APPROVED DESIN PRESSURE
�� Y••�. Castle Impact winCfCaWS FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS 1 M2 Dr Nwtin Ludm IGng Blvd Wens ywK FL IMN 800.643.6271 Pro Information E Building Information Owner: JOHNSON.. COILEY Wind Zane: 160 MPH. Address: W.0.406072021020 Exposure Category: C 2606 ARNOLD COURT Minimum Building Dimension: 25 ft. FORT PIERCE, FL 34946 Mean Roof Height: 15 ft. Risk Category: I[ Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) I Int 74 50 7 31.4 -34.3 2 Int 74 52 7 31.3 -34.2 3 Int 53 39 7 32.7 -35.5 4 Int 53 39 7 32.7 -35.5 5 Int 37.5 39 7 33.4 -36.3 6 Int 27 39 7 33.5 -36.3 7 Int 37 39 7 33.5 -36.3 S Int 37.5 40 7 33.4 -36.2 9 Int 27 40 7 33.5 -36.3 10 Int 75 40 7 31.9 -34.7 11 Int 37 40 7 33.4 -36.3 12 Int 53 27 7 33.5 -36.3 13 Int 36 39 7 33.5 -36.3 Prepared in accordance with: ASCE 7-16, Chaprer 311. Wind Lexmir - Components and C Wding. 7th Edwon (2020) Flanda Building Code. Page 1 of I