HomeMy WebLinkAboutProducts Review; Series 2 Mullion (Impact)NOTES L THE PRODUCT SHOWN HEREIN IS DESIGNEOAND MANUFACTURED TO COMPLYWITH THE CURRENT' FLORIDA BUILDING CODE (FBC). INCLUDING HVHL 2. MULLION TEST EVALUATED IN ACCORDANCE WITH TAT 201-94, TAS 202-94 AND TAS 203-94 AS REPORTEDIN AR REPORT B: 0722.01-Ok NCR REP ORrO NCTL-2143587.2 & NCR-2103850-L 3. SEPARATE MULLION INSTALLATION DETAILSAPPLY TO SHWINCOARCHITECTURAL PRODUCTS, LUC SERIES 2 ALUMINUM MULLION. DETAILS 11 & 2 APPLYTO SERIES 2 MULLION INSTALLED WITH ALUMINUM ANCHOR CUPS. DETAIL93 APPLIES 10 SERIES 2 MULLION IN 'NON -CUPPED- INSTALLATION APPLICATION. 4. APPROVED IMPACT PROTECTME SYSTEM 5 NOT REQUIREDON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE S. USE TWO (2) VU WOOD SCREWS PER CUP OF SUFFICIENT LENGTH M ACHIEVE MINIMUM EMBEDMENT OF 1 in INCH INTO WOOD FRAMING. 6. USE ONE (1) 1/4 INCH ELCO TAPCON SCREWS (OR EQUAL) PER CUP OF SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF 11/4- INTO CONCRETE/MASONRY. 7. 11L AND 2K WOOD BUCKS m BE DESIGNED ANDANCHORED TO PROPERLY TRMIFER ALL LOADSTO STRUCTURE AND IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. S. THIS MULLION IS ONLY VALID WHEN USED IN CONJUNCTION WITH APPLICABLE SHWINCO ARCHITECTURAL PRODUCTS, LLC WINDOW PRODUCTS. 9. ALLOWABLE PRESSURES 8, SIM ON MULLED ASSEMBLIES SHALL BE UMITED 70 THE LESSER DESIGN PRESSURE AND SUES OF TH E APPROVED MULLION OR INDIVIDUAL UNIT INSTALLATION - 10. MULLION AND CUP MATERWL 6063-15 ALUMINUM. 12. INSTAUATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE EASED ON SUBSTRATE MATERIALS WITH THE FOUOWING PROPERTIES: WOOD - MINIMUM SPECIFIC GRAWW OF 0.55. CONCRETE -MINIMUM COMPRESSNESTRENGTH OF 2700 PST. MASONRY -STRENGTH CONFORMANCETOASTM 093 12. DESIGNATIONS°%' AND'O'STANDFORTHEFOUOWING: K:OPERABLEPANEL 0: FIXED PANEL cn -I W\/ ®Fn 0 W T ® MAX DP+50/-50 z Z m 40 m SHWINCO ARCHITECTURAL PRODUCTS, INC. SERIES 2 MULLION (IMPACT) DESIGN PRESSURE RATING DETAIL DESIGN PRESSURET MLSSII£IMPAR RACING 1&2 +50/-SD PSF SMALLAND LARGE MISSILE IMPACT RATED' 3 460/-70 PSF SMALLAND LARGE MISSILE IMPACT RATED DETAIL 2 CLIPPED MULLION MAX DP+50/-50 TABLE OF CONTENTS SHEET NEVLSION. . SHEETDESCRIPncN 1 A MULL ION ASSEMBLY ELEVATIONS AND NOTES 2 A -MUWONSECTIONDETAILSANOANCHORING 3 A MULLION SECTION DEFALSANDANCHORING DETAIL 3' UNCLIPPED MULLION MAX DP+601-70 -* STATE OF SERIES 2 MULLION (LMI)' MULLION ASSEMBLY ELEVATIONS AND NOTES PREPARED FOR: SHWINCO ARCHITECTT/RAL PRODUCTS;LLC. DATE: 4-22-15 DRN BY: KITS CHK BY: CDS SCALE: NTS REVISIONS I Q 0 Z SAP.M.1001 SHEET: 1 OF 3 RANDALL E. r u ORT.ARCHITECTS, pJL APA03379 ' AF=11105 P1 APPROVED REVISE & RESUBMIT E] APPROVED!-.a.n9PjF CTEED REJECTED ThIS rmijgy F; F' n: co v,,b -aiiq resign concept of the In t cn tr ,;p J, -c act drmwings during vith'&is require- n shall not WmDflnerd. Can- a,,, wrcl&d at the i;jr, jakon , sZsses of 10 "m P-c S30 onces and pjaceduies Of construe- ` ton: oft• 6 v4o-" of a!] aer odes: and for performing all work in a sea and satsfar.,Lo mapar. ry DATE: BY: