Sgl,U=0.70 180.00 ft2 13.Cooling systems kBtu/hr , Efficiency
SHGC: SHGC=0.58 a.Central Unit 36.0 SEER:17.00
c. U-Factor: Sgl,U=0.24 50.11 ft2 b.Central Unit 36.0 SEER:17.00
SHGC: SHGC=0.15 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 11.246 ft.
Area Weighted Average SHGC: 0.293 a.Electric Strip Heat .0 COP:1.00
34
b.Electric Strip Heat 34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15.Hot water systems
SHGC(AVG): N/A a.Propane Tankless Cap: 1 gallons
9. Floor Types (4148.0 sqft.) Insulation Area EF:0.600
a.Slab-On-Grade Edge Insulation R=0.0 4148.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 16.Credits CF,Pstat
Glass/Floor Area: 0.188 P
Total Proposed Modified Loads: 119.28
Total Baseline Loads: 122.29 PASS
I hereby certify that the plans and specifications covered by Review of the plans and p�'tUE 87,
this calculation are in compliance with the Florida Energy specifications covered by this �'
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed r
DATE: 6- I-20 1 this building will be inspected for d,
compliance with Section 553.908 ,
I herebycertify that this building, as designed, is' om liance Florida Statutes.
fY 9, 9 P
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: 7- '-�� DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory�sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Melville Residence Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 4148 Lot#
Owner Name: Melville Residence Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 7827 Sabal Lake Drive
Permit Office: St.Lucie County Cross Ventilation: No County: St.Lucie
Jurisdiction: St.Lucie County Whole House Fan: No City,State,Zip: Port St.Lucie,
Family Type: Detached FL, 34950
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 (Rest of House) 2020 21210
2 Main Area 2128 24191.6
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Master Bedroom 379 3979.5 No 2 1 1 Yes Yes Yes
2 Exercise 121 1270.5 No 1 1 Yes Yes Yes
3 WIC 2 64 672 No 0 1 Yes Yes Yes
4 Master Bath 203 2131.5 No 1 1 Yes Yes Yes
5 Toilet 24 252 No 0 1 No Yes Yes
6 Bedroom 4 216 2268 No 2 1 1 Yes Yes Yes
7 WIC 1 80 840 No 0 1 No Yes Yes
8 Bath 4 66 693 No 0 1 Yes Yes Yes
9 Bedroom 3 248 2604 No 2 1 1 Yes Yes Yes
10 Bath 3 49 514.5 No 0 1 Yes Yes Yes
11 Bath 70 735 No 0 1 Yes Yes Yes
12 Bath 2 49 514.5 No 0 1 Yes Yes Yes
13 Closet 4 30 315 No 0 1 No Yes Yes
14 Linen 16 168 No 0 1 No Yes Yes
15 AHU 16 168 No 0 1 No Yes Yes
i
16 Hall 39 409.5 No 0 1 No Yes Yes
17 Powder 68 714 No 1 1 No Yes Yes
18 Hall 50 525 No 0 1 No Yes Yes
19 Bedroom 2 232 2436 No 2 1 1 Yes Yes Yes
20 Office 230 2415 No 0 1 Yes Yes Yes
21 Hall 24 252 No 0 1 Yes Yes Yes
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
22 Cabana Bath 60 630 No 0 1 Yes Yes Yes
23 Laundry 112 1176 No 0 1 Yes Yes Yes
24 Den 316 3318 No 1 1 Yes Yes Yes
25 Kitchen 263 2761.5 Yes 1 1 No Yes Yes
26 Dining 407 5168.9 No 0 1 Yes Yes Yes
27 Great Room 414 5299.2 No 1 1 Yes Yes Yes
28 Foyer 156 1638 No 0 1 Yes Yes Yes
29 Pantry 82 861 No 0 1 No Yes Yes
30 Closet 64 672 No 0 1 No Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Master Bedroom 42.8 ft 379 ft2 ____ 1 0 0
2 Slab-On-Grade Edge Insulatio Exercise 27 ft 121 ft2 1 0 0
3 Slab-On-Grade Edge Insulatio WIC 2 7 ft 64 ft2 1 0 0
4 Slab-On-Grade Edge Insulatio Master Bath 18 ft 203 ft2 _e_ 1 0 0
5 Slab-On-Grade Edge Insulatio Toilet 1 ft 24 ft2 1 0 0
6 Slab-On-Grade Edge Insulatio Bedroom 4 15 ft 216 ft2 __-_ 1 0 0
7 Slab-On-Grade Edge Insulatio WIC 1 1 ft 80 ft2 ___ 1 0 0
8 Slab-On-Grade Edge Insulatio Bath 4 6 ft 66 ft2 ____ 1 0 0
9 Slab-On-Grade Edge Insulatio Bedroom 3 18 ft 248 ft2 ____ 1 0 0
10SIab-On-Grade Edge Insulatio Bath 3 14 ft 49 ft2 1 0 0
11Slab-On-Grade Edge Insulatio Bath loft 70 ft2 ____ 1 0 0
12SIab-On-Grade Edge Insulatio Bath 2 14 ft 49 ft2 1 0 0
13SIab-On-Grade Edge Insulatio Closet 4 1 ft 30 ft2 ____ 1 0 0
14SIab-On-Grade Edge Insulatio Linen 1 ft 16 ft2 _e_ 1 0 0
15SIab-On-Grade Edge Insulatio AHU 1 ft 16 ft2 ____ 1 0 0
16SIab-On-Grade Edge Insulatio Hall 3 1 ft 39 ft2 1 0 0
17SIab-On-Grade Edge Insulatio Powder 1 ft 68 ft2 1 0 0
18SIab-On-Grade Edge Insulatio Hall 2 1 ft 50 ft2 1 0 0
19SIab-On-Grade Edge Insulatio Bedroom 2 19 ft 232 ft2 1 0 0
20Slab-On-Grade Edge Insulatio Office 30 ft 230 ft2 _e_ 1 0 0
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
21SIab-On-Grade Edge Insulatio Hall 1 loft 24 ft2 ____ 1 0 0
22SIab-On-Grade Edge Insulatio Cabana Bath loft 60 ft2 __-_ 1 0 0
23SIab-On-Grade Edge Insulatio Laundry 7 ft 112 ft2 ____ 1 0 0
24SIab-On-Grade Edge Insulatio Den 31 ft 316 ft2 1 0 0
25SIab-On-Grade Edge Insulatio Kitchen 1 ft 263 ft2 ____ 1 0 0
26SIab-On-Grade Edge Insulatio Dining 17 ft 407 ft2 ____ 1 0 0
27SIab-On-Grade Edge Insulatio Great Room 18 ft 414 ft2 __-_ 1 0 0
28SIab-On-Grade Edge Insulatio Foyer 8 ft 156 ft2 ---- 1 0 0
29SIab-On-Grade Edge Insulatio Pantry 1 ft 82 ft2 ____ 1 0 0
30SIab-On-Grade Edge Insulatio Closet 1 ft 64 ft2 _--- 1 0 0
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Metal 4638 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.57
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 4148 ft2 N N
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition 2020 Page 4 of 9
( ) Compliant P Software 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) Master Bedroom 0 Blown 379 ft2 0.1 Wood
2 Under Attic(Unvented) Exercise 0 Blown 121 ft2 0.1 Wood
3 Under Attic(Unvented) WIC 2 0 Blown 64 ft2 0.1 Wood
4 Under Attic(Unvented) Master Bath 0 Blown 203 ft2 0.1 Wood
5 Under Attic(Unvented) Toilet 0 Blown 24 ft2 0.1 Wood
6 Under Attic(Unvented) Bedroom 4 0 Blown 216 ft2 0.1 Wood
7 Under Attic(Unvented) WIC 1 0 Blown 80 ft2 0.1 Wood
8 Under Attic(Unvented) Bath 4 0 Blown 66 ft2 0.1 Wood
9 Under Attic(Unvented) Bedroom 3 0 Blown 248 ft2 0.1 Wood
10 Under Attic(Unvented) Bath 3 0 Blown 49 ft2 0.1 Wood
11 Under Attic(Unvented) Bath 0 Blown 70 ft2 0.1 Wood
12 Under Attic(Unvented) Bath 2 0 Blown 49 ft2 0.1 Wood
13 Under Attic(Unvented) Closet 4 0 Blown 30 ft2 0.1 Wood
14 Under Attic(Unvented) Linen 0 Blown 16 ft2 0.1 Wood
15 Under Attic(Unvented) AHU 0 Blown 16 ft2 0.1 Wood
16 Under Attic(Unvented) Hall 3 0 Blown 39 ft2 0.1 Wood
17 Under Attic(Unvented) Powder 0 Blown 68 ft2 0.1 Wood
18 Under Attic(Unvented) Hall 2 0 Blown 50 ft2 0.1 Wood
19 Under Attic(Unvented) Bedroom 2 0 Blown 232 ft2 0.1 Wood
20 Under Attic(Unvented) Office 0 Blown 230 ft2 0.1 Wood
21 Under Attic(Unvented) Hall 1 0 Blown 24 ft2 0.1 Wood
22 Under Attic(Unvented) Cabana Bath 0 Blown 60 ft2 0.1 Wood
23 Under Attic(Unvented) Laundry 0 Blown 112 ft2 0.1 Wood
24 Under Attic(Unvented) Den 0 Blown 316 ft2 0.1 Wood
25 Under Attic(Unvented) Kitchen 0 Blown 263 ft2 0.1 Wood
26 Under Attic(Unvented) Dining 0 Blown 16 ft2 0.1 Wood
27 Under Attic(Unvented) Dining 0 Blown 391 ft2 0 Wood
28 Under Attic(Unvented) Great Room 0 Blown 414 ft2 0 Wood
29 Under Attic(Unvented) Foyer 0 Blown 156 ft2 0.1 Wood
30 Under Attic(Unvented) Pantry 0 Blown 82 ft2 0.1 Wood
31 Under Attic(Unvented) Closet 0 Blown 64 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 NE Exterior Concrete Block-Polystpester Bedro 4.1 17 9 10 6 186.4 ft2 0 0 0.6 0
2 SE Exterior Concrete Block-Polystpeater Bedro 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0
3 NW Exterior Concrete Block-PolysWeater Bedro 4.1 19 0 10 6 199.5 ft2 0 0 0.6 0
_4 NE Exterior Concrete Block-PolystyrEFEccercise 4.1 9 0 10 6 94.5 ft2 0 0 0.6 0
5 SE Exterior Concrete Block-PolystyrEFocercise 4.1 14 0 10 6 147.0 ft2 0 0 0.6 0
6 SW Exterior Concrete Block-PolystyrEFnKercise 4.1 4 0 10 6 42.0 ft2 0 0 0.6 0
7 SE Exterior Concrete Block-PolystyrerWlC 2 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
8 SE Exterior Concrete Block-Polystytcfaster Bath 4.1 11 0 10 6 115.5 ft2 0 0 0.6 0
9 SW Exterior Concrete Block-Polysgdaster Bath 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
10 NE Exterior Concrete Block-Polystyiudroom 4 4.1 1 0 10 6 10.5 ft2 0 0 0.6 0
11 SE Exterior Concrete Block-Polystyfledroom 4 4.1 13 0 10 6 136.5 ft2 0 0 0.6 0
12 SW Exterior Concrete Block-Polystyfi�edroom 4 4.1 1 0 10 6 10.5 ft2 0 0 0.6 0
13 SE Exterior Concrete Block-PolystyrerBath 4 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0
14 NE Exterior Concrete Block-Polysty€iedroom 3 4.1 2 0 10 6 21.0 ft2 0 0 0.6 0
_15 SE Exterior Concrete Block-Polystylitedroom 3 4.1 16 0 10 6 168.0 ft2 0 0 0.6 0
16 SE Exterior Concrete Block-PolystyrerBath 3 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
17 SW Exterior Concrete Block-PolystyrerBath 3 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
18 SW Exterior Concrete Block-Polystyren Bath 4.1 10 0 10 6 105.0 ft2 0 0 0.6 0
19 SW Exterior Concrete Block-PolystyrerBath 2 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
_20 NW Exterior Concrete Block-PolystyrerBath 2 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
_21 SW Exterior Concrete Block-Polystyiedroom 2 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0
_22 NW Exterior Concrete Block-Polysty8edroom 2 4.1 13 0 10 6 136.5 ft2 0 0 0.6 0
_23 SE Exterior Concrete Block-PolystyrerOffice 4.1 5 0 10 6 52.5 ft2 0 0 0.6 0
24 SW Exterior Concrete Block-PolystyrerOffice 4.1 17 0 10 6 178.5 ft2 0 0 0.6 0
_25 NW Exterior Concrete Block-PolystyrerOffice 4.1 8 0 10 6 84.0 ft2 0 0 0.6 0
_26 NE Exterior Concrete Block-Polystyrerflall 1 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0
_27 NW Exterior Concrete Block-PolystyrerHall 1 4.1 4 0 10 6 42.0 ft2 0 0 0.6 0
_28 NW Exterior Concrete Block-Polystjdehana Bath 4.1 10 0 10 6 105.0 ft2 0 0 0.6 0
_29 NW Exterior Concrete Block-Polystyrebaundry 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
_30 NE Exterior Concrete Block-Polystyren Den 4.1 19 0 10 6 199.5 ft2 0 0 0.6 0
31 E Exterior Concrete Block-Polystyren Den 4.1 5 0 10 6 52.5 ft2 0 0 0.6 0
32 SE Exterior Concrete Block-Polystyren Den 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0
_33 NE Exterior Concrete Block-PolystyrerDining 4.1 14 0 12 9 178.5 ft2 0 0 0.6 0
_34 NE Exterior Concrete Block-Polysty&aat Room 4.1 14 9 12 10 189.3 ft2 0 0 0.6 0
_35 SW Exterior Concrete Block-PolystyrerFoyer 4.1 8 0 10 6 84.0 ft2 0 0 0.6 0
36 SW Garage Frame-Wood Laundry 19 16 10.5 168.0 ft2 0.23 0.6 0
37 N Garage Frame-Wood Kitchen 19 12 10.5 126.0 ft2 0.23 0.6 0
38 SW Garage Frame-Wood Kitchen 19 2 10.5 21.0 ft2 0.23 0.6 0
39 N Garage Frame-Wood Kitchen 19 5 10.5 52.5 ft2 0.23 0.6 0
_40 SW Garage Frame-Wood Kitchen 19 5 10.5 52.5 ft2 0.23 0.6 0
_41 N Garage Frame-Wood Pantry 19 7 10.5 73.5 ft2 0.23 0.6 0
_42 SW Garage Frame-Wood Pantry 19 3 10.5 31.5 ft2 0.23 0.6 0
_43 N Garage Frame-Wood Office 19 6 10.5 63.0 ft2 0.23 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Wood Master Bedro None .2 .1 .1 .1 ft2
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 NE 1 Metal Low E Single Yes 0.66 0.21 Y 19.0 ft2 2 ft 7 in 1 ft 4 in None None
2 NE 1 Metal Low-E Single Yes 0.66 0.21 Y 19.5 ft2 2 ft 7 in 1 ft 4 in None None
3 NE 1 Metal Low-E Single Yes 0.66 0.21 Y 27.4 ft2 12 ft 0 in 1 ft 4 in None None
4 SE 2 Metal Low-E Single Yes 0.66 0.21 Y 19.5 ft2 2 ft 7 in 1 ft 4 in None . None
5 NE 4 Metal Low-E Single Yes 0.66 0.21 Y 25.3 ft2 2 ft 7 in 1 ft 4 in None None
6 SE 5 Metal Low-E Single Yes 0.66 0.21 Y 39.1 ft2 2 ft 7 in 1 ft 4 in None None
7 SE 7 Metal Low-E Single Yes 0.66 0.21 Y 10.7 ft2 2 ft 7 in 1 ft 4 in None None
8 SE 8 Metal Low-E Single Yes 0.66 0.21 Y 6.0 ft2 2 ft 7 in 1 ft 4 in None None
9 SE 8 Metal Low-E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft 4 in None None
10 SE 11 Metal Low-E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft 4 in None None
11 SE 13 Metal Low-E Single Yes 0.66 0.21 Y 6.0 ft2 2 ft 7 in 1 ft 4 in None None
12 SE 15 Metal Low-E Single Yes 0.66 0.21 Y 22.5 ft2 2 ft 7 in 1 ft 4 in None None
13 SE 16 Metal Low-E Single Yes 0.66 0.21 Y 4.8 ft2 2 ft 7 in 1 ft 4 in None None
14 SW 18 Metal Low-E Single Yes 0.66 0.21 Y 12.0 ft2 2 ft 7 in 1 ft 4 in None None
15 NW 20 Metal Low E Single Yes 0.66 0.21 Y 4.8 ft2 2 ft 7 in 1 ft 4 in None None
16 SW 21 Metal Low-E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft 4 in None None
17 SW 24 Metal Low-E Single Yes 0.66 0.21 Y 57.0 ft2 9 ft 0 in 1 ft 4 in None None
18 NW 25 Metal Low-E Single Yes 0.66 0.21 Y 19.0 ft2 9 ft 0 in 1 ft 4 in None None
19 NE 26 Metal Low-E Single Yes 0.24 0.15 Y 22.7 ft2 6 ft 0 in 1 ft 4 in None None
20 NW 28 Metal Low-E Single Yes 0.66 0.21 Y 4.0 ft2 2 ft 7 in 1 ft 4 in None None
21 NW 29 Metal Low E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft 4 in None None
22 NE 30 Metal Low-E Single Yes 0.66 0.21 Y 24.0 ft2 12 ft 0 in 1 ft 4 in None None
23 NE 30 Metal Low-E Single Yes 0.66 0.21 Y 57.0 ft2 12 ft 0 in 1 ft 4 in None None
24 E 31 Metal Low E Single Yes 0.24 0.15 Y 27.4 ft2 12 ft 0 in 1 ft 4 in None None
25 SE 32 Metal Low-E Single Yes 0.66 0.21 Y 19.0 ft2 12 ft 0 in 1 ft 4 in None None
26 NE 33 Metal Low-E Single Yes 0.7 0.58 Y 90.0 ft2 24 ft 0 in 1 ft 4 in None None
27 NE 33 Metal Low-E Single Yes 0.66 0.21 Y 17.0 ft2 12 ft 0 in 1 ft 4 in None None
28 NE 34 Metal Low-E Single Yes 0.7 0.58 Y 90.0 ft2 24 ft 0 in 1 ft 4 in None None
29 NE 34 Metal Low-E Single Yes 0.66 0.21 Y 17.0 ft2 12 ft 0 in 1 ft 4 in None None
30 NE 34 Metal Low-E Single Yes 0.66 0.21 Y 18.4 ft2 12 ft 0 in 1 ft 4 in None None
31 SW 35 Wood Low-E Single Yes 0.28 0.26 Y 24.0 ft2 12 ft 0 in 1 ft 4 in None None
32 SW 35 Metal Low-E Single Yes 0.66 0.21 Y 16.0 ft2 12 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 864 ft2 864 ft2 53 ft 10.5 ft 19
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 7 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000487 5296.9 290.6 545.57 .1432 7
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1
2 Electric Strip Heat/ None COP:1 34 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER:17 36 kBtu/hr 1080 cfm 0.7 1 sys#1
2 Central Unit/ Split Sing] SEER:17 36 kBtu/hr 1080 cfm 0.7 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
---Supply-- —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 95 ft2 Attic 20 ft2 Default Leakage AHU (Default) (Default) 1 1
2 Attic 6 95 ft2 Attic 25 ft2 Default Leakage Garage (Default) (Default) 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar A r Ma ri Jun ri Jul rl Au ri
Se [ ]Oct [ Nov Dec
Heatin Jan Feb ki
Mar �JA
pr I
j May Jun Jul AuSeP [ ]Oct [ Nov Dec
Ventin Jan Feb Mar Apr May Jun Jul Aug Se [ 1 Oct [X Nov Dec
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 8 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bedroom
Default(8 Ibs/sq.ft. ft2 ft 0.3 Exercise
Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath
Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4
Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 1
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 4
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 4
Default(8 Ibs/sq.ft. ft2 ft 0.3 Linen
Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU
Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 Powder
Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Office
Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1
Default(8 Ibs/sq.ft. ft2 ft 0.3 Cabana Bath
Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry
Default(8 Ibs/sq.ft. ft2 ft 0.3 Den
Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen
Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining
Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room
Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer
Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry
Default(8 Ibs/s .ft. ft2 ft 0.3 Closet
6/9/2021 2:06 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 9 of 9
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Melville Residence Builder Name:
Street: 7827 Sabal Lake Drive Permit Office: St.Lucie County
City,State,Zip: Port St.Lucie,FL,34950 Permit Number: Y
U
Owner: Melville Residence Jurisdiction: St.Lucie County W
Design Location: FL,Fort Pierce
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall .
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind paping and wiring,
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
and walls or ceilin
a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
6/9/2021 2:07 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index,the more efficient the home.
7827 Sabal Lake Drive, Port St. Lucie, FL, 34950
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead AggR=4.1 3378.70 ft2
b.Frame-Wood,Adjacent R=19.0 588.00 ft'
3. Number of units,if multiple family 1 c.N/A R= ft'
4. Number of Bedrooms 4 d.N/A R= ft'
5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a.Roof Deck(Unvented) R=20.0 4148.00 ft2
6. Conditioned floor area(ft� 4148 b.N/A R= ft'
7. Windows- Description Area c.N/A R= ft'
a. U-Factor: Sgl,U=0.66 524.99 ft' a.
Ducts,location&insulation level R ft'
a.Sup:Attic,Ret:Attic,AH:AHU 6 95
SHGC: SHGC=0.21 b.Sup: Attic,Ret:Attic,AH:Garage 6 95
b. U-Factor: Sgl,U=0.70 180.00 ft'
SHGC: SHGC=0.58 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: Sgl,U=0.24 50.11 ft' a.Central Unit 36.0 SEER:17.00
SHGC: SHGC=0.15 b.Central Unit 36.0 SEER:17.00
d. U-Factor: other(see details) 24.00 ft' 14.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 11.246 ft. b.Electric Strip Heat 34.0 COP:1.00
Area Weighted Average SHGC: 0.293
8. Skylights Description Area 15.Hot water systems
ons
a. U-Factor(AVG): N/A ' a.Propane Cap: 1 EFII
ft 0.6
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Ede Insulation R=0.0 4148.00 ft'
g Credits(Performance method) CF,Pstat
b.N/A R= ft'
c.N/A R= ft'
certify that this home has complied with the Florida Energy Efficiency Code for Building 'ou S7,q
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. n�,, r{� ''•, "
Builder Signature: Date:
Address of New Home: Zip:
WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/9/2021 2:07 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1