HomeMy WebLinkAboutLetter; Wood Frame to close pitPROJECT
CLASSIC LLC. �;,,t,�..
_ . ...... _ RECEIVED
Structural Engineering
"F. JUN 18 2019
7318 Texas Trail Boca Raton, Florida 33487
www.projectclassic.com ST. 6ucleCo�nty, Permitting
CA# 29407
Project: Avalon Lot 25
Building Department Subject: Wood frame to close', pit / chase
for future elevator '
Address: Avalon_ Beach P.U.D.,
Ocean Estates Drive,
North Hutchinson Island, FL
Gentlemen
To close the openings for future elevator at ground and first floor use 2x6 joists @12" O/C. Attach 2x6
RT ledger to concrete slab / tie beam with 1/4" X 3-1/4" tapcons, install (2) tapcons 3" to each side
of each rafter, 3" vertical separation between them. Connect 2x6 joist to wood ledger with Simpson
HU26.
Sincerely yours
Monday, May 20, 2019
Farid Abugattas, P.E. # 72471
farid@projectclassic.com
PH: (954) 667-7803
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
OPY
C:\Users\PCPrime Workstation\Dropbox\Wood frame to close pit chase for future elevatotodt - 5/20/201E 1 Loo 5' Page# ] Of 1