Loading...
HomeMy WebLinkAboutLetter; Wood Frame to close pitPROJECT CLASSIC LLC. �;,,t,�.. _ . ...... _ RECEIVED Structural Engineering "F. JUN 18 2019 7318 Texas Trail Boca Raton, Florida 33487 www.projectclassic.com ST. 6ucleCo�nty, Permitting CA# 29407 Project: Avalon Lot 25 Building Department Subject: Wood frame to close', pit / chase for future elevator ' Address: Avalon_ Beach P.U.D., Ocean Estates Drive, North Hutchinson Island, FL Gentlemen To close the openings for future elevator at ground and first floor use 2x6 joists @12" O/C. Attach 2x6 RT ledger to concrete slab / tie beam with 1/4" X 3-1/4" tapcons, install (2) tapcons 3" to each side of each rafter, 3" vertical separation between them. Connect 2x6 joist to wood ledger with Simpson HU26. Sincerely yours Monday, May 20, 2019 Farid Abugattas, P.E. # 72471 farid@projectclassic.com PH: (954) 667-7803 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC OPY C:\Users\PCPrime Workstation\Dropbox\Wood frame to close pit chase for future elevatotodt - 5/20/201E 1 Loo 5' Page# ] Of 1