HomeMy WebLinkAboutAPPROVED Fireplace SpecsA
A
B B
SECTION B-B
HORIZONTAL FIREBRICK DETAIL
TOP VIEW
SECTION A-A
VERTICAL FIREBRICK SECTION
FRONT VIEW RIGHT-SIDE VIEW
MINIMUM 114" THICK FIREBRICK
W/ 14" MORTAR.
(FOR CLARITY, BRICK NOT
SHOWN ALONG BACK WALL)
MINIMUM 114" THICK FIREBRICK
W/ 1 4" MORTAR.
211
2"
34"
301
8"315
8"
421
2"
427
8"
37"
631
4"
3"
Ø135
8" FLUE OUTLET
34"
183
4"
183
4"
11
2"
251
4"
301
8"
631
4"
640
[25 3/16"]
211
2"
427
8"
103
4"
11
2"
11
2"
11
2"
247
8"
MINIMUM 114"
THICK FIREBRICK
W/ 1 4" MORTAR.
6899 Phillips Industrial Blvd.
Jacksonville, Fl. 32256
PROJECT:
MATERIAL:
SIZE:
APPROVED:
DESCRIPTION:
UNLESS OTHERWISE STATED, ALL
DIMENSIONS ARE IN MILLIMETERS
ANG..X
THIRD ANGLE
PROJECTION
.X
.XX
XLIN.DRAWN:
D
SCALE:
DO NOT SCALE OF
DATE:
DATE:REV:DRAWING #:
SHEET #
UNSPECIFIED
TOLERANCES
±
±
±
±
36" STANDARD (80s36)
FIREPLACE CONSTRUCTION DOCUMENT
E.C. PUMICE MIXTURE
K.B.H 9/1/2020 1-1/2"=1'-0"80s36
1 2
C
MINIMUM
114" THICK FIREBRICK
W/ 1
4" MORTAR
COMPONENT LIST
PART #DESCRIPTION QTY.
11 SMOKE DOME (MIDDLE)2
20 SIDE WALL 6
21 BASEPLATE-36" (STD)1
25 BACKWALL-36" (STD)3
34 TOP SLOPING 2
68 DAMPER BEAM-36"2
77A TOP PLATE W/345mm HOLE 1
95L DAMPER END; LEFT 1
95R DAMPER END; RIGHT 1
ISOMETRIC VIEW (N.T.S)
GENERAL NOTES
DETAIL A
DAMPER SUPPORT ANGLE
9.5 [3/8"]
101.5
[4"]
101.5 [4"]
SIDE WALLS MUST BE
NOTCHED SO THAT ANGLE
IRON WILL SIT FLUSH WITH
TOP OF WALL
DETAILS (N.T.S)
A
NOTE: WHENEVER THE MAXIMUM DM CHIMNEY HEIGHT OF 57' IS EXCEEDED, OR IN
ANY INSTANCE WHERE THE ISOKERN BRICK LEDGE IS USED, IT IS REQUIRED THAT
THE FIREBOX/SMOKE DOME ASSEMBLY INCLUDE THE PLACEMENT OF A 4" BY 4" BY
3/8" MINIMUM STEEL ANGLE ACROSS THE FIREBOX OPENING. (SEE DETAIL A)
1.FIREPLACE SHALL BE INSTALLED WITH THE MINIMUM CLEARANCES TO COMBUSTIBLES AS LISTED BELOW:
·UNIT FRONT AND ISOKERN CHIMNEY: 0"
·SIDES AND REAR: 1.5"
·COMBUSTIBLE SHEATHING ABOVE OPENING TOP: 8"
·SHEATHING OR TRIM TO OPENING SIDES: 8"
·MANTLE ABOVE OPENING: 14"
·OPENING TO SIDEWALLS: 26"
·HEARTH EXTENSION BEYOND FRONT: 20"
·HEARTH EXTENSION BEYOND SIDES (FINISHED): 12"
·COMBUSTIBLE FLOOR: 4"
·INSULATION FROM FIREBOX (UNSHIELDED): 3"
2.UNLESS THE FIRELITE KIT IS UTILIZED, THE FIREPLACE AND NONCOMBUSTIBLE HEARTH EXTENSION SHALL REST ATOP
A NONCOMBUSTIBLE FLOORING SYSTEM WITH NO WOODEN UNDERPINNINGS.
3.IF YOU INSTALL A VENTED GAS LOG SET (DECORATIVE GAS APPLIANCE), THE LOG SET MUST COMPLY WITH THE
STANDARD FOR DECORATIVE GAS APPLIANCE FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES, ANSI Z21.60 OR
Z21.84 AND SHALL ALSO BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FUEL GAS CODE, ANSI 7223/ NFPA 54;
LATEST EDITION. IF YOU WISH TO INSTALL AN UNVENTED (VENT-FREE) GAS LOG SET, ONLY UNVENTED GAS LOG SETS
WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS, ANSI Z21.11.2 ARE TO BE
INSTALLED IN THIS FIREPLACE. CHECK LOCAL CODES FOR COMPLAINCE FOR UNVENTED (VENT FREE) GAS LOG SETS.
4.4" COMBUSTION AIR INLET KITS ARE RECOMMENDED BY EARTHCORE FOR THE STANDARD AND MAGNUM SERIES
FIREPLACES AND MAY HELP IMPROVE FIREPLACE OPERATION IN HOMES TIGHTLY SEALED AND WITH OTHER
VENTILATING APPLIANCES INSTALLED. IF THE INSTALLATION IS TO BE LONGER THAN TEN FEET (10'), THEN THE SIX INCH
(6") ADAPTER WILL BE NEEDED. THIS ADAPTER WILL ATTACH TO THE EXISTING FOUR INCH (4") SLEEVE OUTSIDE OF THE
UNIT. THE SIX INCH ADAPTER INCLUDES AN ADDITIONAL TWENTY FEET OF 6" FLEX HOSE, FOR A MAXIMUM RUN OF
THIRTY FEET (30').
5.DRAWINGS ARE FOR DESIGN PURPOSES ONLY AND ARE THE SOLE PROPERTY OF EARTHCORE INDUSTRIES. ANY
REPRODUCTION OR UNAUTHORIZED USE IS STRICTLY PROHIBITED.
6.EARTHCORE/ ISOKERN OR ANY DIVISION THEREOF SHALL NOT BE HELD LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE FIREPLACES OR CHIMNEY SYSTEMS.
7.ALWAYS CHECK LOCAL BUILDING CODES GOVERNING FIREPLACES AND FIREPLACE INSTALLATIONS.
Standard Series (All Fuel)SpecificationsMANUFACTURER:ISOKERN Fireplace and Chimney Systems, North America distribution byEarthcore Industries, LLC, Jacksonville, Florida (Telephone 800-642-2920)PRODUCT DESCRIPTION:Modular refractory masonry precast fireplace and chimney components.1.Designed for field assembly as a fireplace and chimney unit.2.All interlocking parts necessary for assembly of a complete firebox andsmoke dome.3.Interlocking double module chimney components (DM).MATERIALS:A.Light weight concrete of a proprietary mixture of Icelandic volcanicaggregate and cement for precast firebox, chimney block and flue linercomponents.1.Compressive Strength: Firebox and Chimney Block: 972 psi.2.Compressive Strength: Flue Liner: 1175 psi.B.Premixed (dry) EARTHCORE ADHESIVE.1.Tensile strength: 807 psi; Compressive strength: 2460 psi.2.Tested per ASTM C109, ASTM C307, and ANSI 118.4.C.Standard 1-1/8” thick high temperature refractory brick to line fireboxinteriorD.Standard cast iron poker-style damper (optional top mount or in-linedamper available).INSTALLATION:A.Reference manufacturer’s installation instructions for standardconfigurations, weights, sizes and installation details.B.Suitable masonry foundation and noncombustible hearth extensions mustbe provided.C.Unit to be assembled on site per manufacturer’s illustrated instructions.1.Premixed EARTHCORE ADHESIVE is used at all joints betweencomponents.2.Firebox to be lined with a minimum 1-1/8” thick rated firebrick.D.A 1-1/2” minimum clearance to combustible materials is required.E.A 3” minimum clearance to insulation required.CERTIFICATION:A.Warnock Hersey/Intertek Testing Services Report No. 632-912500;3159656MID008; 3082504-T1B.Meets or exceeds UL 103HT; UL 103; UL 127; UL 1777; ULC 5610; ANSI223.1.CODE COMPLIANCE:A.SBCCI NO. 9626B.LARR NO. 25483C.NYC-MEA 241-90-ED.ICC REPORT NO. ESR 2316E.IBC 2006, IRC 2006, IMC 2006NOTE: Isokern components are a natural material and slight variations indimensions may occur. These should be no more than 1/8”.SCAN QR CODE FOR LATESTINSTALLATION MANUALS6899 Phillips Industrial Blvd.Jacksonville, Fl. 32256PROJECT:MATERIAL:SIZE:APPROVED:DESCRIPTION:UNLESS OTHERWISE STATED, ALLDIMENSIONS ARE IN MILLIMETERSANG..XTHIRD ANGLEPROJECTION.X.XXXLIN.DRAWN:DSCALE:DO NOT SCALEOFDATE:DATE:REV:DRAWING #:SHEET #UNSPECIFIEDTOLERANCES±±±±36" STANDARD (80s36)GENERAL INFORMATION AND SPECIFICATIONSK.B.H9/1/2020N.T.S.80s3622C