Workorder No: 240088-1
Report Date: 07/20/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
Client
Project
In -Place Density Test Report
Doyle Masonry, Inc.
P.O. Box 12339
Fort Pierce, FL 34979-2339
Port St Lucie CSD/CMT
Various Location, TBD County, FL
Area Tested: 4811 Treetop Trail, Ft. Pierce - Room
Addition Footings
Material: Backfill
Reference Datum: 0 = Top of Footing
The tests below meet the 95% minimum compaction requirement.
UES Technician: Mark Rogers
Date Tested: 07/20/2021
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Southside footings
0-1 ft
102.1
13.1
101.1
12.8
99
Pass
2
Eastside footings
0-1 ft
102.1
13.1
100.5
12.9
98
Pass
Remarks: Permit:2102-0558
Reviewed By
GFA International, Inc
FBPE Registry No.4930
,,"" " p
Digitally signed by Paul H
J�N,......
QP.." JceNSF'.. Ty
Danforth:A01410000000177D4E1002100013
* ` `*
AF2
No. aasss =
DN: c=US, o=Universal Engineering Sciences,
--a ". *
cn=Paul H
;0 STATE OF ; ¢�
Danforth:A01410000000177D4E1002100013
AF2
�oNAL``
Date: 2021.07.21 11:19:44-04'00'
Paul H. Danforth
Regional VP
STATE OF FLORIDA
Professional Engineer No. 44653
This item has been digitally signed and sealed by Paul H. Danforth
on the date adjacent to the seal. Printed copies of this document are
not considered signed and sealed and the signature must be
verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1