HomeMy WebLinkAboutBlower door, dut leakage 7.26.21Duct Leakage Test Report
Prescriptive or Performance Method
Permit #
Job Information
Builder: DRHORTON Community: � Ae r,dw Lot: yj•
Address: i3 c ��', Unit:
City: f ; �-� State: FL Zip: t- �>✓�
Duct Leakage Test Results 0 Presc(ptive Method () Performance Method
System 1
System 2
System 3
Sum of any additionai
systems
i
Total of all systems
Total of all systems
PASS
Testing Company
Total Conditioned
Square Footage
F-i" FAIL
D Prescriptive Method crm25 (total)
To qualify as "substantially leak free" On must be less than or equal to 0.04
if air handler unit is installed. if air handler unit is not installed, On Total
must be less than or equal to 0.03. This testing method meets the
reouirements in accordance with Section R403.2.2
Q Performance Method cfm25 (Out or Total)
To qualify as "substantially leak free" On must not be greater than the
proposed duct leakage On specified on Form R405-2014
Leakage Type selected On specified on Form
on Form R405-2014 R405-2014(Energy Calc)
Company Name: SUN SEAL LLC Phone: 321-412-0035
1 hereby verify that the above dud leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: 1 -�� �3 Zk
Signature of Tester:
Printed Name of Tester: RAULY BAGGETT
License/Certification # 5o66185 Issuing Authorlty BPI
Envelope Leakage Test Report
(Blower Door Test)
R402.4.1.2 Compliance
Permit #
Job Information
Builder: DR HORTON Community: C fep kJ r, Lot: 1,
Address: -1,71j41 Unit:
City: c State: FL Zip' kl^,�-1 j
Air Leakage Test Results Passing results must be 7ACH(SO) or less
L` rz5S Method for calculating building volume:
l
x 60 _ k�17 =
CFM(SO) Building Volume ACH(50) 0 Retrieved from architectural plans
0 Code software calculated
O PASS FAIL Field measured and calculated
i
r-�When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department.
L_ .
Certification of Test Results
R40L4.1.2 Testing. The building or dwelling unit snap oe tested ano venved 6n nav,ng U„ un �—U , a — — „— �---^6 • --
per hour In Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a
pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither Individuals as defined in Section 553.993(5) or (7), FS. or
�c-
individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test
shall be signed by t-he party conducting the test and provided to the code official. Testing shall be performed at any time after creation of
f"
Testing Company
Company Name: SUN SEAL LLC Phone: 321-412-0035
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test:
Signature of Tester:_ 'S�" Y 1 UOil
.1 rN\!
Printed Name of Tester: RAULY BAGGETT
License/Certification # 5066185 Issuing Authority BPI