HomeMy WebLinkAboutBldg A Pad 239546-1 DT-ds 07.26.21G���NtAi • cEorFcti
2 Universal Z&xg Sciences
• • •--
02
G
9(S TFSiING'`N�e�
•
UES Project No: 3310.2000257.0000
Workorder No: 239546-1
Report Date: 07/26/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: Baron Island Storage, LLC UES Technician: Nakia Sutton
49 SW Flagler Avenue Suite 301 Date Tested: 07/26/2021
Stuart, FL 34994
Project: Baron Island Self Storage
9500 South Ocean Drive, Jensen Beach, County, FL 34957
Type of Test:
Area Tested: Building A - Pad Field: ASTM D-6938 Nuclear Gauge Method
Material: Fill Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Center Of Pad A
0-1 ft
108.1
11.6
106.8
10.6
99
Pass
2
NW Corner Of Pad A
0-1 ft
108.1
11.6
107.3
10.5
99
Pass
3
SE Corner Of Pad A
0-1 ft
108.1
11.6
107.0
9.9
99
Pass
Remarks: Permit:2010-0252
Reviewed By
GFA International, Inc
FBPE Registry No.4930
\ `SOOMINIC,190''.
* ; N. 84146
STATE OF
uniinN
Digitally signed by Thomas
D
Monta no:A014100000001
7818498DCD000019A3
Date: 2021.07.26 14:45:55
-04'00'
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Dominic
Montano on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1