HomeMy WebLinkAboutNotice of Product Certification; Series 9700 Impact Sliding Glass DoorNOTICE OF PRODUCT CERTIFICATION
-0
Qet V
A
CERTIFICATION NO:
DATE:
CERTIFICATION PROGRAM:
COMPANY:
CODE:
REVISION DATE:
NI011590.02-R2
08/01/2013
Structural
Shwinco
1927-1
06/19/2015
To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. ANAMI approved certification label mustbe applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS
PRODUCT DESCRIPTION
Shwinco Architectural Products, LLC
Series 119700" Impact Rated
171 Jet Services Way
Vinyl Sliding Glass Door
Dothan, AL 36303
(1.75" Sill Riser)
Configuration: XO
Glazing: IG-Ext-3/16" Tempered Glass/
Int-Laminate-3/16" Annealed Glass/0.090" Interlayer
by Solutia/3/16" Annealed Glass
Frame: W-2438mm(96") H-2438mm(96")
Panel: W-1257mm(49.5") H-2369mm(93.23")
SPECIFICATION
PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-08
Class LC-PG60 2438 x 2438 (96 x 96)-SD
ASTM E1886-02/04/05/E1996-04/06/09
Design Pressure: +60/-60 psf
Wind Zone 4-Missile Level D
Water Penetration Resistance Test Pressure: 504 Pa (10.5 psi)
Product Tested By: National Certified Testing Laboratories
Report No: NCTL-210-3886-IA
Expiration Date: May 31, 2020
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, W&EWED
4794 George Washington Memorial 'LAZE ®�
Hayes, VA 23072 ®MPL'e41lSCE
Tel: (804) 684-5124 ST. [LUCIE COUNTY
Fax: (804) 684-5122 BOCC
NDALL E. STOFFT VtMITECTSI F L
AA#003379
APPROVED ❑ REVISE & RESUBWHT
APPROVED AS CORRECTED ® REJECTED
This review is only for general conformance w .h the d-ign concept of the
project and gencraCccmpiiance v,q the info rnet given in the pniraact
documento. Correet.ns or ccmmants made on the shop drawings during
fill revie a da.not relieve UIB corilrac Gr from compliance With the req lire
a, a s vcl'_�:ians. Approval of a speclac item shall hot
a, ,ov i e 4r i ;e;.�I,� of which iha item is a component Corr
ri fur: Dimenzions to be confS�iied and cGira!3ted at the
pert=i:is: s,*ely to the fabricat en processes o; to
the rizans, ni '. n{' loch s,_sagtiences and procedures of construr
tor,: cGcrdir;W'io:� of t aa'.:hrh ':l aver trades: and for performing all work
in a safe and sat3f ct_ry mancf aner. .
DATE: Z I _ � era: