Loading...
HomeMy WebLinkAboutRevisions; Removed Window in dining room and added window to master bathroomOFFICE USE ONLY: DATE FILED: • ' -� • , 1 REVISION FEE: PERMIT # 1904-0094 RECEIPT # I �S"4 (.d PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION RECEIVED 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 AUG 13 2019 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS ST° Lucie County, Permitting PROJECT INFORMATION LOCATION/SITE ADDRESS: 131 Ocean Estates Drive, Fort Pierce, FL 34949 DETAILED DESCRIPTION OF PROJECT REVISIONS: Removed window in dining room and added window in master bathroom CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGCO24829 ST. LUCIE CO CERT. #: 29976 BUSINESS NAME: TRM Construction Manaqement QUALIFIERS NAME: Thomas Rickert Miller ADDRESS: 1512 SE Village Green Drive CITY: Port St Lucie STATE: FL ZIP: 34952 PHONE (DAYTIME): 772.905.2727 FAX: 772.237.3081 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: Farid Abuqattas, P.E. ADDRESS: 7318 Texas Trail CITY: Boca Raton STATE: FL ZIP: 33487 PHONE (DAYTIME): 954.667.7803' SLCCC: 9123109 Revised 06130117 FAX: 561.665.5438 t y ! '%'ff REW"VISION F C ; t T r W / Vt ()l� I- PVC 'Glass Block Supp/, -, it C^ Phone: (386) 676-07 70 -e F aat: (886) 676- 0.787 ivww. GlassB1ockSupp 1yL.LC. com MIAMMAM MLAMI-DADS COUNTY , _ PRODUCT CONTROL SECTION SW 26 Street, Room 208 !DEPARTMENT OF REGULATORYAND ECO1dOBaC RES CES Earn, Florida 33175-2474 BOARDAND CODE ADMINISTRATION DIVISION 590 F(786)315-2599 ng NOTICJE OF ACCEPTANCE (NOA)iamidade. ovlecenomv Seves Glass Block, Inc. I � Lucie County, permittingJ 10576 Broadview Road Broadview Heights, OH 44147 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHD (in areas other than Miami Dade County) reserve the right to have. this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material. fails to meet the requirements of the applicable building code, This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Residential Hurricane Resistant Windows with THICKSEr 90 Series Glass Block and ProVantageO Silicone System APPROVAL IDOCUTMiENT: Drawing No. RFIRW-001, titled "Residential Hurricane Resistant Windows with THICKSET' 90 Series Glass Block and ProVantagex Silicone System", sheets 1 through 3 of 3, dated 11 /17/2015, prepared by the manufacturer, signed and sealed by Hermes F. Norero, P.E. on 12/19/2017, bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a pennanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERTMINALTION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #I5-1201.12 and consists of this page 1 and evidence pages E-1 and P,2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. lUtrera, P.E. NOA No. 17-0821.14 rauMwAaewUNTWY Expiration Date: December 1, 2020 Approval Date: February 8, 2018 41 f _3 ool g Page I Seves Glass Block. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITT'E1D 1. Evidence submitted under previous NOA's A. DRAWINGS "Submitted under IVOA # 1i-1201.12' 1. Drawing No. RHRW-001, titled "Residential Hurricane Resistant Windows with TIRCKS.ET° 90 Series Glass Block and KWIK'N EZ Silicone System", sheets 1 through 3 of 3, dated 1111712015, prepared bythe manufacturer, signed and sealed by Hermes F. Norero, P.B. B. TESTS "Submitted under NOA # 15-1201.12" i. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC, TAS 202-94 along with marked -up drawings and installation diagram of Residential Hurricane Resistant Windows with THICKSET 90 glass block and KWIK'N EZ Silicone System", prepared by Intertek/Architectural Testing, Inc., Test Report No. F0556.01-501.18, dated 11117/2015, signed and sealed by Joseph A. Reed, P.E. "Submitted under NOA # 04-0301.01 " 2. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Seriesll odel S" x 8" x 4" THICKSET 90 glass block assembly", prepared by Architectural Testing, Inc., Test Report No. 01-44639.03, dated 12102/2003, signed and sealed by Joseph A. Reed, P.E. C. CALCULATIONS "Submitted under NOA # 15-1201.12" 1. Anchor calculations prepared by Building Drops, Inc., dated 12/08/2015, signed and sealed by Hermes F. Norero, P.E. "Submitted under NOA # 12-0406 05" 2. Anchor calculations prepared by Building Drops, Inc., dated 04/03/2012, signed and sealed by Hermes F. Norero, P.E. "Submitted under NOA # 04-0301.01 " 3. Calculations prepared by Engineering Analytics, Inc, sheets 1 through 4, of Thickset Series Fasteners, dated 05/0212005. signed and sealed by Carol D. Hays, P.E. Ol !��lt3 Carlos 11'L Utrera, P.E. Product Control Examiner NOA No. 17-0821.14 Expiration Date: December 1, 2020 Approval Date: February 8, 2018 E -1 Seves Glass Block, lac. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0909.11, issued to Cardinal Systems, Inc., for their Rigid PVC Extrusions for Glass Black, approved on 12/I 1/2014 and expiring on 12,101/2020. F. STATEMENTS "Submitted under NOA 4 I5-1201.12" 1. Statement letter of code conformance to the 5d' edition (2014) of the FBC and of no financial interest, issued by Building Drops, dated 12108/201 S, signed and sealed by Hermes F. Norero, P.E. "Submitted under NOA # 12-0406 05" 2. Statement letter of code conformance to 2010 FBC and no financial interest, issued by Building Drops, dated 04/0312012, signed and sealed by Hermes F. Norero, P.E. 2. New evidence submitted A. DRAWINGS 1. Drawing No. RHRW-001, titled "Residential Hurricane Resistant Windows with THICKSET' 90 Series Glass Block and ProVamageC6' Siticone System", sheets I through 3 of 3, dated 1111712015, prepared by the manufacturer, signed and sealed by Hermes F. Norero, P.E. on 12/1912017. B. TESTS 1. None. C. CALCULATIONS 1. Product Evaluation Report No. 4742, prepared by Building Drops, dated 04/1212017, signed and sealed by Hermes F. Norero, P.E. D. QUALITY ASSURANNCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTMCATIONS 1. None. F. STATE'_V.iENTS 1. Statement letter of code conformance to the 61' Edition (2017) FBC issued by Building Drops, dated 12,115/2017, signed and sealed by Hermes F. Norero, P.E. 2. Testing schedule letter issued by Intertek, dated 12/08/2017, signed by Vicki L. McElwain. 3. Agreement and bill of sale dated 080-4/2016. is 4. Declaration of the ownership dated 12/01/2016. �4 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 17-0821.1 d Expiration Date: December 1, 2020 Approval Date: February 8, 2018 E-2 SEVES GLASS BLOCK RKIID PVC PLASTIC CHWEL STRUCTURE' pPLAN6x8x4 SttNES GLASS BLOCK STRUCTURE' THICKSEi90 4 s-0 uacLlnnA SECTION NOMINAL IYIOTH ELEVATION N1PACrRESISTANT DESIGN PRESSURE RATING 6 BLOCKS x 6 BLOCKS t 1010 PSF ' SffAFKA1DRSCI UE SILE(T7. PLAN — SEVESGLASSBLOCK ROID PVC PUSTICCriWNEL 84K4 SEVES GLASS BLOCK 7RCKSET90 64,4 SEVES GLASS BLOCK THICKSET 97 STRUCTURE• - PEMETERFRNANG SEuP TLOCATMS GLASS BLOCI)MJT SEALANT LOCATIONS RIGIDVVGPLASW—, L:WddEL PRE-PUNCIIED 1018 FOR ANCHWfJG TO SUBS IRATE REM31CN5 DESCRIPTIDI: DATE f-(rW ciAUG I NDIAINAL YJIDIH SECTION ELEVATION 411FACTREMMMA7 6 BLOCKS x 12 BLOCKS DE&GH PRESSURE RATPIO 1 BCA PSF -- PoGrJ PVCPi,�.S'Ti:: SF`A�3t r�u r:,,,, Residential Hurricane Resistant Windows 4T„11 .�`��� With THICKSETO 90 Series Glass Block PRODUCT REVISED WIIb 0. "MCa ' ✓s And ProVaniage9 Silicone System P1�ETM FRAMING SE4IMTLOCATIORS (lElr3TILCfG+JsaktS ;:W—:p1) ; aau4a 17-0821.14 _ v expentgo D. r .��,G 73778 Tk SEVFS GLASS BLOCK, INC. i 91710172DR0 _ O� OF 10576 BROApV(EW ROAD L . Rlnp BROADVIEW HEIGHTS, OH 44147 IMF W4 iairau rvx •' LtAS o+re 1111712015 10F3 _ - - rzEVlsioNs ANDIOR LOCATIDN (ANCHDRS ARE STAGXMC F{ pwCPLASTIC SPACER REV DESCR[PT7oN DATE STRUC"ttRe'*WCK— (SEE81i' D.C.) Si7CCciESFAlAN(, — __�_� a TYR SNCONE SEALANT,Z= °J TYP._ - ANCHOR LOCATION S(1COtIESFALNti, nun SEV2SG1AS5BLOCK mSTDE) Typ. nBCI(SLTBO SILICONE SEALANT, Slucor�sFaLwlr, aTm. rrPRRYDPVC PLASTIC "AEL Y' RIGID wC RASnC OLANNEL'OMEL AT HEAD TRICK DETAt� SUCDNESEALANT, - TYP. SILICONE Sawa, I BcBt4SEVESGIASSBLOCK TV, THICKSET90SILIC- PIlETER CHANNEL, ATFEAQ TO BE CUT QYf SEALANT, $„ $ ERILEWWMSE DM%W 7Iff CENTER FOR INSTALLATION SILICONE SEALANT, S•RUCIURE' ANCHOR lOCA110N OF LAST ROW Of GJJBLOCK BLOK n,� RIGIDPvcPv�sncsPACFtI TYPICAL SILLdETA�L• (ANCHORSA2ESTAGGEREA HALF GiANH°L FIECt: THAT IS SF.Ctll7F.D V!!Ti 1 'SEE ANCHOR SCHEDULE, SHEET 3. 1 1 SCAE:3'-i'-O' WO.C.) .SCAEJIS•SIkJLRDMONT14EEXTRiORSIDE. TYPICAL HEAD DETAIL SCN.E: 9' 1'd° - >;' SHIMSPACFj . • = - }: BEAD OF SEALANTAPPU:D HORIZONTALLY _•-`9®uCSEVESGLPSS'OLOGC SNWNE.SEALANT. HALVES. ACfTOS9TItETOP INSIDE CORNERS OFLYUI7NEl 3155 DIIC(SETSO StI�1�CONESF�i`ANT,'; TIP. 0.175 . 0.160: SfUM E SEN.ANT - . • 3 IYP• s7kucrLPiE •_ CHANNEL AT HEAD DETAIL I SCAF: Iw=P .� NOTE:TYPiCALWALLTHICKNESS=O.O:fb �"i --' .•i r - _, x HIGIDFJCPLASTw t. Ai(GifORLOAiIQY(ANCHORS •-+ t ' PVC SPACER (NC.QP 0514� , SPACER = '<� ARsraccaosy; oc) CAPM-1 SYSrEMM SCALE I:ITYPICAL•JAMBDETAIL r— R.�IDPVCT7AsnccxAtAlEl atss _ J5T5 (-•. •- .µ ,,..c .. •: t -.1 RE91gn(O Hurricane Resistbrrt winnows Q UVitTHicKSET6.90•SerieJsspot (� PRODUCT REVISED ?ST i s �I JL�. _ _ � ° �� � •�,�' �•,- �' �`� • �� An'� l�bVatltage�l $ilicon�e�yslem V . L�.—___'_ NaL+w. •IxoBzt.la ' T} • J •1778.: o _ l � s: air:crop 1?Jo1JY020 = v ? �i a T sEvgs GLA S BLOCLC I C. 4.125 I ; :i V = OF ! r>• i�5T6 BRQADVIEW 9AfAD c ` - L W P; '��,� _DR Aqf JEW HEIGHTS, H 44� i t7 PVC CHANNEL (N0. QP-0477) = =—' ' �i�fio • �:"• ���� icua , • ortt.n• !i CAIDRLLSYSTEW INC. •;' I ? ,>re �Ti 9gRFcS RF1RI'-ODI j O SCALE t:l t ' uc �.n,cm ° Jj$:; nnnT%.. 11N711D15 p OF 3 f 2 fz Imo, t7 { rri ..� ... � fI: 1'..' 4✓ :.a it #5 DOWEL BAR DRILLED AND EPDXIED 6" INTO POURED FOUNDATION CAN SUBSTITUTE HOOKED DOWEL FILLED CELL REINFORCEMENT SEE PLAN FOR SPACING AND COLUMN FILLED CELL REINFORCEMENT SCHEDULE FOR DIAMETER RAISE CURB TO SEE PLAN FOR SPACING AND COLUMN SCHEDULE FOR DIAMETER MATCH MAIN HOUSE CMU WALL W/ #9 LADDER TYPE 1-1/2" CMU WALL W/ #9 LADDER TYPE FINISHED FLOOR. REINF. EVERY OTHER COURSE BLOCK RECESS REINF. EVERY OTHER COURSE PROVIDE 1#5 CONT AS #4 TRANFER BARS (ONLY IF REQUIRED POURED CONCRETE EQUIPMENT SLAB. SHOWN. ❑ #4 TRANFER BARS (ONLY IF REQUIRED o BY FOOTING SCHEDULE) SEE PLAN VEIW FORACTUAL w BY FOOTING SCHEDULE) REINFORCEMENT AND THICKNESS 0 4" THICK CONC. SLAB W/ (1) LAYER OF w 4" THICK GONG. SLAB W/ (1) LAYER OF : GRADE Z m W1.4 X WIA - 6/6 WWM (OVERLAPPED @ PERIM) ED PERIM -. 1.4 6/6WWM (OVERLAPPED ) — W1.4XW @ '�. g ¢ Ak T.O.S -2 ~ N F SEE ARCH z SEEPLAT a w _ d. SEE PLA a `v a l f uj w w I, p w F > :. � I • • :' 6" LAPPED AND TAPED I ':. I � .— 6' LAPPED ANDTAPED JJJ I, -- 6 MIL. V.B. OVER - �:j w COMPACTED TERMITE ? COMPACTED TERMITE I �,�, ,a� j TREATED SOIL I CONT. REINF. - 1 _ _ _ _ �.l N W TREATED SOIL i PER FOOTING SEE SCHED. v CONT. REINF: SEE SCHED. p - 2 Q U I P M E NT AD SCHEDULE N PER FOOTING m SCHEDULE w N S1 SCALE: 3/4° = 1'7 LOWER AREA CURB: WATER 1 EXTERIOR BEARING WALL 3 ARRIE/4 S 1 SCALE: 3/4" = 1' S 1 SCALE: 3/4" = 1' COLUMN,SEE W I A X W L4 - 6/6 W W M FOUNDATION: PLAN. GRADE OIL T.O.S .SEE PLAN �i 6" LAPPED AND TAPED ------� — -- 6 MIL. V.B. OVER ; COMPACTED TERMITE ' • • ` • TREATED SOIL —. - CONT. REINF. .SEE — PER FOOTING SCHEDULE J,, i 4 SECTION S 1 SCALE: 3/4" = 1' SYMBOLLEGEND SYMBOL DESCRIPTION 4@6B-INNER 4@6T-INNER 4@6T-OUTER 46613-OUTER STEEL REINFORCEMENT 4@6 : #4.'s @6" O/C ; B : -: BOTTOM '. f- -T: TOP -OUTER: OUTERMOST LAYER -INNER: INNERMOST LAYER -TEMP: TEMPERATURE AND SHRINKAGE REINF. SECTION MARK- DETAIL NUMBER / SHEET NUMBER S1 ROOF RIDGE LINES FLOOR STEP Ct STEEL COLUMN ABOVE FLOOR LEVEL C1 STEEL COLUMN BELOW FLOOR LEVEL c1 c1 STEEL COLUMN ABOVE AND BELOW FLOOR LEVEL P1 CONCRETE PAD FOOTING -SEE FOOTING SCHEDULE Q-� REVISION NUMBER- SEE TITLE BLOCK FOR DATE 0 REVISION CLOUD pOVE ■BELOW O AB STEEL COLUMN JOISTS OR TRUSSES - SEE SHOP DRAWINGS --� PARTITION ® ABOVE BELOW O CONCRETE COLUMN - SEE GONG. COL SCHED, R FILLED CELL - SEE GONG. COL. SCHED. Inniggificil= CMU WALL CURRENT LEVEL CMU WALL ONE LEVEL BELOW - WOOD FuII "-lllwl �IJ I SOIL a a - NEW CONCRETE SLAB 0 _ :NEW CONCRETE BEAM NEW CONCRETE FOOTING P• v,e a WELD SYMBOLS a a TIE BEAM TRANSITION SYMBOLS + + UPLIFT FORCES & CONNECTORS - SEE STRAP SCHED. ELEVATION MARKER - SEE ARCH PLANS FOR+0'-0" +55.06 88.88 WIND PRESSURES ON OPENINGS (GIVEN IN PSF) CONCRETE WALL VERTICAL REINFORCEMENT. SEE FOUNDATION / FRAMING PLANS FOR LOCATIONS THICK DASHED LINE REPRESENTS OPENING ON STORY BELOW REINFORCED MASONRY WALL B840 T(a)14'-0'j CONCRETE BEAM, 8" WIDE x 40" DEEP, TOP @ +14'-0" SEE BEAM SECTION OR PROFILE FOR REINFORCEMENT LOADING THIS LEVEL FIRST FLOOR - INTERIOR (138 PSF) DEAD (77 PSF) FLOOR SELF WEIGHT= 50 PSF FLOOR FINISHES = 27 PSF LIVE (55 PSF) OCCUPANCY = 40 PSF PARTITIONS:ASCE7-10: 4.3.2 = 15 PSF FIRST FLOOR - EXTERIOR (177 PSF) DEAD (77 PSF) FLOOR SELF WEIGHT= 50 PSF FLOOR FINISHES = 27 PSF LIVE (100 PSF) OCCUPANCY =100 PSF STAIR TOTAL LOAD (110 PSF) DEAD (70 PSF) SELF WEIGHT = 26 PSF FLOORING = 25 PSF COVERINGS =4 PSF RAILINGS = 15 LIVE (40 PSF) SINGLE FAMILY OCCUPANCY LIVE =40 PSF ® i�BU��, No7247\1 Z. 8/2/2019 STEEL PLATE SCHEDULE PLATE SUBSTRATE ANCHORS SIZE MATERIAL R 10 x 10 CONCRETE (4) 3/4"OXB" HEADED STUDS (SQUARE) R 7 x 10 CONCRETE (3) 3/4"Ox8" HEADED STUDS (INLINE) Ill 7 x 7 CONCRETE (2) 3/4"Ox8" HEADED STUDS (INLINE) E 7x 10 STEEL (2) 1/4"x8" FILLET WELDSI(MIN LENGTH) CONNECTING COLUMN PLATE AND STEEL BEAM FLANGE -ALL STEEL COLUMN CONNECTIONS TO TOP AND BASE PLATES TO HAVE A 3/16" THICK FILLET WELD ALL AROUND -STEEL COLUMN THICKNESS MAY BE INCREASED IF AVAILABILITY OF MATERIALS REQUIRES IT (MAINTAIN OUTSIDE DIMENSIONS CONSTANT). NOTE: HEADED STUDS MAY BE SUBSTITUTED FOR EXPANSION BOLTS ONLY WHEN ATTACHING TO A FOOTING, GRADE BEAM OR PILE CAP. -UNLESS SPECIFICALLY NOTED OTHERWISE ON A DETAIL OR PLAN VIEW, STEEL COLUMN PLATE HEADED STUDS MAY BE SUBSTITUTED BY EQUAL DIAMETER AND LENGTH EXPANSION BOLTS. PROJECT CLASSIC Structural EngineerinIz REVISIONS BY FARID ABUGATTAS, P.E. 71REV F.A. STRUCTURAL ENGINEER 2 REV- F.A. 7318 TEXAS TRAIL BOCA RATON, FLORIDA 33487 PHONE: (954) 667 - 7803 FAX: (561) 665 - 5438 P.E. LICENSE # 72471, CA#29407 — _-- WWW.PROJECTCLASSIC.COM PROJECT# --- FARID@PROJECTCLASSIC.COM 4759 MONOLITHIC FOOTING SCHEDULE _ REINFORCEMENT DIAMETER AND COUNT = a SHORT WAY LONG WAY CODE 3 p ADDITIONAL REQUIREMENTS LIGHT STRUCTURE SUPPOT MF-16 16" 16, # 4's @ 36 O/C BOTTOM 2 # 5's BOTTOM NO TRANSFER BARS REQURRED MF-20 20" 16" #4's @ 36" O/C BOTTOM 2 # 5's BOTTOM NO TRANSFER BARS REQUIRED MF-24T5 24" 16" # 4's @ 36" O/C BOTTOM 3 # 5's BOTTOM #4's x 6 @12" O/C LONG TRANSFER BARS. FOOTING SCHEDULE x w U REINFORCEMENT DIAMETER AND COUNT z SHORT WAY LONG WAY CODE. o pp ADDITIONAL REQUIREMENTS WQ P33 3 3' 12' 12" (4) # 5's BOTTOM (4) # 5's BOTTOM - P35 3 5'. 12" 12" (6) # 5's BOTTOM (4) # 5's BOTTOM - P44 4' 4' 92" 12" (5) # 5's BOTTOM (5) # 6's BOTTOM - P55 5 5' 12" 12" (6) # 5's BOTTOM (6) # 5's BOTTOM - 10 T C QA C830 16 I 1 16 TRENCH DRAIN. S4 S1 S5 SEE ARCH PLANS 10 24'-4" 3 24' 14'-10" - — — „ : „ �, ;_ „ " 2,-g" — 2`"— -'!'_ 1,_8,..: 1 CUT LOCK REINFORCE WITH '4' 2'-8" 1'-9-2' 3'-62' 2'•8" 2'-B" 2'-S" 2'4' 2'-8" _Z 2-6 2- 2 8 2-8 2-8 2-8 2 8.. 2 8 2#6 ERTICALANDFORMOUTER FAC FILL WITH GROUT. r------------------ -- — — — — — — — _—r+51.16 1 -- -55.50 � MF-20:. o _, �. 3 MF-20 d I M812 HER'W.I.C. — — 1 2„ /STRUCTUR I C824 LITILIT T a S1 21,3„ 3 S1 ' RCH I I 4"THI GOING. SLA61W/(1)LAYERPFW1.4XW1.46/6 gcp W.W.M. (TO BE LOCATED j FROM`jHE TOP OF THE5SLAB S1 - & SHALL BE SUPPORTED BY APPROVED MATERIALS O� 10 S / G U SUPPORTS NOT TO EXCEED T-0" O/C EACH WAY) OR I' S4 S4 MASTER BEDROOM I MAST' R BATHROOM a FIBERMESH ON 6 MIL VAPOR BARRIER OVER TERMITE TREATED VELL COMPACTED FILL aLL 1 . 1 3 '.61" SS:3-1/2x3-1/2xl/ F'c=2,500 PSI 4 a a 31,__1. 52 PL I0x10x5/8 L r�, ,w'+§ra ^?-..r?..: ,,.ri„ . �v ;._^k.,�'#e'�.. 3fl'{.:roC'YM :.,. • N .�.. .... >z I I 4 , ., f � , •. � j SEE BUCK AND SILL TYPICAL DETAILS: 3/S5,4/S5,6,IS5.. x •> �,. (� CONCRETE &CMU COLUMN SCHEDULE COORDINATE COLUMN EDGE LOCATION WITH THE ARCHITECTURALS AND WITH THE DOORNVINDOW SUPPLIER- I ( M812 3 S4 L fl �fl ❑^` _ „ � 11 — 54. - ,._ . S4- —: 3.112x3-1/2x g / rRucruR 5 KITCHEN S 4 5 - 'a S UC TUR S "" 7 ,;, _0,_6, S4 a$4. L SS 3-1/2x3-1/2x3/ a PL 1ox1ox34 a, d w �. 3 a T PAVEcRSDN-SAND 2 ❑ - 8"x8" FORMED COL. OR CMU COL. M5 _ R 30" LAPS � w/ (1) # 5 REINF. BA ( ) SEE FNDN & FRMNG PLAN FOR LOCATIONS FILL w/ GROUT - SEE STRUCTURAL NOTES. 8"x8" REINFORCED MASONRY COL. w/ (2) # 5 REINF. BAR (30" LAPS) M5.2 SEE FNDN &FRMNG PLANFOR LOCATIONS FILL w/ GROUT - SEE STRUCTURAL NOTES. SEE DETAIL 9/S7 8"x8" REINFORCED MASONRY COL. ® w/ (2) # 6 REINF. BAR (36" LAPS) M6.2 SEE FNDN & FRMNG PLAN FOR LOCATIONS FILL w/ GROUT -SEE STRUCTURAL NOTES. 8"x12" FORMED COL. OR CMU FILLED CELL M812 COLw/ (2)#6 REINF.. BAR SEE PLAN FOR LOCATIONS SPACING FILL W/ GROUT - SEE STRUCTURAL NOTES. 12"XI2" FORMED COL. OR CMU M1212 ❑ COL. w/ (4)#5'S VERT. FILL w/ GROUT - SEE STRUCTURAL NOTES. w/ #3 TIES @ 10" O/C 12N12" FORMED COL. OR CMU M1212-1 COL. w/ (8)#6'S VERT. FILL w/ GROUT - SEE STRUCTURAL NOTES. w/ #3 TIES @ 6" O/C 16"xl6"FORMED COL. OR CMU COL. w/ (4#6'S VERT. ❑ M1616 FILL w/ GROUT - SEE STRUCTURAL NOTES. w/#3TIES @10".O/C 8"x12" POURED GONG. COL. C812 ® w/ (4) #5's VERT. w/ #3 TIES @ 8" O/C 8"x24" POURED C NC. COL. F� w/ (6) #5's VERT. C824 w/ #3 TIES @ 8" O/C w/ #3 HOOKS @ 8 O/C 8"x30" POURED GONG. COL. C830 ® w/ (8) #5's VERT w/ #3 TIES @ 8 O/C w/ #3 HOOKS @ 8"O/C POURED GONG. COL. C1 �`N/ (8) #5's VERT. 2 SETS OF #3 TIES @ 8" O/C SEE DETAIL 7/S7 POURED GONG. COL. C2 w/ (8) #5's VERT. ;. + 2 SETS OF #3 TIES @ 8" O/C SEE DETAIL 8/S7 POURED GONG COL. C3 C1 k'/ (6) #5's VERT. 2 SETS OF #3 TIES @ 8" O/C SEE DETAIL 7/S2 POURED GONG. COL. rC4m w/ (6) #5's VERT. 2 SETS OF #3 TIES .@ 8" O/C SEE DETAIL 8/S2 1 - - ' � `.. S4 8.. 7 TYPICAL ORALL OOR vy.I. ,'' . BREAKF SLAB W/ 1 LAYER OF W1.4X W1.46/6 4 THICK CONC. O S4 S4 SEE DET IL 5/S 5 W.W.M. (TO. BE LOCATED 4 FROM THE TOP OF THE M812 SLAB & SH L BE SUPPORTED BY APPROVED — — a �11'-5". 4'.,4" — — '-6„ _qr MATERIAL OR SUPPORTS NOT TO EXCEED 3'-0" O/C r , EACH WAY OR FIBERMESH ON 6 MIL VAPOR BARRIER �. ' A -I OVER TERMITE ., a 3 In o N TREATED WELL COMPACTED FILL .. w F'c=2,500 P � � `o � I ry SS 3.11/2x3-1/2x1/ L— _ J r I #4 x T-O" LONG L _ — J pi 10x10x5/8 Cv L - — a L_ _, — /STRUCTUR F OTING CRACK CONTROL 13 -e✓ER D E. T I REINFORCEMENT 3 S4.- E FC1Y R V. v°' ' M81 @ MID OF SLAB (TYP.) 4 6 (ALL FIRST FLOOR CORNERS) S4 7 4' 4" 3 3 Ql S4 — — r — — Via'-1o° a S1 S2 - 3 �-- :. s ... �- ----� C2 '•g3-9/2�=i/2z1 —. I I 4 — II ❑❑ ,❑❑❑ N M -20 — J 5 c4 PL 1Dx10x5/8 L a 6 4 L— _J L— ,_J — --"- 1 10'.4" ":: ❑❑ ❑❑❑- ❑❑- ❑❑ M 0 z ELEV. , io r:1, ,... ,_ ,; „ �,_g 11 7 4" THICK CONC. SLAB W/ (1) LAYER OF W1.4 X 14 8 1 8 S4 N S4 , W1.4 6/6 W.W.M. (TO BE LOCATED -1 FROM THE 1 - r — — -1 r — — —,71 -.OFFICE/L.IB TOP OF THE SLAB & SHALL BE SUPPORTED BY m RTS NOT MATERIALS OR SUPPO J APPROVED MA r 11 g SS 3-1/2x3-1/2x1/ I F SS 3-1/2z3- /2x1/ w iv N TO EXCEED 3'-0" O/C EACH WAY) OR FIBERMESH ON N I 9 S4 PL 10x10x5/8 PL 10x10 5/8 L. - —. J. L S4 3 3 O ls� �ovi5 BATH N°D TUR 4x4 WOOD POS347 �� SEE BUCK AND SILL TYPICAL ' g +p�.0'� W/(2)2x12 HEAD R 4 3, �,,. 11 10 14, I— DETAILS: 3/S5, 4lS5, 6/S5 e2 _N -to 3 S2 LL o Z I C3 IwoZ coi mil S1 qa a 12 CI m C812 Y v� + _ __ S 47.29 - 4 v S7 —7 If ❑ ❑ ❑ ;fl❑ ❑❑❑ ❑❑ ❑❑❑ ❑❑ ❑❑ ❑❑L7 ❑❑❑ ❑❑❑ Ca ❑ � ❑❑ _ 0 4,_6„ 8„ 2,-0„ 24- 2I_S„ 2,_8,� 1'.T, 1, 3,_1"L ,�,,. 2,_8„ 2'-8" 2,_8 2_8" 2,_8 2r_4„ 30'. m 4116" 16 RECEIVED S4 C812 j1 C812 I AUG 18 2019 16 1 S4 12' 3 7,7 3 EQUIPMENT PAD: EQUIPMENT PAD: 8'-4" 2, 6" ST. Lucie County, Permitting B C 6" CONCRETE SLAB. SEE : 6" CONCRETE SLAB. SEE SEE BUCK AND SILL TYPICAL ARCH ITECTURALS FOR TOP 2 ARCHITECTURALS FOR TOP D = DETAILS: 3/S5, 4/S5, 6/S5 ELEVATION, ELEVATION. REINFORCE W/ # 3's @ 12" O/C S1 REINFORCE W/ # Ts @ 12" O/C FOUNDATION OI I I� I D /� 2 AND - EACH WAY MIDDLE. PROVIDE EACH WAY MIDDLE. PROVIDE 1— U N AT I O N A (1) # 4 CONTINUOUS ALONG (1)#4CONTINUOUS ALONG S1 FIRST FLOOR COLUMN PLAN - THICKENED EDOi=• THICKENED EDGE. SEE SOILS REPORT FOR SEE SOILS REPORT FOR — COMPACTION SPECIFICATIONS. COMPACTION SPECIFICATIONS. C � o' z 4' 6' 7 � VERIFY ACTUAL P _1 �, IMENSIONS WITH VERIFY ACTUAL DIMENSIONS WITH MANUFACTUREMANUFACTURER 6 R 'I LiiiiiIiiIIi :.. a tEVIEWED FOR DE COMPLIANCE . LUCIE COUNTY BOCC FI. -0 11105 FIRM AA003n si OF 7 : ..:: SIMPSON H2.5A CLIP FULLY NAIL TO (2)2x8 P.T. 11111 I I fill/ REVISIONS BY DATE/ FAR I D AB U GATTAS P . E . LEDGER ATTACHED WITH: `��`�®�(�((��/j�' ' 1 CITY COMMENTS F.A. 06/26/19 - -TRUSSES UP TO 20' LONG: 3/4" 04" EMBEDMENT �� ` F °•" �'� % • �� 2 REV F.A. 08/02/19 POWERS WEDGE BOLTS @16" O/CSTAGGERED. ` �;.° CENS ENGINEER I AT ' -LONGER TRUSSES. 1 3/4"x6" EMBEDMENT �. STRUCTURAL 2X4 BLOCKING @ A O ATTACH 2x4 BLOCKING WITH (1)1CH DE i'7 ; 7318 TEXAS TRAIL PLYWOOD SEAMS, ATTACH W/ I: < POWERS WEDGE BOLTS. 6" TO EACH SIDE OF � PIO 72479 �, 11 SIDE ATTACH 2x4 2- 16D TOE NAILS EACH END EACH TRUSS. STAGGERED. TAPCONS @ 12" O/C, 4" FROM EACH SIDE -. NAILER W/12d's@8" OF EACH TOP CHORD _ - BOCA RATON, FLORIDA 33487 O/C TO TOP I SEE PLAN 3/4" CDX T&G PLYWOOD, ATTACH PHONE: 954 667 - 7803 FAX: 561 ` 665 - 5438 CHORD. FRAMING T. / TRUSS WITH GLUE AND 10D RING SHANK �® 3TA O �2q� PROJECT CLASSIC l P NAILS @ 4" O/C AT PLANEL EDGES TEMPERATURE REINF. ��° °°•. R� ��`� P.E. LICENSE # 72471, CA#29407 - AND 6" O/C IN THE FIELD i���v •'°• �`� Structural Engineering VVM.PROJECTCLASSIC.COM PROJECT# FLOORTRUS ES FLOORT USSESD--' FRAMING MAIN TOP REINF.//®® A��e� 8/2/2019 FARID@PROJECTCLASSic.com 4759 PRE-ENGINEERED 11 PRE-ENG AT 24" O.C. AT 24" O.C. FLOOR TRUSSES � � - PLAN SLOPE PER ARCH I I 1 AT 24" O.C. .. 2X4 BLOCKING ZNGSC OF e: e AT ALL PLYWOOD 4" D.C. - -- e e " SEAMS, ATTACH ED. e e e. ♦ W/ (2) 16D TOE NAILS NGS. r 2x4 BOTTOM 2x4 BOTTOM CHORD TO TOP CHORDS. CHORD BRACING BRACING END BOTTOM REINF. NOTE: SEE ARCHITECTURALS GIRDER TRUS SEE APPROVED SHOP END W/(2)16d FOR W/(2)16d FOR NAILS. FOR ROOFING TYPE. SE DRAWINGS FOR TRUSS NAILS. GIRDERTRUSTO GIRDER CONNECTION.PRE-ENGINEERED WOOD FLOOR @ 24" 0/0 TRUSSES.SEE PLYWOOD NAILING DETAI(2) 2x8 SP#2 P.T. WOOD LEDGER: FOR NAILING PATTERN.- - - -FLOOR TRUSS PERPENDICULAR FLOOR TRUSS PAR LLEL OWERSWE TO GEB LT@16" /CST GGEREDf'� 2 TO GIRDER POWERS WEDGE BOLT @t6" O/C STAGGERED. o VSOC:A GRDER LONGER TRUSSES: W/ 3/4"0x6" EMBED POWER o WEDGE BOLT@6 TO EACH SIDE OFEACH TRUSS. T/ TIE , . > BEAM ®° `/ 1•/ S2 SCALE: 3/4" = 1° 3 SECTION 2ND REAR BALCONY PER LE: 3/4n = __ __ FRAMING BOTTOM CHORD BRACING tJL SCALE: 3/4° - PLAN AND LATERAL RESTRAINTS - j : SEE TYPICAL DETAILS. ~ 2"MINI M W W 3" SEE ARC SIDECO ER w O (2) #5's ' (2) #5's (2) #5's (2) #6's (2) #5's (2) #5's (,>#5 TYPICAL O HURRICANE TIES. a 4 6/6 WWM 0 0 o H W 1.4XW1. ° ° 0 PRE -CAST LINTEL: SOLID Y = SEE STRAP SCHEDULE u SLOPE PER PLAN[[I (2 #5's (2) #5'sLLI (2) #5 s ROOFa ° GROUT CMU OVER LINTEL N BOND BEAM PAVERS PCL :� (1)#5 8„ 18- I � 8„ . TRUSS TO SIMPSONSTRONG-TIE r OIL T.O.S #3 TIES @4" O/C TIES: (9) #3@4", : ---- C ABU44 SEE PLAN = I^ #3 TIES @24' 0/C BOND BEAM ' L�J BAL @ 24" 0/C (2) #7's —� BOND BEAM B812 B812-1 B812-2 6" (2>#5's L� I I L(2) #6's REINFORCED CMU WALL 4. DETAIL 5 SECTION 6" LAPPED AND TAPED (2) #6's I 8" I SEE FOUNDATION AND FRAMING W 6 MIL. V.B. OVER 1 2) #5's #3 TIES @15" O/C 8" PLAN FOR VERTICAL 1 r•'-f (4) #5's #3 TIES @24" O/C I I REINFORCEMENT DIAMETER AND n - f 3n_ COMPACTED TERMITE �``I, I,�..--_" �~ ( Q S2 SCALE: 3/4 - S2. TREATED SOIL - --I B820 Q TIES:(14)#3@10", LOCATION. 8 PER 12" T. DEPTH L B 822 BAL @ 24" O/C SEE TYPICAL DETAIL FOR 1� 1 #4 CONT. REINF. I Q B824-1 LADDER TYPE REINFORCEMENT. ¢ .t.. O. (2) #5,s " o 1.4 W Sz 6 XTERIOR SLAB THICKENED EDGE N (2) #5's +rD ,°_a:, Q =" Q S7 S7 +z:_o';•; S2 SCALE: 3/4" = 1' o " E 1U4 m 4 - _ =q O N 1 -411 (4) #5's + I v ll (z) #7 s - 1 a #3 TIES @24" O/C I ). 6 (2) #5'S B 1626 I� III L II 1 32' I , #3 TIES @15" O/C 9 EEDET I 1/S3 OR : ; IIq�_8" II II 3'_211 II3'-4" II 3I-10" II 2' II 2' II Ao-, II II 6'-1d'I i II i I Iry -? 8 I S3 II III `.` LYWOO I AILIN PATTE N I ; I.' , 2 11 6'-6,1 li B 34 TIES: (7)#3@16", I \ ND SP IFICATI NS. ; =260 , --- - - - , BAL @ 24" O/C RE n — Q OOF? SSES 24"O/ ` +49.8 +49.81 ❑� '� ( •' 2 #6's O O 3 #5's ' ❑o' 15 OP BEAM TO RECEIVE _54.15 B822 `- --- - (, 11 • ,}, O 2 #5's 4 #5's O B83V i° AXSP ING.SE APPR ED �`� �I 8822 -54.1 HOPD ING T/+14' GIRDERTRUSS Tt,4-0" '❑ ,� — — — — ¢� , OR GO RNING AYOUT 'n — — — — — _ — — — — 3 #5's (3 #5's x °� v : mN ❑� °1 l.. V ` o -O ) I , III I II II ❑ 3 PL 7x10x3/4 III 24" DEEP PRE-ENGINEERED WOOD cc FLOOR TRUSSES @ 24" O/C i -- ---- ----- ----- - - ---- ----- ----- --- - m t S7 .HSS BELOW. II MAX SPACING.SEEAPPROVED1 S7 ` 1 OP-DRAWINb"S— 1 I �` J , • n 14 13 FOR GOVERNING LAYOUT.— — a , �. TINE R RESE s WOO $7 N is (2) #5's 1 — �. TRUSS X4 Y (2) #5's (4) #5's Y i ° i III CI SPAC D MAX II I +1 ' 0" + o (3) #5's " o S3 `� 10' C EE DE Iy2(S3 (2) #5's - —III �� H AM A : II i O� — — — — L — , �i • #3 TIES @18" O/C — - I - ` 2 = 5 i' i0� /STRUCTUR 1 v i N ' `i O — — rr�� $, VJ $$$ #3 TIES @24" O/C _.. -- --- - --- -zl I ` , <h f B 1222 - ----- ----- --- - --- - _ +13' — s2 �l — — — E� (� - - - _ U P B 1224 (3> #5's v BOND O PL 7x10x7/8 Ie i ~ :� m F UF6 12 I $7 ` _ — HSS RFI OW = C7 ❑ Y p +. (2) #5's i-—�I #3 TIES @24" O/C (3) #5's _ ` III � I II � II ❑, � q IIII HSS BELOW _ _ � , � I 8„ 61228 1 " ., .� ° ' � � �� _ = 2T HSS BELOW �� — — — �❑ 3,_' ti'-6"'; 1,�q„ 10 H TIES: (8) 0@10 (2) S. (U # 5 (1) # 5 #3 TIES @24 � S3 \�❑� S2 ❑ +� BAL @ 24" O/C 8" `v _ _ ----- ----- - -- ----- ----- ----- --- - — — — _ _ _ ' U �•+' B 1234 z , --- ----- — p B812 B 84O .PRE -CAST LINTEL: SOLID <.. ro - _= _ - .. ❑ ❑ I ❑ ❑ - - �' Y *„ TIES: (7)#3@16", - BAL @ 24" O/C GROUT CMU OVER LINTEL m a w III J ' P ' — -GT — o 4 8812 , Bt 26 , t/] x B846 (1)#5 ¢ a II — — — T m� i m /STRUCTURE *+ DROP BEAM TO RE EIVE o ,�„ 4 " Y +12'-6" = i° :'? i i GIRDERTRUSS III vv� s BOND BEAM12" — — — aa @�aa IN,;.. 6„$ LOADING THIS LEV L = _ --- ---- ----- ----- - ---- 14 13 - -� - n i = _ = 32 W T „m j<t 3000PSI zPL 7x10x7/8 " of ' N m Co 1 : , INTERIOR FLOORS (65PSF) �' p S7 S7 �` i i 24" DEEP PRE-ENGINEERED WOOD ° 4,_4„ FLOOR TRUSSES @ 24- O/C S6 HSS BELOW «: Z. " v@ DEAD (25 PSF). FLOOR SYSTEM=7 PSF - >a III I II \ II ; SHOP RAWI DRAWINGS - PL 7x10x5/8 G B81 ° p N • z FLOOR FINISHES = 15 PSF Q i ❑ ❑ I ❑ ❑ ❑ ❑ ❑ + 4 DUCTWORK= 1 PSF �FH2 IIL,�' I FOR GOVERNING LAYOUT. HSSSELOCN— m 2.' CEILINGS =2 PSF - - _ _ 0 BM. _ __ ._ �..I .-- --. \ B812 / - - ° - — — "�-�'—I — co O q LIVE(40PSF) OCCUPANCY LIVE=40PS 3 - -- °-- -- •-° c = _ _ _ _ 210 \\_ " ❑ Fw 3 o i + Job No. 1311136 \PL 7x10x5/8 X m I 0D = BALCONY WITH AREA OF 100 SQFT OR MORE 12 PSF = -�— _ _ _ _ = _ / \ m 10 m q + - O " HETA 2 16 —_ - HSS�BELOVj/ T +13'-0" A T, ❑ o m Q 12I i i S3 e^ a•' .DEAD (25 PSF) FLOOR SYSTEM SELF WEI HT= i PSF r + - 50 822 C ❑ " I O I6 FLOOR FINISHES = 16 PSF .O. ¢ =13 0 — —_ rn % ❑ ❑ �IC] p 0 ❑ t a" °" .CEILINGS=2PSF +12'-0" y¢ T.O.B "), 24"DEEPPRE-EN_GIPEEREE_ WOOD O> 16 '\ - DETAI 1/ FOR - ceee +o" _ w \ 3' 3'-8" P WOOD ING PATTERN 2H A16 e" • LIVE 100PSF OCCUPANCY LIVE - 100 P F w m q , 02 T$U `i�0(� : = • ( ) I' w» MAX SPACING.SEE APPROVED a z \ A1dD SPE _ ROOF(55 PSF) _ .:, ORDRA a ,••-'r— _ N.t-U R" ❑ Ao N , = C L �, - FOR GOVERNING LAYOUT. F " _ _ _ o _ _ GINEERED WOOD. o� T. LUCIE-. COUNTY DEAD (35 PSF) PLYWOOD = 2 PSF' �� — �/� mN — — 14 SHOP D 2 1 • " / •-� FOR G ERMAX SPIG. EE APPROVED - • • • TRUSSES = 7 PSF : �, /STRUCTUR _ — _ I— ' S • • ..INSULATION = 1 PSF 'f —+13.- — — — — +co S7 NI T. FL-1�).]].05 FIRM-.AA003379 S. a^ - e^ a^ DUCTWORK = 4 PSF _ _ _ _ y 14 ROOFING = 19 .; : 10 , S7 1155 7 CONC.COLUMN C3 cEluNGs=zPSF - r , - of 1 . _ ;,_ 8 CONC.COLUMN'C4 LIVE(20PSF) CONSTRUCTION=20PSF `r ❑_j I II ; .[TIC SZ SCALE.11/2 1' S7 00 SZ SCALE: 1-1/2" = 1' PANEL POINTS 200 LE LIVE ��N ' B834 BOND B f: ROOF LOAD DISTRIBUTION TO CHORDS: ❑ ❑ 11 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ' ❑ ❑ ❑ ❑ ❑ ❑ ' ❑ ❑ ❑ -42 DEAD (35 PSF) TOP CHORD = 25 PSF 3,-8„ 3,4" 3,_4" 3,_ 3,-4".. 3'-4" 3,_8, , BOTTOM CHORD =10 PSF LIVE (20 PSF) TOP CHORD 20 PSF `. T.O.B. T.O.B. r+�aa - 4' a 7 HETA16 9 "ry u z FLOOR COLUMN PLAN 1 +13'p'I +12'-0" 4 S3,' OF7 BOTTOM CHORD - PANEL POINt LOAD SECOND _-$, 4b $2 b b b ' t