Loading...
HomeMy WebLinkAboutField Density Tests of Compacted SoilsFEDERAL ENGINEERING &TESTING 1798'.AM1,;% CIRCLE S.E. SUITE 5 250 S.W. 13TH AVENUE PALM BAY, FLORIDA 32909 POMPANO BEACH, FLORIDA 33069 FIELD DENSITY TESTS OF COMPACTED SOILS l/ DATE: 07/01/04 ORDER NO: 04-4730 PERMIT NO. CLIENT: B & D GRADING INC. ADDRESS: 2790 COOLIDGE ROAD FORT PIERCE, FLORIDA 34945 PROJECT: PROPOSED RESTROOM BUILDING PAD THE PRESERVE, SPYGLASS ADDRESS: BALLI BUNION ST. LUCIE COUNTY FLORIDA MATERIAL DESCRIPTION: BROWN SILICA SAND W/SOME CLAY & TRACES OF SHELL FRAGS LOCATION. LOCATION LOCATION LOCATION LOCATION LOCATION: N.E. CORNER OF PAD A S.W. CORNER OF PAD uu S.E. CORNER OF PAD f ci® County Public Works FIELD DENSITY METHOD A.S.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD 108.3 109.0 108.3 MOISTURE 9.0 8.2 8.5 % COMPACTION IN THE FIELD 98.6 99.2 98.6 % COMPACTION REQUIREMENT BY SPECS 95% PROCTOR VALUE, P.C.F. 109.9 OPTIMUM MOISTURE, % 10.1 LABORATORY NO. P4611 DEPTH IN INCHES 12 PROCTOR A.S.T.M D-1557 METHOD ALL TEST RESULTS COMPLY WITH SPECIFICATIONS UNLESS OTHERWISE NOTED WITH AN ASTERISK(*). REMARKS: SOEL NOT TESTED BELOW FOOTINGS _ • `, tip; - ' TESTED BY: SL Resprrectf��ully submitted, - �; s• Sdi./�'I" CHECKED BY: KM 1/�` - SAM S. NA P.E. As a mutual protection to clients, the public and ourselves, all reports FEDERAUENGINEERING &"TESTING are submitted as the confidential property of clients, and authorization FLORIDA REG. Y39584 for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval.