Loading...
HomeMy WebLinkAboutAPPROVED, RC Home Showcase SHM IAM I•DADE MIA-NII—DADS COUNTY, FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315 2599 NOTICE OF ACCEPTANCE (NOA) www.n►iamidade.gov/eeonomv RC Home Showcase, Inc. 2970 NW 75's Avenue Miami, FL 33122 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County RER— Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In MiamiDadeCounty) and/ or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the`AHJ :may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "SH-075" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. W09-61, titled Series "SH075 Alum. Single Hung Window (L.M.I.)", sheets 01 through 04 of 04, dated 12/17/09 with revision "E" dated 02/17/15, prepared by Al— Farooq Corporation, signed and sealed by Javad Ahmad, P. E., bearing the Miami —Dade County Product Control Section Renewal stamp with the Notice of Acceptance number and Expiration date by the Miami — Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. REVISION of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, \Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 13-1112.17 and consists of this page 1 and evidence pages E-1, E--2, E-3, E-4 and Green Sustainable Attributes (G.S.A.) page G-1, as well as approval document mentioned above. The submitted documentation was reviewed by Jaime D. Gascon, P. E. NOA No. 15 0302.02 Expiration Date: May 19, 2020 �1 Approval Date: April 09, 2015 Z �� Page 1 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under previous NOA's No.'s 10-0209.04 and 10-0811.14) 2. Drawing No. W09-61, titled Series "SH075 Alum. Single Hung Window (L.M.I.)", sheets 01 through 04 of 04, dated 12/17/09 with revision "E" dated 02/17/15, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. and FTL-6247, dated 06/29/10, signed and sealed by Jorge A. Canso, P. E. (Submitted tinder previous NOA No. 10-0811.14) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411,3.2.1, and TAS 202-94 along with marked up drawings and installation diagram of an outswing aluminum Casement window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-6117, dated 12/02/09, signed and sealed by Michael R. Wenzel, P. E. (Submitted under previous NOA No. 10-0209.04) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, prepared by Al-Farooq Corporation, dated 02/10/15, signed and sealed by Javad Ahmad, P. E. 2. Glazing complies with ASTM E1300-04109 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. .MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kurara ricja� c. for their "Kuraray PVB Glass Interlayer" expiring on 12/11/Z� Jaime D. Gascon, PEE. - Product Control Section Supervisor NOA No. 15-0302.02 Expiration Date: May 19, 2020 Approval Date: April 09, 2015 E-1 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FBC Z) Edition (2014), issued by Al—Farooq Corporation, dated 02/11/15, signed and sealed by Javad Ahmad, P. E. 2. Statement letter of conformance, complying with FBC-2010, issued by Al—Farooq Corporation, dated 10/15/13, signed and sealed by Javad Ahmad, P. E. (Submitted under previous NOA No. 13-1112.17) 3. Name changed to RC HOME SHOWCASE, INC. as registered in the Florida Department of State, Division of Corporation, Sunbiz document dated 10/11/131 (Submitted under previous NOA No. 13-1112.17) 4. Asset purchase agreement dated 10/01/13, signed by Mr. Manuel A. Kronfle— Kozhaya, Mr. Henry F. Kronfle—Kozhaya, Mr. Raul Casares, Mr. Eusebio Paredes and Ms. Nancy Vias. (Submitted under previous NOA No. 13-1112.17) 5. Statement letter of complying with the Sales of Assets issued by RC Aluminum Industries, Inc., dated 10/30/2013, signed by Raul Casares, President. (Submitted mtder previous NOA No. 13-1112.17) 6. Department of State Certification of RC HOME SHOWCASE, INC, as a for profit corporation, active and organized under the laws of the State of Florida, dated 10/11/13 and signed by T. Carter, the Secretary of State. (Submitted under previous NOA No. 13-1112.17) 7. Department of State Certification of MANUHEN ENTERPRISES, LLC as a limited liability company, active and organized under the laws of the State of Florida, dated 08/22/13 and signed by N. Culligan, the Secretary of State. (Submitted under previous NOA No. 13-1112.17) 8. Laboratory compliance letters for Test Report No. FTL-6247, dated 06/29/10, issued by Fenestration Testing Laboratory, Inc., signed and sealed by Jorge A. Causo, P.E. (Submitted underprevious NOA No. 10-0811.14) 9. Proposals issued by Product Control, dated 03/02/10, signed by Manuel Perez, P. E. (Submitted under previous NOA No. 10-0811914) 10. Laboratory compliance letters for Test Report No. FTL-6117, dated 12/02/09, issued by Fenestration Testing Laboratory, Inc., signed and sealed by Michael R. Wenzel, P. E. (Submitted ender previous NOA No. 10-0209.04) 11. Proposals issued by Product Control, dated 02/24/10, signed by Ishaq Chanda, P. E. (Submitted tinder previous NOA No. 10-0209.04) G. OTHERS 1. Notice of Acceptance No. 13-1112.17, issued to RC Home Showcase, Inc. for their Series "SH-75" Aluminum Single Hung Window — L.M.L", approved on 12/26/13 and expiring on 05/19/15. Q Jaime D. Gascon, P. E. Product Control Section Supervisor NOA No. 15-0302.02 Expiration Date: May 19, 2020 Approval Date: April 09, 2015 E-2 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED G. OTHERS (CONTINUED) 2. Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance, & Condensation Resistance Calculation Report on: 1) NFRC 100-2004 "Procedure for Determining Fenestration Product U—Factors" 2) NFRC 200-2004 "Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence" 3) NFRC 500-2004 "Procedure for Determining Fenestration Product Condensation Resistance Values" Using computer simulation in accordance with NFRC: Frame and Edge Modeling: THERM 5.x, / WINDOW 5.x NFRC Simulation Manual (Approved at test date), of a RC Aluminum Series "CM100" outswing casement aluminum prime window, along with attached drawings and bill of materials included in Appendix A, marked —up by National Certified Testing Laboratories, Test Report No. NCTIr110-12449.01, pages 01 through 07 of 07, dated 11/12/09, signed by Richard A. McVicker III, Simulator, and Steven H. Coble, NFRC Accredited Simulator, Simulator —In —Responsible —Charge. (Submitted under previous NOA No. 10-0811.14) 3. NFRC 102-2004 Thermal Performance Test Report on: 1) NFRC 102-2004 "Test Procedure for Measuring the Steady State Thermal Transmittance of Fenestration Systems" Test 'report of a series RC Aluminum's Series "CM100" Outswing Aluminum Casement Prime Window with Low E and Argon, along with submittal component drawings, with applicable part numbers, manufacturing and modeling details included in Appendix A, marked —up by National Certified Testing Laboratories, Test Report No. NCTIr110-12450-1, pages 01 through 04 of 04, dated 11/30/09, signed by Christian J. Mitchell, Technician, and Robert H. Zeiders, P. E., Vice —President Engineering & Quality Person —In —Responsible Charge. (Submitted under previous NOA No. 10-0811,14) 4. Recycled Content Determination Report on: Name: Casement Window, CM100 Raw Material: Aluminum Including letter from Fundieiones Industriales S.A. (FISA) dated 03/22/103 certifying that the extruded aluminum products contained 30% recycled scrap material, signed by Henry Kronfle, Vice —President. (Submitted under previous NOA No. 10-0811.14) Jaime D. Gascon, F E. Product Control Section Supeiwisor NOA No. 15-0302.02 Expiration Date: May 19, 2020 Approval Date: Apri109, 2015 E-3 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED GREEN SUSTAINABLE ATTRIBUTES IGSA) SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control G A —RECYCLED CONTENT / Bl0-BASED MATERIAL / RAPIDLY RENEWABLE;MATERIAL Component Name % Recycled Content at % Recycled at Disposal % Bio-based Material % Renewable Material ManuL 1. Window Aluminum 30% 100% N/A N/A (Submitted under previous NOA No. I0-0811.14) GS U—FACTOR THERMAL TRANSMITTANCE BTU/HR FT F G.9—SHGC—FACTOR-.(SOLAR -HEAT GA IN COEFFICIE NT) BTU/ HR-FT T: VISIBLE LIGHT TRANSMITTANCE AT NORMAL INCIDENCE CR— CONDENSATION'RESISTANCE ; : G.S .8 1D# Test Product Glazing Components: G.9. VT C Report#: Number SHGC R Factor Base line 000 AL 3/16 BRNZ 240#2- SS-D ARG- BRNZ-1/8 090 PVB 1/8- AL 0,64 N/A N/A NI Product - - - - - - A A 1. 001 AL_5/32_BRNZ_240#2_SS-D_ARG_BRNZ-1/8_090PVB_1/8_AL 0.64 0.21 0.21 15 2, NCTL 002 AL_5/32 CI.R_240#2 SS-D_ARG_CLR-1/8_090 PVB_I/8_AL 0.64 0.22 0.29 15 3. 110-12453-1 003 AL_5/32_CLR_240#2_SS-D_ARG_GRN-1/8 090 PVB-1/8-AL 0.64 0.21 0.20 15 4. 004 AL 5/32 CLR 24092 SS-D ARG GRY-1/8 090PVB 1/8 AL 0.64 0.21 0,27 15 (Submitted under previous NOA No. 10-0811.14) Component Namc 1. Whole Window Le end Abbreviations: Descrintion: SS-D Desiccant -Filled Stainless Steel Spacer 240#2 Cardinal Low E 240 @ #2 Surface Typical ARG 90% Argon PVB 0.090" Poly Vinyl Butryal (PVB) interlayer CLR Clear Glass BRZ Bronze Tint Glass GRN Green Tint Glass GRY Gray Tint Glass AL Aluminum Frame C-Value (Submitted zouler previous NOA No. I0-08I1.14) Jaime D. Gascon, Product Control Section Supervisor NOA No. 15-0302.02 Expiration Date: May 19, 2020 Approval Date: April 09, 2015 G-1 EQUAL LITES WINDOWS DESIGN LOAD CAPACITY -PSF WINDOW DIMS. 5/16" LAM. GLASS WIDTH HEIGHT EXi.(+) iNT.(-) 19-1/8" 24" 26-1/2" 30" 37" 42" 48" 53-1/8" 26 (4) 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 so.o 1s-1/s" z4" 26-1/2" 30" 37" 42" 48" 53-1 /8" 38-3/8" (5) as.o so.o es.o so.o 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 19-1/8" 24" 26-1/2" 30" 37" 42" 48" 53-1/8" 50-5/8" (7) 85.0 90.0 85.0 - 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 71.4 75.5 19-1/8" 24" 26-1/2" 30" 37" 42" 48" 53-1/8" 58 (7) 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 B5.0 90.0 85.0 90.0 70.0 70.0 19-1/8" 24" 26-1/2" 30" 37" 42" 48" s3-1/B" 6� () 85.0 90.0 65.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 70.0 70.0 19-1/8" 24" 26-1/2" 30" 37" 9 () 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 UNEQUAL LITES WINDOWS DESIGN LOAD CAPACITY -PSF WINDOW DIMS. 5/16" LAM. CLASS WIDTH HEIGHT EXT.(+) 1Ni.(-) 19-1/8" 24" 26-1/2" 30" 37" 42" 48" 53-1/8" 38-3/8" (5) 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 65.0 90.0 B5.0 90.0 85.0 90.0 2a" 26-1/2" 30" 37" 42" 48" 50-5/8" s as.o sa.D 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 70.0 70.0 24" 26-1/2" 30" 37" 42" 58" (7) 85.0 90.0 85.0 90.0 85.0 90.0 85.0 90.0 70.0 70.0 19-1/8" 24" 26-1/2" 30" 37" 63„ b) 85.0 90.0 85.0 90.0 85.0 90.0 Bs.o so.o 70.0 70.0 19-1/8" 24" 76 85.0 90.0 85.0 90.0 * NO. IN PARENTHESIS INDICATE NO. OF ANCHORS PER JAMB. �� 4 ��.aimo UNEQUAL LITES (ORIEL TYPE) /8" HEAT STREN'D GLASS .090" Interlayer DuPont Butacite PVB By 'E.I. DuPont De Nemours & Co., Inc. 1 /8" HEAT STREN'D GLASS � r SILICONE z m M4 DOW CORNING 791 � � \ �RI I 1 I it / \ ry n w 5/16" OVERALL LAM. GLASS GLAZING DETAIL SH075 ALUMINUM SINGLE HUNG tiVINDOW DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHART SHOWN ABOVE. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. 47 1/2" U � D,L. OPG. A! 1O ,Y o 11" MAX. Z � HEAD x � p � W a 4" MAX. HEAD � � � Q W � as CORNERS � A � � o p�, � O O m � OW li II � 0 a D i i i i ,p,++ c�i ti \ O I 4I V � .i nJ ---�== i---__ � O w M o g i t i/ l i � p a a o a.°pa � II ,/ .I p � n - d � O N �3 � aw3uGi N= o o I' I �?NE M 3 x - li it E J c7 ro Q \w \o _ ;I I; aW�€� x n m - --=II-- -=11-ov== � O z r` o I I =_ X m N � � N C I. / III '.. s Q � ,r�i J j a tO 3 a O o ^ z_ m FALSE MUNTINS 47 7/16" n � W w MAY BE USED D.L. OPG. z Q Z a = U j 50 5/16" ?� ¢ VENT WIDTH � O = N a Z = � N N !n u� 53 1/8" v7 n fMj WINDOW WIDTH � � 3 J � ¢ Oz�` � TYPICAL ELEVATION ,,, _ - M r` � � v o Urn ¢ � = D= N � r C� THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ` N0. IN PARENTHESIS INDICATE N0. OF EQUAL LITES ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS ANCHORS PER JAMB. EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. 1�, •, - ��� 1 : G/(IL / r � � ' _ THESE WINDOWS ARE RATED FOR LARGE &SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. FLA. PE (/ 70592 G:A.{J. 3538 `£ p � m � � o o U a � w y N � w o C � w � o vo c o n it o � n � i drawing no. W09-61 of TYPICAL ANCHORS SEE ELEV. METAL TYPICAL ANCHORS FOR SPACING STRUCTURE 1By SEE ELEV, UCK FOR SPACING Y TYPICAL ANCHORS _ m u SEE ELEV. a. a -a:. a. m FOR SPACING o 0 N 0 0 m03 MIAMI-DADE COUNTY APPROVED MULLION & MULLION ANCHORS SEE SEPARATE NOA I �. ri TYPICAL ANCHORS SEE ELEV. FOR SPACING w1 10 i vz a WOOD BUCKS AND METAL STRUCTURE NOT BY RC HOME SHOWCASE MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING �4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) 1 /4" HILTI KWIK—CON II (Fu=163 KSI, Fy=157 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONIC, OR MASONRY 1-1/4" MIN, EMBED INTO CONC, OR MASONRY DIRECTLY INTO CONC. OR MASONRY 1-1/4" MIN. EMBED INTO CONIC, OR MASONRY #14 -SELF DRILLING SCREWS (GRADE 5 cRs) INTO MIAMI—DADE COUNTY APPROVED MULLIONS (MIN. THK. = 1/8") NTO METAL STRUCTURES STEEL 1/8" THK. MIN. (Fy = 36 KSI MIN.) ALUMINUM 1/8" THK. MIN. (6063—T5 MIN.) LO (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) ANCHOR EDGE DISTANCES INTO CONCRETE AND MASONRY = 1-3/4" MIN. NTO WOOD STRUCTURE = 1" MIN, INTO METAL STRUCTURE = 1" MIN, WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. SEALANT: ALL FRAME AND VENT CORNERS AND INSTALLATION SCREWS SEALED WITH SILICONE. WEEPHOLES: W1 = 1-1/4" WEEP NOTCH AT EACH END CML FLA. PE (� PRODUCT RENEW GD CA.N. 3[ us mmplyhrB wld�lhu Florida Duild'utg Code /1 G. Q Acceptance No11.�+ �DL o Date ZD ey Miami Dade Product Con" ro J � a � a O z_ w 3 W w z Q z � Uw x 3'a J (1 CV a x N Z f- N � W n Ozl'-,n 2 -n oxrw- !n � D N 0 4 i w w o � z � c v Noy a v o c drawing no. W09-61 sheet 2 of 4 N PART /� REQD. DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS E1 SH075-006 1 FRAME HEAD 6063-T6 - E2 SH075-009 1 FRAME SILL 6063-T6 - E3 SH075-012 1 FIX. MEETING RAIL 6063-T6 - E4 SH075-007 2 FRAME JAMBS 6063-T6 - ES SH075-010 1 VENT TOP RAIL 6063-T6 - E6 SH075-011 1 VENT BOTTOM RAIL 6063-T6 - E7 SH075-005 2 VENT JAMB STILE 6063-T6 - E8 SH075-008 4/ LITE 5/16° GLASS STOP 6063-T6 - E9 500Y-026 OPTIONAL EXTRUDE FRAME SCREEN ALUMINUM - E10 500Y-030 OPTIONAL SCREEN CORNER LOCK - - V1 V-100 AS REQD. OUTSIDE WEDGE - DUROMETER 65t5 SHORE A V2 V-099 AS REQD. "V" GASKET FOR BOTTOM VENT - DUROMETER 65t5 SHORE A M1 W31141NK AS READ. WEATHER STRIPPING PILE ®MEETING RAIL - - M2 W31201 NK AS REQD. WEATHER STRIPPING PILE - M3 W31291NK AS REQD. WEATHER STRIPPING PILE - - M4 DC-791 AS REQD. SILICONE - DOW CORNING MS V-2100 AS READ. 3/16° x 5/16° SINGLE PACE TAPE - NORTON M6 100 SERIES 2 SIDE LOAD BLOCK &TACKLE: - - - 2 TOP GUIDE N104 NYLON - - - 2 BOTTOM GUIDE N110 NYLON - - - - TERMINAL CHIP N135 - - - - - TAKE OUT CLIP N121 - - M7 X100-236 - SASH CAM FOR BLOCK &TACKLE BALANCE - - MB 022ST190 1 p-LON WEATTHERSTRIPPING - - M9 - - 1/8" x 1/8" x 4" LG SETTING BLOCK EPDM DUROMETER BOf5 SHORE A M70 LL-200 2 SPRING LOADED LIFT LATCH PLASTIC AT 9-1/2' FROM EACH END PI P-053 - VENT GUIDE PLASTIC - P2 P-054 - VENT STOP - MELTPOINT 51 - AS REQ. ASSEMBLY SCREWS (N6 x 1° LG PH. SMS) ST/ST S2 - - N6 x 3/8" LG FH. SMS ST/ST - U 4 I 0 Z J 0 im m N Q ea W I Yi N d (L 0 c O 0w 0G a Oa m a 0 > M G 0 a. QO e1 0°6�a� N00p Q W 3 iL N LL ZU : o _ M TYPICAL ANCHORS ,J M Q MIAMI-DADE COUNTY SEE ELEV. a W H APPROVED MULLION FOR SPACING SEE SEPARATE NOA N m J j a 3 a O -- - — - - - -OP W WO ZZUw_________ _�Q =-_— -- — W b N a Z S __ N N N (n � I 111 n 7 N J M WINDOW WIDTH WINDOW WIDTH Q O Z � = o O r o O) Q TYPICAL ANCHORS �' cq SEE ELEV. FOR SPACING 0 1/4" MAX. SHIMS TYPICAL ANCHORS 1/4" MAX, D EO SEE ELEV. SHIM TYPICAL ANCHORS FOR SPACING VENT WIDTH LFG ELEV. SPACING M6 M7 52 Pi 1/40 SHIM MAX. E7 -- - Y WOOD 8 K 0 ° R - - - - - - WOOD STRUCTUR 0 M3 10 M3 1BY Engr: JAVAD AHMAD EXTERIOR WOOD BUCKS CIVIL E4 FLA. PEN 70592 a D.L. OPG. _ v, C.A.N. 3538 ODUCT RF.NFWF.D — comPlyhlg velth the Florida A a a WINDOW WIDTH Bul I� ..aCC No 0��� QZ 015 O AcuP to Dam /ZQP(� drawing no. METAL _ W09-61 STRUCTURE Miami Dade Product Coll sheet 3 of 4 ITEM z �m a w N N w � C O � � N p d oa c 1 t 1 FRAME HEAD MEETING RAIL VENT TOP RAIL Ea FRAME JAMB iLL I � 2.134 2.510 1.169 .050 t. H .868 L Es VENT BOTTOM RAIL C2 1.4551 575 .804� 070 I .050868 � i .675� E7 VENT SIDE RAIL 750 832 .075 d .654 GLAZING BEAD t&Y.7 .755 � I .574 �i ,875 lo- SPRING LOADED LATCH PLASTIC FRAME SILL C VENT CORNER DETAIL I'RODUCf itCiNEWLD as complying wlth the Florida Uuilding Code ���,0� Acceptwrcc No Ex ' n ate fly Miami Dade Pro ud C011(ro1 St FRAME CORNERS DETAIL (:ML FLA. PE b 70592 �C.A.N.n35389 2m z QW N N 21 O 0 0 W `✓ Q; O O M p�>M00 pa¢o,, 0 Q 0 W3LL {LZN:M J Z N Q J Qwri�r N - 0 J a 3 a O Z_ a0 Z Q z LL � Uw x 3a J O N x � W n a Ozw � n !n � � O N � � N 910 0 � 0 � o < drawing no W09-61