Loading...
HomeMy WebLinkAboutHightower_ Water heater _Spec Sheet Water ncswtlntlal t10CtnC ' f Professional Classic Water Heaters 1 1 The new degree of comfort' Professional Classic® electric water heaters are engineered for longer life resistored heating elements and premium grade anode rod Efficiency Plus... • .90- .93 UEF • Rheemglae tank lining resists • isolated tank design reduces corrosion and prolongs tank life conductive heat loss • EverKleen'"self cleaning device fights • Resistored copper upper element and harmful sediment build-up with a resistored Lifeguard`"stainless steel high-velocity spiraling water stream— lower element to prolong anode rod helps operating efficiency by saving and tank life energy, money and improving tank life +' a f1 yw.r Performance •FHR:45-67 gallons, based on gallon • Enhanced-flow brass drain valve capacity •Temperature and pressure relief valve •Recovery:21 GPH at a 90' F rise included System Sentinel • HUD certified for manufactured (Available on selected models) housing and modular construction • Exclusive diagnostic system with • Low lead compliant glowing LEDs that verify heating Warranty element operation. LEDs pin point the exact location of functioning or non- 'warm limited tank and parts functioning heating elements warranty` •With Protection Plus"the 6-year limited Longer Life tank warranty becomes 10-year • Premium grade anode rod provides `See Residential Warranty Certificate for complete Professional Classic long-lasting tank protection information 19,9 to 55-Gallon Capacities Features Units meet or exceed ANSI requirements and have 240 Volt AC/Single Phase been tested according to the AHRI Operations Double and Single Element Models • Electric junction box located above Manual and D.O.E.procedures.Units meet or heating elements for easy installation exceed the energy efficiency requirements of Electric NAECA,ASHRAE standard 90,ICC Code and all •Over-temperature protector cuts state energy efficiency performance criteria. off power in excess temperature UL situations •Automatic thermostat keeps water at desired temperature See specifications chart on back. PRINTED IN U.S.A.o5/18 WP FORM NO.PROE RH N Rem.8 ' Water ( Hesltlential Electric I Professional Classic Water Heaters Professional Classic° Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGYINFO. T UEF UNIFORM Y NOMINAL RATED RRSTHOUR RECOVERY TANK HEIGHT TO APPROX. ENERGY P GALLON GALLON MODEL RATING IN G.P.H. HEIGHr WATER CONN. DIAMETER SHIP WT. FACTOR E CAPACITY CAPACITY NUMBER G.P.H. 9(r F RISE A B C (LBS.) (UEF) Tall 30 27 PROE30T2RH95T . 46 21 47-1/2 50-We 19-1/4 92 0.92 Tall 40 36 PROE40 T2 RH95T 55 21 60-3/4 63-5/8 19-1/4 109 0.93 Tall 50 45 PROE50 T2 RH95T 63 21 58-5/8 61-5/8. 20-1/4 121 0.93 Tall 55 55 PROE55 T2 RH94T 72 21 57 59 3/4 22-1/4 128 0.92 Med. 30 27 PROE30 M2 RH95T 45 21 37-1/2 40-1/2 20-1/4 92 0.90 Mea. 40 3D PROE40 M2 RH957 55 21 45-1/4 50-1/2 20-1/4 106 0.93 Med. 50 45 PROE50 M2 RH95T 62 21 48 50-1/2 23 132 0.93 Short 19.9 - PROE20$2 RH - 21 31-1/2 31-1/2 17 62 - Short 28 25 PROE28 S2 RH95 45 21 30 31-1/8 23 95 0.92 30 27 PROE30 S2 RH95 8— , 46 21 30-1/8 32 19-3/4 95 0.92 FShoorrt' 36 33 PROE36 S2 PH95 46 21 31-1/2 33 24-1/4 118 0.92 38 35 PROE38 S2 RH9E B"" St 21 31-1/2 32-5/8 23 108 0.92 47 1 43 PROE47 S2 RH95 54 21 32 34 26-1/4 149 0.93 Uniform Energy Factor and rated gallon capacity based on[;apartment c%f Energy(DOE)requirements. *System Sentinel optional.Add ECt to the end of the nx del number.System Sentinel not available on single 8" element models,available on dual element models only System Sentinel not avadable in excess of 5 kW on 2G6 V models. Water heater dimensions prior to installing insulation blanket that is incx:ded wit:l water heater. •Heaters furnished with standard 240 volt AC.single phase non-simultaneous worry.and 4500 watt upper and lower heating elements. •ff heating elements of different wattages than those shown are demanded HOT specifically by zone requirements,they must be WATER 0° Asa' CONNECTION COLD •Single element models available on special order(6000W max.).SututiMe"1"for"2"in model number. WATER Special Wiring Options—A limited number of special Wiring options are available.Consult factory for pdce and availability. RELIEF VALVE ® CONNECTION •All models equipped with heat traps. CONNECTION ANODE Recovery=wattage/2.42 x temp.rise'F. ROD Example: 450OW =21 GPH C 2.42 x 90" DIAMETER Recovery calculations used are based on 4500 watt dements used in non-simutaneous operation, A B FO WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of conGS;uous progress and product improvement,Rhee l reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow P.rkwoy,Suite 100 Roswell,Georgia 30076 • www.rhetm.corn OCIAITGO IAI U.C.A.ow�0 WP r'ORM No.'not RFI N HAY.a