HomeMy WebLinkAboutProduct Review; Series 9000 Single Hung (Impact)INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR OR INSTALLATION STRAP IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF tl/2 INCH OF THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH THROUGH FRAME INSTALLATION ANCHOR OR INSTALLATION STRAP WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. S. FOR FIN INSTALLATION INTO WOOD FRAMING USE 5d ROOFING NAILS THROUGH FINS WITH SUFFICIENT LENGTH TO ACHIEVE 21NCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE OR A8 PAN HEAD WOOD SCREWS THROUGH FINS WITH SUFFICIENT LENGTH TO ACHIEVE 11/2 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. 6. FOR FIN INSTALLATION INTO STEEL SUBSTRATES, USE N10 TEK SCREW THROUGH FIN WITH SUFFICIENT LENGTH TO ACHIEVE MINIMUM PENETRATION OF 3 THREADS THRU STEEL SUBSTRATE. 7. FOR FLANGE AND CUP INSTALLATION INTO WOOD FRAMING USE 410 WOOD SCREW FRAME WITH SUFFICIENT LENGTH TO ACHIEVE 11/2INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. 8. FOR FLANGE AND CLIP INSTALLATION THROUGH 1X BUCK TO CONCRETE/MASONRY, OR DIRECTLY INTO CONRETE/MASONRY, USE 3/161NCH DIAMETER ITW TAPCON OR EQUAL OF SUFFICIENT LENGTH TO ACHIEVE 1 1/41NCH MINIMUM EMBEDMENT. 9. FOR FLANGE AND CLIP INSTALLATION INTO STEEL SUBSTRATE, USE#10 TEK SCREW OF SUFFICIENT LENGTH TO ACHIEVE MINIMUM EMBEDMENT OF 3 THREADS PENETRATION BEYOND STEEL WALL 10. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 11. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 12. FOR HOLLOW BLACK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 13. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 14. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 2700 PSI. C. MASONRY - SHALL CONFORM TO ASTM C90. D. STEEL- MINIMUM YIELD STRENGTH OF 33 KSI. MINIMUM WALL THICKNESS OF 47.8 MILS. (18 GAUGE), SHWINCO ARCHITECTURAL PRODUCTS, INC. SERIES 9000 SINGLE HUNG (IMPACT) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), EXCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING AAMA/WDMA/CSA 101/15.2/A440.05 ASTM E 1996-02/05 ASTM E 1886-02/05 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY AND 2X FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECTOF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: VINYL (PVC) 7. GLASS MEETS ASTM E 1300-04 GLASS CHART REQUIREMENTS. SEE SHEET 4 FOR GLAZING DETAIL. S. DESIGNATIONS "X" AND "0" STAND FOR THE FOLLOWING: X: OPERABLE PANEL O: FIXED PANEL TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - INSTALLATION & GENERAL NOTES 2A - ELEVATION & ANCHOR LAYOUT 26 - ELEVATION & ANCHOR LAYOUT 2C - ELEVATION & ANCHOR LAYOUT 2D - ELEVATION & ANCHOR LAYOUT 3 - VERTICAL SECTIONS 4 - VERTICAL SECTIONS & GLAZING DETAILS 5 - HORIZONTAL SECTIONS 6 - COMPONENTS & BILL OF MATERIAL DESIGN PRESSURE RATING SIZE DESIGN PRESSURES MISSLE IMPACT RATING GLAZING- (53" x 74") a100/-110 P5F LARGE AND SMALL SEE SHEET 2A FOR DETAILS MISSILE TESTED GLAZING - (53" x 74") +70/-110 PSF LARGE AND SMALL SEE SHEET 2A FOR DETAILS MISSILE TESTED GLAZING - (53" x 96") *60/-70 PSF LARGE AND SMALL SEE SHEET 2B FOR DETAILS MISSILE TESTED GLAZING - (53" x 96") .50/-50 P5F LARGE AND SMALL SEE SHEET 2B FOR DETAILS MISSILE TESTED SEE SHEET 4 OF 6. sisevfw�en"wszw TITLE: SERIES 9000 SH (IMPACT) INSTALLATION & PREPARED FOR: SHWINCO ARCHITECTURAL PRODUCTS, LLC. DATE: 6-14-16 DRN BY: KR5 CHK BY: GRK SCALE: NTS REVISIONS W F R a DWG #i: SAP.W.1003 SHEET: 1 OF 6 r Roofi ELEVATION FIN 8. O.C.TYP. ANCHOR LAYOUT FIN 4-TYP. r Imtw6w �r3�iti�ria� -- S' O.C.TYP. ANCHOR LAYOUT FLANGE fYP. NOTE: WHERE PRESSURE REOUIREMENISARE LESS THAN 100 PSF THE MAXIMUM SPACING CAN BE INCREASED TO 11. O.C. No Feneners wem emP" ® 0 ATTACHMENT DETAILS FOR APPLICATION OF DP +100/-110 PSF & +70/-110 PSF. WOOD AND STEEL APPLICATIONS. rTTI F- 5ERIE5 9000 SH (IMPACT) ELEVATION 6 ANCHOR LAYOUT PREPARED FOR: SHWINCO ARCHITECTURAL PRODUCTS, LLC. DATE. 6-14-16 DRN BY: KRS CHK BY: GRK SCALE: NTS REVISIONS H � o Zcz ~ d V Lu E 0 $� DWG #: SAP.W.1003 SHEET: 2A OF 6 MDTH S]DT .F'MCR NADTXS]DT e® F-'<" D. Aa c3 D / s �.r Jp6NS � u asr Ali. 5 5 of i W o �1�} a Did oats TITLE: SERIES 9000 SH (IMPACT) l EILDta,I x o LAYO ANCHOR ELEVATION UT Az a Da PREPARED FOR: 3 3 3 D2 SHWINCO ARCHITECTURAL 4 PRODUCTS, LLC. .6.6t5'MMt OlA. WOIX ono. mo X DATE: 6-14-16 ELEVATION ELEVATION FLANGE FIN DRN BY: KRS CHK BY: GRK SCALE: NTS D.D.IYp. ,•M�. " R. ' REVISIONS w �� 0•MVI. FROM �� PM9R.FROM % ­.FROMQ ca+tmrn. rnRXr:R,rv. coRXFn nv. Q „rwDc oe M� 0 m o p o l To yi/ V x x V) x LU w /w O ORRERSR� 6•MVC FROM 6•W1x.FROM Z _ ANCHOR LAYOUT -ERSM ANCHOR LAYOUT `°""`RsnR• DWG #: ANCHOR LAYOUT FLANGE FRAME FLANGE CLIP FIN 5AP.W.1003 SHEET: ATTACHMENT DETAILS FOR APPLICATION OF DP+60/-70 PSF & +50/-50 PSF. WOOD AND STEEL APPLICATIONS. 2B OF 6 r Roaf, UNIT MAX FI FVATInfU a 111,111 ANCHOR LAYOUT FIN TYP. r lna laliP ELEVATION FLANGE T�..,.I..n 5.5' O.C.TYP. ANCHOR LAYOUT FLANGE CIM MERE PRESSURE EOUIREMENTSARE =-SS THAN 100 PSF THE AXTIAUM SPACING AN BE INCREASED TO O.C. ATTACHMENT DETAILS FOR APPLICATION OF DP +100/-110 PSF & +70/-110 PSF. MASONRY APPLICATIONS NO.52454 a11�T1a-09T6fu Ne 52sa1 TITLE: SERIES 9000 5H (IMPACT) ELEVATION 6 ANCHOR LAYOUT PREPARED FOR: SHWINCO ARCHITECTURAL PRODUCT5, LLC. DATE: 6-14-16 DRN BY: KRS CHK BY: GRK SCALE:NTS REVISIONS D WIG, ## SAP.W.1003 SHEET: 2C OF 6 MTH53- D.eT eau wom ssav c® re'MAR D.�o. reom .etw4r AI Cl-oLa.INOm a °�r 0 rs.rsc 5 9 7 F i '3 DL.o. o %� A � �•1� REI°�GNi A/ RctcRr 3 ,"c'_ssl(�b�w`,a`w TITLE: x °t o• SERIES 9000 SH (IMPACT) �W^ x ELEVATION& ANCHOR LAYOUT Az cz D3 PREPARED FOR: 3 3 3 D2 SHWINCO ARCHITECTURAL PR 4 PRODUCTS, LLL. aen•tuc DL.D.\MOm 18AlSMPJI °J'Np1N DATE: 6-14-16 ELEVATION ELEVATION FLANGE FIN DRN BY: KR5 CHK BY: GRK t:aa DAc SCALE: NTS FTo.a Tm. aw�xraota oe.rn- rnucfaw msewc snurRou wRR �. GORNERT9 °`�° �RR�R,rP- REVISIONS __ _ IDY 1L1l // GOIII+ERTYV. �� CORNERTW. /� CORRERiw. Q Z. O.O. M \DS lWL O.G.TW. o 0 tD.rswx I x x x w a r wu. rRor -R Z co— ANCHOR LAYOUT GOIbSi18TW. ANCHOR LAYOUT `°"XEpS 4' DWG #.. ANCHOR LAYOUT FLANGE FRAME FLANGE CLIP FIN SAP.W.1003 SHEET: ATTACHMENT DETAILS FOR APPLICATION OF DP +60/-70 PSF & +50/-50 PSF. MASONRY APPLICATIONS 2D OF 6 PERIMETER SEALANT 2 1/16' MIN. EDGE BETWEEN CONCRETE! DISTANCE MASONRY S 1X WOOD BUCK BY OTHERS 3116' ITW PCON 1X WOOD BUCK INSTALlAT10NANCHOR BYOTHERS CONCRETElMASONRY �. BY OTHERS PERIMETER SEALANT - 11/4' MIN. BY OTHERS y„`!rEMBEOMENT 1/4' MAX. 10 SHIM SPACE O.A. WINDOW HEIGHT EXTERIOR 7 INTERIOR SEE GLAZING DETAILA Al VERTICAL SECTION 3 HEAD-CONCRETE/MASONRY FLANGE PERIMETER SEALANT BETWEEN CONCRETE/ MASONRY& 1X WOOD BUCK BY OTHERS iX WOOD BUCK BY OTHERS F. t. PERIMETER SEALANT t BY OTHERS O.A. WINDOW ..i HEIGHT EXTERIOR 1 SEE GLAZING DETAILA 2 1/2' MIDI EDGE DISTANCE a® lLTI 3/16' ITW TAPCON 1 INSTALLATION ANCHOR J CONCRETEANASONRY � V E 1 I I 7 No.BZ484 (�kL-`•'"; BY OTHERS w�* OODTRIM BY OTHERS ` f�.�3/��ylSL7AlC 1/4" MAX SHIMSP, EM EDMENi INTERIOR n»-a�ws'nrtwws�n Cl_ VERTICAL SECTION -OPTION 3 HEAD-CONCRETE/MASONRY FLANGE EXTERIOR INTERIOR 1LJ�L VERTICAL SECTION EXTERIOR INTERIOR SEE GLAZING 3 MEETING RAIL SEE GLAZING 8 DETAIL B IN O.A. WINDOW IC 10 5 i� O.A. WINDOW IC 5 HEIGHT HEIGHT I1 SEALANT BEDDING - f1 SEALANT BEDDING - DAP 800 OR BETTER 1/4' MAX DAP 8D0 OR BETTER 1/4' MAX. PERIMETER SEALANT SPACE PERIMETER SEALANT SPACE BY OTHERS BY OTHERS - `PRE -CAST SILL BYOTHERS PRE -CAST SILL BY OTHERS `,,• CONCRETEWASONRY !� +'; •.'4^, CONCRETEIMAS '�• 'A" BYOTHERS �' -•A� BY OTHERS A2 VERTICAL SECTION - OPTION C2 VERTICAL SECTION - OPTION 3 PRE-CASTSILL-CONCREWMASONRY 3 PRE -CAW SILL -CONCRETE/MASONRY CASTECRETE FLUSH OR HIGH WIND FACE SILL OR EQUAL. CASTECRETE HIDRI SILL OR EQUAL FLANGE - NO FASTENERS FLANGE - NO FASTENERS TITLE: SERIES 9000 SH (IMPACT) VERTICAL SECTIONS PREPARED FOR: SHWINCO ARCHITECTURAL PRODUCTS, LLC. DATE: 6-14-16 DRN BY: KRS CHK BY: 6RK SCALE: NTS REVISIONS Q LZLL iL o U a � a DWG #: SAP.W.1003 SHEET: 3 OF 6 SHEATHING BY OTHERS FLASHING BY OTHER PERIMETER SEALANT BET WEE FINB SHEATHING EXTERIOR FINISH BY OTHERS BY OTHERS PERIMETER SEALANT O.A. WINDOW 10 HEIGHT EXTERIOR / SEE GLAZING / OETAILA JJJ 2' MIN. AEDMENT (FIN) 5d ROOFING NAIL INSTALLATION ANCHOR 2X WOOD FRAME BY OTHERS 1/4- MAX. SHIM SPACE 3/4• MIN. EDGE DISTANCE (FIN) INTERIOR D1_ VERTICAL SECTION a I HEAD-ZXWOODFRAME EXTERIOR INTERIOR SEE GLAZING S DETAILA O.A. WINDOW IOK 5 HEIGHT LA LL PERIMETER SEALANT BY OTHERS EXTERIOR FINISH BY OTHERS PERIMETER EXTERIOR INTERIOR SEE GLAZING Tf-hr SEALANT BEDDING - " 1 1/4' MAX DAP 8000R BETTER 1� SPACE PERIMETER SEALANT BY OTHERS WOOD FRAMING BY OTHERS D3 VERTICAL SECTION - OPTION (4 SILL-ZXWOOOFRAME I/4• MAX SHIM SPACE 3/4• MIN.EDGE DISTANCE r (FIN) 1 R SEALANT BETWEEN 2X FIN & SHEATHING AAME BY WOOD WOOD F SHEATHING BY 910 WOOD SCREW OTHERS INSTALLATION 1 1/2• MIN. ANCHOR EMBEDMENT (FIN) _D2 VERTICAL SECTION (� SILL-2XWOOD FRAME LOD" O.A. INSULATED GLASS CONSISTING OF: 0.1875" ANNEALED GLASS, r Z 0.500" AIR SPACE, ."_. .* 4•�/� +- 0.125• ANNEALED GLASS, lO O•OW PVB INTERLAYER BY SOLUTIA. SYAiE OF iw 0.125' ANNEALED GLASS Von / INTERIOR 1 0.875• GLASS ' I TITLE: BITE i 1 1 SERIES 9000 SH (IMPACT) 19 VERTICAL SECTIONS � GLAZING DETAILS EXTERIOR1� 21 PREPARED FOR: SHWINCO ARCHITECTURAL PRODUCTS, ux. GLAZING DETAIL A DATE: 6-14-16 ORN BY: KRS CHK BY: GRK LOD' O.A. INSULATED GLASS CONSISTING OF: SCALE: NTS 0.125" ANNEALED GLASS, O.5D0" AIR SPACE' REVISIONS 0.125' ANNEALED GLASS, 10 0.090" PVB INTERLAYER BY SOLUTIA, w / , 0.125' ANNEALED 6LA55 F- C INTERIOR M 0.87BI GLASS BITE j TE L` U 19 2 F' EXTERIOR 21 GLAZING DETAIL B (DP+60/-70) o DWG#. SAP.W.1003 SHEET: 40F6 1 1/4' MIN. EMBEDMENT (FLANGE) 3116' ITW TAPCON INSTALLATION ANCHOR 2 1/16• MIN. EDGE DISTANCE ( M PERIMETER SEALANT BETWEEN 1X WOOD 1/4• MAX. INTERIOR SHIM SPACE �1X WOOD BUCK BY OTHERS OPTIONAL SEE GLAZING DETAILA BUCK& BY OTHERS EXTERIOR CONCRETE/MASONRY BY OTHERS O.A. WINDOW WIDTH A3 HORIZONTAL SECTION -OPTION I C I IAMB-CONCRETE/MASONRY FLANGE-THROUGHFRAME 1/4'ti MAX. SPACE2X WOOD FRAME 3/4. EDGE 1 1/4' MIN. EMBEDMENT (FLANGE) 311W ITW TAPCON miy�Lla�RS1e 4 8Y OTHERS DISTANCE INTERIOR ' (�) ocneMc.uR SEALANT - SC ROOFING NAIL INSTALLATION ANCHOR Z' MIN. EMBEDMENT (FIN) 1/4• MAX. INTERIOR SHIM SPACE �1X WOOD BUCK BY OTHERS OPTIONAL SEE GLAZING DETAILA BUCKS y PERIMETER SEAIANT EXTERIOR DM CONCRETESONRY � :.I :;, BV OTHERS BY OTHERS O.A. WINDOW � WIDTH SEE GLAZING C3 HORIZONTAL SECTION DETAILA 5 JAMB-CONOtM/MASONRY FLANGE -THROUGH FRAME EXTERIOR FINISH BY OTHERS 6PERIMETER SEALANT EXTERIOR FLASHING BY OTHERS BY OTHERS PERIMETER SEALANT BETWEEN FIN 8 SHEATHING D4 HORIZONTAL SECTION 5 JAMB -2KWOODFRAME ROOFING NAIL 1/4' MAX. _ SHIM SPACE 3/4• MIN. EDGE DISTANCE (FIN) INTERIOR 18 GAUGE STEEL FRAMING BY OTHERS 610 TEK SCREW IL SUFFICIENT TO »c)JELOJAF1�i�o�s:�n ACHIEVE A MIN. 3 THREADS THROUGH TITLE: SEE GLAZING / WALL DETAILAl IG SERIES 9000 5H (IMPACT) EXTERIOR FINISH BY OTHERS HORIZONTAL SECTIONS PERIMETER SEA10 EXTERIOR BY OTHERS SHEATH INO.1 OTHERS PREPARED FOR: O.A.W PERIMETER SEALANT WIDTH WIDTH BETWEENFIN SHWTWO ARCHITECTURAL 8 SHEATHING PRODUCTS. L.I.C. E HORIZONTAL SECTION 5 JAMB -METAL STUD DATE:6-14-16 SMS SCREW DRN BY: KRS CHK BY: GRK 11/2' MIN EMBEDMENT SCALE: NTS 1/4• MAX. (FLANGE) SHIM SPACE 2XFRAME REVI5ION5 SHEET ROCK BY OTHERSOTHERS BY OTHERS 610 WOODISMS SCREW fU - INTERIOR Ina m ff 7 ` Z 3/4'MIN. EWE Q DISTANCE (FIN) SEE GLAZING � DETAILA IO - U Fa 11) n PERIMETER CAULK SHEATHING BY W 4 BY OTHERS OTHERS EXTERIOR O.A. WINDOW E%TERIOR BRICK FINISH WIDTH BYOTHERS Z DWG# G HORIZONTAL SECTION SAP.W.I003 5 IAMB -REPLACEMENT SHEET: 5OF6 BILL OF MATERIALS ITEM NO. DESCRIPTION MATERIAL MANUFACTURER I HEAD, JAMB FRAME (FIN) VINYL SHWINCO IA SILL FRAME (FIN) VINYL SHWINCO 18 HEAD, JAMB FRAME (FLANGE) VINYL SHWINCO iC SILL FRAME (FLANGE) VINYL SHWINCO 2 SASH HEAD VINYL SHWINCO 3 FIXED MEETING RAIL VINYL SHWINCO 4 HEAD INSERT VINYL SHWINCO 5 SILL RISER (2') VINYL SHWINCO 6 SILL RISER (1.1875') VINYL SHWINCO 7 JAMB COVER (OPTION) VINYL SHWINCO 8 LIFT RAIL VINYL SHWINCO 9 STILE VINYL SHWINCO 10 GLAZING BEAD (INSULATED) VINYL SHWINCO it SASH HEAD / LIFT RAIL REINFORCEMENT 6005-T5 VARIOUS 12 STILE REINFORCEMENT 6005-T5 VARIOUS 13 MEETING RAIL REINFORCEMENT 6005-T5 VARIOUS 14 SASH HEAD / LIFT RAIL REINFORCEMENT (LT) DP50 6005-T5 VARIOUS 15 STILE REINFORCEMENT (LT) DP50 6005-T5 VARIOUS 16 MEETING RAIL REINFORCEMENT(LT) OP50 6005-T5 VARIOUS 17 BALANCE COVER (OPTION) VINYL SHWINCO 18 WEATHERSTRIPING FIN SEAL AMESBURY 19 GLASS BEDDING - DOW 1199 SILICONE DOW CORNING 20 GLASS BEDDING-NOVAGUARD M-100 SILICONE NOVAGUARD 21 SPACER TRU-SEAL 22 INSTALLATION CLIP STEEL _ 23 TILT LATCH DALWORTH 24 LOCK/KEEPER TRUTH 25 PIVOT BAR TAINLE55 STEEL VARIOUS 26 SPIRAL BALANCES I VARIOUS 13 MEETING RAIL REINF. ALUMINUM TYPICAL WALL THICKNESS:. OW I.DT� N I 4 SASH HEAD / LIFT RAIL REINF. ALUMINUM TYPICAL WALL THICKNESS:.D4m (DP 50) 0.675• NOTE: PVC MATERIAL CERTIFICATION SHALL BE SUBMITTED UNDERCURRENT MIAMI-DADE NOA OR AAMA CERTIFIED EXTERIOR PROFILES LICENSE BY VISIONS INC. OHEAD, JAMB FRAME (FIN) VINYL TYPICAL 1A SILL FRAME (FIN) VINYL WALL THICKNESS: Wr 3.86 TYPICAL WALL THICKNESS:.06T — 1181-1 3.307' Fth 2.7I52 10 J— �C SILL FRAME (FLANGE) O SASH HEAD VINYL Vwn TYPICALWALLTHICKNESS:. G TYPICALWALLTFHCKNESS:.DW { .86°1.7T --{ 1.92� 2.118' I-FLAA B HEAD, JAMB FRAME (FLANGE) VINYL TYPICAL WALL THICKNESS:.Wir OFIXED MEETING RAIL O SILL RISER (2-) TITLE: VINYL VINYL SERIES 9000 SH (IMPACT-) TYPICAL WALL THICKNESS:.OSW TYPICAL WALL THICKNESS: COMPONENTS S OGO• ( 72• BILL OF MATERIALS 4--0.611' —{ PREPARED FOR: 2 2S 2' SHWINCO ARCHITECTURAL PRODUCTS, L-C. O IINLttL RISER (1.T87") O VINYL COVER (OPTION) O LIFT O VSTILE INn TYPICAL WALLTHICKNESS:.O60' TYPICAL WALL 7HICK14ESS:.OGV TYPICAL WALLTHICKNESS:.060' TYPICAL WALL THICKNESS: .hem r0.618' I.I87• 0.414°—-{ 1.595' 2448°-I �— t 1.4 1615' 0 GLAZING BEAD j SASH HEAD / LIFT RAIL REINF. 2 STILE REINFORCEMENT (INSULATED) ALUMINUM ALUMINUM VINYL TYPICAL WALL THICKNESS:.09m TYPICAL WALL THICKNESS:.09m TYPICAL WALL THICKNESS:.050• 11.322'r .+IIr 1.072!r Ll 0.675 yL" 0.48 I �_ 1 15 STILE REINFORCEMENT 16 MEETING RAIL REINF 7 BALANCE COVER (OPTIONAL) O INSTALLATION CLIP 25 PIVOT 8AR ALUMINUM TYPICAL WALL THICKNESS:.04m(OPSO) ALUMINUM TYPICAL WALL THICKNESS;.040'(DPSO) VINYL TYPICAL WALL TWCKNESS:.040' STEEL STAINLESS STEEL -+{ 3.346'r --{ 0' 1.45 Ir I--- 0.77T,.1 I I If'1 0.355' 1.08• F'�T-f 0.85T OA55°+ T 111 111 DATE: 6-14-16 DRN BY: KRS CHK BY: GRK SCALE: NTS REVISIONS � 4a SAP.W.1003 SHEET: 6OF6 Gene Kearley, P.E. 319 Chapelwood Drive Dothan, AL 36305 Florida Lic. 52484 Manufacturer: Shwinco Architectural Products, LLC 171 Jet Services Way Dothan, AL 36303 Product Line: Series 9000 Single Hung Window (impact Rated) Engineering Evaluation Report Report No.: 2016-0003 FL 8153.1 rev 6/13/2016 Maximum Dimensions & Design pressure: (See drawing SAP.W.1003 rev 6/13/2016) Compliance: The above mentioned product has been evaluated under method 1 (a) for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance. The product listed herein complies with requirements of the Florida Building Code excluding the "High Velocity Hurricane Zone" (HVHZ). Gene Kearley, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Supporting Technical Documentation: 1. Approval Document: Drawing SAP.W.1003 rev 6/13/2016 signed and sealed by Gene R. Kearley, P.E. (FL # 52484). Drawing SAP.W.1003 rev 6/13/2016 should be referenced for all specific use parameters. 2. Test Data: Product Test Report #NCTL-210-3280-1, Report Date: 11/07/06, Product Test Report #NCTL-210-3280-1A, Report Date: 11/07/06. Product Test Report #NCTL-210-3130-1, Report Date: 11/07/06, Product Test Report #NCTL-210-3975-01, Report Date: 08/20/14, rev 04/26/15, Product Test Report #NCTL-210-3975-01A, Report Date: 08/20/14, rev 04/26/15. Product Test Report #NCTL-210-397 -1,,?, Report Date: 06/08/15. National Certified Testing Labc��,�!@� e�_ I Organization # TST1589) Gene Kearley, P.E. Florida Lic. 52484 Report No.: 2016-0003 1of3 3. Test Standards a. AAMA/WDMA/CSA 101/I.S.2/A440-05/08 b. ASTM E 1886-02/05 C. ASTM E 1996-02/05/09 Quality Assurance a. National Accreditation and Management Institute (FBC Organization #QUA 1789) Certification Agency a. National Accreditation and Management Institute (FBC Organization #QUA 1773) Installation: Flange Installation A. For concrete or masonry substrates where one -by (1x), non-structural, wood bucking is employed, or is directly fastened to concrete, use 3/16" diameter ITW Topcon type (or equal) concrete screw anchors of sufficient length to achieve a minimum embedment of 1.25" into concrete or masonry substrates. B. For concrete or masonry substrates where wood bucking is NOT employed, use 3/16" diameter ITW Topcon type (or equal) concrete screw anchors of sufficient length to achieve a minimum embedment of 1.25" into concrete or masonry substrates. C. For two -by (2x) wood frame substrate, use #10 pan head wood screws of sufficient length to achieve minimum embedment of 1.5" into wood framing. Clip Installation A. For concrete or masonry substrates where one -by (1x), non-structural, wood bucking is employed, or is directly fastened to concrete, use 3/16" diameter ITW Topcon type (or equal) concrete screw anchors of sufficient length to achieve a minimum embedment of 1.25" into concrete or masonry substrates. B. For two -by (2x) wood frame substrate, use #10 pan head wood screws of sufficient length to achieve minimum embedment of 1.5" into wood framing. Fin Installation A. For two -by (2x) wood frame substrate, use #8 pan head wood screws of sufficient length to achieve minimum embedment of 1.5" into wood framing, OR, 5d roofing nails of sufficient length to achieve minimum embedment of 2" into wood framing. 2 of 3 Gene Kearley, P.E. Florida Lic. 52484 Report No.: 2016-0003 LA Limits of use: 1. This product has been evaluated and is in compliance with the Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. The product anchors shall be as listed and spaced as shown on the details. Anchor embedment into the substrate material shall be beyond wail dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with the Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from details of drawing SAP.W.1003 red 6/13/2016 require further engineering analysis by a licensed engineer or registered architect. S. See drawing SAP.W.1003 rev 6/13/2016 for size and design pressure limitations. Gene Kearley, P.E. Florida Lic. 52484 Report No.: 2016-0003 3of3