APPROVED Design Pressure Report - Richard Reiff - Galeforce Hurricane Shutters
Property Information Owner: Richard Reiff Address:5604 Paleo Pines Cir Fort Pierce, FL 34951 Building Information Wind Zone:170 MPH. Exposure Category:B Minimum Building Dimension:5 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 72.5 91 7 28.1 -30.7 2 Int 7 28.1 -30.7 3 Int 33.5 57 7 30.6 -33.2 4 Int 33.5 57 7 30.6 -33.2 5 Int 33.5 45 7 31.1 -33.7 6 Int 33.5 45 7 31.1 -33.7 7 Int 62.75 57 7 29.3 -32.0 8 Int 33.5 45 7 31.1 -33.7 9 Int 72.5 90 7 28.1 -30.7 10 Int 7 28.1 -30.7 11 Int 72.5 90 7 28.1 -30.7 12 Int 62.75 57 7 29.3 -32.0 13 Int 33.5 45 7 31.1 -33.7 14 Int 33.5 45 7 31.1 -33.7 15 Int 33.5 33 7 31.2 -33.8 16 Int 124.5 57 7 27.9 -30.6 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1