HomeMy WebLinkAbout215662-1pd Pool Backfill - signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB # :215662-1pd/BS/bm
PERMIT #:2102-0516
CONTRACTOR:A & G Pools NUC #528
Nuc Model:MC-1DR-P
9304 Scarborough Court Nuc Serial #:MD049528
Port St Lucie, Florida
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE
PERCENT
COMPACTION
1 South 0'-1'45 106.3 108.8 97.7%
2 1'-2'"-"95.0% +
3 2'-3'"-"95.0% +
4 3'-4'"-"95.0% +
5 East 0'-1'45 107.8 108.8 99.1%
6 1'-2'"-"95.0% +
7 2'-3'"-"95.0% +
8 3'-4'"-"95.0% +
9 North 0'-1'45 107.6 108.8 98.9%
10 1'-2'"-"95.0% +
11 2'-3'"-"95.0% +
12 3'-4'"-"95.0% +
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
7/23/2021PE # 81439
Disclaimer:Contractor is responsible to maintain the pool
backfill in the condition that KSM completed the indicated
passed compaction test.KSM is not responsible if the
poolbackfill has been altered from the approved inspected
condition.
Brown Sand
Minimum Requirement
Email to: abirmingham@angpools.com
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
2102044/Tripodi
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
12.0%
ITEM TESTED :
Soil Description:
108.8
Penetrometer reading indicate the
TEST LOCATION
OF SAMPLE
DATE TESTED:
In Place Moisture:
Respectfully Submitted:
PO:
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
9.5%
July 22, 2021
Pool Backfill Compaction
for Plumbed Backfill
JOB LOCATION:
Bryan E. Dahlke, P.E. V.P. of Engineering
Degree of Compaction Meets
103.0
104.0
105.0
106.0
107.0
108.0
109.0
110.0
7 8 9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight