HomeMy WebLinkAboutBuilding PlansLIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER LAMP VOLTS MTG, NO ES SIZE QUAN_ A WILLIAMS 50G.524-232-S-A12125-EB2-UNV 32WTS- 3W,0K 2 MT RECESSED 2 FLUOR, TROFFER- NOTE 3 B WILLIAMS 17-2-217-A-EB2-UNV 17W T8- 3000K 2 MT CEILING 2 . FLUORESCENT WRAP W hED,�,30Q -,- TT� ,. - L-E STRT T& L-- DI INTENSE IML6L1309-C SFW-tLC6-L2 12W LED- 3000K NIA 120 RECESSED 6" DOWNLIGHT - NOTES 1,3 02 INTENSE IML6L2309-C-SFW-ILC6-L2 17W LED - 3000K N/A 120 RECESSED 6" QOWNLIGHT - NOTES 1;3 D3 INTENSE 1ML6L33Q9-C-SFW4I_C6-L3 26WLED -3000K N/A 120 RECESSED 6" OOWNLIGHT- NOTES I,3 D6 INTENSE IML6LI309--C-SFW-ILC6-L2-D10 12W LED 3000K N/A 120 RECESSED V' WNLtGHT- NOTES 1,3 07 INTENSE IML6L2309-C-SFW4LC6L2-D10 17W LED - 3000K N/A 120 RECESSED 6" DOWNLIGHT - NOTES 1,3 D8 INTENSE IML6L3309-C-SFW-ILC6-L3-D10 26W LED - 3000K N/A 120 RECESSED 6" DOWNLIGHT NOTES 1,3 D9 INTENSE IML6L4309-C-SEMI tL£6-L4-D;L0 38W LED - 3000K N/A 120 RECESSED 6" OOWNLIGHT- NOTES 1,3 -ter <_ ✓'_ MR-SL '✓ " ./-.i"Z 7Y1f6 ✓' ,67 ✓AIE ✓ -s .,' Ei�RAEi2E4d T1OIfT ' iL-DRTR-AIC-L1309D1QW 16, / F1 INTENSE RTRD300C-SFW 14W LED - 3000K N/A 120 RECESSED 4" DOW LIGHT- IC RATED �� ; N6F,; �v`-<„' ; =" 14�1C#(1',4WStcI(C��;�"`',%�%_' `x�, '�i2�3�` �. -- �. ` ✓ � �, ` � � ;fit TE .,, LD8A 60-A-OE010-ER8A6D-9- G PORTFOLIO 309LMI-H 77W LED - 30001( NA 120 RECESSED 8" OWNLIGHT- NOTES 1, 3 H NTTNS" _ (4 C 9WW�{l Dj �� SWAP R2fTLE[S �� 10 " CTSSED� - 4 WNLfGHTNOTE 4� K DAY-BRITE WTN-24W-L U-FWT-WT 24W-4100K LED N/A 120 WALL IV A.F.G. LE WALLPACK L INTENSE S56G21100308 16W LED - 30001( N/A 12Q RECESSED SHOWER LIGHT NOTE 1 M WILLIAMS 50G 524-332-S-Al2I25-EB2 UNV 32WTS-3000K 2 MT RECESSED 2x FLUOR. TROFFER A,i,- _..INTENSE-,_, .r ✓ IGRL`u465A C SE�.� _. - iOVIE�C1r3Q40>�/-, 2$ �aCE�� ' �N.�lGHT'R£�RQFkT, NOTE -9,- O P Q R LITON LHLWARLD219 W-04A 4W LED -3OWK N/A 120 RECESSED 2" DOWNLIGHT -NOTE I SS LITHONIA RV8,30-25-R48-AR-120-TRW 34W LED - 3000K NA 12D RECESSED B" DOWNLIGHT RETROFIT NOTE 9 S2 LITHONIA RV830.31)-1108-AR-120-TRW 42161 LED- 3000K NA 120 RECESSED 8" DOWNLIGHT RETROFIT - NOTE 9 RV8 30-30-R08-AR-120- S3 LITHONIA TRW/RG8RGINIFB 42W LED - 3000K NA 120, RECESSED 8" DOWNUGHT T LITHONIA RV6-30-15-1106-AR-120-TRW 23W LED- 3000K NA 120 RECESSED 6" DOWNLIGHT RETROFIT - NOTE 9 V NOT USED W IMPACT LI6HT'ING IL-TG-U&WW 3000K-12V"P LED 1.5WJLF NA 12 COVE LED COVE LIGHTING - NOTE 6 X1 BEGHELLI FME-SA-LR-I-WW+F LED N/A 120 CEILING EXIT SIGN - SINGLE FACE X2 BEGHELLI FME-SA-LR4-WW-FF LED N/A 120 WALL EXIT SIGN -DOUBLE FACE LIGHTING FIXTURE SCHEDULE NOTES 1. PROVIDE T€NMAT BARRIER BOX OR Et1UAL FOR INSULATION SEFARPIN WHERE 1tfQU}RED __ _. _ ��.L�MRY2YSlt11-Til'!}.f',Y�.-ECL/#tiSZC OP LF1�i tf\PIhY.�1%E���%'.-ter \�'`��-�./^ — ✓�l/ .. �✓�r"�� �. �.'r -�i.,-..\. \. "fir-`..i �_'�/-� 3. FIXTURE TYPES AE, CE, DIE, D2E, D3E, D6E, WE, DBE, D9E, FIE, GE, ME, OE, AND PE SHALL BE THE SAME AS TYPES AC, DI, D2, D3, D6, D7 , D9, F1, G, M, 01 AND P RESPECTIVELY EXCEPT THEY SHALL CONTAIN AN EMERGENCY BATTERY BALLASTS. BALLASTS SHALL PROVIDE 1400 LUMENS FOR LINEAR LAMPS AND 700 LUMENS FOR CF/LED LAMPS. ._..,., __._.__ .-___ ._...._: _,... .-___...__ \ � r � � �� _� ... :me ._..,_.. � µ_,...- -... i ..� .._....._....... .......�� ,.,..,. m-.- R E/HITECT�TERIO DESIGNER,: S�tFIXTURE NOUNTtNGH€I�;HTASCftRECTEDt�IN 6.PRt VIDE AN IMPACT L%HTING # IL TRS-D1MA _._ „ 110 TRANSFORMER FOR COVE I IGHTlP1S .- ' 7. I FOR BEST EFFECT u. .. _ _.w :Ft7tTl1RFF5HAtL-BE'4NSTALLED'ONTk2P'GIFLQCIFERS:,FAC r--✓ ✓ i ✓ ., `•r ------------- _ _.: i r 9. FIELD V€IRY RETROFIT COMPATABtLITY PRIOR TO ORDERING. � n n t t GENER AL NOTES. ( ELECTRICAL CONTRACTOR SHALL VERIFY ALL FIXTURE LOCATIONS AND MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS:' (2) EXHAUST HOOD LIGHTS SUPPLIED WITH HOOD AND INSTALLED BY ELECTRICAL CONTRACTOR. Q REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE DRAWINGS. THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATIONS DIRECTLY UPON CONTRACTOR. (3) SEPARATE GREEN GROUND CONDUCTOR SHALL BE ROUTED IN ALL CONDUITS WITH ALL PHASE CONDUCTORS. © ALL MECHANICAL EQUIPMENT SHALL BE COMPLETELY CONNECTED BY ELECTRICAL CONTRACTOR INCLUDING BOTH POWER AND CONTROL WIRING. ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING AND CONTROLS OF MECHANICAL UNITS AND THERMOSTAT LOCATIONS. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS FOR CLARITY ONLY, ELECTRICAL CONTRACTOR MAY GROUP SINGLE POLE BRANCH CIRCUITS IN MULTIPLE CIRCUITS HOME RUNS. (3 CIRCUITS MAX ® 120/208V 30, 2 CIRCUITS MAX ® 120/24OV. 30 & 10). A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL POWER, RECEPTACLE, AND LIGHTING CONDUITS. ® ALL EXTERIOR CONDUIT FOR ROOF MOUNTED EQUIPMENT AND WIRING SHALL BE MINIMIZED BY ROUTING IN CEILING SPACE. NO EXTERIOR CONDUIT WILL BE ACCEPTED. Q9 ALL CONDUITS SHALL BE CONCEALED IN WALL SPACE, CEILING SPACE OR UNDER FLOOR, NO EXPOSED CONDUITS PERMITTED. COMPLETE SYSTEM SHALL BE GROUNDED PER N.E.0 ARTICLE 250. O FINAL CONECTIONS TO ALL DIRECT CONNECTED KITCHEN EQUIPMENT SHALL BE WITH U.L. APPROVED LIQUIDTIGHT CONDUIT. PROVIDE WITH GROUND WIRE SIZED PER N.E.C. ARTICLE 250 (2008). O E.C. SHALL PROVIDE AND INSTALL ELECTRICAL DEVICES AND WIRING TO COMPLY WITH N.F.P.A. 96.7-3.1.3 FOR POWER SHUTOFF ON ALL ELECTRICAL EQUIPMENT UNDER OVEN HOOD. VERIFY INSTALLATION AND OPERATION REQUIREMENTS WITH EXTINGUISHING SYSTEM SUPPLIER. PROVIDE POWER IF REQUIRED BY LOCAL CODE. ()ALL BRANCH CIRCUIT WIRE SIZE SHALL BE MINIMUM #12 AWG COPPER. PULL EQUIPMENT GROUND IN ALL RACEWAYS, PER N.E.C. . ELECTRICAL CONTRACTOR SHALL PROVIDE PROPER NUMBER AND SIZE CONDUCTOR PER N.E.C.. IR ELECTRICAL CONTRACTOR SHALL PROVIDE AT EACH"; PANELBOARD A TYPED CIRCUIT DIRECTORY WITH PROTEC IVELASTIC SLEEVE. �r 'IRE ;'1,; fir'\. -.��/ `v'"-�✓"`v''v'-�.r"v'"�✓�✓'�.r PANELBOARD .. i TYPED CIRCUIT U " DI RE - ORY O FIELD COORDINATE ALL LIGHTING SWITCH LOCATIONS WITH OWNER AND INTERIOR DESIGNER. h ELECTRICAL LEGEND RECESSED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION. UPPER CASE LETTER INDICATES FIXTURE TYPE, TYPICAL FOR ALL LIGHTING FIXTURES. ® RECESSED LIGHTING FIXTURE, SAME AS ABOVE EXCEPT WITH EMERGENCY BALLAST. ® FLUORESCENT LIGHTING FIXTURE - SURFACE OR PENDANT MOUNTED. I-0 STRIP FLUORESCENT LIGHTING FIXTURE. PL FLUORESCENT, LED, INCANDESCENT' OR H.I.D. LIGHTING FIXTURE - RECESSED. 4 PL FLUORESCENT, LED, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - SAME AS ABOVE MOTOR, FAN, PUMP OR AIR CONDITIONING UNIT CONNECTION PER NEC. LIGHTING AND/OR POWER PANELBOARD. WIRING IN CONDUIT, RUN CONCEALED 1N SLAB OR UNDERGROUND. WIRING IN CONDUIT, RUN CONCEALED ABOVE CEILING OR IN WALLS. HOMERUN TO PANELBOARD - NUMBER OF ARROWS DENOTES QUANTITY OF CIRCUITS. CROSSMARKS INDICATE QUANTITY OF NO. 12 CONDUCTORS. RUNS VOID OF CROSSMARKS ARE 1/2 INCH CONDUIT, 3 NO. 12, U.N.O. DO NOT COMBINE HOMERUNS EXCEPT AS SPECIFICALLY INDICATED ON THE PLAN. E3JAo DISCONNECT SWITCH, "3 60/40" DENOTES 3 POLE, 60 AMP, 40 AMP FUSES. 40 DENOTES WEATHERPROOF WHILE -IN -USE,- MOUNT RECEPTACLE VERTICALLY AND PROVIDE 1 } QQ--I PL FLUORESCENT, H.I.D. OR INCANDESCENT LIGHTING FIXTURE -SURFACE OR WP TAYMAC 71202 COVERPLATE, FOR SWITCHES PROVIDE TAYMAC 40110 COVERPLATE. i WALL MOUNTED. U.N.O. UNLESS NOTED OTHERWISE. PENDANT MOUNTED LIGHTING FIXTURE. AFF ABOVE FINISHED FLOOR. Y PL FLUORESCENT, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - FLOOD LIGHT. AC DENOTES MOUNTED ABOVE COUNTER HEIGHT, PENDANT MOUNTED PADDLE FAN COMPLETE WITH PENDANT &CEILING MOUNTED. C DENOTES. MOUNTED RECCESSED IN CEILING SOFFIT. CANOPY -MOUNT AS DIRECTED BY INTERIOR DESIGNER/ARCHITECT, U.N.O. GG GREEN GROUND' CONDUCTOR. ® EXIT LIGHT - PROVIDE ARROWS AS INDICATED, SHADING DENOTES FACE OPERATION. DO NOT SWITCH. E.C. EMPTY CONDUIT WITH PULL WIRE / CORD. EMERGENCY LIGHTING FIXTURE- DO NOT SWITCH. IN -GROUND COMPOSITE HAND HOLE WITH TRAFFIC RATED COVER. SIZE AS REQUIRED BY CODE $ TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL C1 CEILING MOUNTED J-BOX WITH BLANK COVER PLATE FOR CAMERA. INSTALL NO. HBL12211 WITH NO. P1 COVERPLATE - 46" MOUNTING HEIGHT, U.N.O. 3/4" CONDUIT WITH PULLSTRING TO ACCESSIBLE CEILING LOCATION. $2 TOGGLE SWITCH - TWO POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL SEMI -FLUSH MOUNTED MANUAL FIRE ALARM PULL STATION,' 46 INCH MOUNTING HEIGHT. NO. HBL12221 WITH NO. P1 COVERPLATE - 46" MOUNTING HEIGHT, U.N.O. SEMI -FLUSH MOUNTED FIRE ALARM AUDIO/VISUAL WARNING DEVICE, 80 INCH MOUNTING - $� TOGGLE SWITCH - SINGLE POLE, 20 AMP, 120/277V, MOTOR RATED, GROUNDING HEIGHT FROM FLOOR TO BOTTOM OF DEVICE. TYPE, MOUNT AT EQUIPMENT HOUSING. 0- DUCT MOUNTED SMOKE DETECTOR, MOUNTED IN A/C DUCT. SEE MECHANICAL $3 TOGGLE SWITCH - THREE-WAY QUIET TYPE, 20 AMP, 120/277 VOLT, HUBBELL DRAWING FOR MOUNTING LOCATION AND QUANTITY. NO. HBL12231 WITH NO. P1 COVERPLATE, 46" MOUNTING HEIGHT, U.N.O. ® AIR CONDITIONING/HEAT PUMP SHUT -DOWN RELAY. $D DIMMER SWITCH - LUTRON NOVA SERIES, 2000 WATTS, SELECT FOR., LOAD/BALLAST/DRIVER TYPE. 46" MOUNTING HEIGHT, U.N.O. Q CEILING MOUNTED SMOKE DETECTOR. $F FAN SPEED CONTROL SWITCH - LUTRON NFS-12E, 12 AMPS. 46" MOUNTING HEIGHT, HQ CEILING MOUNTED HEAT DETECTOR, U.N.O. FACP FIRE ALARM CONTROL PANEL ® OCCUPANCY SENSOR WALL SWITCH - WATTSTOPPER FAAP FIRE ALARM ANNUCIATOR PANEL \� #DW-100-1. 46" MOUNTING HEIGHT, U.N.O. QM CEILING MOUNTED LOW VOLTAGE MOTION SENSOR-WATTSTOPPER DT-305. PROVIDE POWER PACKS AS REQUIRED. QW WALL MOUNTED OCCUPANCY SENSOR-WATTSTOPPER DT-205. MOUNTED AT 10' A.F.F. PROVIDE POWER PACKS AS REQUIRED, DUPLEX RECEPTACLE - 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL 'NO. 53521 WITH NO. P8 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O. ,DUPLEX RECEPTACLE - SAME AS ABOVE EXCEPT MOUNTED ABOVE COUNTER, 2"MOUNTING HEIGHT, U.N.O. DOUBLE DUPLEX RECEPTACLES - (2) TWO 20 AMP 120 VOLT, 3 WIRE GROUNDING, HUBBELL NO. 53521 WITH NO. P82 COVERPLATE, 16" MOUNTING HEIGHT, U.N.O. DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20 AMP, 120 VOLT, WIRE GROUNDING. HUBBELL NO. GFTR201 WITH NO. NPJ261 COVERPLATE, 6" MOUNTING HEIGHT, U.N.O. EXTERIOR LOCATIONS SHALL BE MOUNTED AT 18" A.F.F. BE -SAME AS ABOVE EXCEPT FLOOR MOUNTED IN TOMBSTONE OUBLE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20 AMP, 120 VOLT, - WIRE GROUNDING. (2) HUBBELL N0. GFTR201 WITH N0. NPJ2621 COVERPLATE, 6" MOUNTING HEIGHT, U.N.O. EXTERIOR LOCATIONS SHALL BE MOUNTED 18" A.F.F. ® ECIAL PURPOSE RECEPTACLE COMPLETE WITH COVERPLATE. SEE FLOOR PLAN R COMPLETE CONFIGURATION. ATA/TELEPHONE OUTLET - 4 INCH SQUARE JUNCTION BOX WITH 1-GANG EXTENSION RING, BLANK COVERPLATE - 18" MOUNTING HEIGHT, U.N.O. PROVIDE 1" CONDUIT TO ACCESSIBLE CEILING SPACE. - J' NCTION BOX SIZE PER NEC. �jMISTING TELEPHONE/DATA OUTLET (\ r OUTLET - 4 INCH SQUARE JUNCTION BOX WITH 1-GANG E TENSION RING AND BLANK COVER PLATE - 18" MOUNTING HEIGHT, U.N.O. INSTALL I C. TO CEILING SPACE. L,.,. -r_ 1.­ ��a� _�-���_,,, US MO MOUNTED FLOOR BOX WITH (1) DUPLEX RECEPTACLE, "(1) DATA PLATE, AND (1) AV PLATE. W REMOLD TYPE EFB6S WITH EFB61 OCTBK COVER. INSTALL (1) %" CONDUIT WITH PULLSTRING FROM AV L CATION TO CEILING, (1) %" CONDUIT WITH PULLSTRING FROM TEL/DATA LOCATION TO CEILING, AND ( ) 3/4" CONDUIT WITH POWER CABLES FOR POWER. u �copy ST. L CIE COUNTY BUILDING. DIVISION REVIEWED FOR C �p AN REVIEWED BYesZ /ii DATE _ 41, !2 —14 :PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE T� SHAFFER. jV��) ENUIN FENINU UNCUR LLC oases � eim sw soz � 09j B 6R1 F%rM"j99 6L1 C Mfl bM 65 J BRYANSHAFFER ENSE#58168 1t%AN ,re1�10j, . ... 'YS1 :A� 0 A\ m M rz Z 0 Q o z C o I--1 o N a o o � z 4 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF W14AM DESIGN GROUP, AND SHALL REMAIN THOR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE,FLORMA 32256 (904), 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lie. Nos.` AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E191 'AL 1-- milt, "'llown -Moor I i II 0 I zh �� � Lu�l.� O C4) � ® o 0 0 0 0 0 0 -- ® ��Ir� vZ r mlo lr o 0 0 0 0 0 0 II ® rt 1 o -o o -o rr �ol� I I ��� ul II II II II ®�- - Q.- p , , , ®L a_i® 0,-. ® (> `iiii o I�L.=J r-I -r1 �1 r1 1 o `off o 0 o I �Ir II ® �� o® o p o® O 41 J L J �® II II II II II II II IG%/ o o O o ® ]y I o p -LA -- _ ,J - -LJ LJ �� (� �- ® ,® O, a r=� F�sO® — �® L Cam'=�'Z��=�'=�'C�j �O L J g po _ o 1p r =l I`1� LJ__--n LJ 1 e II III it C� C� C� .-I� 4 �� I ,L® I I �p ® O O p - 1 o o yl®�� �° �O ® ' r1p r1 l _ qj 11 OoJ o 0 o p oo ]I o II II II II . - -- J o r/ +1 i o ® O 1 m -� - - /El III r L_J // o zl tl �� CJ=J=JZJ=J� O LJ L.J ® p I -_ n p 11 II II 1I - __I 10 � p � ® n 1 ri ® L LJ r10 5) o0 op -®y � - ,_,® ®,-� II (� l' ' _ / ® r�r ILA ® y C i U i- ID 11 x �® L _IL JL J r 1p ` - II II/' o 0 0 0 - 0 0 �o I r 1LJ C� C L I J p L J - �® r® -YO r-O --P r®I o p'� ®_ 7— ® 1® / 4 I� ® rT-7rT- n J LO 01 L•O OJ ^ ^ �" II 01 II p II II : p Ir p p - -~ -- -�- -- — - - -- - ---�-� - - - -- -/ Ill r-,II 11 II II; CO) �i / ��® Tip i I ILJJ L4/� (o) o' / - vCo) i — -� �. �ld. Ar `0 0- - np ®Co) °CO,`I C I N ELECTRICAL DEMO PLAN —LIGHTING SCALE: 1/8"= 1'-0"' n0 ,�® no I II NOTES: c J+ ::3 c U � 1) ® REFERENCE NOTE ON DRAWING 1. EXISTING LIGHTING FIXTURES, CIRCUITING ANDIn CONTROLS TO REMAIN. DEMOLITION NOTES: ES: p 2. EXISTING LIGHTING FIXTURES TO BE REMOVED. 1. THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WITHOUT PRIOR I C +0�:) � C;R_ C _ SCHEDULING OF SUCH OUTAGES WITH THE OWNER'S REPRESENTATIVE. ® U U ® u 3. EXISTING DEVICE TO BE REMOVED. 2. THE CONTRACTOR SHALLNOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN — 4. EXISTING LIGHTING FIXTURE TO BE REPLACED. ASSOCIATION WITH THE WORK. ALL SALVAGEABLE ITEMS SHALL BE THE OWNER'S PROPERTY AT HIS OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE ® ® I 5. EXISTING SWITCHING TO BE REPLACED. CONTRACTOR AND SHALL BE REMOVED FROM I TH E SITE. n6 nO I I: 6. MAINTAIN CIRCUITS TO ALL EXISTING RTU'S, 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO I' C C I AHU'S, AND CONDENSERS. EXISTING SYSTEMS AND SHALL UPON COMPLETION, DELIVER "AS -BUILT" DRAWINGS TO THE OWNER, INDICATING ANY SUCH CHANGES. 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS SHALL BE CAPPED AT POINT OF CONCEALMENT. 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE REMOVED BY THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN EXISTING CIRCUITRY TO ALL REMAINING DEVICES AND FIXTURES. FOR EACH DEVICE OR FIXTURE REMOVED AT l ®(0) O)® I I THE END OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM LAST REMAINING DEVICE, FOR EACH DEVICE OR FIXTUR REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALL REMOVE ® -J WIRING FROM FIRST DEVICE OR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE NEW On CO �j F Z z O a o Lu W w I Lz 0 0 I z 4 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SRE FOR WHICH IT PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. ail i +_4 ct v O � U W g:� BASHAM & ]LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE WIRING, SIZED THE SAME AS EXISTING,' SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES 7645 GATE PARKWAY, #201 OR FIXTURES. JACKSONVILLE, FLORIDA 32256 C(904) 731-2323 FAX (904) 731-2699 FILE 111 6. CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSEDft Website: www:bashamlucas.com SYSTEMS MEET CURRENT CODES AND SPECIFICATIONS. REMOVE ALL UNUSED SURFACE MOUNTED Lic. Nos.: AA26000586 CONDUIT. UNUSED CONDUITSU' STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. 7. EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL BE RECONNECTED TO PANELS. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THAT HAS TO BE DISCONNECTED FOR CONSTRUCTION SHALL BE REINSTALLED. 8. ELECTRICAL DRAWINGS DO NOT INDI CATE ALL THE EXISTING INSTALLATIONS. 9. AL X L EXISTING SWITCHES, RE CEPTACLES, LIGHTIN G FIXTURES TELEPHONE OUTLE TS, ETC THAT DO NOT INTERFERE WITH RENOVATIONS SHALL REMAIN. 10. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDITIONS. ALL THE NECESSARY REROUTING,RELOCATIN G AND OR REMOVAL OF EXISTING EQUIPMENT, UIPMENT WIRING ETC. SHALL BE INCLUDED IN THE SCOPEI VARIATION T OF THIS WORK. ANY VARI ON FROM EXISTING CONDITIONS ONS SHALL BE ------ ---- INCLUDED UNDER THIS CONTRACT. SHAFFER FIVNII IIIV IROVP•LLC uossaw.eiw,sADZ J nip. aazrzrzaPMIawlYdaaezA ix 1.w1:89J9Am ' - CeMA MPutlwAiaHonp'. 3BM6 J. BRYAN SHAFFE .E. LICENSE # 58168 ♦♦♦��\\\ N ♦ 1 E ..c � d , �0, ST :*^ - 1 DRAWN BY MEM CHECKED BY JDS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E_�j2.1 I'Il II I I \\\\\ � _ - EXI INGO \� -- S RD FH�p ff(D Q � p Oy _ —lF }}® FH�O ®H PAN:I FAC / ® EXISTING / / \ � �; ,•., ,, `` J � i� � � — � — TELE. BOARD G /I, I 96 ®�9 x = ® EXISTING t t I t t t N I +t t t ❑ C_ Ll OC gip. F,O -- CJ C C'F�F�CISTING I R ff H N' ff ff ff ff ffl ff _ rr SECURITY Y�ANEL / — / ---� �r� SERVER RACK 8t�t® ` 96 Imo^ <� fl v O� \ ®EXISTING EXISTI �p O PANELS pit OINt 1 �? / ^ �: \ O BA & BB SYSTE .w O .. I it , i IuI di I�� L 5 - ) � - II I ,, 'J p EXISTING ATT KWH OO l f ®EXISTING ~,. � � J `�� top I I III BOXMIN L -- I L � c — --- r II / // ilIp II L J Zx/ o p L.It o� - Al ®EXI TING PL EXISTING—►{ WP p TRNSFO ER PANEL DPA T i E G O / ( O O / i 96 \ Y — — / i p[TV OEXISTING —�1 �� L� it L AL _J J / Col Cl Cl 96 FAAP IX W / it f` f J _.._..� I� ® `�� ® O _( EXISTING �O t ; 90 FH O 00 Od IV — t —f 0 S' P ELS `\' t t LFJ t tJILT L JIZ EXISTIN \ Y ~ PANEL IS 177-1 I I _I .80 / I r® ® / ELECTRICAL DEMO PLAN -POWER € - ,y ' GI AND SYSTEMS N �1 SCALE: 1 /8"= 1'-0" I dm I I I, NOTES I_ III ® REFERENCE NOTE' ON DRAWING 'I 1. EXISTING DEVICE TO BE REMOVED. DEMOLITION NOTES; _ I �® ®— 2. EXISTING DEVICE TO REMAIN. 1 THERE SHALL A LOFOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WITHOUT PRIOR OUTAGES WITH THE OWNER'S REPRESENTATIVE. ®_ 3. EXISTING DEVICE TO BE REPLACED. 2. THE CONTRACTOR SHALN6 TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN L 4. EXISTING DEVICE TO BE RELOCATED ASSOCIATION WITH THE WORK. SALVAGEABLE ITEMS SHALL BE THE OWNER'S PROPERTY AT HIS OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE I j 5. EXISTING PANEL TO REMAIN. CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. 6. EXISTING PANEL TO. BE REPLACED. 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO EXISTING SYSTEMS AND SHALL UPON COMPLETION, DELIVER -AS—BUILT" DRAWINGS TO THE OWNER, 7. EXISTING TRANSFORMER TO BE REPLACED BY INDICATING ANY SUCH CHANGES. FPL IF REQUIRED DUE TO BUILDING LOAD. 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF I I CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS SHALL BE CAPPED AT POINT OF CONCEALMENT. W C_F�O OLFJ WPp 31 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE REMOVED BY THE EXISTING ® ® T 6 ( CIRCUITRY TO ALL REMAINING CONTRACTOR. AND FIXO UR SAL FOR EACH DEVICEEOR f XTURENREMOVED AT ' THE END OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM LAST REMAINING DEVICE, FOR EACH DEVICE OR FIXTURE REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALL REMOVE ® ® I WIRING FROM FIRST DEVICE IOR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE. NEW 6fi Q9 WIRING, SIZED THE SAME AS EXISTING, SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES ®6- ®N` I ( ? OR FIXTURES. 96 [ \. 6 CONTRACTOR MAY REUSE NCONDUIT BPROVIDING E REUSED SYS EMSMEETCURRENT COD SANDSPECIFCATIONS. REMOVE AILLUNU UNUSED SURFACE MOUNTED 04 00 G 04 /� � I CONDUIT. UNUSED CONDUITS, STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. \ \ t t t F7 t F? 7. EXISTING RECONNECTED TO EQUIPMENT NOT OT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL S. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THAT HAS TO BE DISCONNECTED OR CONSTRUCTION SHALL BE REINSTALLED. 8. TRICAL DRAWINGS DO N OT INDICATE ALL THE EXISTING INSTALLATIONS. 9. ALLEXISTINGSWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT INTERFERE WITH RENOVATIONS SHALL REMAIN. 10. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDIT IONS. ALL THE NECESSARY REROUTING, RELOCATING AND/OR REMOVAL OF EXISTING EQUIPMENT, WIRING ETC. SHALL BE INCLUDED IN THE SCOPE OF THIS WORK. ANY VARIATION FROM EXISTING CONDITIONS SHALL BE INCLUDED UNDER THIS CONTR ACT. I — / SH. OnAll ") J. BRYA_N SHAFF _ :lit 1 E CPOUF. LLC ro_ain aoz �•a �m �IBMIR3B%R].... .s..1 NSE # 58168 y *• No,J6Tl1 l�*. 7. l w STATE ..R...• I �nl nll ni I II m m z Z Q a z 0 o -- coo V) V W Q � O I z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH R IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. � w CIO Q ct UUU^L/,n a Vt ;--I a mac) � 's► � � w U BASHAM & LUCAS DESIGN GROUP, INC. PLANNTNG-ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONWLLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JD S DATE 03-26-14 JOB NO. 13-40 SHEET NO. El 2 0 2 ��® WOOV N PARTIAL ELECTRICAL LIGHTING PLAN SCALE: 1 /8"= l'-O" PLAN NOTES ® REFERENCE NOTE ON DRAWING 1. PROVIDE ADDITIONAL WIRES FOR 0-10V DIMMING. 2. CONNECT EXIT SIGNS, NIGHT LIGHTS, AND EMERGENCY BALLASTS AHEAD OF ANY SWITCHING. 3. FIXTURE TO BE PROVIDED BY OTHERS AND INSTALLED BY CONTRACTOR. 4. ROUTE THROUGH LIGHTING CONTACTOR. 5. PROVIDE AS PART OF GUEST PAVILLION ALTERNATE. 6. ROUTE ALL ROOM LIGHTING CIRCUITS THROUGH POWER PACKS PRIOR TO SWITCHES. 7. CONNECT TO EXISTING ROOM LIGHTING CIRCUIT WITH (3)#12, 1 /2" C. DO NOT EXCEED 1900 WATTS ON CIRCUIT. 8. CONNECT TO COOLER/FREEZER LIGHTING. 9 EXISTING LIGHT FIXTURE TO BE REPLACED CONNECTTO EXISTING CIRCUIT.. 10. CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS UNLESS NOTED OTHERWISE. NE4Y^I ED gETROFIT., IN,XISJJNG �ITURE /\` 1'1,ltiINSTA�L 12. EXISTING FAN AND CIRCUITING TO REMAIN. 13 RELOCATE AND REPLACE EXISTING LIGHTING CONTROLS WITH NEW. FIELD VERIFY REQUIREMENTS. 14. SEE ARCHITECTURAL/INTERIOR DESIGN ELEVATIONS FOR EXACT MOUNTING HEIGHTS. 15. AS PART OF PAVILION ALTERNATE PROVIDE MOTION SENSORS AND POWER PACKS TO CONTROL LIGHTING SIMILAR TO l MEMBER BAR. SEE SHEET E3.7. 16. INSTALL LENS WITH SMOOTH SIDE DOWN IN KITCHEN AREA. 17. SEE INTERIOR DESIGN DRAWINGS FOR DIMENSIONED LOCATIONS OF RECEPTACLES AND LOW VOLTAGE BOXES. 1!\1 L1�. ENOI 4NEEtINO t Ot F, LLC ,xaese, w.na,sn eox on�oa�zaeaea, rx iew�axaea ainemmm�.. xezas J. BRVAN LICENSE C 58168 m m zZ 0 Qa it o ~ N 0 to FBI W I a O in I O a Z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY UMBED TO SUCH USE. BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY ,TB S DATE 03-26-14 JOB NO. 13-40 SHEET NO. E301 �0 SlONPL EnnuLEEE I I u w _ -- Z _ H H H H �� H \ t a H H - v IL ( r - T T T T T T FIXTURE IN GO_ j X1 A — QO OO QO OO M O ET C H L adJ S-I r1 —1 r1 ® TO -\ RI(V;ATE DINING S1 S1 T S2 S ® E S2 T M �.L \_\ O O A, �� A OO G OH 12 M — T C�'Z�� ��Z�'77-1 C 1 LOB Y M ® ® ® I® ® 1(9 �iz1 714 % -_T ®TYP. FOR CT4`EFS2' QOT S1 S1 IXTURE IN GO \ TO M a S1 S1 O = -- S2 S2 ON L ;0) O ®E O TQO TO TO X1 S3 1 / ® H O O { I 7 ®® M® � T Tp Tp l M \ O l l _ S1 S1 S2 2 Qp S1 PRO TO \ E 0 NL O E - T122 I \ D1 D1 T TO M A E TI Ud M S1 S1 B S T Z�C LES O $ O r 6 1 T OS2 S2 OS2 O - l 113 ® ®Q �E Ho® T 01%P2A-10 O .� MT T r� P 8 T T T®® OD3 / 91 �\ P3)9=tt- D3E m H D3E D3 D3 D3E QD3 HALT D3 D3E D3 X1 X 0 0 0 140 o MEM R �\ / SEE DWG M NL - NL D3 EN P3B — P3B-4 E3.1 FOR _ O CONTINUATION AH H OF� R M MBER m o 3 CIRCUITS'1 D3 D3 VES 6G L 11 D3E o H O O O 20 �� NL � NL I� P3 18 11 V u ,r. ea ICI - CE i O D1 NL N PARTIAL ELECTRICAL LIGHTING PLAN ; D60 60 D E 3E C DIE P3 .fir L DIE �� M �, D6 D6O pH SCALE: 1/8"= 1'-O„ P3B-2 -' E �T - r i ®`� M --T 1 m C ® y;> A D p DsoD� p PLAN NOTES P3B-3� 1 P3B — — N 1 ---.- -- - -- ® REFERENCE NOTE ON DRAWING A q\ O ® D6 D60 60 S FOR 0-10V DIMMING. l ..Ll __.. ® L® A D6.. 1. PROVIDE ADDITIONAL WIRE O 7 O 7 D7E D7 D60 OH 2. CONNECT EXIT SIGNS, NIGHT LIGHTS AND EMERGENCY SEE DWG MEMBER C C ® D6 D6 BALLASTS AHEAD OF ANY SWITCHING. E3.1 FOR TERRACE. o p CONTINUATION m D7 D7 P3B ® 3. CONNECT TO EXISTING AREA LIGHTING CIRCUIT WITH - OF CIRCUITS O O- — (3)#12, 1/2" C. DO NOT EXCEED 1900 WATTS ON P38 g CIRCUIT. I I AE KI'i O O 1D7 1D7E D7 7 D7 D7 D D7 B M OD6 D60 OH 4. ROUTE THROUGH LIGHTING CONTACTOR. O D -21® NL 5. REPLACE EXISTING LIGHT', FIXTURE. 7 p `�, t9 D6E D O 0 O p 6 6. EXISTING LIGHTING TO REMAIN. D �? D rD6 O 6 D6 O O 7. FIXTURE TO BE PROVIDED BY OTHERS AND INSTALLED BY 3B l ; ps D6 CONTRACTOR. 6 H Ld z w p 37� �� X D6 J / D6 0 8. ROUTE ALL ROOM LIGHTING CIRCUITS THROUGH POWER U / J \ lX2 OD6 D6 D6 O PACKS PRIOR TO SWITCHES. J .J I- 9. INSTALL FIXTURE AT SOFFIT. SEE ARCHITECTURAL O 6E I O ELEVATIONS/SECTIONS. H- D6E O O 10. CONNECT TO LIGHTED MIRROR. D D6 l 11. SEE ARCHITECTURAL/INTERIOR DESIGN ELEVATIONS FOR EXACT MOUNTING HEIGHT. H 1 j H 12. INSTALL LENS WITH SMOOTH SIDE DOWN IN KITCHEN AREA. 6 D6 l COVE LIGHTS .13. EXISTING TRACK TO REMAIN. REPLACE EXISTING TRACK OD MBER D60 TYPE 'W' AROUND LIGHTING HEADS WITH NEW WHITE 1000 LUMEN, 3000K, BAR PERIMETER OF BAR LED TRACK HEADS. HEADS SHALL ALTERNATE BETWEEN 5 61 125 AREA (TYP)• S SPOT AND NARROW FLOOD DISTRIBUTION. 14. CONNECT TO EXISTING LIGHTING CIRCUIT AN w6E \ D6 0 i D CONTROLS. � ■■ '� 6 � 5 D6 { 15INSTALL NEW LED RETROFIT IN EXISTING FIXTURE COPY T / r 16 ALL EXISTING ROOM SWITCHING TO REMAIN H M rr r r - H/ SHAFFER _ [NCINEE0.INN NROUP.L[C soles Jo. 9l a wm sox JeSeonuNle FLexFA 2M PHI�)x=.Jsx1. %1 IxleJ4R3m I Cwtlfu I ielkn0..:xBMs J. BRYAN SHAFFE .E. CENSE # 68168 HA -- _ .* 71 • O N P7- EE m m con zzz a z x o 1--1 V VI W I� 00 I I z 4 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BSHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. 113A S 11 M �� LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamiucas.com Lie. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E "ON •z w = �. o T _� TV I� 1 p _ �3A�21 P -21 P3A 1 P -21 P3A- 1 --- � a 44 -1 "O72W " 2 n rai M n n I 1 PRIVATE m) HOT V A-21 DINING"rN Ciz - L Jt H , RESTAURANT' i � I C ♦c \, C E ® % I 1 n 42 ll EXI - 2 1 L � KWH , EXI T NG i T FORMER �\ EXISTI� [TV 2�A1ID E7LES \, ff ` PA " 113 \ \ J © 1 1 G- 9 3A 2�3�- 3A� 1'- 3A 23 -2 HALL FFALL © _ r4z f H 153 J P3A-20 ACP WP H PA P3A 2 _ III TI P1 P3C-3 MENS O UTIL P3C �� OItE � f�4� 96 o I — -f1 t ` � �- ma® LL 149 I o \JJ MDP�41 3A-�0 Q WP TV 9 6" 6 IL �« 144 1., ^ E C v P3 -2 JJ60 �]L 30E0 1 3 �`� P3C H L ( A WO E._ 1 P3A-4 P3A-4 .` ; ; r C L.AV 1 rM S 150 3A 1 -8 147 C WOM z, H L_-� E { MEETING P1f ER L — _. F P3A�4 ROOM P_4 ® 1 3 3C 18� 14 T , 155 -18 / -' = A 0 P C=CO P -10 L— � P3A- L h 18" y, 18" mspL Fll F O L- ® ® VC L _T L \ O N 1\ A-24 _ I F i IATRON ANTI ROOM I TERRACE c c P3A- Tin 1 WP H HF ® ® OS ®< PM-24 P3A-24 % ® _ P3A-41 \IWA N PARTIAL ELECTRICAL POWER ®� P3A-39 "u\ �- AND SYSTEMS PLAN TV w N96" 96" J SCALE: 1 /8"= 1'-ON ©® ® ® ®❑F , a NOTES: c� C P3A-=3' - AWING I REFERENCE NOTE ON DR 1. ALL ELECTRICAL TO BAR SHALL BE ROUTED \ UNDER FLOOR. 2, EXISTING DEVICE TO REMAIN. ©' PAVILION RECEPTACLE AND COVER 3. REPLACE EXISTING 157 PLATE, CONNECT TO EXISTING CIRCUIT.; 4. CONNECT TO EXISTING RECEPTACLE CIRCUIT WITH I L P3A 9 RECE TACLES P12, ER"CIRCUO NOT EXCEED 8 cppy 5. CUT AND PATCH EXISTING FLOOR TO INSTALL FLOOR BOX AND ASSOCIATED CONDUIT /1 6. SEE ARCHITECTURAL/INTERIOR DESIGN `—I �~ } ELEVATIONS FOR EXACT MOUNTING HEIGHTS. {) 1 1 P3A-39 \ ~ 7. PROVIDE POWER TO FIREPLACE IGNITER. — -- 8. POWER TO HAND DRYER. COORDINATE EXACT - --- MOUNTING HEIGHT WITH DRYER. • r SHFFEPL - 1 fiENOENEERINC YROYR,LLC l 120583m JWa BIWSuIb� 9. SEE INTERIOR DESIGN DRAWINGS FOR \ 1 JarMxnNb ilffi22]wrov eelbW mm DIMENSIONED LOCATIONS OF RECEPTACLES AND Pnl«1��2, .aao l� 22 LOW. VOLTAGE. BOXES. / rs J. BRVAN SHAFFE ICENSE#58168 I .. I 9 I wilt 11111" AN S .S ORIO•. �� A L EN L I tnRnEM� I II mU) D] zZ z Q a z 0 I --I N N W Lu a 0 oI O QZ THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. W� ct II��11 ct W �H r� W ^O� BOASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.,com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E401 Ld C) rP2A 19 P2P OFFICE FAkP 1 -PRIVATE( P2A-rDINING TV / P2A-19 > LOBBY 114 TV T D D MANET�ANILI i ® (aa 118 t L \� E ® \ EXISTING �, =`\` 120 ® TELEPHONE OARD ' H . --- ®— EXISTING EC r._ EL EL P2A-13 , P GOLF c L, SOUND S P2A-13 3`�.-_..... SYSTEM s®® �j 8-25� ASSIST r P2A-13 1� 6 PRO H 1 P2A-13 5 i P3A-29 MEMBER© j VC 14 0 �- P3A-29 ❑ ENTRY 123 Pac-s S R MEMBER 29 3 P3A-25 z VESTIBUL ELEP 96" BOARD O'"h 135 II q MEN — P3A-33 P3 " ❑ o TOILE �C P3A-2 HANDHOLE FOR FIBER - W. _ O 4 129 A-29 P3A-1 ❑H ��SEE TEL/DAT/TV SINGLE E ] WH ❑ DIAGRAM. p - P3C- 3 El S W E b DISPLAY LASEf IDSP18Y59 LE P3C- - P3A vo 138 J 1 13 0 P 3f � P3 C- _ , ❑ P3A-28 - GALLERY L® — a c e EN �MEl' L c a 1 P3C- 1 P3C- L�:h�.- C L V L H 18" P3A-1 P3A-1 )M ® OMENS 1 15 LO K R P3A-11 ICK ❑ OCKER : L 1 ® P3C H A- 15^ iA P3A 9 ) -23 L - 1`� P3C- P3C P'„ 18" " 18M P3C-9 l DISPL Y CASESEl r F VESTIBUL -7 3 -5 _ O 'o H © P3A- = 131 M N F W P WP ` ) C _r A-37 -37 P3A-37 © -9 - P3A-1 3C 1 mIn m zZz C) g z w o A N V) a o � I O 4 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICARON THEREOF IS EXPRESSLY LIMITED TO SUCH USE. a Cr C4� O a4-4 1 V1 W I a" Ill 1--I o MEMBER Pdbm 3c-1 Ll 0 TERRACE cc P3A-3 P3A-37 1 • 15 � '❑ I O lC� EE ENLARGE 0 W TCHEN P W H P A-2 i ❑ ❑ ® ---- - -----. PA RTIAL L ELECT RICAL POWER I, W --- P4B-26 l AND SYSTEMS PLAN 1 z P3C-7 SCALE: 1 /8"= 1'-O" BASHAM U vC P3A-3 ! 3A-3 QQ'' T L TV A g NOTES CJ�C� C A S i 12 ® REFERENCE NOTE ON DRAWING DESIGN GROUP, INC. P4J3 1. ALL ELECTRICAL TO BAR SHALL BE ROUTED UNDER FLOOR. PLANNING •AxcxlTEcruaa -LANDSCAPE 2: EXISTING DEVICE TO REMAIN. 7645 GATE PARKWAY, #201 4 " i O ® JACICSONVILLE, FLORIDA' 32256 3. REPLACE EXISTING RECEPTACLE AND COVER PLATE. (904) 731-2323 FAX (904) 731-2699 r P B- CONNECT TO EXISTING CIRCUIT. WebsLic. Nos.: AA 26000 as.com M B E R I LiG: Nos.: AA26000586 4. CONNECT TO EXISTING RECEPTACLE CIRCUIT WITH (3)#12, BAR P 26 1/2" C. DO NOT EXCEED 8 RECEPTACLES PER CIRCUIT. 125 2 3 5. FEED COUNTER UNDER FLOOR. CUT AND PATCH EXISTING © P48-35 P4B-25 SLAB AS REQUIRED. 6. CUT AND PATCH EXISTING IFLOOR TO INSTALL FLOOR BOX / AND ASSOCIATED CONDUIT.' 7: ELECTRICAL TO SERVICE STATION TO BE ROUTED UNDER 4B-28 FLOOR. $; PROVIDE (5) RECEPTACLES AND N OUTLET LOCATIONS AT ' HEIGHTS AS INDICATEDON INTERIOR DESIGN ELEVATIONS. 9. PROVIDE POWER TO FIREPLACE IGNITER: SHAFFEIZ ".m ENCINEENINN CNOVE.LLC 10. POWER TO HAND DRYER. COORDINATE EXACT MOUNTING3 ID663nJn.Pv i l" W mm HEIGHT WITH DRYER. - IB It30J811FX1 Bi 9 v CxtlOmbW mRe,lonp 6d5 J. BRYAN SHAFFER, . LICEN # 58158 E. c S fi•. F i� w Ny�'S����" DRAWN BY MEM CHECKED BY JB S DATE 03-26-14 JOB NO. 13-40 SHEET NO. E492 y •RTATP. w sommooloommomma. c.. pa. ;ek\6.COR1O,. \ �� 4�SSIONAC.EG 1�nn�n�� I j� N Lt�P f T I\ 9 r. l 44' m 3061 lh A 13 Pi B <<I 1 C I Jl 3 _4 30 WP W > 3�WP 3 o P 0 1r T L— 3 TC I� V P1A-20 l 1848 I<I-- ( _J` 1 L__ J 1051 _ J a P /^�\ DPA ..� (� T I� EXISTING TRANSFORMER / — t A 20 Ir —23 II / 1- 04 03 I _ 2, ; F. - o o PANEL M<r - Pic ilir IU m n,�ui� ENLARGED KITCHEN (1271 POWER AND SYSTEMS PLAN s-- PLAN NOTES '- - — — -' pas O SCALE: 1 /4'r= 1'-0'r ® REFERENCE NOTE ON DRAWING 1. COORDINATE KITCHEN ELECTRICAL REQUIREMENTS AND MOUNTING HEIGHTS WITH FINAL KITCHEN EQUIPMENT SELECTIONS. 2. CIRCUITS FOR EQUIPMENT UNDER HOOD ARE PROVIDED WITH SHUNT TRIP BREAKERS. CONNECT SHUNT TRIP TO HOOD FIRE ENLARGED KITCHEN (1 O SUPPRESSION SYSTEM SO THAT ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL CUT POWER TO EQUIPMENT UNDER HOOD. POWER AND SYSTEMS PLAN 3. ROUTE CONTROL POWER THROUGH HOOD COP CONTROLS AND CONNECT TO GAS SOLENOID SCALE: 1/4"= 1r-O" VALVE AND SHUNT TRIP AT PANEL OF EQUIPMENT UNDER HOOD. ACTIVATION OF ANSUL FIRE SYSTEM SHALL SHUT OFF THE GAS SOLENOID AND POWER TO EQUIPMENT UNDER THE HOOD AS WELL AS ACTIVATE FIRE ALARM. 4 CONNECTED TS? gQO H T AND IGHTq 5. SEE ARCHITECTURAL/INTERIOR DESIGN ELEVATIONS FOR REQUIRED MOUNTING HEIGHT. _SHAFFER� fNCINEERINi. CRCCC.LLC ,xwe FLN JxbOnNlle FL33S!IH .Maep.wln ---- . zrzr, - , J. BRYAN SHAFF .E ICENSE # 58168 S p0 II / 6 DO m �j H Z o o z C o F— N w to h�I W W I O z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBUCATION THEREOF IS EXPRESSLY UMTTED TO SUCH USE. z U� cj ct w � V1 WI • o Ct Q " W tol B A S HAM & ]LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JB S DATE 03-26-14 JOB NO. 13-40 SHEET NO. E40 �- LC — I OFFICE -- E l�o A � --- PRIVATE F OFFICE DINING n 103 112J HEAD OLE F EEZER _.,� ,, . -N , ioo ipi STOR LOBBY / PRO \\ 114 - GOLF 121 SHjQP \, ExlsT- � RESTAURANT LSF 111 ll or0 - 2 l I� ) ii �, // ASSIST _..\ I �I PRO - N EXISTING C KI EN KWSMNGI� i�iH _-3 I - XISTI / EX r Or - -, 105� ®rXIST. 1 M A ' ETI - b D S EXIST. RAN RMER DPA L�I m RESTRM BTU-2J �ACCU_� -�" - AND LES C �' / �_ 113 r QI ;j / FIST. LRLU- HEAT-I \� �- 1 � _L HALL HALL MEMBER / DRY HALL I / 140 142 ENTRY �`l -- ' 123 I // AL 10 \ - 141— ANELS P3A, S R S MEMBER � lJT & B,3�3C VESTIBUL MENS II; 13s II MEN 01LET 1 !� I n 28 � ° / ° � -� ... .-., r _ ° TOILE ° a P O EF L_ � EF 2 D— °_-.� W E 31-� 3C-8 3 LE W I ° Z \ 144 11381 ti WE ° - ,j •I _ .f r 'L===43B _ lY —° FCU-1 MENS / T 11 P3D-2N �TOMEN LA\LAV 13MENSOMENS MEN lso / 147 J WOM COCKER 13 LCGKER 4 MpE�ETING SOCK LOCK -- L L13J 3 ry, i 304 1 / / 145 C S � I 155 i 100 r / / ® L—,J 1 - 4 14 3 FCU 2 a y. / P3D-1 I P3D 7 {�- S S. - _ _ 3 s �� VESTIBUL 3D-25 2 wP I L 131 31� �I — .wvfl MEEMBER 3C- T f--y 0 i 3 -18 30 ' L DINING _. 0 in, 1 44 -- - -�i_ = o P D-10 154 / F U-3 / PIATRO.N MEMBER P3C-8 FP ANTI ROOM TERRACE TERRACE L III i56 // l� 159 PANEL P4A 126 _I PANEL P46 _ I _ m m zZz a z � o W 0 0 I 0 4 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SII'E FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. aid ct P� � W 1 n1 I2� / _--- 4 1/ _ OVERALL_ 8c MECHANICAL BASHAM N POWER PLAN SCALE: 1 /8"= 1'-0W LUCA S \ _ " DESIGN GROUP, INC. \ - SITE PLAN NOTES: _ II < PLANNING -ARCHITECTURE -LANDSCAPE ® REFERENCE NOTE ON DRAWING 01 1. SEE POWER RISER DIAGRAM AND PANEL SCHEDULES FOR WIRE AND CONDUIT JAC GATE PARKWAY, #256 PAVILION REQUIREMENTS. �� )) - :JACKSO4) 1-2323 FAX E,FLORIDA 32699 i � I E57 �✓ (9Webs te: www:basham90cas. om2699 2. ALTERNATE FEEDER ROUTING. PROVIDE ALTERNATE PRICE. MBER Li0.Nos.: AA26000586 BAR �y 3. BASE BID FEEDER ROUTING. 125 IN-GROUND I 4. INCLUDE AS PART OF ALTERNATE PAVILLION #157 PLAN. HANDHOLE FIAWOL 5. INSTALL WP J-BOX AND (2) 2" CONDUITS WITH PULLSTRING TO ROOM 139. LOw 'a _„ _..,, -. -.-„�.,., . ,_r >-.�., .:�-,-., �� „ter.. �.�. �-.,.�.-...�.,-- ..-.,,..,_�.<•,- , / • hi- 6. EXISTING UNIT'TO REMAIN. L 7. EXISTING UNIT TO BE REPLACED. RE -USE EXISTING CIRCUIT AND FUSED 5 DISCONNECT. MODIFY FUSING AND WIRING AS REQUIRED. 8. CONNECT TO SWITCHED ROOM LIGHTING CIRCUIT. ?))- 9. INTERLOCK WITH RTU-3 EVAP. FAN MOTOR. 10. INTERLOCK WITH RTU-7 EVAR FAN MOTOR. SHAFFER 1 ENGINEERING CCOUh LLC -I- "'-..��.e.....-..�,... P3('i-2 P3`i-4 - J. BRYAN SU4€9 V E#58168 E r .9 •, STATE OF <U +. DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E404 0 0 ,. WOOF NA' L I ' I I I 1/ TTT� TO BE REMOVED w EXISTING POWER RISER DIAGRAM NOT TO SCALE EXISTING POWER RISER DIAGRAM NOTES: ® REFERENCE NOTE ON DRAWING 1. REMOVE EXISTING GROUND -NEUTRAL BOND. 15KW AHU-2/ AHU � 3 30 1 1)IHEA� 3 60 rEA-1 3 60 #3/0 IN 1"C. I I I 1LI II II i IIIIL rIIIPA—NE-L � IIIi rIPANEL �I PANEL PANEL �PANEL � PANEL TO BLDG. STEEL ;P1C' P2A'PIA' ;P1B' 'P1B2 ,� L LIL FORMERLYFORMERLYFORMERLYI(FORMERLYI(FORMRL�Y A) KA') ,I'KB') 'BA') I III III 'BB') I I SWBD I III PANELEXISTING 200A 1CBA II II II II fI II T II CONIII IIL 00A _ L. M.L.O. L 0-.KWHM MDOA 200A 200A 100A 225A 200A 2 M�MI _ L J . .. JO 208/120V I 208/120V NEMA 3R NEMA 3R 208/120V 208/120V J 208/120V L 208/120V J L_ 208/120V 208/120 JVJ T Tr EXISTING II I(II IIII UTILITY III I TRANSFORMER® SPD I I I I I I I I I I I i I I --I -----= —----------------------------------- ----- ----------------------- J — — — — — -- #3/0 IN 1 "C - 60 35 P PHOTO TYP.)CELL AT ROOF ( PANEL PANEL PANEL PANEL PANEL PANEL 'P4B' CHEFS PANEL 'P3A' 'P3B' 'P3C' 'P3D' 'P4A' OTHERS) 225A 225A 225A 400A 225A 225A 125A M.L.O. M.L.O. M.L.O. NCONT M.L.O. M.L.O. M.L.O. 208/120V M.L.O. 208/120V 208/120V 208/120V 208/120V 208/120V 208/120V TO METAL WATER PIPE, EXISTING SERVICE GROUND AND BUILDING FOUNDATION REINFORCIN BAR NO LESS THAN 20 LONG, 1/2 NEW POWER RISER DIAGRAM NCH MINIMUM DAMETERFEET — — — — EXISTING NOT TO SCALE 3/4" x 16' COPPER CLAD GROUND ROD NEW POWER RISER DIAGRAM NOTES: 16'® I REFERENCE NOTE ON DRAWING 1. EXISTING WIRE AND CONDUIT TO REMAIN. 4. CONTRACTOR SHALL COORDINATE WITH FPL FOR UPGRADE OF ELECTRICAL SERVICE (AND TRANSFORMER IF REQUIRED) PRIOR TO BID. ALL FPL 2. SEE PANEL SCHEDULE FOR WIRE AND CONDUCT SIZES. REQUIREMENTS SHALL BE INCLUDED IN THE ELECTRICAL DESIGN AS PART OF THE BID. 3 6 SETS: (4)#400, 3" C. 5. CONNECT SHUNT TRIP BREAKERS TO HOOP CONTROL SYSTEM WITH (3) #12, 1 /2" C. SHAFFER 1 `ENGINEERING 9111010FALC _ 13QN5 JMBI�Sib WJ 1�1 d6R1, f%I9w1�� l CMA RUWA"b M 1B]65 J. BRYAN SHiKFQf.P LICENSE # 68168 4.0 IN 5 ,,,i,S i6 IN 0- m m zZ 0 Q a z p o �i NLLI E] N K W W i 0 0 o Q THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SWILL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY UMITED TO SUCH USE. ramr/' C^A W' �.I..� `v ^ l 5 cat U1 C U - - �� ^^; \%wooI W �%MOO) �21 1 e'I o� BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lie. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E591 4" SQUARE - DEVICE BOX BOX DEVICE COVER WITH - RAISED RING OF PROPER DEPTH AND TYPE FOR WI CONSTRUCTION. RING TO FINISH FLUSH WITH WALL DEVICE TRIM AI FOR EMT, CONNECTORS SHALL BE COMPRESSION TYPE, WITH INSULATED THROAT MAKE CIRCUIT JOINT WITH TWIST -ON CONNECTOR, AND CONNECT TO DEVICE WITH SINGLE LEADS. 1#12 AWG GREEN INSULATED JUMPER TO BOX BONDING SCREW 1#12 AWG GREEN INSULATED JUMPER TO DEVICE GROUNDING SCREW NTYPSCALE ICAL DUPLEX RECEPTACLE INSTALLATION BRANCH CIRCUIT CONDUIT Y-IN JUNCTION BOX ATTACHED TO STRUCTURE 6 FT MAX. LENGTH OF FLEXIBLE CONDUIT TO ALLOW AFOR RELOCATION. INCLUDE GROUND WIRE. MAXIMUM OF THREE (3) FLEX. RUNS PER JUNCTION BOX. LAY —IN TYPE FLUORESCENT TROFFER SEE LIGHTING FIXTURE SCHEDULE FASTEN TO CEILING MEMBER BY BOLTS, SCREWS OR RIVETS AT 2 LOCATIONS OF EACH OF THE TWO LONG SIDES. TYPE "G" INVERTED "T" CEILING GRID. SECURE FIXTURE TO GRID WITH APPROVED METHOD, FOUR PER FIXTURE. =IXTURE INSTALLATION - DETAIL EMERGENCY LOCAL LIGHT OFF SWITCH NORMAL LIGHT IIIPACK T ANY LINE VOLTAGE OCCUPANCY SENSOR USING TERMINALS +� OCCUPANCY -0 SW SENSOR - COMMON +24V COMMON USING FOUR TERMINALS y CONTROL OUT PUT • �L SW OCCUPANCY SENSOR COMMON +24V COMMON USING FOUR TERMINALS LIGHTING MOTION SENSOR DETAILS TIME CLOCK TROK. DC-100 TIMER AT PANE NYLON BUSHING NYLON BUSHING LAY -IN CEILING (TYP) 1 "E.C. WITH 1 "E.C. WITH PULLSTRING PULLSTRING N TYPICAL TEL./DATA OUTLET GROUND BUS #6G, 3/4" C. TO PANEL GROUND- 2 1 /2"C. TO ABOVE CEILING -PROVIDE BUSHING (TYPICAL) PROVIDE 4'X4' TELEPHONE BOARD PAINTED WITH GREY FIRE RETARDANT PAINT. L (2) 3" CONDUITS W/ PULLSTRING TO PROPERTY LINE FOR TELEPHONE AND TV SERVICE TELEPHONE/DATA/TV SINGLE LINE DIAGRAM 6" t EXISTING GRADE FOIL BACKED RED WARNING RIBBON RED 12„ II II1II I II II I II I II I EXCAVATE AND BACKFILL WITH EXISTING SOIL. III —I I �—III— I I- -I III=III—III=III= SCHEDULE 40 P.V.C. CONDUIT 6" MIN. O FILL AROUND CONDUIT WITH FINE SAND DIRECT BURIED CONDUIT DETAIL NOT TO SCALE PHOTOCELL EXTERIOR LIGHTING CONTACTOR PROVIDE 1-8 POLE 30 AMP _ ELECTRICALLY HELD CONTACTOR AND ROUTE CIRCUITS THRU CONTACTOR. PROVIDE 120V — J COIL, PROVIDE PHOTOCELL, MOUNT 6" ABOVE ROOF AND OVER RIDE SWITCH AT PANEL MARKED "EXTERIOR LIGHTING". VERIFY NUMBER OVER OF REQUIRED POLES WITH QUANTITY RIDE SWITCH OF NEW AND EXISTING EXTERIOR LIGHTING CIRCUITS. �-------_ � EXTERIOR LIGHTING CONTROL DIAGRAM NOT TO SCALE C 3/4"C. TO TEL. BOARD DIALER[ SEE NOTE 6 FIRE ALARM — CONTROL PANEL E ALARM CABLES IN CONDUIT. TO FIRE ALARM DEVICES 120V CIRCUIT .. ov:i FIRE ALARM RISER DIAGRAM NOT TO SCALE FIRE ALARM RISER NOTES 1. ALL FIRE ALARM WIRING SHALL BE INSTALLED IN CONDUIT SIZED PER 6. PROVIDE AUTOMATIC TELEPHONE DIALER. COORDINATE WITH MONITORING N.E.C. AND NFPA-70, ARTICLE 760. COMPANY FOR TYPE OF EQUIPMENT. DIALER SHALL MEET ALL REQUIREMENTS OF NFPA. 2. PROVIDE AND INSTALL ANNUNCIATOR, UNIT SHALL BE FLUSH MOUNTED. 7 ALL WIRES SHALL BE IN CONDUIT. LIFE SAFETY BRANCH POWER IS 3. SEE MECHANICAL DRAWINGS FOR QUANTITIES AND EXACT LOCATIONS OF SHOWN AT F.A.C.P. IF ADDITIONAL POWER IS REQUIRED IN A REMOTE DUCT TYPE SMOKE DETECTORS, FLOW AND TAMPER SWITCHES. POINT FROM F.A.C.P. CONTRACTOR SHALL BE RESPONSIBLE TO RUN NEW WIRING AND CONDUITS AT NO ADDITIONAL COST TO THE OWNER. 4. PROVIDE FIRE ALARM SHUT —DOWN RELAYS AT ALL HVAC EQUIPMENT. 8. FIRE ALARM SHALL BE VOICE EVACUATION TYPE. 5. REMOTE FIRE ALARM ANNUNCIATOR PANEL SHALL BE BOTH VISUAL AND AUDIBLE. 9. COORDINATE WITH FIRE PROTECTION CONTRACTOR AND FINAL FIRE PROTECTION DRAWINGS TO CONNECT ALL REQUIRED DEVICES OF FIRE PROTECTION SYSTEM TO FIRE ALARM SYSTEM. RECEPTACLE WITH WEATHER PROOF COVER. SEE FLOOR PLAN FOR OUTLET RATINGS COUPLING AND PLUG TO BE FLUSH WITH FINISH FLOOR BRASS 4" x 4" x 2" STAINLESS STEEL BOX WITH GASKET COVER 2" 1-1/2" GALVANIZED RIGID STEEL CONDUIT SURFACE MOUNTED FLOOR NOT TO SCALE ./-�.%� ��/-��--fir'V�'✓'s�.� �,�_'�.i"'�'�/"v-�.F���-�/'\r��-�/"�i-V"V"�./"�,^,--.i j w 24" X 36" 30"D HANDHOLE QUARZITE: BOX #PG2436BB30, COVER #PG2436HA00 —7 I GRADE 111_l I Ml I I III-�III � �-III Ili-1 � M � —III—III- 4 I —III -I I I 1=III=III_ III=III-III-III-I � -III-III 0 0 0 0 0 0 c 0 o 0III-III-III III —III 00000000c 0 0 0 0I 8—III-I I I -I I H I II I II I II I I �ODO 00000000c 000 I I I II I II I II I II I II 1-� CRUSHED ROCK OR GRAVEL CONDUIT AS SPECIFIED DOM zZ 0 o z � o -- NLLI o n W Ld 0 0 I o Qz THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP. AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY UMTED TO SUCH USE. C/1 u ct 1� 4-4ct� W cn U r� O T BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 ON DRAWINGS FLOODLIGHT DETAIL NOT TO SCALE NOTES. Q1 PREPARE THE EXCAVATION APPROXIMATELY 6" DEEPER THAN BOX, THEN ADD 8" OF GRAVEL OR CRUSHED ROCK FOR DRAINAGE. 1, Q2 PLACE BOX IN HOLE WITH TOP AT GRADE LEVEL. Q3 FILL WITH COMPACT SOIL TO GRADE LEVEL WITH COVER ON BOX.- ® PROVIDE FLEXIBLE SEALANT AT ENDS OF CONDUITS AROUND CABLES. I AILE COPY CONCRETE HANDHOLE DETAIL NOT TO SCALE 1 SHAFFER ENCINEERINC URUUP.LLC ��1111 FxPHH z91111 7DRAWN BY M D BY S DATE 03-26-14 JOB NO. 13-40 SHEET NO. E5.2 (Z i I SWBD MDP MOUNTING: STYLE: ENCLOSURE TYPE: SURFACE SQ. D CIO NEMA 311 VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE AMPS: 2000 M.C.B. OR M.L.O: MCB :AIC RATING 65,000 .CIR BREAKER LOAD NUM DESCRIPTION POLE SIZE WIRE/CONDUIT KVA 1 SURGE PROTECTION 3 60 2 PANELS P3A/P3B/P3C 3 225 (4) #4/0, #4G,2 1/2" C. 74.8 3 PANELS P4A/P4B 3 225 (4) #4/0,#4G, 2 1/2" C. 56 4 PANEL P3D 3 400 2 SETS: (4) #4/0, #2G, 2 1/2"C. 140 5 PANEL DPA 3 1000 3 SETS: (4)#400, #2/OG, 3" C. 320 6 SPARE 3 100 7 SPACE 3 400 8 SPACE 3 400 PANEL LOAD KVA 590.7 AMPS 1641 iNOTES: @ 208V, 3 PHASE 3 v- n 1 /1\ l i i i j f AX MOUNTING: FLUSH PANEL P 1 C VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: EXISTING AMPS: 225 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL KB) M.C.B. OR M.C114*411I• MLO AIC RATING EXISTING CIR BREAKER LOAD PHASE LOAD BREAKER I CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C O I /C T JlES, P t3U 1 MOBILE HEATED CABINET #10,#10G ,1/2" 30 1 2 X X X j XI X'- X X 1 X X X X + X X X X X X 1.9 1 20 EXISTING EXIST. HOOD EXH. 2 3 GAS SKILLET (50) #12,#12G, 1/2" 20 1 0.1 1.9 1 20 EXISTING EXIST. HOOD EXH. 4 5 SHUNTTRIP 1.9 1 20 EXISTING EXIST. HOOD SUPPLY 6 7 GAS RANGE/DUAL OVENS (61 #12,#12G, 1/2" 20 1 1 1.8 0.4 3 20- #12,#12G,1/2" HOOD MUA FAN 8 9 SHUNTTRIP 0.4 ) 10 11 ROTISSERIE OVEN (1) #8,#10G, 3/4" 50 1 3 3.9 0.4 ) 12 13 ) 3.9 0.7 1 20 #12,#12G, 1/2" HOOD LIGHTS/CONTROLS 14 15 ) 3.9 0.2 1 20 #12,#12G,1/2" WORK TABLE (10S) 16 17 SHUNTTRIP 0.9 1 20 #12,#12G,1/2" SODA SYSTEM (106) 18 19 POS (82) #12,#12G, 1/2" 20 1 1.2 20 #12;#12G YJ2" S FRYERS1651 "'' -^ -' -26J 21 POS (82) #12,#12G, 1/2" 20 1 1.2 SHUNTTRIP 22 23 SODA DISPENSER (90) #12,#12G, 1/2" 20 1 1.5 1 120 SPARE 24 25 REFRIG. CHEF BASE (62) #12,#12G, 1/2" 20 1 0.9 A -IPI- I : {77},•-_2y- 27 SHUNTTRIP 0.2 1 20 #12,#12G, 1/2" BEVERAGE TABLE (76) 28 29 PIZZA OVEN (55,56) #12,#12G, 1/2" 20 1 0.4 - -4 ` 31 ..EXIST. ICE MACHINE #12,#12G, 1/2" 20 3 1.3 0.2 1 20 #12,#12G, 1/2" BEVERAGE TABLE (89) 32 33 ) 1.3 1 2,i�2 ,i 1/2 ACKBREFkI 108�'' -14- 35 J 1.3 0.6 1 20 #12,#12G, 1/2" BOTTLE COOLER (112) 36 37 ICE TEA BREWER (93) #12,#12G, 1/2" 20 1 1.8 1.8 1 20 #12,#12G,1/2" COFFEE BREWER (87) 38 39 REACH -IN REFRIG. (94) #12,#12G, 1/2" 20 1 0.8 1$ ) #12&�/2 QFF€E.BREWER f87) r 40 41 SODA DISPENSER (104) #12,#12G, 1/2" 20 1 1.5 0.2 1 20 #12,#12G, 1/2" BEVERAGE TABLE (92) 42 PANEL LOAD KVA AMPS NOTES: PHASE A... 19.6 163 1,2,8 PHASE B 12.5 104 PHASE C /144, 120 TOTAL 46.5 129 @ 208V, 3 PHASE X 65% DEMAND: 30.225 KVA STYLE: 0 NTING: EXISTING PANEL P 1A AMPS.FLUSH OLTS & PHASE 208/120V, 3 PHASE; 4 WIRE 00 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL A) M.C.B. OR M.L.O: MLO AIC RATING EXISTING CIR BREAKER LOADPHAS LOAD BREAKER CIR N M DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM i ` LIGHTS - KITCHEN #12, #12G, 1/2" 20 1 1.7 X X X X X X X ( X X X� X X) , X r' <i X; `1 � X� X 1.5 1 1 20 EXISTING EX. BANQUET LIGHTING 2 3 EX. BANQUET LIGHTING EXISTING 20 1 1.5 1.5 1 20 EXISTING BANQUET LIGHTING EX. BAN Q 4 5 EX. BANQUET LIGHTING EXISTING 20 1 1.5 0.5 1 20 EXISTING EX. BANQUET FB 6 7 EX. BANQUET FANS EXISTING 20 1 1.5 0.5 1 20 EXISTING EX. BANQUET RECEPT 8 9 REC-BAR GP #12, #12G, 1/2" 20 1 0.4 0.5 1 20 EXISTING EX. BANQUET RECEPT 10 11 SPACE '0:5 I 0 TJOSTING--' ` - X: BANQUENtECEPT' v !12', 13 SPARE (EX) 20 1 1.4 1 20 #10, #10G, 1/2" PRIVATE DINING/SALES LTG 14 1 20 SPARE 16 1 ' LIGHTS -BAR #12, #12G, 1/2" 20 1 0.2 I� fi 20 EXTfTING���'� X13TI�1G L�GW fI�1G"�� 19 REC 112,113 #12, #12G, 1/2" 20 1 0.4 1.2 1 20 #12, #12G, 1/2" KIT. GENT. RECEPTS 20 21 REC-111, TV #12, #12G, 1/2" 20 1 0.6 0.2 1 20 #12,#12G, 1/2" EXTERIOR RECEPTS 22 23 ` RESTAURANT CHANDELIERS #12, #12G, 1/2" 20 1 1 0.6 1 20 #12, #12G, 1/2" KIT. OFFICE RECEPTS 24 25 SPARE 20 1 -1 -2-& SPARE, -26-- RESTAURANT DOWNLIGHTS #12, #12G, 1/2" 20 1 1.3 1 20 SPARE (EXISTING) 28 -ZL 2 - REC-111, TV #12, #12G, 1/2" 20 1 0.6 1 20 SPARE (EXISTING) 30 31 SPARE 20 1 1 20 SPARE (EXISTING) 32' 3 EX. RESTAUARNT RECS EXISTING 20 1 1 0.2 1 20 #12, #12G, 1/2" REC 34 315, EX. RESTAUARNT RECS EXISTING 20 1 1 20 SPACE 36 37 COOLER/FREEZER/KITCHEN LT #12, #12G; 1/2" 1 20 1 0.7 0.7 3 20 #12, #12G, 1/2" HOOD EXHAUST FAN 38 3 HO013 tT5/Cfl1 ITR�t Y,12 ,C~ D 3 0.7 ) 40 4� BEVERAGE TABLE #12, #12G, 1/2" 1 20 1 0.3 0.7 ) 42 PANEL LOAD KVA AMPS NOTES: PHASE A 9.6 80 1,8 PHASE B 8.2 68 PHASE 7_9 65 TOTAL 25.7 71 @ 208V, 3 PHASE MOUNTING: FLUSH PANEL P2A VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: 3E POWERMARK AMPS: 200 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL BA) M.C.B. OR M.L.O: MLO AIC RATING 10,000A C R BREAKER L A 0 D HA S LOAD BREAKER CIR . NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVAA.BC KVA POLE SIZE WIRE/CONDUIT DESCRIPTION. NUM lr EX. LOBBY LTS PENDANTS EXISTING 20 1 1.8 X X X X X X X XI / X X y X X X X X X X X X X X 0.5 1 20 EXISTING MERCH. STORAGE LIGHTS 2 3 EX. LOBBY LTS - PENDANTS EXISTING 20 1 1.8 0.5 1 20 EXISTING ATTEND/DRESSING - LIGHTS 4 5 EX. LOBBYLTS- SCONCE EXISTING 20 1 1.8 0.5 1 20 EXISTING EXISTING CIRCUIT 6 7 EX. LOBBY LTS - SCONCE EXISTING EXISTING 20 20 1 1 1.8 0.5 -0 ,7---- --2Q 9 EX. PRO SHOP FLOOR BOX 0.4 1 20 #I0,#10G, 3/4' EXTERIOR LIGHTING 10 �1h-�X:$,©U[9PSYSTEM-✓"�..( XISTING-��-.,-30 � .0.5, Pi10E� 13 REC - PLATFORM #12,#12G / 1/2" 20 1 03 SPACE 14 15 SPARE 20 1 SPACE 16 17 LIGHTED DISPLAY #12,#12G / 1/2" 20 1 1.5 SPACE 18 19 REC 115 #12,#12G / 1/2" 20 -1 1.3 SPACE 20 1` i}ARE-� _ •__-a tip_ 1 -1 SPACE 22 23 SPARE 20 1 SPACE 24 25 SPARE 20 1 SPACE 26 27 SPARE 20 1 SPACE 28 29 SPARE 20 1 SPACE 30 31 SPARE 20 1 SPACE 32 33 90, F, + SPACE 34 3$ SPACE' SPACE 36. 3! SPACE SPACE 38' 39 SPACE SPACE 40 41 SPACE SPACE 42 PANEL LOAD KVA AMPS NOTES:. PHASE A 66 55 1,8 PHASE B - 3.2 26 PHASE C .3 35 TOTAL 14.1 39 @ 208V, 3 PHASE MOUNTING: FLUSH PANEL P 7. B VOLTS & PHASE; 208/12OV, 3 PHASE, 4 WIRE STYLE: EXISTING AMPS: 200 ENCLOSURE TYPE: NEMA 1 (EXIST. PNL KA) M.C.B. OR M.L.O: MLO AIC RATING EXISTING CIR BREAKER LOAD HAS LOAD BREAKER I CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE I WIRE/CONDUIT DESCRIPTION NUM 1 W/1 COOLER EVAP. (2)' #12,#12G, 1/2" 20 1 0.2 X X X X X X X X X X X X X X 1 2 20 #12,#12G, 1/2" FREEZER EVAP (6) 2 3 BEER COOLER EVAP (4) #12,#12G, 1/2" 20 1 0.2 1 1) ' . 4 5 FzR DOOR HEAT/LIGHTS (1) j #12,#12G, 1/2" 20 1 1.2 X 1.2 3 20 #12,#12G,1/2" W/I COOLER CU (3) 6 7 SODA SYSTEM (14) #12,#12G, 1/2" 20 1 0.9 1.2 ) 8 9 BENCH MIXER (16) #12,#12G, 1/2" 20 1 1.5 1.2 ) 10 11 FOOD PROCESSOR (18) #12,#12G, 1/2" 20 1 1.5 X 0.7 3 20 #12,#12G, 1/2" BEER COOLER CU (5) 12 13 DISPOSER (21) #12,#12G, 1/2" 20 3 0.7 0.7 ) 14 15 ) 0.7 17 ) 0.7( 1 3' 100 (4)#3,#8G,11/4" PANELPIB2 18 19' MOBILE PREP (36) #12,#12G, 1/2" 20 1 1.5 / 1 ) 20 21 MOBILE PREP (36) #12,#12G, 1/2" 20 1 1.5 1 ) 22 23 AIR CURTAIN #12,#12G,1/2" 20 1 1 . ---- 26- 25 HOBART FLOOR MIXIER (10) #12,#12G, 1/2" 20 3 0.7 1.1 3 20 #12,#12G, 1/2" FREEZER CU (7) 26 27 ) 0.7 1.1 ) 28 29 ) 0.7 X 1.1 ) 30 31 'BOOSTER HEATER (30) #6,#10G, 1" 60 3 5 0S 3 20 #12,#12G,1/2" DISPOSER (31) 32 33 ) 5 0.8 ) 34 35 p 5 X 0.8 ) 36 37 DISHWASHER (29) #6,#10G, 1" 60 3 5.5 0.6 1 20 #12,#12G, 1/2" BOTTLE COOLER (116) 38 39 ) 5.5 1 20 SPARE 40 41 ) 5.5 X 1 20 SPARE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 20.85 173 1,2,8 PHASE B 20.85 173 PHASE C 20.4 170 TOTAL 62.1 \ 172 @ 208V, 3 PHASE X 65% DEMAND - 40.365 KVA jMOUNTING; FLUSH i /� +� N E L P 1 B 2 'VOLTS & PHASE; `AMPS: 1208/120V, 3 pHASEt 4 WIRE1 'STYLE- � SQ 0 NCEOD IPA { 10W _ INNCOOSURE TYPE . _ __. NEMA 1 I i M.C.S. M,L O I I M10 _ --#-:. -,AIC _OR S i RATING 1Di100! � CIR BREAKER _LOAD HA5 LOADBREAKER OR NUM {�t=cr#LPT1nm %AARr1rntdAIIIT f17F 0"t WXYA a M r IrVA POIr SIZE WIRE CONDUIT Z -' (� ( ` 1 REC -Sol 3 COFFEE 5 SPARE 7 SPARE 9 SPARE 11 SPARE 13 SPARE 15 SPARE 17 SPARE 19 SPACE 21 SPACE 23 SPACE 25 SPACE 27 SPACE 29 SPACE 0 L2,#12G,1/2" 20 1 05 E2,#12G, ll2" 20 1 1 20 1 20 1 20 1 20 1 20 1 20 1 20 1 PANEL LOAD +KVA AMPS % 1PHASEA 1 __ --1-_ _ IB PHASE B _+8 PHASE 0 t 0 TOTAL. t WIRE MOUNTING: FLUSH PANEL P 2 B VOLTS & PHASE: 208/12OV, 3 PHASE, 4 STYLE: EXISTING AM PS: 200 ENCLOSURE TYPE; NEMA 1 ( EXISTING PNL BB) M.C.B. OR M.L.O: MILO AIC RATING EXISTING OR BREAKER LOAD HAS LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 EX. CIRCUIT EXISTING 20 1 0.5 X X X X X X X X ) X X )( X IIX. X X SPACE 2 3 EX. CIRCUIT EXISTING 20 1 0.5 SPACE 4 5 EX. RECEPTACLES EXISTING 20 1 1 X SPACE 6 EX. RECEPTACLES EXISTING 20 1 1 SPACE 8 EX.RECEPTACLES EXISTING 20 1 1 1 1 20 EXISTING EXISTING CIRCUIT 10 1 EX. EXIT LIGHTS EXISTING 20 1 0.5 X SPACE 12 1 EX. TELEPHONE BOARD EXISTING 20 1 0.5 SPACE 14 15 EX. OFFICE REC. EXISTING 20 1 1 1 1 20,' EXISTING EX. IG COMPUTER 16 17 EX. OFFICE REC. EXISTING 20 1 1 X 1 20 SPARE 18 19 EX. LOBBY REC. EXISTING 20 1 1 1 1 20 EXISTING EX. WALL LIGHTING 20 ^� - ,- � EX: tOBB�GREC: �, -.; - .EXISTANG.- -�.-- . 20., - - � 3-� 3�; 7�--:,20 �G ��--. ,-LIGEITINIav��^✓ �� 23 PRO SHOP FLOOR BOX #12, #12G, 1/2" 20 1 0.4 2 30 SPARE (EXISTING) 24 2 PRO SHOP FLOOR BOX #12, #12G,1/2" 20 1 0.4 ) 26 2h` �EX'PtRE_AL1`tM`PAM1fL'L a 'fYS 0.2 1 20 EXISTING EX. LIGHTING 28 29 EX. RECESSED LTG EXISTING 20 1 1 1 20 SPARE 30 3& X: R€6€SSEQLT6 - - XiSFfNG^✓- 2Q k 1 1.2 1 20 ' #12, #12G, 1/2" PRO SHOP PENDANT LTG 32 33 EX. LIGHTING EXISTING' 20 1 1.5 1 1 20 EXISTING EX. LIGHTING 34 31 EX. LIGHTING EXISTING 20 1 0.9 X - -- - : gAL'L LIGHTS" J XISTMdt 20 i- 3' UNUSABLE SPACE 38 39 OFFICE 121/122 LIGHTS #12, #12G, 1/2" 20 1 0.3 UNUSABLE SPACE 40 41' EX. EXIT LIGHTS EXISTING 1 0.5 X UNUSABLE SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 7.6 63 1,8 PHASE B 10 83 PHASE C ` 5.3 44 TOTAL 22.9 63 @ 208V, 3 PHASE )_5 2 20 / #12,#12G, 1/2" DESCRIPTION BAR CABINETLIG14TING SPARE NUM 2 4 1 20 1 20 SPARE 6. 1 20 SPARE SPAR€ SPARE SPARE SPACE SPACE 8 10 12 14 16 18 7 20 1 20 1 20 SPACE SPACE SPACE SPACE 24 NOTES r ) ` PANEL SCHEDULE NOTES: Q9 REFERENCE NOTE ON DRAWING 1. CIRCUITS, MAY BE GANGED TOGETHER WITH THE WIRE SIZES INDICATED FOR UP TO THREE CURRENT CARRYING CONDUCTORS IN A CONDUIT. WHEN THE NUMBER OF CURRENT CARRYING CONDUCTORS EXCEEDS THREE, WIRES SHALL BE UPSIZED AND DERATED IN ACCORDANCE WITH NEC TABLE 310.15(B)(2)(a). CONDUIT SIZES SHALL BE ADJUSTED TO COMPLY WITH NEC TABLES FOR CONDUCTOR FILL BASED ON CONDUIT TYPE. 2. CONTRACTOR SHALL VERIFY ALL KITCHEN EQUIPMENT POWER REQUIREMENTS PRIOR TO INSTALLATION. 3. SERVICE ENTRANCE RATED. z1\ 4. INSTALL ,NEW BREAKER IN EXISTING PANEL. 5. PROVIDE' SHUNT TRIP BREAKER. FILE 6. ROUTE THROUGH LIGHTING CONTACTOR. 7. CONNECT SHUNT TRIP TO HOOD FIRE SUPPRESSION SYSTEM. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL TRIP BREAKER. 8. PRIOR TO BID FIELD VERIFY WHICH BREAKERS MAY BE RE -USED AND WHICH BREAKERS Af?E REQUIRE TO BE NEW. SHAFFEER' i EN0I NEEAi N'0 OEOOP. LLC. sox --- Jed Nlle FLExxJ wiw'ANe�eO.mm PH�BW �x99a0n FX �M1�2393020 CaNfiaMMAWMxYlonp x0M5 J. BRYAN SHAFFE . LICENSE # 58168 its uri,$ i b. TE OF I '��TU m m zZ O a z � o H 0 0 I O 4 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP. AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM & ]LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY .1)3 S DATE 03-26-14 JOB NO. 13-40 SHEET NO. E6,01 MOL NTING: SSURFACE QDNQ PANEL P3A AMLPS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STY: S: 225 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO AIC RATING 10,000A CIR BREAKER LOAD LOAD BREAKER CIR pq ,__v.._1�E LRTIQN-, - - .y4RF/CONQQIT_ SIZE. Old 4V ABC KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 REC-MEMBER DINING #8, #8G / 3/4" 20 1 0.7 )) )X ( 9 )( X 1 X X X X X X X X X X X X X X 1 X XI 0.4 1 20 #12, #12G / 1/2" FACP 2 3 REC-MEMBER DINING #8,#8G/3/4" 20 1 0.5 0 1 -2A ,kj2Gti_12 ��C155 - -. ,. ;, 4--. 5 REC-DINING SERVICE #8, #8G / 3/4" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-147 6 7 REC-DINING SERVICE #8, #8G / 3/4" 20 1 0.2 1 -%= r2##2 E4 -i •;i 9 REC-DINING SERVICE #8, #8G / 3/4" 20 1 0.2 0.5 1 20 #12, #12G / 1/2" REC-147 10 11 REC-LOCKER 130 #10, #10G / 1/2" 20 1 0,5 f '20- #12'412'Oi / 1/2" `-' -' "J 2 1 REC-LUC�R 1 �_- - #12, �11G 1 20 1" -0. 0.2 1 20 #12, #12G / 1/2" REC-150 14 15 REC-LOCKER 130 #12, #12G / 1/2" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-150 16 17 REC-LOCKER 132 #12, #12G / 1/2" 20 1 0.2 0.2 1 20 #12, #12G / 1/2" REC-151 18 19 REC-LOCKER 132 #12, #12G /'1/2" 20 1 0.2 ,Qfr 1, -20- 21 REC-LOCKER 137 #12, #12G / 1/2" 20 1 0.2 1 20 SPARE 22 23 REC-132, 134,138 #12, #12G / 1/2" 20 1 0.5 0 T` 20 *ll,)n IG /l/2" 25 REC-143 #12, #12G / 1/2" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-145 26 27 �FC_�46��� _ _� - 2-, #12G /, -, 1-, -9 4 0.4 1 20 #12, #1213 / 1/2" REC-124 FLOOR BOXES 28 29 REC-123, 140 #10, #10G / 1/2" 20 1 0.9 1 20 SPARE 30 DISRL'AfbGHTtf4G"' 12 #12G t l% 2f1 ' ' 1 = 1 20 SPARE 32 33 DISPLAY LIGHTING #12, #12G / 1/2" 20 1 1 1 20 SPARE 34 2-, 2 20-_ 4-., 4 1 20 SPARE 36 37 REC-159 #10, #10G / 1/2" 20 1 0.5 1 20 SPARE 38 39 REC-157 #10, #10G / 1/2" 20 1 0.7 1 20 1 SPARE 40 1 ZS}5$ - ^ #12, #11- /'I/ 30-- `1- 6 1 1 1 20 1 ISPARE 42 PANELLOAD KVA AMPS NOTES: PHASE A 4.7 39 1,2 PHASEB 5.4 45 PHASE C j 5 41 TOTAL 15.1 41 @ 20 IV, 3 PHASE MOUNTING: SDURFACE NQOD PANEL P3 D AMPS.& PHASE: 208/12OV, 3 PHASE, 4 IRE STYLE: SQ ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO AIC RATING"' 10,000A CIR BREAKER LOAD HAS LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE I POLE I KVA A B C KVA POLE SIZE' WIRE/CONDUIT- DESCRIPTION NUM 1 RTU-1 #8,#lOG,1" 3 45 3.8 X X X X X X X X X X X X X (" X X"`- X X X 0.1 2 15 #12, #12G, 3/4" FCU-1 2 3 ) 3.8 0.1 ) 4 5 ) 3.8 0.1 2 15 #12,#12G,3/4",FCU-2 6 7 RTU-2 #8, #10G, 1" 3 45 3.8 0.1 ) 8 9 ) 3.8 0.1 2 15 #12, #12G, 3/4" FCU,3 10 11 ) 3.8 0.1 ) 12 13 RTU-3 #2, #8G, 11/2" 3 100 j.2 0.1 2 15 #12,#12G,3/4" FCU-4 14 15 ) 8.2 ,1 17 ) 8.2 2 3 30 #10, #10 ; . 4" HP-1- CIRCUIT A 18 19 RTU-4 #2, #8G, 1 1/2" 3 100 9.5 ) 20 21 ) 9.5 2 ? 22 23 ) 9.5( 1 20 SPARE 24 25 RTU-5 #2, #8G, 1 1/2" 3 100 8.2 1 �1�1 ' #12G" FT 1�ORTH '� 27 ) 8.2 �� "s50UTkV v --28- 29 ) 8.2 2 3 30 #10,KOG, 3/4" HP-1- CIRCUIT B 30 31 RTU-6 #2, #8G, 1 1/2" 3 100 8.2 2 ) 32 33 ) 8.2 2 ) 34 35 ) 8.2 37 SPACE SPACE 38 39 SPACE SPACE 40 41 SPACE SPACE 42 PANELLOAD KVA AMPS NOTES: PHASE 47 391 PHASE 47 391 PHASEC 382 TOTAL 139.9 388 @ 208V, 3 PHASE NTING: SURFACE MOUNTING: S PANEL P3 B VOLTS&PHASE:HASE: 208/12OV, 3 PHASE, 4 IRE Q. 225 STY ENCLOSURE TYPE: NEMA 1 .C.B. OR M.L.O: MLO A C RATING 10,000A CIR'. BREAKER LOADPHASE LOAD BREAKER CIR NUM'' DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION - NUM 1 iYGH1S-123,116-i 7 ISO, #10 , 1 20 1 b[7 X X�- X X 1 i "I�X X X X % X[ $ X X ( X X X X X 0.2 1 20 #12, #12G, 1/2" LIGHTS - MERCH. STOR. 2 3 LIGHTS- MEMBER DINING #8, 48G, 3/4" 20 1 0.7 , `6T ' "20 #10, #1i0G " EXTERIilR LffiHTS S� � � 5. ' LI HTS - MEMBER INI G #8 48G, 3/4" 0 1 1 0.8 1 20 #12, #12G, 1/2" LIGHTS - WOM. LOCKER 146 6 y 16HT #3@r.#10CT,1 '20 x5 0.6 1 20 #12, #12G, 1/2" LIGHTS - WOM. LAV. 147 9 SPARE 20 1 0.6 1 20 #12, #12G, 1/2" LIGHTS -MENS LOCKER 151 1 IGHiS%'HALIS i� _ ; #10C,;-1�2 y" i i:1 0.8 1 20 #12, #12G, 1/2 " LIGHT MIENS LAV. 149 S - 1 ' 13 LIGHTS - MTG & ANTI ROOMS #12, #12G, 1/2" 20 1 0.9 1.1 -1 20 #12, #12G, 1/ LIGHTS- WOM. LOCKER 137 14 15 LIGHTS- GALLERY #12, #12G, 1/2" 20 1 1.7 ,1.1 • i -20,- #13 #12G 3f2 IGHTs'- WOw Av:--lw .- .16 17 DISPLAY CASES - GALLERY #12, #12G, 1/2" 20 1 1.8 0.4 1 20 #12, #12G, 1/2" LIGHTS - MENS LAV. 149 18 19 LIGHTS -TERRACES #10, #IOG, 1/2" 20 1 1.1 1.6 1 20 #10, #10G, 1/2" LIGHTS - MENS LOCKER 151 20 21 LIGHTS - TERRACES #10,#10G,1/2" 20 1 1 1 20 SPARE 22 - 23 1GH,TS-.TERRACES- - ; -�i -2;,#32,0i lY ' 20 - fir- �1.A 1 20 SPARE 24 25 �L LIGHTS - PAVILION #8, 48G, 3/4" 20 1 1:5 1 20 SPARE 26 27 SPARE 20 1 1 20 SPARE 28 � � , , �ri��_ -� �.� -20- ^3' 1 20 SPARE 30 31 LIGHTS -GALLERY #12, #12G, 1/2" 20 1 ..8 1 20 SPARE 32 33 LIGHTS 119 #12, #12G, 1/2" 20 1 1.6 _ - ,20 -� ti--� 5 1 T 1 _ -, - - -� , #12,,#12G 2 20 —1 - - 1 20 ISPARE 36 37 LIGHTS -TERRACE #12, #12G, 1/2" 20 1 1.4 1 20 ISPARE 38 39 LIGHTS -TERRACE #12, #12G, 1/2" 20 1 1.4 1 20 ISPARE 40 1 20 ISPARE 42 PANELLOAD KVA AMPS NOTES: PHASE A 12.4 103 1,2 PHASE B 8.5 70 PHASE C 8 $ 73 TOTAL 29.7 82 @ 208V, 3 PHASE MOUNTING:. FLUSH PANEL P4A VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: SQ. D`NQ AMPS: 225 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO AIC RATING 10,000A CIR BREAKER LOAD HAS LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLEI SIZE WIRE/CONDUIT DESCRIPTION NUM 1 ROLL -IN REFRIG. (122) #12,#12G / 1/2" 20 1 1 X X X IX X X X X X X X X X X X X X X X XpqT 5 3 60 #6,#1OGLAW_BOOSTER HEATER (149) 2 3 REACH -IN FREEZER (123) #12,#12G / 1/2" 20 1 1.1 5 ) 4 5 HOPID LTS/CONTROLS (125) #12,#12G/ 1/2" 20 1 0.3 5 ) 6 7 HOOD EXH. FAN #12,#12G / 1/2" 20 3 1.1 5.5 3 60 #6,#10G / 3/4" "DISHWASHER (153) 8 9 ), 1.1 5.5 ) 10 11 ) a 1.1 5.5 ) 12 13 HOOP MUA FAN #12,#12G / 1/2" 20 3 ..6 0.8 3 20 412,#12G / 1/2" DISPOSER (149) 14 15 ) 0.6 0.8 ) 16 17 ) a 0.6 0.8 ) 18 19- GAS DUAL FRYER (126) #12,#12G / 1/2" 20 1 0.8 0.9 1 20 #12,#12G / 1/2" SODA SYSTEM (156) 20 21 I' SHUNTTRIP 1.5 1 20 #12,#12G./ 1/2" SODA DISPENSER (159) 22 23 " REFRIG. PIZZA PREP TBLE(133) #12,#12G / 1/2" 20 1 1.1 1.8 1 20 #121#12G / 1/2" BEVERAGE TABLE (162) 24 25 POS SYSTEM PRINTER (72) #12,#12G / 1/2" 20 1 0.3 1 20 SPARE 26 27 REFRIG: CHEF (130) #12,#12G / 1/2" 20 1 0.7 1 20 SPARE 28' 29 SHUNT TRIP 1 20 SPARE 30` 31 SPARE 20 1 =,X SPACE 32 33 SPARC` , 20 1 SPACE 34 35 SPARE 20 1 SPACE 36 37 SPARE , 20 1 SPACE 38 39 SPAR 20 1 SPACE 40 41 SPARE 20 1 ISPACE 42 PANELLOAD KVA AMPS NOTES: PHASE A 16 133 1,2,3 PHASE B 16.3 135 PHASE C 16.2 135 TOTAL 48.5 134 @ 208V, 3 PHASE X 65% DEMAND - 31.525 KVA SURFACE VOLTS &PHASE: 208/120V,3PHASE,4 1RE MOUNTING: SQDNQ PANELP3C AMPS: 2 25 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO ' AIC RATING 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE .SIZE WIRE/CONDUIT DESCRIPTION NUM 1 REC-TERRACE TV'S #1�, #12G, 1/2". 20 1 0.7 X X�.A-- X `/� X i X X `.. > X ( X '. X 1 X( X ' X X i X l 0.2 1 20 #8, #8G; 1" REC-EVENT LAWN 2 3 GALLERY DISPLAY TVs .." #12, #12G, 1/2" 20 1 0.5 -5-- GALLERY-DkSPLAY`TV&- 20- 0,5- 1 20 SPARE 6 7. REC-BAR TV'S #10, #10G, 1/2" 20 1 0.9 0.5 1 20 #10, #10G, 3/4" REC-ROOF TOP 8 9 MOTORIZED SERVILE DOOR #12, #12G,1/2" 20' 1. 0.5 1.5 1 20 #12, #12G, 1/2" HAND DRYER 10 `11 REC- 124 SERVICE #12 #12G, 1/2" 20. 1 0.2 1.5 1 20 #12, #12G, 1/2" HAND DRYER 12 �18` SP1iRE itif •�0 �_ 1�_ 1.5 1 20 #12, #12G, 1/2" HAND DRYER 14 15 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 16 17 SPARE 20' 1 1.5 1 20 #12,#12G,1/2" HAND DRYER 18 19 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 20 21 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 22 23 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 24 25 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 26 27 SPARE 20 1. 1.5 1 20 #12, #12G, 1/2" HAND DRYER 28 29 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 30 31 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 32 33 SPARE 20 1 1!5` 1 20 #12, #12G, 1/2" HAND DRYER 34 35' SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER. 36 37 SPACE 1.5 1 20 #12,#12G,1/2".HAND DRYER 38 39 SPACE 1.5 1 20 #12, #12G, 1/2" HAND DRYER 40 41 SPACE 2- PANEL LOAD KVA AMPS NOTES: PHASEA 9.8 81 1 PHASE B 10{2 85 PHASE C 8:1{��� 68 TOTAL 28:2 < 78 @ 208V, 3 PHASE i MOUNTING: FLUSH D NQ PANEL P4 B AMPS PHASE: 208/120V, 3 PHASE;4 W22 STYLE: SQ,. ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.LO: I-MLO") Al C RATING . 10,000A CIR $REAKER LOAD PHAS LOAD BREAKER CI R NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 GAS PIZZA OVEN (135) #1 ,#12G / 1/2" 20 1 0.1 X X X X X X X X X X X X X X X X X X X X 1.8 1 20 #12,#12G / 1/2" ICE TEA BREWER (164) 2 3 PIZZA OVEN VENT FAN (136) #12,#12G /1/2" 20 1 0.4 0.7 1 20 #12,#12G / 112" REFRIG. (165) 4 5 REF. SANDWICH UNIT (138) #12,#12G /:1/2" 20 1 0.7 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (166) 6 7 SOUP WELLS (140) #12,#12G / 1/2" 20. 1 _1.6 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (166) 8 9 WORK TOP REFRIG. (142) #12,#12G / 1/2" 20 1 1.1 1.8 1 20 #12,#12G / 1/2" POPCORN MAKER (185) 10 11 SOUP WELLS (140) #12,#12G/ 1/2" 20 1 0.8 0.2 1 20 #12,#12G / 1/2" REFRIG. (186) 12 13 SPARE 20 1 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (187) ," 14 15 SPARE' 20 1 0.8 1 20 #12,#12G / 1/2" HOT DOG ROLLER (188) 16 17 ICE MACH. (158) #12,#12G / 1/2" 20 1 1.4 0.5 1 20 #12,#12G / 1/2" BUN WARMER (189) 18 19 WI NE CHILLER (175) #12,#12G / 1/2" 20 1 OA 0.7 1 : - 20 #12,#12G / 1/2" DRAFT BEER COOLER (178) 20 21 BACKBAR COOLER (176).. #12,#12G / 1/2" 20 1 0.7'. 1.3 1, 20 #12,#12G / 1/2" GLASSWASHER (181) 22 23 GLASS CHILLER(177) #12,#12G / 1/2" 20 1 0.7 0.6 1 20 #12,#12G / 1/2"POS(82) 24 25 BOOSTER HEATER (180) #8,#10G / 3/4" 40 3 3.3 0.7 1 20, #12,#12G / 1/2" REC-BAR 26 27. ).. 3.3 1 20 SPARE 28 29 ) 3.3 1 20 SPARE 30 31 REC-BAR #12,#12G / 1/2" 20 1 0.4 1 20 SPARE 32 &,fC-KITCHEN422, ,-- ,—,,,- .1/2 ,-1 5 1 : 20 SPARE 34 35 WH-P7A #10, #IOG, 3/4" 30 2 2.4 1 20 _ SPARE 36 37 ) 2.4 1 20 SPARE 38 39 1--' '0.i SPACE --_-_ 40 41 ISPACE 1 SPACE 42 PANELLOAD KVA AMPS NOTES: PHASE A 15 125 1,2,3 PHASE B 10.7 89 PHASE C 12.4 103 TOTAL 38.1 105 @ 208V, 3 PHASE X 65%n DEMAND = 24.765 KVA m rm Z az E C o C) LLI fN W LLI 0 0 I o Qz THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. U� V1 ct w x TTom; Qy 1�1 Q:) liwif BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com i Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E602