HomeMy WebLinkAboutRevisions (2) - REVIEWED FOR - - wrightsoft Project Summary db& COMPLIANCEDate: Main Area JUST5 LUCIE C®UNW- Quick Calcs, Inc. y B®CC St.Lucie Count 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com Permifting Project i • • For: Melville Residence 7827 Sabal Lake Drive, Port St. Lucie, FL 34950 Notes: p-C-r-yn;'r' oZ 00R E V I%f".3%)10 IN Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28586 Btuh Structure 27837 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28586 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 26445 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3531 Btuh Ducts 2451 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft� 2128 2128 Equipment latent load 5982 Btuh Volume(ft3) 24203 24203 Air changes/hour 0.21 0.11 Equipment Total Load(Sen+Lat) 32428 Btuh Equiv.AVF(cfm) 86 46 Req.total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ACB736AO0310 AHRI ref Coil FV4CNB006L AHRI ref 10359713 Efficiency 100 EFF Efficiency 13.0 EER, 17 SEER Heating input 11.3 kW Sensible cooling 25200 Btuh Heating output 38419 Btuh Latent cooling 10800 Btuh Temperature rise 29 °F Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wrlg�tsoft--- R ghtS 2021-Jun-09 14:01:37uite®Universsl 2019 19.0.21 RSU08101 Pagel ..t HVAC\Melville Residence-revised 2020 code.rup Calc=MJB Front Door faces:Sw Project Summary Jo - wrightsoft° Unit#2 Date: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772466-6799 Email:quickcalcs@aol.com Project Information For: Melville Residence 7827 Sabal Lake Drive, Port St. Lucie, FL 34950 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 28514 Btuh Structure 22748 Btuh Ducts 4450 Btuh Ducts 3030 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32964 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24489 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5212 Btuh Ducts 2328 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft� 2020 2020 Equipment latent load 7540 Btuh Volume(ft3) 21210 21210 Air changes/hour 0.36 0.19 Equipment Total Load(Sen+Lat) 32029 Btuh Equiv.AVF(cfm) 126 67 Req.total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ACB736AO0310 AHRI ref Coil FV4CNB006L AHRI ref 10359713 Efficiency 100 EFF Efficiency 13.0 EER, 17 SEER Heating input 9.2 kW Sensible cooling 25200 Btuh Heating output 31252 Btuh Latent cooling 10800 Btuh Temperature rise 24 °F Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Pli-wr1ght8of1t- 2021-Jun-09 14:01:37 RightSuite®Universal 2019 19.0.21 RSU08101 Paget .A HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW f - wrightsoft° Right-J® Worksheet Job: Main Area Date: Quick Calcs, Inc. By: 317 St,Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Main Area Office 2 Exposed wall 131.0 ft 30.0 ft 3 Room height 11.4 it 10.5 it heat/cool 4 Room dimensions 1.0 x 230.0 It 5 Room area 2128.0 ft' 230.0 ft' Ty Construction U-value Or HTM Area (ft0 Load Area (ft2) Load number (Btuh/ft'-° I (Btuh/ft') or perimeter (ft) I (Btuh) I or perimeter (it) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.19 305 267 1067 583 84 65 261 142 1A-r1om 1.270 ne 35.56 43.03 4 0 142 172 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 15 0 533 645 0 0 0 0 1A-rlom 1.270 ne 35.56 43.03 19 0 672 813 19 0 672 813 11 _ 1B-rlfm _ 1.130 ne 0.00 ._ 0.00 _ 0 0 0 _ 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 630 294 1178 644 0 0 0 0 10A-m 1.670 se 46.76 25.31 23 23 1060 574 0 0 0 0 10A-m 1.670 se 46.76 25.31 24 24 1122 608 0 0 0 0 1A-rlom 1:270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 34 34 738 661 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 18 18 392 351 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 57 57 1222 1095 0 0 0 0 4A5-2om -. 0.770 _se _ 21.56_- 19.31 180_ __ 180 3881 3475 0 0 _ 0 _ 0 18A-4ocs 0.143 s 4.00 2.19 53 25 101 55 0 0 0 0 4A5-2om__ _,. _. _0.770- s 21.56 _ ,19.31 ._ 27.-___ . 27. _ ___589 _ __ 527 . 0 _ 0 _.- _ 0 0 13A-4ocs 0.143 sw 4.00 2.19 126 107 429 234 53 53 210 115 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 113-r1fm 1.130 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om __ 0.770_ sw 21.56 ___19.31 _ 19_ _ 19 _ _ 407 _ 365 0 „ 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 263 166 664 363 179 122 488 266 10A-f 0.700 nw 19.60 28.93 24 0 470 694 0 0 0 0 1A-rlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 57 0 2016 2440 57 0 2016 2440 1B-rlfm 1.130 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm _ 1.130 _nw 31.64 41.61 16 0 506 666 __ 0 0 0 0 C 16X19-0md - _ 0.408 1.59 1.37 .1323 _ 1323 2 1810 230 230 365 3150 _ C 17B-6a1. .0.105 2.94 4.30 1025 .3014 4413 .. _ . 0 _ _0 _ 0 __- _ f0 F _ 22A-tol_ _-_ 0.989 _- 27.69 0.00 2128 131 3628 - 0 __ 230 30 831 0- 61 c)AED excursion 3461 1 1 1568 Envelope loss/gain 25931 21535 4842 4660 12 a) Infiltration 2655 762 608 174 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 8 1840 2 460 Appliances/other 3700 0 Subtotal(lines 6 to 13) 28586 27837 5450 5294 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28586 27837 5450 5294 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Tot�l 294 Air equi d(cfm) I room load2586 18200I 21200 I 5017837 5229I 5228I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlstvt I*- 2021-Jun-0914:01:37 lrC�YC A ^" Right-Suite®Universal 2019 19.0.21 RSU08101 Pagel t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW -+ wrightsoft, Right-J® Worksheet Job: Main Area Date: Quick Calcs, Inc. By: 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcaics@aol.com 1 Room name Hall 1 Cabana Bath 2 Exposed wall 10.0 ft 10.0 ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 6.0 x 4.0 ft 6.0 x 10.0 ft 5 Room area 24.0 ft' 60.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhfft;° I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 VJ 13A-4ocs 0.143 ne 4.00 2.19 42 42 168 92 105 101 404 221 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 4 0 142 172 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 IA-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 11 16 rlfm ._. 1.130 ne 0.00 ._ 0.00 _ 0 0 0 0 _ _ 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 63 40 161 88 0 0 0 0 10A-m 1.670 se 46.76 25.31 23 23 1060 574 0 0 0 0 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om__-_ 0.770 se_ 21.56__. 19.31 0 0 _0 0 0 0 0 0 V�J 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 4A572om.__ 0.770_.s 21.56 19.31 0 _ _ 0 -0 0 . . 0 _ 0 . 0 _ _ 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm 1.130 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 10A-f 0.700 nw 19.60 28.93 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 B-rlfm ._ _ 1.130._nw 31.64 _ 41.61 0 0- _ _ _. 0 0_ 0 0 0 0 C _ 16X19-0md 0.408_ - 1.59 1.37 24 24_ 38 33 60 60 95 82 C 176 6al _ 0.105 2.94 __ 4.30 0 0 0. 0 0 0 0 0 F __ 22AADI 0.989 27.69 0.00 24 _ 10 277 0 60 10 277 0 61 c)AED excursion 1 1 -29 1 1 1 18 Envelope loss/gain 1 1705 758 1 1 919 457 12 a) Infiltration 203 58 203 58 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1907 816 1121 515 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1907 816 1121 515 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Air requir dl(cfm) I 1980 835I I I 11 2 oad071 47I 52I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f* wr�gf,tteaptl t- 2021-Jun-09 14:01:37 �+ RightSuite®Universal 2019 19.0.21 RSU08101 Paget t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW - wrightsoft• Right-JO Worksheet Job: Main Area Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772466-6799 Email:quickcalcs@aol.com 1 Room name Laundry Den 2 Exposed wall 7.0 ft 31.0 ft 3 Room height 10.5 ft heaUcool 10.5 ft heat/cool 4 Room dimensions 16.0 x 7.0 ft 1.0 x 316.0 ft 5 Room area 112.0 ft' 316.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft') Load number (Btuh/ftU* I (Btuhlft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13A-flocs - 0.143 ne 4.00 2.19 74 LL 59 234 128 0 0 0 _ O 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1,270 ne 35.56 43.03 15 0 533 645 0 0 0 0 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 11 1B_rlfm 1.130 ne 0.00 _ 0.00 .0 _ _0 0 _0 _ 0 __. 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 200 119 476 260 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 1OA-m 1.670 se 46.76 25.31 0 0 0 0 24 24 1122 608 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-20 m 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 57 57 1222 1095 4A5-2om_ _ _ 0.770 se 21.56 19.31 _ _ 0 0 -_-- 0 0 _ _._ 0 0 0 _. 0 V�J '13A-flocs 0.143 s 4.00 2.19 6 0 0 0 53 25 101 55 4A5-2om. _ 0.770 s 21.56 _ 19.31 0 _ 0 0 0 27 _ . . 27 589 527 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 74 55 219 119 IA-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 0.00 0.00 0 0 0 0 0 0 0 0 . _ 4A5.2om_ .- 0.770 sw ._ _21.56-__ 19.31 0 __ 0 _ 0 0 19 19 _ 407 365 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 1OA-f 0.700 nw 19.60 28.93 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 ,A-rlom 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1B-rlfm- 1.130 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 B-r1 fm - .. _. 1.130 nw 31.64_ 41.61 _ 0 _ 0 0 0 _ - 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 112 112 178 153 316 316 501 432 - - -�C ._._ 17B-6al___ .._-- _ ....0.105 - . _ 2.94. 4.30 .. .-__0 .. 0 _ ---._0. . _ 0 .-- -_0,_. .0 0 0 F._ 22A-tol _ 0.989 27.69 0.00 112- _ 7 194_ _0 316 31 _ 858 0 61 c)AED excursion 1 -51 -118 Envelope loss/gain 1139 876 5495 3343 12 a) Infiltration 142 41 628 180 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 500 0 Subtotal(lines 6 to 13) 1281 1417 6124 3983 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1281 1417 6124 3983 15 Duct loads 0% 0% 0 0 0% 0% 0 0 e room l I I I 12I 141I I I 6I 3I Air requiredTotal (cfm) 54 6 257 172 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.-rid- wr�gfitsofC' 2021-Jun-0914:01:37 RightSuite®Universal 2019 19.0.21 RSU08101 Page t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW wrightsoft° Right-JO Worksheet Job: Main Area Date: Quick Calcs, Inc. By. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Kitchen Dining 2 Exposed wall 0 it 17.0 It 3 Room height 10.5 ft heat/cool 12.7 ft heat/cool 4 Room dimensions 1.0 x 263.0 it 1.0 x 407.0 ft 5 Room area 263.0 ft' 407.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhrft'° I (Btuh/ft') or perimeter (ft) I (Btuh) or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S j Heat Cool 6 13A-flocs 0.143 ne 4.06 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 11 1 B-rlfm __. 1.130 ne 0.00 0.00 .. 0 0 0 0 0 0 0 _ 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 179 53 213 116 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 17 17 369 330 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 18 18 392 351 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om _ 0.770 se 21.56._ 19.31 0 _ 0 0 _ _ 0 90 90 1940 _ 1738 VtJ 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I-C 4A5-2om 0.770 s _ 21.56, 19.31 - 0 _ 0 . 0 0 0 _ 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om _ _ _ 0.770 sw _ 21.56 _ _19.31 0 _ 0 0 __0 0 0_ 0 0 13A-flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 10A-f 0.700 nw 19.60 28.93 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlam 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 B-rl fm. 1.130 nw 31.64 41.61 - 0 0 0 0 0 0 _ 0 0 C 16X19-Omd 0.408 1.59 _ 1.37 263 263 417 360 16 16 25 22 C 17Ma1 0.105 2.94 _ 4.30 0 _-0_ 0 0 500_ 500 - 1470 ,.- _2153 F 22A-tol 0.989 27.69 0.00 263 0 0 0 407 17 471 0 6 c)AED excursion 1 1 -97 -182 Envelope loss/gain 417 262 4881 4529 12 a) Infiltration 0 0 345 99 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 2000 0 Subtotal(lines 6 to 13) 417 2722 5226 5087 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 417 2722 5226 5087 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 171Air required(cfm) 41722 8 2117I I I 5226 219 52189I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr�gf�tsoR-`^- w RightSuiterelUniver�12019 19.0.21 R 2021-Jun-0914:01:37SU08101 Page t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW - wrightsoft Right-JO Worksheet Job: Main Area Date: Quick Calcs, Inc. By: 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcaics@aol.com 1 Room name Foyer Pantry 2 Exposed wall 8.0 ft 0 ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 1.0 x 156.0 ft 1.0 x 82.0 ft 5 Room area 156.0 ft' 82.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (" Load number (Btuh/ft'° I (Btuh/ft2 I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross I N/P/S j Heat I Cool j Gross I N/P/S j Heat Cool 6 W 13A-4ocs 6.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 11 1 B-r1 fm _ 1.130 ne 0.00. . 0.00 . _ .0 0 0 _- 0 _0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1 A-rl om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om - 0.770 se 21.56_ _ -19.31- _ 0 _ 0 0 0 _. 0 0 _ 0 0 Uf/ 13A-40 cs 0.143 s 4.06 2.19 0 0 0 0 0 0 0 0 G 4A5-20m 0.770 s 21.56_. 19.31 0 _ 0-- 0 0 0 0__ _ -0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm 1.130 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-tom 0.770 _sw 21.56 19.31 0 0 0 0 __._. 0 0 0 0 13A-46cs 0.143 nw 4.00 2.19 84 44 176 96 0 0 0 0 10A-f 0.700 nw 19.60 28.93 24 0 470 694 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm., 1.130 nw 31.64 41.61 16 _ 0 506 666 _ 0 0 - 0 0 C 16X19-Omd 0.408 1.59 1.37 156 156 247 213 82 82 130 112 C 176sa1 0 0 0 - _ 0 0 _ o _ 0 0.105_ - 2.94_ 4.30 0 F _ - 22A-tol 0.989 27.69 _ 0.00 156 8 222 0 82 0 _ 0 0 61 c)AED excursion 1 1 4821 1 1 14 Envelope loss/gain 1 1622 2151 1 1 130 108 12 a) Infiltration 162 47 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1784 2198 130 108 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1784 2198 130 108 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load Air required(cfm) I 1775 21995I I 135I 105I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigtiemaft- 2021-Jun-0914:01:37 RightSuite®Universal 201919.0.21 RSU08101 Page t HVAC\Melville Residence-revised 202O code.rup Calc=MJS Front Door faces:SW i - -wrightsoft Right-JO Worksheet Job: Main Area Date. Quick Calcs, Inc. By- 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772466-6799 Email:quickcalcs@aol.com 1 Room name Closet Great Room 2 Exposed wall 0 ft 18.0 ft 3 Room height 10.5 ft heat/cool 12.8 ft heaUcool 4 Room dimensions 1.0 x 64.0 ft 18.0 x 23.0 ft 5 Room area 64.0 ft' 414.0 ft' Ty Construction U-value Or I HTM I Area (ft) Load I Area (ft2) Load number (Btuh/ft'-° (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 ne 4.00 2.19 0 0 6 0 0 0 0 0 IA-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 IA-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 IA-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 11 1B-rtfm 1.130 ne- 0.00 _ 0.00 0 _ 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 189 82 328 179 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 10A-m 1.670 se 46.76 25.31 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 ,A-rlom 1.270 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 17 17 369 330 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 21.56 19.31 0 0 0 0 0 0 0 0 .4A5-2om _.__ 0.770 _se 21.56-_ 19.31 _ 0 0 _0 0 90 90 ._. 1940 ._ _.1738 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 4A5-2om--____ 0.770 s 21.56- 19.31 0 0 _ 0 0 0 - 0 0 _ __ - 0 13A4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 lA-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 lA-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 0.00 0.00 0 0 0 0 0 0 0 0 7-=G 4A5-2om ._._ _ _ __0.'770 sw 21.516 _ 19.31 0.„ _0 _ 0 0 0 0 _ 0 _ _ _ 0 13A-4ocs 0.143 nw, 4.00 2.19 6 0 0 0 6 0 0 0 1OA-f 0.700 nw 19.60 28.93 0 0 0 0 0 0 0 0 lA-rlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 lA-rlom 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 B-rl fm_ _ 1.130 nw, 31.64 _ 41.61 0 _ 0 0 0 0 _0 0 0 C 16X19-Omd 0.408 1.59 1.37 64 64 101 88 0 0 0 0 0.1 17Br6al_ - -__ 05 - 2.94. 4.30 _.. 0 __ __ 0 0 _, 0 525 525-_ _ 1544 2261 F _ _ 22A-tpl - 0.989 _- 27.69 _ 0.00 64 --0-. 0_ _ 0 _ _ 414 18 _ 498 0 61 c)AED excursion 1 -3 -201 Envelope loss/gain lot 85 4680 4307 12 a) Infiltration 0 0 365 105 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal(lines 6 to 13) 101 85 5044 5612 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 101 85 5044 5612 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load I I I 1011 85 I I 50441 56121 Air required(cfm) 4 4 212 242 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -4- wrAgtificpfe- 2021-Jun-0914:01:37 '•^^--'•�-� RightSuite@ Universal 2019 19.0.21 RSU08101 Page sue• t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW wrightsoft• Right-JO Worksheet Job: Unit#2 Date: Quick Calcs, Inc. By. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Unit#2 Master Bedroom 2 Exposed wall 190.8 ft 42.8 ft 3 Room height 10.5 ft 10.5 ft heat1cool 4 Room dimensions 1.0 x 379.0 ft 5 Room area 2020.0 ft' 379.0 ft' Ty Construction U-value Or HTM Area ') Load Area (ft2) Load number (Btuh/ft'. I (Btuh/ft2 I or perim(fteter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _ 13A-4acs 0.143 ne 4.06 2.19 410 405 1621 886 200 200 799 436 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1,270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1B-r1fm _1.130 ne 31.64 41.61 -_ 5 _- 0 150 198 0 0 _ 0 _ 0 13A-4ocs 0.143 se 4.00 2.19 313 222 888 485 187 121 484 265 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 25 14 896 846 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 19 11 672 635 19 11 672 635 1A-r1om 1.270 se 35.56 33.58 19 11 691 652 19 11 691 652 1A-r1om 1.270 se 35.56 26.39 27 27 971 720 27 27 971 720 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om_- 0.770- se 0.00 0.00 - 10 - 0-_ __ 0 0 0 0 - 0 0 V)! 13A-4ocs 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om .._ __ 0.770 _-s. 0.00 0.00_ _ 0 - 0 _0- _ _ _ 0 ___0 0_-__ _ 0 0- 13A-4ocs 0.143 sw 4.00 2.19 840 702 2810 1536 63 44 174 95 ,A-rlom 1.270 sw 35.56 26.39 12 12 427 317 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 30 22 1067 932 0 0 0 0 IA-rlom 1.270 sw 35.56 31.07 23 16 800 699 0 0 0 0 1A-r1om 1.270 sw 35.56 31.76 11 7 377 337 0 0 0 0 1A-rlom 1.270 sw 35.56 33.58 58 33 2072 1957 19 11 691 652 1B-r1fm 1.130 sw 31.64 24.50 5 5 150 116 0 0 0 0 4A5-2om - 0.770 sw _ 0,00 0.00 0 0 _ 0 0 _„ 0 0 0 _ 0 13A-4ocs 0.143 nw 4.00 2.19 441 414 1658 906 0 0 0 0 1OA-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 15 0 533 645 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm 1.130 nw 31.64 41.61 12 0 380 499 0 0 0 0 1B-rlfm ._ 1.130 nw 0.00 0.00 0 _ 0. 1 0 0 - 0 0 _ 0 0 C 16X19-Omd 0.408 7 1.59 1.37 2020 2020 3203 2764 379 379 601 519 C_ 17B-6al 0.105__-- _ 0.00 0.00 0- _ 0 0 0 _ -.0 _ _ 0- _ 0 0 F _ _ 22A-tol .. 0.989 27.69 0.00 2020 191 5282 0 379 43 1184 0 61 c)AED excursion 1 1 19481 1 1 144 Envelope loss/gain 1 24648 17078 1 1 6267 3931 12 a) Infiltration 3866 111C 867 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 12 2760 2 460 Appliances/other 1800 900 Subtotal(lines 6 to 13) 285141 227481 7134 5540 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28514 22748 7134 5540 15 Duct loads 16% 13% 4450 3030 16% 13% 1113 738 Air requomdl(�) I I 312 0 21200I I 8300I 6292I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -I*- wrigtit coft- 2021-Jun-0914:01:37 Right•Suite@ Universal 2019 19.0.21 RSU08101 Page t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW -wrightsoft• Right-JO Worksheet Job: Unit#2 Date: Quick Calcs, Inc. By: 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772466-6799 Email:quickcalcs@aol.com 1 Room name Exercise WIC 2 2 Exposed wall 27.0 ft 7.0 ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 1.0 x 121.0 ft 8.0 x 8.0 ft 5 Room area 121.0 ft' 64.0 ft' T Construction U-value Or HTM Area ft Load Area ft Load y number (Btuh/k2° I (Btuh/ft') I or pedmeer (ft) I (Btuh) I or perimet r (ft) I (Btuh) Heat I Cool Gross WP/S Heat Cool Gross N/P/S Heat cool::] 6 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1B-rlfm 1.130 ne 31.64. 41.61 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 95 69 277 152 0 0 0 0 1OA-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 25 14 896 846 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 ,A-rlom 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om - _ 0.770 se 0.00 _ 0.00 _ - 0. 0- 0. 0 0 0 _ _ 0 __ 0 13A-4ocs 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 t-G. 4A5-2om 0.770 _s _ 0.00 0.00 0 0 0 0 _ 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 147 108 433 237 74 63 252 138 1A-r1om 1.270 sw 35.56 26.39 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.76 0 0 0 0 11 7 377 337 1A-r1om 1.270 sw 35.56 33.58 39 22 1382 1305 0 0 0 0 1 B-rl fm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 4A5-tom ,0.770 sw 0.00 _ 0.00 0 0 0 0 0 0 0 _ . 0 13A-flocs 0.143 nw 4.00 2.19 42 42 166 92 0 0 0 0 1OA-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 1 B-r1fm 1.130--nw 0.00 _ 0.00 0 0 0 0 0 0 0 0 C _ 16X19-Omd _ 0.408 _ 1.59 1.37 121 1.21 192 16.6 _ 64 6.4 101 88 C _ 17B,6a1 _ _ _ 0.105 0.00 . 0.00 0 0 0 . _ 0 0 0_ 0. 0 F_ _ 22A-tpl _ 0.989 27.69 _ 0.00 - 121_ 27 748 0 64 7 194 0 61 c)AED excursion 1 3251 1 1 1 164 Envelope loss/gain 4096 3122 1 1 924 726 12 a) Infiltration 547 157 142 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 900 0 Subtotal(lines 6 to 13) 4643 4639 1066 996 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4643 4639 1066 996 15 Duct loads 16% 13% 725 618 16% 13% 166 133 Total room dl( d I I 536111 52,571 I 125I 1153Iirrqi load 195 245 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -a-d- wrigtilsoft- 2021-Jun-0914:01:37 �+ �•�^�-•�-- RightSuite®Universal 2019 19.0.21 RSU08101 Page t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW wrightsoft• Right-J® Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Master Bath Toilet 2 Exposed wall 18.0 ft 0 ft 3 Room height 10.5 ft heaticool 10.5 ft heaUcool 4 Room dimensions 1.0 x 203.0 ft 4.0 x 6.0 ft 5 Room area 203.0 ft' 24.0 ft' T Construction U-value Or HTM Area it ft Load Area Load y number (Btuhfft'° I (Btuhfft� I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 o 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1B-rlfm_ __ 1.130 ne 31.64 41.61 0 0 _._0 0 0 0 0 _0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 1OA-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1OA-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om _ _ 0.770 se 0.00_ 0.00 0 -0 0 0 0 _ 0- _ 0 0 13A-4ocs 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 t-G. 4A52om _____ ---0.770 .s 0.00_ _ 0.00 0 0 _ 0 0 0- 0 _ 0 ___ _ 0 13A4ocs 0.143 sw 4.00 2.19 116 95 378 207 0 0 0 0 1A-r1om 1.270 sw 35.56 26.39 6 6 213 158 0 0 0 0 IA-rlom 1.270 sw 35.56 31.07 15 11 533 466 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 4A5-2om . 0.770 sw. 0.00 0.00 0 0 0 0 _. _ 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 74 74 294 161 0 0 0 0 1OA-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-rlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 1B•rlfm- 1.130 _nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 2.03 203 3.22 27.8 24 24 38 33 178-6a1 -_ .._ _ 0.105 0.00 . 0.00 0 0 0 0 0 0 0 0 F. 22A-tol 0.989 - 27.69 0.00 _ 203 _ 18 - 498 0 24 0 0 0 61 c)AED excursion 1 1 3611 1 10 Envelope loss/gain 1 2240 1631 1 1 38 33 12 a) Infiltration 365 105 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2605 1735 38 33 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2605 1735 38 33 15 Duct loads 16% 13% 406 231 16% 13% 6 4 Total room load I I I 30111 1967 I I 441 371 Air required(cfm) 110 92 2 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgf�tsaFt- 2021-Jun-0914:01:37 s•« RightSuite@ Universal 2019 19.0.21 RSU08101 Page ..t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW i - wrightsoft Right-JO Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Bedroom 4 WIC 1 2 Exposed wall 15.0 ft 0 ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 1.0 x 216.0 ft 10.0 x 8.0 ft 5 Room area 216.0 f? 80.0 f? T Construction U-value Or HTM Area ft2 Area Load ft Load y number (Btuh/ft'-° I (Btuhlft� I or perimeter (ft) I (Btuh) I or perimet r (ft) I (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1B-r1fm .__. 1.130 ne 31.64 _ 41.61 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 11 11 42 23 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1OA-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om _ 0.770 se 0.00 0.00 0 _ 0 0 0 _ 0 _ 0 0 0 V(J 13A4ocs 0,143 s 0.00 0.00 0 0 0 0 0 0 0 0 I_G 4A5-2om 0.770 s 0.00 0.00 0 _ 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 137 122 486 266 0 0 0 0 1A-r1om 1.270 sw 35.56 26.39 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 15 11 533 466 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-r1fm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.06 2.19 11 11 42 23 0 0 0 0 10A-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 216 216 342 296 80 80 127 109 _C._-. 17B-6al.-------.. _ 0.11)5 .0.00 . -_0.00 __0 - 0 _ - -0 0 - F__ 22A-tol _ 0.989 - 27.69 _0.00 216 __ 15 _ 415 0 . _ 80 0 - 0 0 61 c)AED excursion 1 1 231 -3 Envelope loss/gain 1 1862 1304 1 1 127 107 12 a) Infiltration 304 87 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 2166 1852 127 337 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 25 22 0 0 14 Subtotal 2191 1873 127 337 15 Duct loads 16% 13% 342 250 16% 13% 20 45 Air requi dI room load(cfm) I 2592 331 2199I I I 145I 382181 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlghtaaft- 2021-Jun-0914:01:37 �" ^•°!!5tn IZghtSuite®Universaal2019 19.021 RSU06101 Page10 t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW -##wrightsott" Right-JO Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Bath 4 Bedroom 3 2 Exposed wall 6.0 ft 18.0 ft 3 Room height 10.5 ft heat1cool 10.5 it heat/cool 4 Room dimensions 11.0 x 6.0 ft 1.0 x 248.0 ft 5 Room area 66.0 ft' 248.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft� Load number (Btuhfft;° (Btuh/ft') or perimeter (ft) I (Btu h) or perimeter (ft) I (Btuh) Heat Cool Gross I N/P/S j Heat I Cool j Gross I WP/S j Heat Cool 6 V 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlam 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1B-rlfin 1.130 ne 31.64 41.61 0 0 0 0 0 0 _ 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 21 21 84 46 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 IA-rlam 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 Ij4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om_ 0.770_ se 0.00_._ 0.00_ 0 0 --0- 0 0 0 _ _0 _ _ _ 0 13A-4ocs 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 _4A5-2om _ 0.770 s 0.00 _0.00 0 0 ___ 0_ 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 63 57 228 125 168 146 583 318 ,A-rlom 1.270 sw 35.56 26.39 6 6 213 158 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 23 16 800 699 1A-r1om 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 1A-r1am 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-r1fm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 _- _ 4A5-2om _. _ . _ 0.770.. sw 0.00 _ -_0.00 0 0 0 0 ._ 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 10A-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1am 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 1B-r1fm 1.130 _nw 0.00 0.00 0 0 _. 0 0 0 0 0 0 C 16X19-0_md_ _ _ _ 0.408 1.59 _ 1.37 66 66 105 90 248 248 _ 393 339 C_ _ 17B-6a1 _..._ 0.105 0.00 0.00 . 0 0. 0 _ 0_ _. 0 0 0 0_ F 22A-tol_ 0.989 27.69 0.00 66 6 186 0 248 18 498 0 61 c)AED excursion 1 1231 1 1 1 352 Envelope loss/gain 712 496 2358 1755 12 a) Infiltration 122 35 365 105 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 834 761 2723 2089 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 22 19 15 12 14 Subtotal 856 780 2738 2102 15 Duct loads 16% 13% 134 104 16% 13% 427 280 1 1 Air Totequi d(�) 1 1 room load 9361 84411 1 1 31151 2382 1111 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri0lt2x4:.74t- 2021-Jun-09 14:01:37 a^ ^a Pig htSuite®Universal 201919.0.21 RSLI08101 Page11 t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW -Ptll�wrightsoft Right-JO Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Bath 3 Bath 2 Exposed wall 14.0 ft 10.0 ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 7.0 x 7.0 ft 10.0 x 7.0 ft 5 Room area 49.0 fY 70.0 ft' Ty Construction U-value Or I HTM I Area (M) I Load I Area (ft�) I Load number (Btuh ft'" (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool I Gross N/PIS j Heat I Cool j Gross I N/P/S j Heat Cool 6 13A-flocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1 B-rlfm ,...-----__.__ ._ _ '1.130 ,ne 31.64__.._.41.61 - -0 . - 0. 0 0 _.- 0 _ .0_- 0 0- 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 J�! 4A5-20 m 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20m 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om_. .-- 0.770..se _ .0.00._-_0.00 _ 0. _ .._ 0 -0 -0 -0- - "0 _. 0__ ., ..._ 0 13A-4ocs 0.143 s 0.00 0.00 0, 0 0 0 0 0 0 0 4A5-2om__--._- __ _ . 0,7.70 -s_ ._._0.00 ._ 0.00 _- .. __.0 ._ _ __ 0.-_ 0--- --- ---0-_._ '___0 - _ _ 0- 13A-4ocs 0.143 sw 4.00 2.19 74 69 275 150 0 0 0 0 1A-rlom 1.270 sw 35.56 26.39 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 31.64 24.50 5 5 150 116 0 0 0 0 4A5-2om .- _-- 0.770 sw _ - -0.00 0.00- _ -_-0- -. . -0 ___---.0. _ 0- :_.. _-0_ _0 _ - 0 -0 13A-4ocs 0.143 nw 4.00 2.19 74 74 294 161 105 93 372 203 1OA-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1Ar1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm 1.130 nw 31.64 41.61 0 0 0 0 12 0 380 499 1B,r1fm _ .1.130 _nw 0.00 0.00 0 ._ 0 0 _ 0 0 0 _0 - _._ _0 C 16X19-Omd 0.408 1.59 1.37 _ 49 49 ---_78_ 67 70 70 111 96 C,.--- -17B-6al_-_--_._- 0-.105- - _0.00 0.00 0_ -- -___0-_. .. _...0 _ -- _0 .__ 0 _ _0 .._ 0,--"- _0 F_.__ 22A-tol .,_...- _0.989_- 27.69 0.00 _ 49_ __-_14 _ 388 _ - _ 0 _. 70 - .__ 10 277 _ 0 61 c)AED excursion 1 861 1 1 1 172 Envelope loss/gain 1185 581 1 1 1140 970 12 a) Infiltration 284 81 203 58 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1469 662 1343 1028 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1469 662 1343 1028 15 Duct loads 16% 13% 229 88 16% 13% 210 137 Total room load I 16981 751 I I 15521 11651 Air required(cfm) 62 35 57 54 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i4d- =!:!q ts4.-.�.-. 2021-Jun-0914:01:37 .•m-... Right-Suite®Universal RSU08101 Page 12 t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW wirightsoft Right-J® Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Bath 2 Closet 4 2 Exposed wall 14.0 ft 0 ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 7.0 x 7.0 ft 5.0 x 6.0 ft 5 Room area 49.0 ft' 30.0 ft' T Construction U-value Or HTM Area ft2) Load Area ft Load y number (Btuh/ft'-° I (Btuhlft� I or perimeter (ft) I (Btu I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.19 74 69 275 150 0 0 0 0 IA-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1B:r1fm_ ____ 1.130 ne 31.64 41.61 .5 _ _ 0 150 198 _ 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om ___._ - _0.770 se 0.00_ 0.00 _ -._e, 0 0 0 - 0 0 _0 _ _ 0 -0 t! 13A-4ocs 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 G.AA&2om __ _ 0.77,0 s 0.00. __._0.00 _ -_.,_.. 0 .. _..._._0 0 _- _ 0._ -0_ _- .0 M _ 0 _.__0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1 om 1.270 sw 35.56 26.39 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 0.00 0.00 0 _ 0 0 0 0 0 0 0 13A-4ors 0.143 nw 4.00 2.19 74 74 294 161 0 0 0 0 10A-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 ,A-rlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-r1fm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 1 B:r1 fm__..__ 1.130 nw 0.00 0.00 0 _ 0 _0 _ 0 0 _ 0 0 -.0 C 16X19-0md 0.408 1.59 1.37 49 49 78 67 30 30 48 41 _C _ _ 176-6al-_ 0.105 _ 0.00 0.00 0 0_ _ 0 0 _ ,_ 0 0 _0 - 0- F _ 22A-tol ___ __. 0.989 27.69 _ 0.00 .49 _ 14 388 -0__,_. _ 30 µ 0 v. 0 0 61 c)AED excursion 1 1 -51 1 1 1 0 Envelope loss/gain 1 1185 571 1 1 48 41 12 a) Infiltration 284 81 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1469 652 48 41 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 18 15 14 Subtotal 1469 652 65 56 15 Duct loads 16% 13% 229 87 16% 13% 10 7 Total Air required eQUi d(�) I I I load 1662I 73983 4 I 73I 63I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f'* wr�gfittMo7`!- 2021-Jun-0914:01:37 RghtSuite@ Universal 201919.0.21RSU08101 Page 13 t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW +wrightsoft Right-JO Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Linen AHU 2 Exposed wall O ft O ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 4.0 x 4.0 It 4.0 x 4.0 ft 5 Room area 16.0 ft' 16.0 fN Ty Construction U-value Or I HTM I Area (M I Load I Area (ft') I Load number (Btuh/ft;° (BtuhHt� or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 1B-rlfm_ _-._ _- __ 1.130 ne 31.64 41.61 0 _. 0 _ 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 1OA-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 ,A-rlom 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20 m 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om _. 0.770 se 0.00 0.00 0 _ 0 0 0 0 0 _0 0 Vt! 13A-4ocs - 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 Ili 4A5-2om_ _ 0.770 s _ _O.OQ _ 0.00 _ 0 0 0 0 0 0 0 -0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 26.39 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-r1fm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 4A5-tom 0.770 sw 0.00 0.00 0 0 0_ 0 _ 0 0 0 0 13A-4ocs 6.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 1OA-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 1B-rlfm 1.130 my 0.00_ 0.00 0, 0 _ 0 0- 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 16 16 25 22 16 16 25 22 _C 176-6a1 -_. _ _ 0.105 0.00_ _ 0.00 0 0 0 _ 0 0 0 _ _ 0 0 F 22A-tpl____ _ 0.989 27.69 0.00 16 0 -0 0 16 0 0 0 6 c)AED excursion 1 01 1 10 Envelope loss/gain 1 25 22 1 1 25 22 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 25 22 25 22 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -25 -22 -25 -22 14 Subtotal 0 0 0 0 15 Duct loads 16% 13% 0 0 16% 13% 0 0 AirtaeQUoedload ( ) I I 0I OI I 0I OI Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. a#t- wrlgt,tspftt- 2021-Jun-0914:01:37 �+ F RightSuite@ Universal 201919.0.21 RSU08101 Page14 t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW wrightsoft Right-JO Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Hall 3 Powder 2 Exposed wall O ft O ft 3 Room height 10.5 ft heat/cool 10.5 ft heat/cool 4 Room dimensions 1.0 x 39.0 ft 1.0 x 68.0 ft 5 Room area 39.0 ft' 68.0 ft' Ty Construction U-value Or I HTM I Area (ft) I Load I Area 01:1 I Load number (Btuhfft'° (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-flocs. 0.143 ne 4.00 2.19 0 0 7 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00- 0 0 0 0 0 0 0 0 iB-rlfm_ 1,130 -ne_ 31.64- 41.61, ._ -0- _ -0 0 -0 .;;_ _ -.0 0 _.. 0 __.__.; _0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 1A-r1om 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om_._,- .-- _ ,0.770_ se_ _. 0.00. .. 0.00 -__0_ - - 0 --0 -.0 13A-4ocs 0.143 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om__. -0.770__s _ 0.00, 0.00 _ 0 .--_- 0 -0 --- . _0- _----- 0 - --0' _ 0 _ 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 26.39 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 1A-rlom 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 4A5tom_ _ 0.770 _sw_ 0.00 - __0_00 0 0 -0 __-_ 0 0 _ 0 ,_ 0 ____0 _ - - - - -- _ 13A-40 cs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 10A-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om` 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1B-rlfm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 1 B-r1 fm_--.. _ -- 1.130 nw 0.00_ _0.00 0 _ 0 0 _ 0 0 _ 0 _._.___-0 0 C _ 16X19-Omd _ 0.408 1.59 1.37 _ _39 39 62 53 68 68 108 - 93 0.105 _- 0.00 ,.__0.00 __.._ �_0 _ _ 0 - 0-_ _0___.. _0 -_ 0- 0 _.0 22A-tpl 0.989._= _ 27.69 0.00- __39- 0 - 0 0 _. _._ -'68 - -0 0 61 c)AED excursion 01 13 Envelope loss/gain 62 53 1 1 108 91 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 62 53 108 321 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -62 -53 49 42 14 Subtotal 0 0 156 362 15 Duct loads 16% 13% 0 0 16% 13% 24 48 Air al requomdl(�fm) I 0I 0I I 187I 410 19I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr�g�ltsoR 2021-Jun-0914:01:37 .►Y �^�+ RightSuite®Universal 2019 19.0.21 RSU08101 Page 15 t HVAC\Melville Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW wrightsoftt Right-JO Worksheet Job: Unit#2 Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com 1 Room name Hall 2 Bedroom 2 2 Exposed wall 0 ft 19.0 ft 3 Room height 10.5 ft heat1cool 10.5 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 1.0 x 232.0 ft 5 Room area 50.0 ft' 232.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuhfftz° (Btuh/ft2) or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2,19 0 6' 0 0 137 137 547 299 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1,270 ne 0.00, 0.00 0 0 0 0 0 0 0 0 11 .- .1B-rlfm___ .... 1.130 'ne 31.64 41.61 0 -_... 0- 0. ___o .; 0 0 0 _-0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1OA-m 1.670 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 35.56 33.58 0 0 0 0 0 0 0 0 IA-rlom 1.270 se 35.56 26.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 se 0.00 0.00 0 0 0 0 0 0 0 0 _ 4A572om. _._-- _ ._ _ .__ .0.770 _se 0.00 ,_ 0.00 _. 0 _0_ _ ._ _ 0 0 _.- .. __ 0 0'', VV��JJ 13A-4ocs 0,143 s 0.00 0.00 0 0 0 0 0 0 0 0 � G- 4A52om___-- 0.770 s 0.00 _ 0.00 --- __- 0 _ _ 0 ._. 0.-- -- __0 _. .. ._. 0 0 _ --. _0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-rlom 1.270 sw 35.56 26.39 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 35.56 31.07 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 35.56 31.76 0 0 0 0 0 0 0 0 IA-rlom 1.270 sw 35.56 33.58 0 0 0 0 0 0 0 0 1B-rlfm 1.130 sw 31.64 24.50 0 0 0 0 0 0 0 0 4A5-tom _ 0.770 sw. 0.00 0.00 0 0 _ _ 0 0 _- 0 0 0 _ _ 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 63 48 192 105 1OA-f 0.700 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 15 0 533 645 ,A-rlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 lB-rlfm 1.130 nw 31.64 41.61 0 0 0 0 0 0 0 0 _- 1.B-rlfm-_ 1.130 nw 0.00 0.00 _. 0" ._ 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 50 50 79 68 232 232 368 317 C---- 176-6aI.__. 0.105 0.00 0.00 0--- - - 0 ------ 0 0--.1 _ .0- - 0 - 0 22A-tol -- - --0.989 27.69 0.00 50 - --0 0. 0 -- 232_ _232 _._19 _. 526 0 61 c)AED excursion 1 190 Envelope loss/gain 79 68 2166 11 12 a) Infiltration 0 0 385 111 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 79 68 2551 1897 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -79 -68 64 55 14 Subtotal 0 0 2615 1952 15 Duct loads 16% 13% 0 0 16% 13% 408 260 Air requomdl(�) I I OI 0 01 I I 31110 21 3I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -+FW wrigfttsoft- 2021-Jun-0914:01:37 RightSuite@Universa1201919.0.21RSU08101 Page16 t HVACNMelvil[e Residence-revised 202O code.rup Calc=MJ8 Front Door faces:SW wrigh#soft Duct System Summary Dab Main Area By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com Project • • For: Melville Residence 7827 Sabal Lake Drive, Port St. Lucie, FL 34950 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.279 in/100ft 0.279 in/100ft Actual air flow 1200 cfm 1200 cfm Total effective length(TEL) 179 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk Cabana Bath h 1121 47 22 0.291 5.0 Ox 0 VIFx 36.7 135.0 st7 Closet h 101 4 4 0.381 4.0 Ox 0 VIFx 16.1 115.0 st3 Den h 6124 257 172 0.345 9.0 Ox 0 VIFx 29.9 115.0 st1 Dining-A c 2613 110 110 0.361 8.0 Ox 0 VIFx 23.6 115.0 st2 Dining-B C 2613 110 110 0.361 8.0 Ox 0 VIFx 23.6 115.0 st2 Foyer C 2198 75 95 0.354 7.0 Ox 0 VIFx 26.2 115.0 st3 Great Room-A C 2806 106 121 0.283 7.0 Ox 0 VIFx 41.9 135.0 st9 Great Room-B C 2806 106 121 0.279 7.0 Ox 0 VIFx 44.3 135.0 st9 Hall 1 h 1907 80 35 0.287 5.0 Ox 0 VIFx 39.5 135.0 st7 Kitchen c 2722 18 117 0.348 8.0 Ox 0 VIFx 28.8 115.0 st2 Laundry c 1417 54 61 0.292 6.0 Ox 0 VIFx 36.0 135.0 st7 Office h 2725 114 114 0.372 6.0 Ox 0 VIFx 19.3 115.0 st3 office-A h 2725 114 114 0.368 6.0 Ox 0 VIFx 20.9 115.0 st3 Pantry h 130 5 5 0.386 4.0 Ox 0 VIFx 14.5 115.0 st3 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st9 Peak AVF 212 242 0.279 548 9.0 0 x 0 VinlFlx st2 st3 Peak AVF 313 331 0.354 422 12.0 0 x 0 VinlFlx st2 Peak AVF 449 579 0.279 541 14.0 0 x 0 VinlFlx st1 Peak AVF 438 290 0.287 558 12.0 0 x 0 VinlFlx st7 Peak AVF 181 118 0.287 518 8.0 0 x 0 VinlFlx st1 . wrightsoft- 2021-Jun-0914:01:39 .�., Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 1 + ...t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 1200 1200 0 0 0 0 Ox 0 VIFx - - wrightsoft^ 2021-Jun-0914:01:39 .a.+ RightSuite®Universal 201919.0.21 RSU08101 Paget ...t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW wrightsoft Duct System Summary JoDate: Unit#2 By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772466-6799 Email:quickcalcs@aol.com Project • • For: Melville Residence 7827 Sabal Lake Drive, Port St. Lucie, FL 34950 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 In H2O 0.50 In H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.276 in/100ft 0.276 in/100ft Actual air flow 1200 cfm 1200 cfm Total effective length(TEL) 181 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk Bath h 1552 57 54 0.299 5.0 Ox 0 VIFx 32.0 135.0 st11 Bath 2 h 1698 62 34 0.294 5.0 Ox 0 VIFx 35.1 135.0 st11 Bath 3 h 1698 62 35 0.290 5.0 Ox 0 VIFx 37.5 135.0 st11 Bath 4 c 884 36 41 0.366 4.0 Ox 0 VIFx 21.7 115.0 st6 Bedroom 2 h 3023 110 103 0.369 6.0 Ox 0 VIFx 20.3 115.0 st6 Bedroom 3 h 3165 115 111 0.370 6.0 Ox 0 VIFx 20.0 115.0 st6 Bedroom 4 c 2123 92 99 0.383 6.0 Ox 0 VIFx 15.4 115.0 st5 Closet 4 c 63 3 3 0.382 4.0 Ox 0 VIFx 15.8 115.0 st5 Exercise c 5257 195 245 0.276 9.0 Ox 0 VIFx 46.4 135.0 st10 Master Bath h 3011 110 92 0.344 6.0 Ox 0 VIFx 30.4 115.0 st4 Master Bedroom h 4123 150 146 0.283 7.0 Ox 0 VIFx 41.9 135.0 st10 Master Bedroom-A h 4123 150 146 0.277 7.0 Ox 0 VIFx 45.5 135.0 st10 Powder c 410 7 19 0.361 4.0 Ox 0 VIFx 23.5 115.0 st5 Toilet c 37 2 2 0.333 4.0 Ox 0 VIFx 35.1 115.0 st4 WC 1 c 382 5 18 0.341 4.0 Ox 0 VIFx 31.8 115.0 st4 WIC 2 c 1129 45 53 0.335 5.0 Ox 0 VIFx 34.2 115.0 st4 -014- wrightsmft" 2021-Jun-0914:01:39 �-Q-. -, «. _. RightSuite®Universal 201919.0.21RSU08101 Page ACCA ...t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 102 121 0.361 452 7.0 0 x 0 VinlFlx st11 Peak AVF 180 124 0.290 516 8.0 0 x 0 VinlFlx st6 st6 Peak AVF 441 379 0.290 562 12.0 0 x 0 VinlFix st4 Peak AVF 657 701 0.276 655 14.0 0 x 0 VinlFlx st10 Peak AVF 496 537 0.276 684 12.0 0 x 0 VinlFlx st4 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 1200 1200 0 0 0 0 Ox 0 VIFx -�- wrightsoft- 2021-Jun-0914:01:39 RightSuite®Universal 2019 19.021 RSU08101 Page4 C+� ...t HVAC\Melville Residence-revised 2020 code.rup Calc=MJ8 Front Door faces:SW