HomeMy WebLinkAboutField Density Tests of Compacted SoilsFEDERAL
ENGINEERING &TESTING
1798'.AM1,;% CIRCLE S.E. SUITE 5 250 S.W. 13TH AVENUE
PALM BAY, FLORIDA 32909 POMPANO BEACH, FLORIDA 33069
FIELD DENSITY TESTS OF COMPACTED SOILS l/
DATE: 07/01/04 ORDER NO: 04-4730 PERMIT NO.
CLIENT: B & D GRADING INC.
ADDRESS: 2790 COOLIDGE ROAD FORT PIERCE, FLORIDA 34945
PROJECT: PROPOSED RESTROOM BUILDING PAD THE PRESERVE, SPYGLASS
ADDRESS: BALLI BUNION ST. LUCIE COUNTY FLORIDA
MATERIAL DESCRIPTION: BROWN SILICA SAND W/SOME CLAY & TRACES OF SHELL FRAGS
LOCATION.
LOCATION
LOCATION
LOCATION
LOCATION
LOCATION:
N.E. CORNER OF PAD
A
S.W. CORNER OF PAD
uu
S.E. CORNER OF PAD
f
ci® County Public Works
FIELD DENSITY METHOD A.S.T.M. D-2922
DRY DENSITY P.C.F. IN THE FIELD
108.3
109.0
108.3
MOISTURE
9.0
8.2
8.5
% COMPACTION IN THE FIELD
98.6
99.2
98.6
% COMPACTION REQUIREMENT BY SPECS
95%
PROCTOR VALUE, P.C.F.
109.9
OPTIMUM MOISTURE, %
10.1
LABORATORY NO.
P4611
DEPTH IN INCHES
12
PROCTOR A.S.T.M D-1557 METHOD
ALL TEST RESULTS COMPLY WITH SPECIFICATIONS UNLESS OTHERWISE NOTED WITH AN ASTERISK(*).
REMARKS: SOEL NOT TESTED BELOW FOOTINGS
_
• `, tip; - '
TESTED BY: SL
Resprrectf��ully submitted, -
�; s• Sdi./�'I"
CHECKED BY: KM
1/�`
- SAM S. NA P.E.
As a mutual protection to clients, the public and ourselves, all reports
FEDERAUENGINEERING &"TESTING
are submitted as the confidential property of clients, and authorization
FLORIDA REG. Y39584
for publication of statements, conclusions or extracts from or regarding
our reports is reserved pending our written approval.