Loading...
HomeMy WebLinkAboutTruss4451 ST. LUCIE BLVD FORT PIERCE, FL 34946 P H : 772-409-1010 FX: 772-409-1015 www.AlTruss.com TRUSS ENGINEERING BUILDER: 7RM CONSTR. PROJECT: AVALON 2-STORY .Y FCOUNTY: INDIAN RIVER w H LOT/BLK/MODEL: LOT:25 / MODEL:2 STORY u 'I REVIEWED FOR 0-,'CODE COMPLIANCE JOB#: 76199 ST. LUCIE COUNTY — ` BOCC MASTER#: WTRMAV2 OPTIONS: NO OPTIONS FlL'L'mCGPY / Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 �. f A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A.FLORIDA CORPORATION RE: Job WTRMAV2 Site Information: Customer Info: TRM CONSTRUCTION Project Name: AVALON 2-STORY Lot/Block: Model: 2 STORY Address: OCEAN ESTATES DRIVE, VERO BEACH Subdivision: City: County: Indian River A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946 �— State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 170 Roof Load: 55.0 psf Floor Load: 65.0 psf This package includes 69 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. r- � w a w �_ ,a co �F-z-off co 0u-000 �i`n Z 0 Cl) U LL to 000- LU— o �z(D �QOCD= w 0� wCLLW�co Ll—�va t`nn Z0z��l>nCc Q Q Z 0 Z O Q m 0� ()Q2Z1--o-O Um� OZtjQ— QOXLu<r- JWErCcCO a3cc CO 0�D CD 0 Ir 16 QUWuJ ® a�rn rn co r` No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0261113 A01 6/27/19 13 A0261125 CA 6127/19 25 A0261137 CJ5A 6/27/19 2 A0261114 A02 6/27/19 14 A0261126 CJ1A 6/27/19 26 A0261138 CJ5B 6/27/19 3 A0261115 A03 6127/19 15 A0261127 CAB 6/27/19 27 A0261139 CJ5W 6/27/19 4 A0261116 A04 6/27/19 16 A0261128 CAC 6/27/19 28 A0261140 D01 6/27/19 5 A0261117 A05 6/27/19 17 A0261129 CAD 6/27/19 29 A0261141 D02 6/27/19 6 A0261118 A06 6/27/19 18 A0261130 CAW 6/27/19 30 A0261142 D03 6/27/19 7 A0261119 A10 6/27/19 19 A0261131 CJ3 6127/19 31 A0261143 D04 6/27/19 8 A0261120 B01 6/27/19 1 20 A0261132 CJ3A 6/27/19 32 A0261144 D05 6/27/19 9 A0261121 B02 6/27/19 21 A0261133 CJ313 6/27/19 33 A0261145 D06 6/27/19 10 A0261122 B03 6/27/19 22 A0261134 CJ3C 6/27/19 34 A0261146 D07 6/27/19 11 A0261123 C01 6/27/19 23 A0261135 CJ3W 6/27/19 35 A0261147 D08 6/27/19 12 A0261124 I CO2 6/27/19 24 A0261136 CJ5 6/27/19 36 A0261148 I D09 6/27119 The truss dravAng(s) referenced have been prepared by MiTek Industries, Inc. under mydirect supervision based on the parameters provided bvA-1 Roof Trusses. Ltd. Truss Design Engineer's Name: Manuel Martinez My license renewal date for the state of Florida is February 28,2021. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solelyforthe truss components shown. The suitability and use of components forany particular building is the responsibility of the building designer, perANSIMPI-1 Sec. 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to at times as'Structural Engineering Documents) provided bythe Building Designer indicating the nature and characterof the work The design criteria therein have been transferred to Manuel Martinez PE by [Al Roof Trusses orspec'fiic location]. These TDDs (also referred to attimes as'Structural Delegated Engineering Documents) are specialty structural component designs and may be part of the projecfs deferred orphased submittals. As aTuuss Design Engineer(i.e, specialty Engineer), the seal here and on the TDD represents an acceptance of professional engineering responsibilityforthe design ofthe single Truss depicted on the TDD only. The Building Designeris responsible forand shall coordinate and review the TDDs for compatibility with the'rwdtten engineering requirements. Please review all TDDs and all related notes. Manuel t' Digitally signed by Manuel Mattinez DN: c=US, o=M and E Associates �45tiNALrIHt/r�p(6 Ma ez O1A�n=Man016ABAtinez 0 d �t1;tn=Manuel Martinez DA. - 9.06.2715:5852-04'00' No 47182 "» 95 STR � 8 C1F r� b �'F '�dj85''airarAr �t'�*` 5E FB A5 F83 1812 BC78 10 52 849E ACES CA Manuel Martinez, P.E. tf 4620 ParkView Dr. St Cloud, FL 34771 Page 1 of 2 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 A-1 ROOF These truss -designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE: Job WTRMAV2 No. . Seal # Truss Name. Date No. Seal # Truss Name Date 37 A02611149 D10 6/27/19 75 STDL06 STD. DETAIL . 6/27/19 38 A0261150 D11 6/27/19 76 STDL07 STD. DETAIL 6/27/19 39 A0261151 : D12", 6/27/19 77 STDL08 STD. DETAIL 6/27/19 40 M261152 D13 6/27119 78 STDL09 STD. DETAIL 6/27/19 41 A0261153 D14 6/27/19 79 STDL10 STD. DETAIL '6/27/19 42 A0261154 - `D15 6/27/19 80 STDL11 STD. DETAIL 6/27/19 43 A0261155 D16 6/27/19 81 STDL12 STD. DETAIL 6/27/19 44 A0261156 , F01 ' 6/27/19 82 STDL13 STD. DETAIL 6/27/19 45 =A0261157 F02 6/27/19 83 STDL14 STD. DETAIL 6/27/19 46 A0261158 F03 6/27/19 84 STDL15 STD. DETAIL 6/27/19 47 A0261159 ._ F04 '. 6/27/19 85 STDL16 STD. DETAIL 6/27119 48 A0261160 F05 6/27/19 49 A0261161 F06 6/27/19 50 A0261162 FG01 6/27/19 51 A0261163 FG02 6/27/19 52 A0261164 FG63 6/27/19 53 A0261165 FG04 6/27119 54 A0261166 FG05 6/27/19 55 A0261167 HJ3 6/27/19 56 A0261168 HJ3A 6/27/19 57 A0261169 HJ5 6/27/19 58 A0261170 HJ7 6/27/19 59 A0261171 HJ7B 6127/19 60 A0261172 HJ7C 6/27/19 61 A0261173 HJ7W 6/27/19 62 A0261174 J3 6/27/19 63 A0261175 J3A 6/27/19 64 A0261176 J5 6127/19 65 A0261177 J7 6/27/19 66 A0261178 J713 6/27/19 67 A0261179 J7C 6/27/19 68 A0261180 J7W 6/27/19 69 A0261181 VM02 6/27/19 70 STDL01 STD. DETAIL_ 6/27/19 71 STDL02 .STD. DETAIL 6/27119 72 STDL03_ ; .,. STD. Dt_ AIL 6/27/19 73 STDL64 ' - ',;-8,TD. DE"F4IL - 6/27/19 74 STDL05 STD.BETAIL.., 6/27/19 Page 2 of 2 Job Truss Truss Type Qty Ply A0261113 WTRMAV2 A01 Hip Girder 1 1 Job Reference (optional) A-1+R001l nlsses, Fort Pierce, i-L 3494b, design(cal truss.com KUn: b.Z1U s may 1b zu1S Print: t3.Z1U s May ib ZUIb Mi i eK incustnes, Inc. Wed Jun Zb 13:9b:4b ZU1U ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-NUwrSMEzU91f?MJS8U9w8pA_mjJ WpApkoEds: -0-618 7-0-0 15-0-0 22-6-0 1 25-7-2 1 29-6-0 30-0,8 7-0-0 7x8 = 7-0-0 4x6 = 3x10 11 6x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.19 8-9 >921 360 TCDL 15.0 Lumber DOL 1.25 BC 0.43 Vert(CT) -0.23 9-11 >776 240 BCLL 0.0 Rep Stress Incr NO WB 0.78 Horz(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 *Except* T2: 2x6 SP 2400F•2.OE BOT CHORD 2x6 SP 240OF 2.0E WEBS 2x4 SP No.3 *Except* W2,W3: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-6-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 4-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except Ot=length) 6= 1 -0-0, 6= 1 -0-0. (lb) - Max Horz 2= 68(LC 40) Max Uplift All uplift 100 lb or less at joint(s) except 2=-702(LC 4), 9=-3065(LC 4), 6=-1014(LC 5) Max Grav All reactions 250 lb or less at joint(s) except 2=1324(LC 19), 9=4316(LC 1), 6=1227(LC 20), 6=1222(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3084/1524, 3-16=-2855/1494, 16-17=-2857/1495, 17-18=-2859/1496, 18-19=-2863/1497, 4-19=-2865/1498, 4-20=-2543/2551, 20-21=-2540/2550, 21-22=-2536/2549, 5-22=-2534/2548, 5-6=-2750/2613 BOT CHORD 2-23=-1361/2834, 2-24=-1374/2852, 11-24=-1374/2852, 11-25=-478/398, 25-26=-478/398, 26-27=-478/398, 10-27=-478/398, 10-28=-478/398, BOT CHORD 2-23=-1361/2834, 2-24=-1374/2852, 11-24=-1374/2852, 11-25=-478/398, 25-26=-478/398, 26-27=-478/398, 10-27=-478/398, 10-28=-478/398, 9-28=-478/398, 9-29=-478/398, 29-30=-478/398, 30-31=-478/398, 8-31=-478/398, 8-32=-2349/2534, 6-32=-2349/2534, 6-33=-2335/2515 WEBS 3-11=-6/549, 4-11=-1800/3446, 4-9=-3440/2533, 4-8=-2880/3132, 5-8=-220/483 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 702 lb uplift at joint 2, 3065 lb uplift at joint 9 and 1014 lb uplift at joint 6. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. PLATES MT20 Dead Load Defl. = 1/16 in 3x4 = GRIP 244/190 Weight: 159 Ib FT = 10% 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 279 lb down and 339 lb up at 7-0-0, 138 lb down and 187 lb up at 9-0-12, 138 lb down and 187 lb up at 11-0-12 , 138 lb down and 187 lb up at 13-0-12, 138 lb down and 187 lb up at 14-6-0, 138 lb down and 200 lb up at 16-5-4, 138 lb down and 200 lb up at 18-5-4, and 138 lb down and 200 lb up at 20-5-4, and 280 lb down and 368 lb up at 22-6-0 on top chord, and 629 lb down and 359 lb up at 7-0-0, 274 lb down and 58 lb up at 9-0-12, 274 lb down and 58 lb up at 11-0-12, 274 lb down and 58 lb up at 13-0-12, 274 lb down and 58 lb up at 14-6-0, 274 lb down and 221 lb up at 16-5-4, 274 lb down and 221 lb up at 18-5-4, and 274 lb down and 221 lb up at 20-5-4, and 629 lb down and 777 lb up at 22-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pif) Vert: 1-3=-90, 3-5=-90, 5-7=-90, 2-6=-20 Concentrated Loads (lb) Vert: 3=-208(F) 5=-209(F) 11 =-626(F) 8=-589(F) 16=-138(F) 17=-138(F) 18=-138(F)19=-138(F) 20=-138(F) 21=-138(F) 22=-138(F) 25=-132(F) 26=-1 32(F) 27=-1 32(F) 28=-1 32(F) 29=-1 32(F) 30=-132(F) 31=-132(F) Job Truss Truss Type Qty Ply WTRMAV2 A02 Hip 1 1 ' A0261114 Job Reference (optional) m- i muoi i russes, run rierce, rL awavo, eesignLa-iiruss.com 3-6-2 4.00 F12 4x4 = Kun: ts.z1 u s May io zuiu vnnt: ts.z1 u s May Id 2U18 MI I eK Industries, Inc. Wed Jun 26 13:36:47 20tg ID:YwMtazYTmRGkHb8J_pTy?Kyn003-rhUEfiFbFS9WcVufhBh9h0i7p7aQYc7u1 uNP 1-9-0 20-6-0 24-0-2 29-6-0 3 -0 I-9-0 5-9-0 3-6-2 5-5-14 -6- 3x10 = 4x4 = Dead Load Defl. = 3/16 in 4x4 = 3x10 = 3x6 11 3x6 = 3x10 = 4x4 Plate Offsets LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-2-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation ouide. REACTIONS. All bearings 0-8-0 except Qt=length) 8=1-0-0, 10=0-3-8. (lb) - Max Horz 2= 86(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 2=-356(LC 8), 13=-911(LC 8), 8=-334(LC 31), 10=-265(LC 9) Max Grav All reactions 250 lb or less at joint(s) 8 except 2=705(LC 23), 13=1954(LC 1), 10=810(LC 31) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1222/1033, 3-4=-628/470, 4-5=-526/490, 5-6=-447/427, 6-7=-536/398, 7-8=-1 0 10/870 BOT CHORD 2-21=-354/457, 2-22=-840/1133, 14-22=-840/1133, 14-23=-778/868, 13-23=-778/868, 12-13=-778/868, 12-24=-778/868, 11-24=-778/868, 11-25=-671/890, 10-25=-671/890, 8-1 0=-671/890 WEBS 3-14=-663/791, 4-14=-198/258, 5-14=-1110/1361, 5-13=-1858/1689, 5-11=-1040/1256, 6-11=-264/302, 7-11=-482/666 20-6-0 CSI. DEFL. in (loc) I/deft Ud TC 0.67 Vert(LL) -0.2814-17 >629 360 BC 0.71 Vert(CT) -0.4614-17 >388 240 WB 0.84 Horz(CT) 0.01 8 n/a n/a Matrix -MS WEBS 3-14=-663/791, 4-14=-198/258, 5-14=-1110/1361, 5-13=-1858/1689,' 5-11 =-1 040/1256, 6-11=-264/302, 7-11=-482/666 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 356 lb uplift at joint 2, 911 lb uplift at joint 13, 334 lb uplift at joint 8 and 265 lb uplift at joint 10. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES MT20 GRIP 244/190 Weight: 133 Ib FT = 10% V A A iM 0 Job Truss Truss Type city Ply A0261115 WTRIVIAV2 A03 Hip 1 1 Job Reference (optional) A-14Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:48 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-Jt2ct2GDOmHNEfrrFvCODEFGOX rH541FY6zWiz2PdD 1F_Q_6t8 5-5-1 11-0-0 14-9-0 1 18-6-0 24-0-14 29-6-0 39-0r8 -6- 5-5-1 5-6-14 3-9-0 3-9-0 5-6-15 5-5-2 -6- 4x6 = 3x10 = 46 = Dead Load Def. =1/4 in 3x6 = 3x10 = 3x6 = 3x6 II 3x10 = 3x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.74 Vert(LL) -0.38 14-17 >463 360 TCDL 15.0 Lumber DOL 1.25 BC 0.50 Vert(CT) -0.65 14-17 >273 240 BCLL 0.0 Rep Stress Incr - YES WB ' 0.73 Horz(CT) 0.01 8 n/a n/a BCDL 10.0 Code FBC2017/71312014 Matrix -MS LUINBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except Qt=length) 8=1-0-0, 10=0-3-8. (lb) - Max Horz 2=-104(LC 13) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-322(LC 8), 12=-959(LC 8), 8=-449(LC 31), 10=-111(LC 9) Max Grav All reactions 250 lb or less at joint(s) 8 except 2=680(LC 23), 12=2059(LC 1), 10=900(LC 31) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1190/928, 3-4=-250/130, 7-8=-1006/845 BOT CHORD 2-21=-331/484, 2-22=-752/1115, 14-22=-752/1115, 14-23=-916/1127, 13-23=-916/1127, 12-13=-916/1127, 12-24=-916/1127, 11-24=-916/1127, 11-25=-667/902, 10-25=-667/902, 8-10=-667/902, 8-26=-280/45 WEBS 3-14=-1013/1197, 4-14=-399/489, 5-14=-1014/1240, 5-12=-2071/1789, 5-11=-985/1164, 6-11=-437/504, 7-11=-834/1126 NOTES- 1) Unbalanced roof live.loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live. load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 322 lb uplift at joint 2, 959 lb uplift at joint 12, 449 lb uplift at joint 8 and 111 lb uplift at joint 10. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES MT20 GRIP 244/190 Weight: 138 Ib FT = 10% 0 Job Truss Truss Type Qty Ply WTRMAV2 AO4 Hip 1 1 0 ` A0261116 Job Reference (optional) ,v- i mom i russes, rorr coerce, rL a4e4o, oesignLaliruss.com Kun: ts.L1u s May ib [nits runt: 6.21u s May 18 2U18 MITek Industries, Inc. Wed Jun 26 13:36:49 201+9 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-n3c_4OGm4PEsp21 pcjdmRoP4xIHObtBUCsW2 14-9-0 , 16-6-0 , 22-10-1 2g-6-n sn-n. 4x6 = 1.5x4 11 4x6 = Dead Load Deft. = 1116 in 4x6 = 4x4 = 5x8 = 4x4 = 4x6::::: 6-7-15 LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017ITP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 8-1-8 oc bracing: 2-13. WEBS 1 Row at midpt 4-13, 6-11 MITek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except (jt=length) 8=1-0-0, 10=0-3-8. (lb) - Max Horz 2= 123(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 2=-308(LC 8), 12=-937(LC 8), 8=-239(LC 31), 10=-419(LC 9) Max Grav All reactions 250 lb or less at joint(s) 8 except 2=615(LC 23), 12=2222(LC 1), 10=701(LC 24) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-912/608, 3-4=-968/900, 4-5=-679/1049, 5-6=-679/1049, 6-7=-777/678, 7-8=-759/408 BOT CHORD 2-20=-261/380, 2-21=-418/821, 13-21=-418/821, 13-22=-635/799, 12-22=-635/799, 12-23=-650/815, 11-23=-650/815, 11-24=-224/643, 10-24=-224/643, 8-10=-224/643 WEBS 3-13=-654/858, 4-13=-1472/1487, CSI. DEFL. in (loc) I/deft L/d TC 0.88 Vert(LL) -0.2612-13 >672 360 BC 0.62 Vert(CT) -0.3411-12 >493 240 WB 0.57 Horz(CT) 0.01 8 n/a n/a Matrix -MS WEBS 3-13=-654/858, 4-13=-1472/1487, 4-12=-1113/1114, 6-12=-1072/1072, 6-11=-1240/1262, 7-11=-587/789 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extenor(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS, for reactions shown; Lumber DOL=1,60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 376-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 308 lb uplift at joint 2, 937 lb uplift at joint 12, 239 lb uplift at joint 8 and 419 lb uplift at joint 10. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES MT20 GRIP 244/190 Weight: 139 Ib FT = 10% Job Truss Truss Type Qty Ply A0261117 WTRMAV2 A05 Common 1 1 Job Reference (optional) A-VRoof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:50 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-FGAMIkHUYNY4TzdENKEslfKY3Ldil1 KKjsb3bbz2PdS -11 -Q-6T8 6-7-15 14-9-0 22-10-1 29-6-0 30-Or8 6- 6-7-15 8-1-1 8-1-1 6-7-15 -6- 4.00 12 5x10 MT20HS= Dead Load Deft. = 1116 In 3x8 = 1.5x4 11 5x8 = 1.5x4 11 3x8 = LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017ITP12014 LUMBER - TOP CHORD 2x4 SP No.2 *Except` T1: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-1213-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except (jt=length) 8=1-0-0, 10=0-3-8. (lb) - Max Horz 2=138(LC 16) Max Uplift All uplift 100 lb or less at joint(s) except 2=-300(LC 8), 12=-924(LC 8), 8=-203(LC 31), 10=-299(LC 9) Max Grav All reactions 250 lb or less at joint(s) 8 except 2=614(LC 23), 12=2244(LC 1), 10=607(LC 31) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-971/639, 3-4=-694/839, 4-5=-681/1047, 5-6=-683/1049, 6-7=-696/888, 7-8=-857/496 BOT CHORD 2-20=-258/385, 2-21=-461 /890, 13-21=-461/890, 13-22=-461/890, 12-22=-461/890, 12-23=-316/752, 11-23=-316/752, 11-24=-316/752, 10-24=-316/752, 8-10=-316/752 WEBS 5-12=-1268/1232, 7-12=-1441/1465, 7-11=01331, 3-12=-1607/1618, 3-13=0/355 CSI. DEFL. in (loc) I/deft L/d TC 0.99 Vert(LL) -0.2612-13 >673 360 BC 0.60 Vert(CT) -0.3411-12 >493 240 WB 0.62 Horz(CT) 0.03 8 n/a n/a Matrix -MS NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 300 lb uplift at joint 2, 924 lb uplift at joint 12, 203 lb uplift at joint 8 and 299 lb uplift at joint 10. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 129 Ib FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 A06 Common 5 1 Lb` (, A0261118 Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:51 2099 Page 1 ID:YwMtazYTmRGkHb8J_rTy?Kyn003-kSkkV416Jhgx57BQwll5rstl?kw2UV UxWLd71z2PdA ()-6i8 7-7-13 14-9-0 21-10-3 29-6-0 30-0'8 0-6-8 7-7-13 7-1-3 7-1-3 7-7-13 0-6-18 4.0012 5x10 MT20HS= Dead Load Defl. = 5/16 in 3x4 = 5x10 MT20HS= 3x4 = 3x8 = M = LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-8-8 oc bracing. WEBS 1 Row at midpt 5-10, 5-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1667/0-8-0 (min.0-1-15) 8 = 1667/0-8-0 (min. 0-1-15) Max Horz 2 = 138(LC 12) Max Uplift 2 = -768(LC 8) 8 = -768(LC 9) Max Grav 2 = 1667(LC 1) 8 = 1667(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4009/3569, 3-4=-3595/3256, 4-5=-3481 /3277, 5-6=-3481 /3277, 6-7=-3595/3256, 7-8=-4009/3568 BOT CHORD 2-19=-118711372, 2-20=-3213/3752, 12-20=-3213/3752, 12-21 =-1 902/2440, 11-21=-190212440, 11-22=-1902/2440, 10-22=-1902/2440, 10-23=-3216/3752, 8-23=-3216/3752, 8-24=-1193/1372 WEBS 5-10=-1003/1214, 7-10=-756/959, 5-12=-1003/1214, 3-12=-756/959 CSI. DEFL. in (loc) I/defi L/d TC 0.85 Vert(LL) -0.5010-12 >704 360 BC 0.79 Vert(CT) -0.8210-12 >432 240 WB 0.46 Horz(CT) 0.12 8 n/a n/a Matrix -MS NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 768 lb uplift at joint 2 and 768 lb uplift at joint 8. 7) This truss has been designed for a moving concentrated load of 200.0lb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 122 Ib FT = 10% Job Truss Truss Type Qty Ply A0261119 WTRMAV2 A10 JACK -OPEN GIRDER 1 1 Job Reference (optional) A-i1Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:51 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-kSkkV416Jhgx57BQw115rsttwkvDUcfUxWLd71 z2PdA 3-0-0 3-0-0 LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-7-2 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 977/0-8-0 (min. 0-1-8) 3 = 643/Mechanical Max Horz 1 = 123(LC 8) Max Uplift 1 = -372(LC 8) 3 = -320(LC 8) Max Grav 1 = 977(LC 1) 3 = 643(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 372 lb uplift at joint 1 and 320 lb uplift at joint 3. 5x6 = 3-0-0 2x4 11 CSI. DEFL. in (loc) I/deft Ud TC 0.34 Vert(LL) -0.02 3-6 >999 360 BC 0.84 Vert(CT) -0.03 3-6 >999 240 WB 0.04 Horz(CT) 0.01 1 n/a n/a Matrix -MP 6) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1306 lb down and 548 lb up at 1-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-90, 3-4=-20 Concentrated Loads (lb) Vert: 7=-1306(B) PLATES GRIP MT20 244/190 Weight: 15 lb FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 B01 Monopitch 14 1 ' A0261120 Job Reference (optional) A-i Roof Trusses, Fort Pierce, FL 34946, cesignLaltruss.com Kun: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:52 20% Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-CeH7jPJk4_ooj HmcUIGKN4P2B8NND3SdAA5AfTz2Pd9 4-6-0 0-6-8 ' 4-6-0 3 3x4 = 3x4 = 4-6-0 Plate Offsets LOADING(psf) SPACING- 2-0-0 CS'. DEFL. in floc) I/deft Ud TCLL 30.0 Plate Grip DX 1.25 TC 0.37 Vert(LL) -0.04 4-7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.34 Vert(CT) -0.06 4-7 >860 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 271/0-8-0 (min. 0-1-8) 4 = 221/0-3-0 (min. 0-1-8) Max Horz 2 = 118(LC 8) Max Uplift 2 = -145(LC 8) 4 = -125(LC 12) Max Grav 2 = 317(LC 25) 4 = 301(LC 27) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-161/267 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf, h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 145 lb uplift at joint.2 and 125 lb uplift at joint 4. 6) This truss has been designed for a moving . concentrated load of 200.01b live located at all mid panels and at all panel. points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 18 lb FT = 10% Job Truss Truss Type Qty Ply AO261121 V TRMAV2 B02 Monopitch 7 1 Job Reference (optional) A -*Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:53 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-grrVwlJMrlwfKQLo2SnZwHyBJYINyWimPggkBvz2Pd8 -0-6-8 5-2-0 0-6-8 5-2-0 5x6 = 3X4 = 3x4 = 1-0-0 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) -0.03 5-12 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.22 Vert(CT) -0.03 5-12 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 , 5 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = -64/1-0-0 (min. 0-1-8) 5 = 167/0-3-0 (min. 0-1-8) 3 = 535/0-3-8 (min. 0-1-8) Max Horz 2 = 155(LC 8) Max Uplift 2 = -192(LC 25) 5 = -95(LC 8) 3 = -312(LC 12) Max Grav 2 = 156(LC 26) 5 = 276(LC 29) 3 = 535(LC .1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-251/91, 4-5=-144/256 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf, h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing atjoint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 192 lb uplift at joint 2, 95 lb uplift at joint 5 and 312 lb uplift at joint 3. 6) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 21 lb FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 B03 Half Hip Girder 1 1 ' A0261122 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL j454t5, design(o_)altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:54 2099 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-81 Pt75K_bc2Wyaw?cAJoTWR6y4LhzJweUaHkMz2Pd7 -0-6-8 3-0-0. 4-4-0 0-6-11 3-0-0 1-4-n 3x4 LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 * Rep Stress Incr NO BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 *Except* W1: 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 41/1-0-0 (min. 0-1-8) 3 = 384/0-3-8 (min. 0-1-8) 15 = 146/0-3-0 (min. 0-1-8) Max Horz 2 = 113(LC 4) Max Uplift 2 = -186(LC 21) 3 = -236(LC 8) 15 = -132(LC 4) Max Grav 2 = 136(LC 23) 3 = 599(LC 21) 15 = 338(LC 27) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-62/331 WEBS 5-15=-354/138 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. CSI. DEFL. in (loc) I/defl Ud TC 0.15 Vert(LL) -0.02 7-14 >999 360 BC 0.30 Vert(CT) -0.02 7-14 >999 240 WB 0.04 Horz(CT) -0.00 15 n/a n/a Matrix -MP 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in, all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 lb uplift at joint 2, 236 lb uplift at joint 3 and 132 lb uplift at joint 15. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 62 lb down and 87 lb up at 3-10-12, and 53 lb down and 77 lb up at 3-0-0 on top chord, and 200 lb down and 18 lb up at 3-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-9=-90, 3-4=-90, 7-11=-20 Concentrated Loads (lb) Vert: 4=-38(F) 5=-62(F) 7=-21(F) PLATES GRIP MT20 244/190 Weight: 17 lb FT = 10% Job Truss Truss Type Qty Ply A0261123 WTRMAV2 C01 Half Hip Girder 1 1 Job Reference (optional) A-IA'Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:55 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-cDzFLRLcMvANakVB9tg1?i1 UhMHLQGu3s8JgGoz2Pd6 -1 4-0 , 7-0-0 12-2-0 17-4-0 1-4-0 7-0-0 5-2-0 5-2-0 3x4 = vxo — 2x4 1I 3x8 = 10x10 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.68 Vert(LL) 0.12 9-11 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.89 Vert(CT) -0.14 9-11 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.66 Horz(CT) 0.04 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-5-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 5-4-12 oc bracing. WEBS 1 Row at midpt 4-6 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1811/0-8-0 (min. 0-2-2) 6 = 2293/Mechanical Max Horz 2 = 347(LC 8) Max Uplift 2 = -1078(LC 8) 6 = -1559(LC 5) Max Grav 2 = 1811(LC 1) 6 = 2293(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2844/1741,3-12=-2347/1623, 12-13=-2347/1623, 4-13=-2347/1623, 5-6=-507/447 BOT CHORD 2-16=-1580/2288, 2-17=-1619/2329, 9-17=-1619/2329, 8-9=-1361/2000, 8-18=-1361/2000, 18-19=-1361/2000, 7-19=-1361/2000, 7-20=-1361/2000, 20-21=-1361/2000, 21-22=-1361/2000, 6-22=-1361/2000 WEBS 3-9=-182/566,4-9=-397/447,4-7=-28/448, 4-6=-2527/1718 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Concentrated loads from layout are not present in Load Case(s): #101 1st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load; #801 8th Moving Load; #901 9th Moving Load. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) . This truss has been designed for a live load of 20.Opsf, on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7.) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1078 lb uplift at joint 2 and 1559 lb uplift at joint 6. 9) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 335 lb down and 495 lb up at 7-0-0, 292 lb down and 267 lb up at 9-0-12, 292 lb down and 267 lb up at 11-0-12 , 292 lb down and 267 lb up at 13-0-12, and 292 lb down and 267 lb up at 15-0-12, and 268 lb down and 261 lb up at 17-2-4 on top chord, and 481 lb down and 336 lb up at 7-0-0, 94 lb down and 36 lb up at 9-0-12, 94 lb down and 36 lb up at 11-0-12, 94 lb down and 36 lb up at 13-0-12, and 94 lb down and 36 lb up at 15-0-12, and 112 lb down and 27 lb up at 17-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11 Dead Load Defl. = 1/16 In PLATES GRIP MT20 244/190 Weight: 105 Ib FT = 10% LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90, 3-5=-90, 2-6=-20 Concentrated Loads (lb) Vert: 3=-264(B) 5=-217(B) 8=-84(B) 9=-481(B) 6=-92(B)12=-178(B) 13=-178(B)14=-178(B) 15=-178(B) 19=-84(B) 20=-84(B) 22=-84(B) Job Truss Truss Type Qty Ply WTRMAV2 CO2 Roof Special Girder 1 1 ` A0261124 Job Reference (optional) A-1 Koot I cusses, tort Pierce, 1-L 3454b, deslgn(aal truss.com Run: 6.210 s May 16 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:56 2019 4-4-0 5x6 11 1.5x4 II 3x8 = 3x10 11 4%b = 7x8 = 10x10 = Dead Load Defl. = 1/16 in 7-0-0 11-4-0 12-4-5 17-4-0 7-0-0 4 4-0 1-0-8 4-11-8 Plate Offsets (X,Y)-- [2:0-9-4,0-1-51 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.89 Vert(LL) 0.12 10-12 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.84 Vert(CT) -0.14 10-12 >999 240 BCLL 0.0 * Rep Stress Incr NO WB 0.70 Horz(CT) 0.03 7 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 112 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 5-8-8 oc bracing. WEBS 1 Row at midpt 5-7 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 7 = 1422/Mechanical 2 = 1669/0-8-0 (min. 0-2-0) Max Horz 2 = 392(LC 36) Max Uplift 7 = -811(LC 5) 2 = -952(LC 8) Max Grav 7 = 1422(LC 1) 2 = 1669(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2556/1494, 3-13=-1617/974, 4-13=-1617/974, 4-5=-1913/1196 BOT CHORD 2-14=-1413/2041, 2-15=-1451/2081, 10-15=-1451/2081, 9-10=-1466/2111, 8-9=-1466/2111, 8-16=-745/1206, 7-16=-745/1206 WEBS 3-10=-424/836, 3-8=-689/624, 4-8=-1217/851, 5-8=-1235/1845, 5-7=-1652/1028 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Concentrated loads from layout are not present in Load Case(s): #101 1st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load; #801 8th Moving Load; #901 9th Moving Load. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 811 lb uplift at joint 7 and 952 lb uplift at joint 2. 9) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 409 lb down and 497 lb up at 7-0-0, and 295 lb down and 274 lb up at 9-0-12 on top chord, and 551 lb down and 378 lb up at 7-0-0, and 93 lb down and 36 lb up at 9-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90, 3-4=-90, 4-5=-90, 5-6=-90, 2-7=-20 Concentrated Loads (lb) Vert: 3=-264(F) 9=-85(F) 10=-551(F) 13=-187(F) Job Truss Truss Type Qty Ply A0261125 WTRMAV2 CA Corner Jack 3 1 Job Reference (optional) A-11ROOf Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:57 2019 Page 1 I D:YwMtazYTmRGkHbBJ_pTy?Kyn003-Yc50m7NtuXQ5p2faHIsV477_A99auKhMKSoxKhz2Pd4 -0-6-8 , 9-11- 1 0-6-8 0-11-11 4.00 12 2x4 = LOADING(psf) SPACING- 2-0-0 CSI. TCLL 30.0 Plate Grip DOL 1.25 TC 0.04 TCDL 15.0 Lumber DOL 1.25 BC 0.01 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 0-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 108/0-8-0 (min. 0-1-8) 4 = 34/Mechanical Max Horz 2 = 41(LC 8) Max Uplift 2 = -84(LC 8) 4 = -22(LC 12) Max Grav 2 = 108(LC 1) 4 = 34(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 84 lb uplift at joint 2 and 22 lb uplift at joint 4. DEFL. in (loc) I/defl Ud PLATES GRIP Vert(LL) -0.00 5 >999 360 MT20 244/190 Vert(CT) -0.00 5 >999 240 Horz(CT) 0.00 4 n/a n/a Weight: 4 lb FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 CJ1A Corner Jack 1 1 A0261126 Job Reference (optional) A-i moor Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 2613:36:57 20$9 Page 1 I D:YwMtazYTm RG kHb8J_pTy?Kyn003-Yc5Om7 Ntu XQ5p2faH I sV477zH96Tu Kh M KSoxKhz2Pd4 -0-6-8 0-11-11 0-6-8 0-11-11 4.00 12 2x4 = LOADING (psf) SPACING- 2-0-0 CS'. DEFL. in (loc) I/deft Ud TCLL 30.0 Plate Grip DX 1.25 TC 0.09 Vert(LL) 0.00 2 n/r 120 TCDL 15.0 Lumber DOL 1.25 BC 0.21 Vert(CT) 0.00 2 n/r 80 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 0-11-11 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 158/0-11-8 (min. 0-1-8) 4 = -13/0-11-8 (min. 0-1-8) Max Horz 2 = 53(LC 8) Max Uplift 2 = -155(LC 8) 4 = -13(LC 1) Max Grav 2 = 158(LC 1) 4 = 16(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 155 lb uplift at joint 2 and 13 lb uplift at joint 4. 5) Non Standard bearing condition. Review required. PLATES GRIP MT20 244/190 Weight: 4 lb FT = 10% Job Truss Truss Type Qty Ply WfRMAV2 CJ1B Corner Jack 3 1 A0261127 Job Reference (optional) A-1'Roof Trusses, Fort Pierce, FL 34946; design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:58 2019 Page 1 I D:YwMtazYTmRGkHb8J_pTy?Kyn003-OofOzTNVfgYyRCEmr?NkdLf5NZV5dnxWY6YVt7z2Pd3 -1-4-0 0-11-11 1-4-0 0-11-11 N LOADING (ps2 SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.00 7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.06 Vert(CT) 0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 ' Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matdx-MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 1/Mechanical 2 = 241/0-8-0 (min.0-1-8) 4 = -22/Mechanical Max Horz 2 = 85(LC 12) Max Uplift 3 = -6(LC 13) 2 = -128(LC 12) 4 = -22(LC 1) Max Grav 3 = 17(LC 8) 2 = 241(LC 1) 4 = 24(LC 16) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3, 128 lb uplift at joint 2 and 22 lb uplift at joint 4. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 5 lb FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 CJ1C Corner Jack 10 1 A0261128 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:59 2099 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-V?DmBpO7Q8gp2LpyOjuzAYCG7zg9MEBfnmH2P712Pd2 -1-4-0 0-11-11 1 4-0 0-11-11 3x4 i 0-11-11 0-11-11 , Plate Offsets (X,Y)-- 12:0-1-0,0-1-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) 0.00 7 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.07 Vert(CT) 0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 5 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 1/Mechanical 2 = 241/0-8-0 (min. 0-1-8) 4 = -22/Mechanical Max Horz 2 = 85(LC 12) Max Uplift 3 = -17(LC 12) 2 = -111(LC 12) 4 = -22(LC 1) Max Grav 3 = 17(LC 8) 2 = 241(LC 1) 4 = 18(LC 16) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom, chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 3, 111 lb uplift at joint 2 and 22 lb uplift at joint 4. LOAD CASE(S) Standard Job Truss Truss Type city Ply WTRMAV2 CAD Corner Jack 1 1 A0261129 Job Reference (optional) A-4 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:36:59 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-V?DmBpO7Q8gp2LpyOjuzAYCKzzrxM EBfnmH2PZz2Pd2 0-11-11 0-11-11 N 2x4 = 0-11-11 0-11-11 LOADING (psf) SPACING- 2-0-0 CS'- DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DX 1.25 TC 0.02 Vert(LL) -0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 3 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 53/Mechanical 2 = 32/Mechanical 3 = 21/Mechanical Max Horz 1 = 41(LC 12) Max Uplift 1 = -12(LC 12) 2 = -29(LC 12) 3 = -11.(LC 12) Max Grav 1 = 53(LC 19) 2 = 39(LC 19) 3 = 24(LC 19) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 12 lb uplift at joint 1, 29 lb uplift at joint 2 and 11 lb uplift at joint 3. LOAD CASE(S) Standard Job Truss Truss Type city Ply WTRMAV2 CJ1 W Jack -Open Supported Gable 2 1 ` A0261130 Job Reference (optional) A-1 Root Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:00 20111 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-zBm8O8PIBSoggVNgyQPCimIUWN8A5hRoOQ1 bx0z2Pd1 0-6-8 0-11-11 0-6-8 0-11-11 4.00 F12 2x4 = , --11 0-11-11011 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) 0.00 2 n/r 120 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.21 Vert(CT) 0.00 2 n/r 80 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight: 4 lb - FT = 10% LUMBER - TOP CHORD 2x4 SIP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 158/0-11-8 (min. 0-1-8) 4 = -13/0-11-8 (min. 0-1-8) Max Horz 2 = 53(LC 8) Max Uplift 2 = -155(LC 8) 4 = -13(LC 1) Max Grav 2 = 158(LC 1) 4 = 16(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. ll; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 155 lb uplift at joint 2 and 13 lb uplift at joint 4. 8) Non Standard bearing condition. Review required. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply WTRMAV2 CJ3 Corner Jack 2 1 AO261131 Job Reference (optional) A -+Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:00 2019 Page 1 ID:YWMtaZYrmRGkHb8J_pTy?Kyn003-zBm8O8PIBSoggVN9yQPCimITQN9b5hRoOQ1 bXOz2Pd1 -0-6-8 2-11-11 0-6-8 2-11-11 2x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.16 Vert(LL) -0.01 4-7 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 10 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 106/Mechanical 2 = 209/0-8-0 (min. 0-1-8) 4 = 51/Mechanical Max Horz 2 = 90(LC 8) Max Uplift 3 = -77(LC 12) 2 = -120(LC 8) 4 = -12(LC 12) Max Grav 3 = 106(LC 1) 2 = 209(LC 1) 4 = 55(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf, h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3, 120 lb uplift at joint 2 and 12 lb uplift at joint 4. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply WTRMAV2 CJ3A Corner Jack 3 1 ' A0261132 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:01 201 J Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-RNKWbUQNyIwXlfyLW8xRFzHccmU9g8hyF4m9TSz2Pd0 2-11-11 2-11-11 M af) 2x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.01 4-7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.23 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 100/Mechanical 2 = 298/0-8-0 (min.0-1-8) 4 = 36/Mechanical Max Horz 2 = 169(LC 12) Max Uplift 3 = -95(LC 12) 2 = -119(LC 12) 4 = -4(LC 12) Max Grav 3 = 121(LC 19) 2 = 298(LC 19) 4 = 53(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 95 lb uplift at joint 3, 119 lb uplift at joint 2 and 4 lb uplift at joint 4. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 12 lb FT = 10% Job Truss Truss Type city Ply A0261133 WTRMAV2 CJ3B Corner Jack 8 1 Job Reference (optional) A-4�Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:02 2019 Page 1 ID:YwMtazYTmRGkHbBJ_rTy?Kyn003-vZuvpgQ?j32NvpXX4rSgnBgnMAgWZbx5TjWi0uz2Pd? -1-4-0 2-11-11 1-4-0 2-11-11 3A = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.01 4-7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.22 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.01 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 104/Mechanical 2 = 298/0-8-0 (min.0-1-8) 4 = 32/Mechanical Max Horz 2 = 169(LC 12) Max Uplift 3 = -106(LC 12) 2 = -108(LC 12) 4 = -4(LC 12) Max Grav 3 = 128(LC 19) 2 = 298(LC 1) 4 = 53(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 106 lb uplift at joint 3, 108 lb uplift at joint 2 and 4 lb uplift at joint 4. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 12 lb FT = 10% Job Truss Truss Type city Ply WTRMAV2 CJ3C Corner Jack 1 1 ` A0261134 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com 2x4 = Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:02 2019 Page 1 I D:YwMtazYTmRGkHb8J_pTy?Kyn003-vZuvpgQ?j32NvpXX4rSgnBgo IAr3Zbx5TjWi0uz2Pd? 2-11-11 2-11-11 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.01 3-6 >999 360 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 3-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 We n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 10 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 160/Mechanical 2 = 111/Mechanical 3 = 49/Mechanical Max Horz 1 = 126(LC 12) Max Uplift 1 = -40(LC 12) 2 = -103(LC 12) 3 = -14(LC 12) Max Grav 1 = 162(LC 19) 2 = 133(LC 19) 3 = 57(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 40 lb uplift at joint 1, 103 lb uplift at joint 2 and 14 lb uplift at joint 3. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A0261135 WTRMAV2 CJ3W Jack -Open Structural Gable 2 1 Job Reference (optional) A -$'Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:03 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy7Kyn003-NmSHOARdU NAEXz6jdYzvKON_5aBsl2BFiN FFYKz2Pd_ -0-6-8 , 2-11-11 , � 2-11-11 u4 3x4 ._ LOADING(psf) SPACING- 2-0-0 CSI. TCLL 30.0 Plate Grip DOL 1.25 TC 0.14 TCDL 15.0 Lumber DOL 1.25 BC 0.09 BCLL 0.0 " Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017lrP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings Mechanical except Qt=length) 2=1-0-0, 3=0-3-8. (lb) - Max Horz 2= 110(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 4, 2 except 3=-154(LC 12) Max Grav All reactions 250 lb or less at joint(s) 4, 2, 5 except 3=257(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. ll; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. DEFL. in (loc) I/defl L/d PLATES GRIP Vert(LL) -0.00 12 >999 360 MT20 244/190 Vert(CT) -0.00 5-12 >999 240 Horz(CT) -0.00 4 n/a n/a Weight: 10 lb FT = 10% 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 4, 2 except Qt=lb) 3=154. LOAD CASE(S) Standard Job Truss Truss Type Qty Piy ' A0261136 W7RMAV2 CJ5 Corner Jack 2 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:04 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-ryOfEWSGFg1597hwBGU8tcvl S_PE1VQOxl?p3nz2Pcz -0-6-8 , 4-11-11 0-6-8 4-11-11 3x4 = LOADING (psf) SPACING- 2-0-0 CS'. DEFL. in (loc) I/deft Ud TCLL 30.0 Plate Grip Di 1.25 TC 0.61 Vert(LL) 0.09 4-7 >658 360 TCDL 15.0 Lumber DOL 1.25 BC 0.59 Vert(CT) -0.08 4-7 >701 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a " n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 187/Mechanical 2 = 317/0-8-0 (min. 0-1-8) 4 = 81/Mechanical Max Horz 2 = 139(LC 8) Max Uplift 3 = -139(LC 12) 2 = -163(LC 8) 4 = -13(LC 12) Max Grav 3 = 187(LC 1) 2 = 317(LC 1) 4 = 94(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0A8; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=139, 2=163. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 16 lb FT = 10% Job Truss Truss Type Qty Ply A0261137 WTRMAV2 CJSA Corner Jack 3 1 Job Reference (optional) A=Q`Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:04 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-ryOfEWSGFg1597hwBGUBtcvOV_PP1 VQOx1?p3nz2Pcz 4-11-11 4-11-11 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) -0.07 4-7 >817 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.11 4-7 >532 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 18 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 184/Mechanical 2 = 398/0-8-0 (min.0-1-8) 4 = 71/Mechanical Max Horz 2 = 255(LC 12) Max Uplift 3 = -174(LC 12) 2 = -141(LC 12) 4 = -11(LC 12) Max Grav 3 = 222(LC 19) 2 = 399(LC 19) 4 = 94(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf, h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except at --lb) 3=174, 2=141. LOAD CASE(S) Standard Job Truss Truss Type city Ply W7RMAV2 CJSB Corner Jack 1 i 1 4 A0261138 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:05 201 J Page 1 ID:YwMtazYTmRGkHb8J_pTy?KynO03-J8al RsTuO_QymGG61z?NPpSBaOmEmygX9hkMcDz2Pcy i 4-11-11 4-11-11 U4= LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL) 0.08 3-6 >747 360 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.10 3-6 >562 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Weight: 16 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 270/Mechanical 2 = 191/Mechanical 3 = 79/Mechanical Max Horz 1 = 212(LC 12) Max Uplift 1 = -69(LC 12) 2 = -179(LC 12) 3 = -17(LC 12) Max Grav 1 = 273(LC 19) 2 = 229(LC 19) 3 = 96(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Qt=1b) 2=179. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A0261139 WTRMAV2 CJSW Corner Jack 2 1 Job Reference (optional) A-P Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:06 2019 Page 1 I D:YwMtazYTmRGkHb8J_pTy?Kyn003-nLBPfCU WnIZpOQrIJhWcy1?PGn7pVPwhOLUw8fz2Pcx -0-6-8 , 4-11-11 0-6-8 4-11-11 3x4 = 4-11-11 Plate Offsets (X,Y)-- [2:0-1-10,Edge].__....... _._....... ___..._.._..___._.._._— ......... __._._...._.____. LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) 0.16 4-7 >372 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.45 Vert(CT) 0.14 4-7 >409 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 16 lb FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-1.1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 187/Mechanical 2 = 317/1-0-0 (min. 0-1-8) 4 = 80/Mechanical Max Horz 2 = 139(LC 8)- Max Uplift 3 = -161(LC 8) 2 = -288(LC 8) 4 = -114(LC 8) Max Grav 3 = 187(LC 1) 2 = 317(LC 1) 4 = 94(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. Il; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=161, 2=288, 4=114. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply WTRMAV2 D01 HIP GIRDER 1 1 ' A0261140 Job Reference o tional A-1 Root I russes, Fort Pierce, FL 34946, design(a7altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:07 2099 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-GXhosYU8XbhgOaQVsO2rU EXTiBN?EgLgd?DTg6z2Pcw 1 4-0, 5-0-0 10-6-14 16-0-0 21-5-2 27-0-0 32-0-0 ,33 4-0 ' 1-4-0' 5-0-0 5-6-14 5-5-2 5-5-2 5-6-14 5-0-0 1 4-0' Dead Load Defl. = 318 in 4x12 = 31 1n 32 33 34 1435 36 37 1J 38 39 4012 41 42 43 11 44 5x8 = 5x6 = 1.5x4 11 Sx10 MT20HS= 1.5x4 11 - 5x6 = 5x8 = -0-0 10- 5 6-14 16-0-0 21-5-2 27-0-0 32-0-0 5-0-0 5-6-14 5-5-2 55-2 5-6-14 5-0-0 Plate Offsets (X,Y)-- [2:0-0-0,0-1-11, [6:0-5-O,Edgel, [9:0-0-0,0-1-11, [13:0-5-0,Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) 0.74 13 >519 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.84 Vert(CT) -0.85 13 >452 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr NO WB 0.82 Horz(CT) 0.22 9 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 164 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP 240OF 2.0E WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEDGE Left: 2x6 SP No.2, Right: 2x6 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 1-11-1 cc purlins. BOT CHORD Rigid ceiling directly applied or 3-9-0 oc bracing. WEBS 1 Row at midpt 4-15, 7-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 2949/0-8-0 (min. 0-2-7) 9 = 2950/0-8-0 (min.0-2-7) Max Horz 2 = -200(LC 6) Max Uplift 2 = -1843(LC 5) 9 = -1843(LC 4) Max Grav 2 = 2949(LC 1) 9 = 2950(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4821 /3186, 3-22=-4112/2839, 22-23=-4112/2839, 4-23=-4112/2839, 4-24=-7632/5186, 24-25=-7632/5186, - 25-26=-7632/5186, 5-26=-7632/5186, 5-27=-763215186, 6-27=-7632/5186, 6-28=-7632/5186, 7-28=-7632/5186, 7-29=-4113/2840, 29-30=-4113/2840, 8-30=-4113/2840, 8-9=-4822/3187 BOT CHORD 2-31 =-2771/4153, 15-31 =-2771/4153, Continued on page 2 BOT CHORD 2-31=-2771/4153, 15-31=-2771/4153, 15-32=-4669/6975, 32-33=-4669/6975, 33-34=-4669/6975, 14-34=-4669/6975, 14-35=-4669/6975, 35-36=-4669/6975, 36-37=-4669/6975, 13-37=-4669/6975, 13-38=-4611 /6948, 38-39=-4611 /6948, 39-40=-4611/6948, 12-40=-4611/6948, 12-41=-4611/6948, 41-42=-461116948, 42-43=-4611/6948, 11-43=-4611/6948, 11-44=-2610/4082, 9-44=-2610/4082 WEBS 3-15=-1156/1911, 4-15=-3218/2256, 4-14=-41/400, 4-13=-649/942, 5-13=-717/639, 7-13=-648/940, 7-12=-41/400, 7-11=-3219/2257, 8-11=-1156/1912 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) Concentrated loads from layout are not present in Load Case(s): #101 1 st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load; #801 8th Moving Load; #901 9th Moving Load; #1001 1 Oth Moving Load; #1101 11th Moving Load; #1201 12th Moving Load; #1301 13th Moving Load; #1401 14th Moving Load; #1501 15th Moving Load; #1601 16th Moving Load; #1701 17th Moving Load. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=1843, 9=1843. 9) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 301 lb down and 326 lb up at 5-0-0, 230 lb down and 194 lb up at 7-0-12, 230 lb down and 194 lb up at 9-0-12, 230 lb down and 194 lb up at 11-0-12, 230 lb down and 194 lb up at 13-0-12, 230 lb down and 194 lb up at 15-0-12, 230 lb down and 194 lb up at 16-11-4, 230 lb down and 194 lb up at 18-11-4, 230 lb down and 194 lb up at 20-11-4, 230 lb down and 194 lb up at 22-11-4, and 230 lb down and 194 lb up at 24-11-4 , and 301 lb down and 326 lb up at 27-0-0 on top chord, and 296 lb down and 215 lb up at 5-0-0, 62 lb down and 30 lb up at 7-0-12, 62 lb down and 30 lb up at 9-0-12, 62 lb down and 30 lb up at 11-0-12, 62 lb down and 30 lb up at 13-0-12, 62 lb down and 30 lb up at 15-0-12, 62 lb down and 30 lb up at 16-11-4, 62 lb down and 30 lb up at 18-11-4, 62 lb down and 30 lb up at 20-11-4, 62 lb down and 30 lb up at 22-11-4, and 62 lb down and 30 lb up at 24-11-4, and 296 lb down and 215 lb up at 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90, 3-8=-90, 8-10=-90, 16-19=-20 Concentrated Loads (lb) Job Truss Truss Type Qty Ply A0261140 WTRMAV2 D01 HIP GIRDER 1 1 Job Reference (optional) A-i" Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:07 2019 Page 2 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-GXhosYU8XbhgOaQVsO2rUEXTiBN?EgLgd?DTg6z2Pcw LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-118(B) 6=-100(B) 8=-118(B) 15=-222(B) 11=-222(B)22=-100(B)23=-100(B)24=-100(B) 25=-100(B) 26=-100(B) 27=-100(B) 28=-100(B) 29=-100(B)30=-100(B)32=47(B)34=47(B) 35=47(B)36=47(B)37=47(B) 38=-47(B)39=47(B) 40=-47(B)41=-47(B)43=47(B) Job Truss Truss Type Qty Ply WTRMAV2 D02 HIP 1 1 ' A0261141 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s. May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:08 20% Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-kjFA3uVmlvpXek?hQ6Z41S4h6bn3z89 sfzOCYz2Pcv —0, 7-0-0 16-0-0 25-0-0 32-0-0 ,33-4-0 1-4-0' 7-0-0 9-0-0 9-0-0 7-0-0 1-4-0 7x6 6x8 = 5 7x6 Dead Load Defl. = 3/16 in 5x6 = 3x4 = 5x6 = 3x4 = 5x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) -0.32 9-10 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.60 Vert(CT) -0.52 9-10 >735 240 BCLL 0.0 * Rep Stress Incr YES WB 0.72 Horz(CT) 0.12 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 *Except* T2: 2x6 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-5-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-7-0 oc bracing. WEBS 1 Row at midpt 4-10, 4-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1873/0-8-0 (min.0-2-3) 6 = 1873/0-8-0 (min. 0-2-3) Max Horz 2 = -262(LC 10) Max Uplift 2 = -684(LC 9) 6 = -684(LC 8) Max Grav 2 = 1873(LC 1) 6 = 1873(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2794/2132, 3-4=-2308/2020, 4-5=-2308/2020, 5-6=-2794/2132 BOT CHORD 2-21=-545/861, 2-17=-1526/2280, 10-1 7=-1 526/2280, 10-18=-2503/3484, 9-18=-2503/3484, 9-19=-2503/3484, 8-19=-2503/3484, 8-20=-1537/2280, 6-20=-1537/2280, 6-22=-581/933 WEBS 3-10=-415/762, 4-10=-1453/1068, WEBS 3-10=-415/762, 4-10=-1453/1068, 4-9=0/384, 4-8=-1453/1068, 5-8=-414/761 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=684, 6=684. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES MT20 GRIP 244/190 Weight: 165 Ib FT = 10% Job Truss Truss Type Qty Ply A0261142 WTRMAV2 DO3 HIP 1 1 Job Reference (optional) A-11Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com 46 Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. 'Wed Jun 26 13:37:08 2019 3x8 = 4x6 Dead Load Defl. =1/8 in ._ 12 -- 11 _. 10 " 5x6 — 3x8 = 5x6 = 3x8 = 5x6 = 9-0-0 16-0-0 23-0-0 32-0-0 9-0-0' 7-0-0 7-0-0 9-0-0 Plate Offsets (X,Y)-- [2:0-0-0,0-1-91,[8:0-0-0,0-1-91,[11:0-3-0,0-3-01 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.31 12-15 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -0.45 12-15 >848 240 BCLL 0.0 Rep Stress Incr YES WB 0.33 Horz(CT) 0.13 8 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 169 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-11-5 cc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-12, 5-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1873/0-8-0 (min.0-2-3) 8 = 1873/0-8-0 (min.0-2-3) Max Horz 2 = -327(LC 10) Max Uplift 2 = -687(LC 12) 8 = -687(LC 13) Max Grav 2 = 1873(LC 1) 8 = 1873(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2846/2207, 3-4=-2507/2036, 4-5=-2201/1887, 5-6=-2201/1887, 6-7=-2507/2035, 7-8=-2846/2207 BOT CHORD 2-19=-1645/2339, 12-19=-1645/2339, 12-20=-1754/2637, 11-20=-1754/2637, 11-21=-1754/2637, 10-21=-1754/2637, 10-22=-1661/2339, 8-22=-1661/2339 WEBS 4-12=-533/813, 5-12=-803/595, 5-11=0/325, 5-10=-803/595, WEBS 4-12=-533/813, 5-12=-803/595, 5-11=0/325, 5-10=-803/595, 6-10=-533/813, 3-12=-612/463, 7-10=-612/463 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 ib uplift at joint(s) except Qt=lb) 2=687, 8=687. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply WfRMAV2 DO4 HIP 1 1 ' A0261143 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com A-4-0 6-3-1 11-0 4x6 = Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:09 2019 3x4 = 4x6 = Dead Load Defl. = 3/16 in 2 1 Ri 1 1891 111 0 19 12 20 11 21 10 22 Lj 5x6 = 3x8 = 5x6 WB= 3x8 = 5x6 = 11-0-0 21-0-0 32-0-0 11-0-0 10-0-0 11-0-0 Plate Offsets (X,Y)-- [2:0-0-0,0-1-91, [4:0-3-0,0-1-121, [6:0-3-0,0-1-121, [8:0-0-0,0-1-91 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.64 Vert(LL) -0.49 12-15 >785 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.62 Vert(CT) -0.74 12-15 >519 240 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(CT). 0.09 8 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 168 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 *Except* T2: 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-8-15 oc bracing. WEBS 1 Row at midpt 5-12, 5-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1873/0-8-0 (min.0-2-3) 8 = 1873/0-8-0 (min.0-2-3) Max Harz 2 = -390(LC 10) Max Uplift 2 = -719(LC 12) 8 = -719(LC 13) Max Grav 2 = 1873(LC 1) 8 = 1873(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2872/2144,3-4=-2474/1923, 4-5=-2211/1787,5-6=-2211/1787, 6-7=-2474/1923,7-8=-2872/2144 BOT CHORD 2-19=-1570/2324, 12-19=-1570/2324, 12-20=-1273/2120, 11-20=-1273/2120, 11 -21 =-1 273/2120, 10-21 =-1 273/2120, 10-22=-1581/2347, 8-22=-1581/2347 WEBS 3-12=-805/646, 4-12=-553/858, WEBS 3-12=-805/646, 4-12=-553/858, 5-12=-456/407, 5-10=-456/407, 6-1 0=-552/858, 7-1 0=-805/646 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 2=719, 8=719. 7) This truss has been designed for a moving concentrated load of 200.0lb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A0261144 WTRMAV2 D05 HIP 1 1 Job Reference (optional) A-Y'Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 5x6 = Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:10 2019 Page ID:YwMtazYTmRGkHb8J_pTy?Kyn003-g6NwUZXOgW3Ft284YXbY6t9zzPMiRzaHJzS7HQz2P 13-0-0 19-0-0 26-4-0 32-0-0 $3-4-Q 7 4-0 6-0-0 7-4-0 5-8-0 1-4- 5x6 % 5x6 Z- Dead Load Defl. = 118 in 7.00 12 LV IJ LI — 4a IL — Lo Lu II L! 3x4 = 5x6 = 3x4 = 8-0-7 1&0-0 23-11-9 32-0-0 8-0-7 7-11-9 7-11-9 8-0-7 LOADING (ps2 SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.99 Vert(LL) -0.28 12-13 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.97 Vert(CT) -0.44 12-13 >879 240 BCLL 0.0 * Rep Stress Incr YES WB 0.98 Horz(CT) 0.12 9 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP 240OF 2.0E *Except* T3: 2x4 SP No.2, T1: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-12, 6-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1873/0-8-0 (min. 0-2-3) 9 = 1873/0-8-0 (min.0-2-3) Max Horz 2 = -454(LC 10) Max Uplift 2 = -745(LC 12) 9 = -745(LC 13) Max Grav 2 = 1873(LC 1) 9 = 1873(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3194/2170, 3-4=-3036/2118, 4-5=-2976/2144, 5-6=-2228/1712, 6-7=-2976/2144, 7-8=-3036/2118, 8-9=-3194/2170 BOT CHORD 2-20=-1630/2629, 13-20=-1630/2629, 13-21=-897/1784, 21-22=-897/1784, 22-23=-897/1784, 12-23=-897/1784, 12-24=-898/1745, 24-25=-898/1745, 25-26=-898/1745, 11-26=-898/1745, BOT CHORD 2-20=-1630/2629, 13-20=-1630/2629, 13-21=-897/1784, 21-22=-897/1784, 22-23=-897/1784, 12-23=-897/1784, 12-24=-898/1745, 24-25=-898/1745, 25-26=-898/1746, 11-26=-898/1745, 11-27=-1643/2655, 9-27=-1643/2655 WEBS 3-13=-879/746, 5-13=-590/1005, 5-12=-190/351, 6-12=-190/351, 6-11=-590/1005, 8-11=-879/746 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=745, 9=745. 7) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard 5x6 = PLATES GRIP MT20 2441190 Weight: 173 Ib FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 D06 HIP 1 1 * A0261145 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:11 201 J Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-8lxlivXfbgB6VBjG5E6nf4iDUok?AZiQYdBhptz2Pcs T1 4-0 7-0-1 13-6-8 18-5-8 24-11-15 32-0-0 33-4-4 1-4-0 7-0-1 6-6-7 4-11-0 6-6-7 7-0-1 1-4- 7.00 12 4x6 i 4x6 3x4 = 5x6 = 3x4 = 5x6 = 9-1-2 16-0-0 22-10-14 32-0-0 9-1-2 6-10-14 6-10-14 9-1-2 Plate Offsets (X,Y)--[2:0-0-0,0-1-51,[9:0-0-0,0-1-51,[12:0-3-0,0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 30.0 Plate Grip DOL 1.25 TC 0.69 TCDL 15.0 Lumber DOL 1.25 BC 0.84 BCLL 0.0 Rep Stress Incr YES WB 0.41 BCDL 10.0 Code FBC2017ITP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 *Except' T3: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-9-1 oc bracing. WEBS 1 Row at midpt 5-13, 5-12, 6-12, 6-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 187310-8-0 (min.0-2-3) 9 = 1873/0-8-0 (min.0-2-3) Max Horz 2 = -471(LC 10) Max Uplift 2 = -752(LC 12) 9 = -752(LC 13) Max Grav 2 = 1873(LC 1) 9 = 1873(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3107/2075, 3-4=-3061/2126, 4-5=-3004/2157, 5-6=-2207/1678, 6-7=-3004/2157, 7-8=-3061 /2126, 8-9=-3107/2075 BOT CHORD 2-20=-1502/2512, 13-20=-1502/2512, 13-21=-828/1752, 21-22=-828/1752, 22-23=-828/1752, 12-23=-828/1752, 12-24=-829/1691, 24-25=-829/1691, Dead Load Defl. = 1/8 in n ao 5x6 = DEFL. in (loc) I/deft L/d PLATES GRIP Vert(LL) -0.3211-19 >999 360 MT20 2441190 Vert(CT) -0.4711-19 >810 240 Horz(CT) 0.10 9 n/a n/a Weight: 172 Ib FT = 10% BOT CHORD 2-20=-1502/2512, 13-20=-1502/2512, 13-21=-828/1752, 21-22=-828/1752, 22-23=-828/1752, 12-23=-828/1752, 12-24=-829/1691,24-25=-829/1691, 25-26=-829/1691,11-26=-829/1691, 11 -27=-1 513/2532, 9-27=-1513/2532 WEBS 3-13=-919/781, 5-13=-694/1127, 5-12=-211/325, 6-12=-211/325, 6-11=-693/1127, 8-11=-919f781 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exteri0r(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=752, 9=752. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A A0261146 WTRMAV2 D07 Hip 1 1 Job Reference (optional) A-4 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:12 2019 Page 1 I D:Way_oZ6WZVekVkO8hYvdTozFKAh-cWgvFYHM8Jz6LISfxdOBl ENJC7svugZmHxELJz2Pcr r14-Q 6-10-2 12-4-0 19-8-0 25-1-14 32-0-0 334-Q 1 4-0 6-10-2 5-5-14 7 4-0 5-5-14 6-10-2 1-4-0 7x8 4x6 O Dead Load Defl. =1/8 in 5x6 = 1.5x4 II 3x4 = 46 = 3x8 = 1.5x4 II 5x6 = 25-1-14 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) -0.18 10-12 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.31 10-12 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.93 Horz(CT) 0.10 7 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MS Weight: 175 lb FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-4-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-8-2 oc bracing. WEBS 1 Row at micipt 4-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1873/0-8-0 (min.0-2-3) 7 = 1873/0-8-0 (min.0-2-3) Max Horz 2 = -432(LC 10) Max Uplift 2 = -737(LC 12) 7 = -737(LC 13) Max Grav 2 = 1873(LC 1) 7 = 1873(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3005/2073, 3-4=-2450/1855, 4-5=-2202/1744,5-6=-2451/1855, 6-7=-3005/2073 BOT CHORD 2-24=-500/963, 2-20=-1489/2412, 13-20=-1489/2412, 13-21=-1489/2412, 12-21=-1489/2412, 11-12=-957/1819, 10-1 1=-957/1819,10-22=-1501/2437, 9-22=-1501 /2437, 9-23=-1501 /2437, 7-23=-1501/2437, 7-25=-534/1032 WEBS 3-13=0/302, 3-12=-1002/687, WEBS 3-13=0/302, 3-12=-1002/687, 4-12=-345/724, 5-10=-343/722, 6-10=-1001/687,6-9=0/301 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=737, 7=737. 7) This truss has been designed for a moving concentrated load of 200.0lb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply WTRMAV2 D08 Roof Special 1 1 � A0261147 Job Reference (optional) A-1 Moot I russes, Fort Pierce, FL 34946, design(rNaltruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:13 20119 Page 1 ID: Way_oZ6WZVekVkO8hYvdTozFKAh-4h337bZv7RRgkVteDf8FkVnVYcP_eR?j?xgnulz2Pcq 6-1-5 5-11-11 ' 1-9-0' 4x6 = 4 6x6 = 7x8 // 5x6 = 3x4 = 4x8 = 3x6 = 3x4 = 3x6 II 3x4 = LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T3: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-12, 6-12, 4-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 8 = 38/0-8-0 (min. 0-1-8) 2 = 1582/0-8-0 (min.0-1-14) 9 = 2013/0-8-0 (min.0-2-6) Max Horz 2 = 41O(LC 9) Max Uplift 8 = -219(LC 8) 2 = -642(LC 12) 9 = -869(LC 13) Max Grav 8 = 233(LC 33) 2 = 1582(LC 1) 9 = 2013(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2478/1763, 3-4=-2107/1559, 4-5=-2232/1895, 5-6=-1 871/1544, 6-7=-1363/1129, 7-8=-123/463 BOT CHORD 2-20=-1331/2002, 13-20=-1331/2002, 13-21=-699/1378, 12-21=-699/1378, CSI. DEFL. in (loc) I/deft L/d TC 0.91 Vert(LL) -0.4213-19 >786 360 BC 0.93 Vert(CT) -0.6613-19 >495 240 WB 0.55 Horz(CT) 0.05 9 n/a n/a Matrix -MS BOT CHORD 2-20=-1331/2002, 13-20=-1331/2002, 13-21=-699/1378, 12-21=-699/1378, 11 -1 2=-504/994,11-22=-504/994, 22-23=-504/994, 10-23=-504/994, 10-24=-297/150, 9-24=-297/150, 9-25=-297/150, 8-25=-297/150 WEBS 3-13=-860/714, 4-13=-385/748, 5-12=-1402/1426, 6-12=-559/798, 6-10=-494/426, 7-10=-694/1390, 7-9=-198311421, 4-12=-1075/1088 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This. truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=219, 2=642, 9=869. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Dead Load Defl. = 3116 In PLATES GRIP MT20 244/190 Weight: 180 Ib FT = 10% Job i Truss Truss Type Qty Ply WTRMAV2 DO9 Roof Special 1 1 AO261148 Job Reference (optional) A'r Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:14 2019 Page 1 I D: Way_oZ6WZVekVkO8hYvdTozFKAh-YtdRKxaXulZg MfSmMgU HjKgwOpgNpCsEbQLQCz2Pcp r14-Q 6-1-5 12-1-0 15-1%0 , 23-8-0 27-4-0 32-0-0 1 4- 6-1-5 5-11-11 3-9-0 7-10-0 3-8-0 4-8-0 4x6 = Dead Load Defl. =1/8 in 3x4 = 3x6 = 4x8 — — 3x6 = 4x4 = 3x6 II 3x4 = 5x6 = 8 4-0 15-10-0 23-8-0 27A-0 32-0-0 8�-0 7-6-0 7-10-0 3-8-0 4-8-0 Plate Offsets (X,Y)-- [2:0-0-0,0-1-91, [6:0-2-7,Edgel, [8:0-0-0,0-0-131 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) -0.26 14-20 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.38 12-14 >872 240 BCLL 0.0 Rep Stress Incr YES WB 0.88 Horz(CT) 0.05 9 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 173 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 *Except* T3: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-1-14 oc bracing. WEBS 1 Row at midpt 4-12, 6-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 8 = -85/0-8-0 (min. 0-1-8) 2 = 1561/0-8-0 (min.0-1-13) 9 = 2157/0-8-0 (min. 0-2-9) Max Horz 2 = 410(LC 9) Max Uplift 8 = -280(LC 19) 2 = -637(LC 12) 9 = -900(LC 13) Max Grav 8 = 168(LC 33) 2 = 1561(LC 1) 9 = 2157(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2517/1712, 3-4=-2409/1727, 4-5=_2597/2120,5-6=-2090/1665, 6-7=-1026/913,7-8=-184/728 BOT CHORD 2-21=-1290/2040, 14-21=-1290/2040, 14-22=-675/1357, 22-23=-675/1357, 13-23=-675/1357, 12-13=-675/1357, 12-24=-380/716, 11-24=-380/716, BOT CHORD 2-21=-1290/2040, 14-21=-1290/2040, 14-22=-675/1357, 22-23=-675/1357, 13-23=-675/1357, 12-13=-675/1357, 12-24=-380/716, 11-24=-380/716, 10-11=-380/716, 10-25=-526/252, 9-25=-526/252, 9-26=-526/252, 8-26=-526/252 WEBS 3-14=-799/686, 4-14=-560/953, 4-12=-1160/1248, 5-12=-1731/1625, 6-12=-956/1411, 6-10=-827/628, 7-10=-815/1505, 7-9=-2081/1444 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=280, 2=637, 9=900. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A0261149 V1fTRMAV2 D10 Roof Special 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 a May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:14 2019 Page 1 ID: Way_oZ6WZVekVkO8hYvdTozFKAh-YtdRKxaXulZgMfSmMgU HjKgCOovNpksEbQLQCz2Pcp r1 4-q 6-1-5 6 f{-1 12-1-0 17-10-0 25-8-0 ,27 4-q 32-0-0 1�4 00 6-1-5 0-"1T-12 5-8-15 5-9-0 7-10-0 1-8-0 4-8-0 5x6 = 5x6 = 3x4 = 3x6 = 4x10 = 6x6 = 4x6 = LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017[TP12014 LUMBER - TOP CHORD 2x4 SP No.2 *Except* T2,T3: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 4-10, 6-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 8 = -374/0-8-0 (min. 0-1-8) 2 = 1512/0-8-0 (min.0-1-13) 9 = 2496/0-8-0 (min.0-2-15) Max Horz 2 = 41O(LC 9) Max Uplift 8 = -542(LC 19) 2 = -626(LC 12) 9 = -1026(LC 13) Max Grav 8 = 126(LC 12) 2 = 1526(LC 19) 9 = 2496(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2507/1598, 3-4=-2860/2022, 4-5=-2817/2250, 5-6=-2192/1697, 6-7=-293/1172, 7-8=-542/1188 BOT CHORD 2-19=-1186/2073, 12-19=-1186/2073, 12-20=-625/1292, 20-21=-625/1292, 21-22=-625/1292, 11-22=-625/1292, CSI. DEFL. in (loc) I/deft Ud TC 0.91 Vert(LL) -0.6310-12 >520 360 BC 0.76 Vert(CT) -1.0610-12 >310 240 WB 0.84 Horz(CT) 0.03 9 n/a n/a Matrix -MS BOT CHORD 2-19=-1186/2073, 12-19=-1186/2073, 12-20=-625/1292, 20-21=-625/1292, 21-22=-625/1292, 11-22=-625/1292, 10-11=-625/1292, 10-23=-273/75, 9-23=-273/75, 9-24=-1036/571, 8-24=-1036/571 WEBS 4-12=-893/1411, 4-1 0=-1 216/1377, 5-1 0=-1 964/1780, 6-1 0=-1 512/2413, 6-9=-2165/1408, 3-12=-883f784, 7-9=-562/452 NOTES- 1)Unbalanced roof live loads have been considered for this design. . 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=542, 2=626, 9=1026. 8) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Dead Load Defl. = 7/16 in N 4 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 165 lb FT = 10% Job Truss Truss Type Qty Ply A0261150 WTRMAV2 D11 ROOF SPECIAL 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com s�A 4-10-4 Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:15 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-14ApXHb9f3hXzp11 K4Bjpwsg7Q8f6FIOTF9uyez2Pcc 19-2-0 27-0-0 1 32-0-0 33-4-0 5x6 = Dead Load Defl. =1/4 in — 13 12 -- 10 9 " 5x6 = 1.5x4 11 4x12 = 5x10 MT20HS= 1.5x4 11 LOADING (psf SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.96 Vert(LL) - 0.33 10 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.73 . Vert(CT) -0.52 9-10 >736 240 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.15 7 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP 2400F 2.0E *Except* T1: 2x4 SP M 30, T4: 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-1-13 oc bracing. WEBS 1 Row at midpt 3-12, 4-12, 5-12, 5-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1873/0-8-0 (min.0-2-3) 7 = 1873/0-8-0 (min.0-2-3) Max Horz 2 = -423(LC 10) Max Uplift 2 = -734(LC 12) 7 = -840(LC 13) Max Grav 2 = 1873(LC 1) 7 = 1873(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3318/2135, 3-4=-2626/1811, 4-5=-2611/1806, 5-6=-2630/1 99 1, 6-7=-2919/2139 BOT CHORD 2-20=-1626/2745, 13-20=-1626/2745, 13-21=-1626/2745, 12-21=-1626/2745, 12-22=-3070/4514, 11-22=-3070/4514, 10-11=-3070/4514, 10-23=-3066/4520, 9-23=-3066/4520, 9-24=-1611/2390, 7-24=-1611 /2390 BOT CHORD 2-20=-1626/2745, 13-20=-1626/2745, 13-21=-1626/2745, 12-21=-1626/2745, 12-22=-3070/4514, 11-22=-3070/4514, 10-11=-3070/4514, 10-23=-3066/4520, 9-23=-3066/4520, 9-24=-1611/2390, 7-24=-1 611/2390 WEBS 3-13=0/271, 3-12=-1007/716, 4-12=-1 163/1762, 5-12=-2917/2287, 5-10=0/345, 5-9=-2286/1565, 6-9=-501/989 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasa=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=734, 7=840. 8) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard 4x4 = 5x6 = PLATES GRIP MT20 2441190 MT20HS 187/143 Weight: 164 Ib FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 D12 ROOF SPECIAL GIRDER 1 1 `A0261151 Job Reference (optional) A-1 KooT i russes, hOrr Pierce, I-L s4546, design(caltruss.com A-4-0 ' 5-1-10 4x6 = 1.5x4 II Kun: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:16 2019 6-11-6 4x6 = 5x10 = 5x10 MT20HS= 5x8 = 3x4 = 1.5x4 II 4x8 = 5x6 = Dead Load Deft. = 3/8 in 5-1-10 12-1-0 19-0-6 21-2-0 25-1-0 29-0-0 32-0-0 5-1-10 6-11-6 6-11-6 2-1-10 3-1,1-0 3-11-0 3-0-0 Plate Offsets (X,Y)— I2:0-0-0,0-0-131, f9:0-0-0,0-1-51, r11:0-3-8,0-2-01, (14:0-3-8,0-2-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.90 Vert(LL) 0.55 13-14 >702 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.83 13-14 >463 240 MT20HS 187/143 BCLL 0.0 * Rep Stress Incr . NO WB 0.99. Horz(CT) 0.16 9 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 171 lb FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 *Except* T4: 2x4 SP No.2 BOT CHORD 2x4 SP 240OF 2.0E WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-3-14 oc bracing. WEBS 1 Row at midpt 7-11 2 Rows at 1/3 pts 5-16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 2037/0-8-0 (min.0-1-11) 9 = 2409/0-8-0. (min.0-2-0) Max Horz 2 = -423(LC 6) Max Uplift 2 = -862(LC 8) 9 = -1286(LC 9) Max Grav 2 = 2037(LC 1) 9 = 2409(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3185/1301, 3-4=-2625/1217, 4-5=-2629/1166,5-6=-5987/2830, 6-7=-7887/3825, 7-24=-3199/1782, 8-24=-3199/1782, 8-9=-3698/1971 BOT CHORD 2-25=-1182/2731, 17-25=-1182/2731, 17-26=-1182/2731, 16-26=-1182/2731, 16-27=-2310/5231, 15-27=-2310/5231, 14-15=-2310/5231, 14-28=-3661 /7923, 13-28=-3661 /7923, 13-29=-3258/6627, BOT CHORD 2-25=-1182/2731,17-25=-1182/2731, 17-26=-118212731, 16-26=-1182/2731, 16-27=-2310/5231, 15-27=-2310/5231, 14-15=-2310/5231, 14-28=-3661/7923, 13-28=-3661 /7923, 13-29=-3258/6627, 29-30=-3258/6627, 12-30=-3258/6627, 12-31=-3258/6627, 11-31=-3258/6627, 11-32=-1554/3082, 9-32=-1554/3082 WEBS 3-17=0/264, 3-16=-779/552, 4-16=-850/1875, 5-16=-3420/1922, 5-14=-1190/2596, 6-14=-3699/1857, 6-13=-769/534, 7-13=-845/1528, 7-12=-296/706, 7-11=-3884/1870, 8-11=-744/1624 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=862, 9=1286. 8) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)164 lb down and 104 lb up at 24-11-4, and 164 lb down and 104 lb up at 26-11-4, and 237 lb down and 251 lb up at 29-0-0 on top chord, and 623 lb down and 340 lb up at 24-2-12, 35 lb down and 17 lb up at 24-114, and 35 lb down and 17 lb up at 26-11-4, and 48 lb down and 35 lb up at 28-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-90, 4-6=-90, 6-8=-90, 8-10=-90, 18-21=-20 Concentrated Loads (lb) Vert: 8=-19(F) 12=-12(F) 11=-2(F) 7=-15(F) 24=-1 5(F) 30=-623(F) 31=-12(F) Job Truss Truss Type Qty Ply WTRMAV2 D13 HIP 1 1 A0261152 Job Reference (optional) A -; 'Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:17 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-zSlZyzcQBgxFD6BQSVDBuLyCSDrRaEglwZe?1 Wz2Pcm 4-11-7 ' 2-2-0 ' 4-1 4x6 = 5x8 -Z� Dead Load Defl. =1/4 in 10 " ,8 " 5x6 = 5x6 WB= 4x6 = 24-2-0 -11 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) -0.41 8-13 >715 360 TCDL 15.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.68 8-13 >426 240 BCLL 0.0 Rep Stress Incr YES WB 0.64 Horz(CT) 0.04 7 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-10-3 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 7 = 1326/Mechanical 2 = 1446/0-8-0 (min. 0-1-11) Max Horz 2 = 377(LC 11) Max Uplift 7 = -528(LC 13) 2 = -592(LC 12) Max Grav 7 = 1326(LC 1) 2 = 1446(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2293/1519, 3-4=-1861/1263, 4-5=-1681/1216,5-6=-1857/1266, 6-7=-2288/1527 BOT CHORD 2-17=-1119/1811, 10-17=-1119/1811, 9-1 0=-571/1224, 8-9=-571/1224, 8-18=-1130/1805, 7-18=-1130/1805 WEBS 3-10=-831/680, 4-10=-327/613, 5-8=-347/616, 6-8=-829/692 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and. right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a - rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 7=528, 2=592. 8) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 129 Ib FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 D14 HIP 1 1 A0261153 Job Reference' o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com -14-0. 4-11 5x6 = Kun: 8.210 s May 16 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:18 2011) Page 1 4x6 5x8 Iu tl 3x8 = 3x4 = 3x4 = Dead Load Defl. =1/8 in 4x6 = 0 Plate Offsets (X,Y)-- [2:0-0-0,0-1-91, [5:0-4-0,0-1-111,[7:0-0-0,0-0-131 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.88 Vert(LL) -0.31 8-13 >936 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.77 Vert(CT) -0.47 8-13 >617 240 BCLL 0.0 Rep Stress Incr YES WB 0.34 Horz(CT) 0.06 7 n/a n/a BCDL 10.0 Code FBC2017lfP12014 Matrix -MS Weight: 122 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-3-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 7 = 1326/0-8-0 (min.0-1-9) 2 = 1446/0-8-0 (min. 0-1-11) Max Horz 2 = 314(LC 11) Max Uplift 7 = -504(LC 13) 2 = -568(LC 12) Max Grav 7 = 1326(LC 1) 2 = 1446(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2186/1578, 3-4=-1848/1394, 4-5=-1668/1323, 5-6=-1844/1401, 6-7=-2179/1590 BOT CHORD 2-17=-1192/1741, 10-17=-1192/1741, 10-18=-799/1401, 9-18=-799/1401, 8-9=-799/1401,8-19=-1207/1733, 7-19=-1207/1733 WEBS 3-10=-643/492, 4-10=-206/514, 5-8=-218/512,6-8=-636/506 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl.;, GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing. plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 7=504, 2=568. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply AO261154 WTRMAV2 D15 HIP 1 1 Job Reference (optional) A -'Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:19 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-vrQKNeegjHBzSQKoZwFf m1awlTH2BkbNt765Pz2Pck -1-4-0 , 7-0-0 12-1-0 17-2-0 _ 24-2-0 25-6-0 1 4-0 7-0-0 5-1-0 5-1-0 7-0-0 ' 1-4-0 ' Lu 5x6 = 7-0-0 5x6 3x4 = 3x4 = 5x6 zzr Dead Load Defl. = 3/16 In 4x4 = 3x4 = 5x6 = 17-2-0 24-2-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. __ in (loc) Well L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) -0.47 8-10 >616 360 TCDL 15.0 Lumber DOL 1.25 BC 0.87 Vert(CT). -0.69 8-10 >420 240 BCLL 0.0 * Rep Stress Incr YES WB 0.41 Horz(CT) 0.06 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 *Except* T2: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-11-10 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1443/0-8-0 (min. 0-1-11) 6 = 1443/0-8-0 (min.0-1-11) Max Horz 2 = -263(LC 10) Max Uplift 2 = -537(LC 12) 6 = -537(LC 13) Max Grav 2 = 1443(LC 1) 6 = 1443(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1976/1450, 3-4=-1714/1425, 4-5=-1714/1425, 5-6=-1976/1450 BOT CHORD 2-20=-340/655, 2-17=-936/1571, 10-17=-936/1571, 10-18=-1231/1857, 9-18=-1231/1857, 8-9=-1231/1857, 8-19=-945/1571, 6-19=-945/1571, 6-21=-374/724 WEBS 3-10=-196/489, 4-10=-490/426, 4-8=-490/426, 5-8=-196/489 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=537, 6=537. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 112 Ib FT = 10% Job Truss Truss Type city Ply A0261155 WTRMAV2 D16 HIP GIRDER 1 1 ' Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:20 2019. Page 1 I D:YwMtazYTmRGkHb8J_pTy?Kyn003-N 1_ib_el UbJg4av?7dmu W_agtRolnbticXtfdrz2Pcj -14-0 , 5-0-0 12-1-0 19-2-0 24-2-0 , 25-6-0 1-4-0 ' 5-0-0 7-1-0 7-1-0 5-0-0 1-4-0 Dead Load Defl. = 3/16 in AYA 5x6 = 4x4 = 1.5x4 11 5x10 MT20HS= 4x4 = 5x6 = 5-0-0 , 12-1-0 19-2-0 24-2-0 5-0-0 7-1-0 7-1-0 5-0-0 Plate Offsets (X,Y)-- [2:0-0-0,0-1-1),[6:0-0-0,0-1-1) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.96 Vert(LL) 0.36 8-10 >800 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -0.44 8-10 >665 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr NO WB 0.61 Horz(CT) 0.14 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 115 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-0-13 oc bracing. WEBS 1 Row at midpt 4-11, 4-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 2224/0-8-0 (min.0-2-10) 6 = 2224/0-8-0 (min.0-2-10) Max Horz 2 = -200(LC 38) Max Uplift 2 = -1389(LC 8) 6 = -1389(LC 9) Max Grav 2 = 2248(LC 46) 6 = 2248(LC 47) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3528/2292, 3-18=-3017/2055, 18-19=-3017/2055, 19-20=-3017/2055, 4-20=-3017/2055, 4-21=-3017/2055, 21-22=-3017/2055, 22-23=-3017/2055, 5-23=-3017/2055, 5-6=-3528/2292 BOT CHORD 2-24=-2011/3050, 11-24=-2011/3050, 11-25=-3135/4732, 25-26=-3135/4732, 26-27=-3135/4732, 27-28=-3135/4732, 10-28=-3135/4732, 10-29=-3135/4732, 29-30=-3135/4732, 30-31=-3135/4732, 9-31=-3135/4732, 9-32=-3135/4732, BOT CHORD 2-24=-2011/3050, 11-24=-2011/3050, 11-25=-3135/4732, 25-26=-313514732, 26-27=-3135/4732, 27-28=-313.5/4732, 10-28=-3135/4732, 10-29=-3135/4732, 29-30=-3135/4732, 30-31=-3135/4732, 9-31=-3135/4732,9-32=-3135/4732, 8-32=-3135/4732, 8-33=-1874/2990, 6-33=-1874/2990 WEBS 3-11=-624/1159, 4-11 =-1 858/1356, 4-10=-29/517, 4-8=-1857/1355, 5-8=-624/1159 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) Concentrated loads from layout are not present in Load Case(s): 4101 1st Moving Load; 4201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; 4601 6th Moving Load; #701 7th Moving Load; 4801 8th Moving Load; #901 9th Moving Load; #1001 10th Moving Load; #1101 11th Moving Load; #1201 12th Moving Load; #1301 13th Moving Load. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=1389, 6=1389. 9) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 301 lb down and 326 lb up at 5-0-0, 230 lb down and 194 lb up at 7-0-12, 230 lb down and 194 lb up at 9-0-12, 230 lb down and 194 lb up at 11-0-12, 230 lb down and 194 lb up at 13-1-4, 230 lb down and 194 lb up at 15-1-4, and, 230 lb down and 194 lb up at 17-1-4, and 301 lb down and 326 lb up at 19-2-0 on top chord, and 296 lb down and 215 lb up at' 5-0-0, 62 lb down and 30 lb up at 7-0-12, 62 lb down and 30 lb up at 9-0-12, 62 lb down and 30 lb up at 11-0-12, 62 lb down and 30 lb up at 13-1-4, 62 lb down and 30 lb up at 15-1-4, and 62 lb down and 30 lb up at 17-1-4, and 296 lb down and 215 lb up at 19-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pig Vert: 1-3=-90, 3-5=-90, 5-7=-90, 12-15=-20 Concentrated Loads (lb) Vert: 3=-118(F) 5=-118(F) 11=-222(F) 8=-222(F) 18=-100(F) 19=-100(F) 20=-100(F)21=-100(F) 22=-100(F) 23=-100(F) 25=-47(F) 27=-47(F) 28=-47(F) 29=-47(F) 30=-47(F)32=-47(F) Job Truss Truss Type Qty Ply WTRMAV2 F01 FLOOR 8 1 A0261156 Job Reference (optional) „--i moor i russes, Forr Pierce, FL a4a4u, oesign(daltruss.cwm Kun: 8.21U s May 18 2U18 vrint: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:20 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-NI_ib_elUbJg4av?7dmuW ajoRponaHlcXtfdrz2Pcj 6-1-8 7-4-8 , 8-7-8 , 14-9-0 15-042 3x4 = 1 5x6 = 2 1-3-0 3 5x6 = Dead Load Defl. =1/8 in 3x10 11 4 5 10 9 8 7 6 46 = 1.5x4 11 1.5x4 11 5x6 = 6-1-8 7 4-8 8-7-8 14 6-1-8 1-3-0 1-3-0 6- LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d TCLL 40.0 Plate Grip DOL 1.00 TC 0.78 Vert(LL) -0.15 7-8 >999 360 TCDL 15.0 Lumber DOL 1.00 BC 0.86 Vert(CT) -0.25 7-8 >704 240 BCLL . 0.0 Rep Stress Incr YES WB 0.65 Horz(CT) 0.03 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x6 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-9-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-10, 3-7 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 961/Mechanical 5 = 963/0-3-0 (min. 0-1-8) Max Grav 10 = 961(LC 1) 5 = 963(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-345/0, 2-3=-2209/0 BOT CHORD 9-10=0/2209, 8-9=0/2209, 7-8=0/2209 WEBS 4-7=0/684, 2-10=-2167/0, 3-7=-2293/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 2 PLATES GRIP MT20 244/190 Weight: 82 lb FT = 10% Job Truss Truss Type Qty Ply A0261157 WTRMAV2 F02 FLOOR 8 1 Job Reference (optional)' A-1 Root I russes, Fort coerce, I-L 34945, designga1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:21 2015 Page 1 I D:YwMtazYTmRGkHb8J_pTy?Kyn003-rDY4oKfwEvRhhkUBhK173B6wPgCCW2nurBcCAlz2Pci 6-44 7-7 4 8-10-4 , 15-2-8 6-4-4 1-3-0 1-3-0 6-44 13x6 = 6 4x6 = 9 5x6 = 1.5x4 II 8-10.4 3 5x6 = 1.5x4 11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.66 Vert(LL) -0.15 7-8 >999 360 TCDL 15.0 Lumber DOL 1.00 BC 0.65 Vert(CT) -0.26 7-8 >690 240 BCLL 0.0 Rep Stress Incr NO WB 0.63 Horz(CT) 0.04 5 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 `Except' W1: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-5-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-8, 3-5 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 8 = 1057/Mechanical 5 = 982/Mechanical Max Grav 8 = 1057(LC 1) 5 = 982(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-348/0, 2-3=-2235/0, 4-5=-339/0 BOT CHORD 8-9=0/2235, 9-10=0/2235, 7-10=0/2235, 6-7=0/2235, 5-6=0/2235 WEBS 2-8=-2141/0, 3-5=-2171/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Load case(s) 1, 2, 3, 4, 5, 6 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-4=-110, 5-8=-20 Concentrated Loads (lb) Vert: 9=-50 10=-50 2) Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-4=-110, 5-8=-20 Concentrated Loads (lb) Vert: 9=-50 10=-50 3) 1st chase Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-3=-110, 3-4=-30, 5-8=-20 Concentrated Loads (lb) Vert: 9=-50 10=-50 4) 2nd chase Dead + Floor Live (unbalanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-2=-30, 2-4=-110, 5-8=-20 Concentrated Loads (lb) Vert: 9=-50 10=-50 5) 3rd chase Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-3=-110, 3-4=-30, 5-8=-20 Concentrated Loads (lb) Vert: 9=-50 10=-50 6) 4th chase Dead: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-2=-30, 2-4=-110, 5-8=-20 Concentrated Loads (lb) Vert: 9=-50 10=-50 Dead Load Deb. =1/16 in Us = 46 PLATES GRIP MT20 244/190 Weight: 71 lb FT = 10% Job Truss Truss Type Qty Ply A0261158 WTRMAV2 F03 Roof Special 4 1 Job Reference (optional) A-IFRoof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:22 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-JQ5SOggY?CaYJu3NF2pMbPf59EWJFX_24rMmikz2Pch 15-4-4 0 12 6-3-2 7-6-0 8 9-0 14-8-8 1 -2-1 26-0-4 2 -0 0- - 2 5-11-6 1-2-14 1-3-0 5 11-8 -6 10-84 0-3-12 0-1-8 Dead Load Defl. =1/16 in 4x10 II 12 3x6 11 46 = 46 = 6x8 = 3x4 II 46 = 3 4 5 6 7 8 9 4x6 = 3x8 11 10 11 12 2221 20 19 18 17 16 15 1413 4x6 = 1.5x4 11 1.5x4 11 4x4 = 4x4 = 1.5x4 11 1.5x4 11 4x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d TCLL 40.0 Plate Grip DOL 1.00 TC 0.66 Vert(LL) -0.11 19-20 >999 360 TCDL 15.0 Lumber DOL 1.00 BC 0.73 Vert(CT) -0.18 20 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.51 Horz(CT) -0.01 12 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x8 SP 240OF 1.8E 'Except' 3) Recommend 2x6 strongbacks, on edge, spaced at BOT CHORD 2x4 SP No.2 10-0-0 oc and fastened to each truss with 3-1 Od 132: 2x4 SP No.3 WEBS 2x4 SP No.3 'Except' (0.131" X 3") nails. Strongbacks to be attached to W1: 2x4 SP No.2 walls at their outer ends or restrained by other means. BRACING - TOP CHORD LOAD CASE(S) Structural wood sheathing directly applied or 6-0-0 oc Standard purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-21, 4-18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 898/0-3-0 (min.0-1-8) 12 = 632/0-3-0 (min.0-1-8) 7 = 1844/0-4-12 (min.0-1-8) Max Grav 1 = 912(LC 3) 12 = 674(LC 4) 7 = 1844(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-1847/0, 9-10=-976/0, 2-21=0/541, 11-14=0/428 BOT CHORD 20-21=0/1847, 19-20=0/1847, 18-19=0/1847, 6-18=0/546, 8-17=0/427, 16-17=0/976, 15-16=0/976, 14-15=0/976 WEBS 3-21=-1714/0, 4-18=-1831/0, 9-1 7=-1 023/0, 10-14=-964/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) The Fabrication Tolerance at joint 5 = 10% 26-0-4 PLATES GRIP MT20 244/190 Weight: 159 lb FT = 10% Job Truss Truss Type Qty Ply w A0261159 UVTRMAV2 F04 FLOOR 10 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:23 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy7Kyn003-ocfrDOhAmW iPxl eZolKb8cCHre_I_38BIV5JEAz2Pcg -5-5-8 ,0-5-$ 4-1-4 5-4 4 6-7 4 10-8-8 5-0-0 b-5- 4-1-4 1-3-0 1-NO 4-1-4 3x6 11 6x8 = 4x6 = 3x6 11 12 11 10 9 4x4 = 1.5x4 II 1.5x4 II LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.60 Vert(LL) 0.03 11 >999 360 TCDL 15.0 Lumber DOL 1.00 BC 0.20 Vert(CT) 0.04 11 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.19 Horz(CT) 0.00 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x8 SP 240OF 1.8E BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x8 SP 240OF 1.8E LBR SCAB 1-4 2x8 SP 240OF 1.8E one side BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 9 = 187/Mechanical 2 = 998/0-4-12 (min.0-1-8) Max Uplift 9 = -29(LC 3) Max Grav 9 = 296(LC 4) 2 = 998(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-351/362 BOT CHORD 11-12=-362/351,10-11=-362/351, 9-10=-362/351 WEBS 6-12=-382/292, 7-9=-353/403 NOTES- 1) Attached 8-0-0 scab 1 to 4, front face(s) 2x8 SP 240OF 1.8E with 2 row(s) of 10d (0.131 "x3") nails spaced 9" o.c.except : starting at 4-2-6 from end at joint 1, nail 2 row(s) at 3" o.c. for 3-9-10. 2) Unbalanced floor live loads have been considered for this design. 3) The Fabrication Tolerance at joint 5 = 10% 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-3=-55, 3-8=-55, 9-12=-10 Concentrated Loads (lb) Vert: 1=-200 4x4 = 10-8-8 4-1-4 PLATES GRIP MT20 244/190 Weight: 108 Ib FT = 10% Job Truss Truss Type Qty Ply A0261160 WTRMAV2 F05 FLOOR 2 1 Job Reference (optional) A-4'Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:23 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-ocfrDOhAmWiPxl eZolKbBcClleyC_?vBIV5JEAz2Pcg 0-2-6 0.0.12 -3- 4-3-10 5-5-7 6-9-10 10-10-14 -3- 4-1-4 1-1-13 1-4-3 4-1-4 0-0-12 g I I 46 = 3x8 11 0-1-III' 1 2 3 4 46 = 5 T1 W1 W2 W2 ,1. W1 W1 W1 Ll 131 Li 9 4x6 = 7 0 1.5x4 -2-6 0-0-12 4x6 = ,0-3-2i 1 4-3-10 i 5-5-7 i 6-9-10 i 10-10-14 0-3- 4-1-4 1-1-13 1-4-3 4-1-4 0.0.12 1 5x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.57 Vert(LL) -0.04 7-8 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.00 BC 0.36 Vert(CT) -0.06 7-8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.40 Horz(CT) 0.01 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 68 lb FT = 10% LUMBER - TOP CHORD 2x8 SP 2400F 1.8E BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 696/0-4-12 (min. 0-1-8) 6 = 703/Mechanical Max Grav 1 = 696(LC 1) 6 = 703(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-1090/0, 5-6=-254/0, 2-9=0/462 BOT CHORD 8-9=0/1090, 7-8=0/1090, 6-7=0/1090 WEBS 3-9=-1 097/0, 4-6=-1 127/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job Truss Truss Type city Ply al A0261161 WTRMAV2 F06 FLOOR 2 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:24 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-GoDDQMhpXggGYBDmMTrggqkU92MejYN KX9rtmcz2Pc1 3-10-8 3-10-8 1.5x4 11 1 3x4 = 2 4 3 1.5x4 11 3x4 = 3-10-8 LOADING (psf) TCLL 40.0 TCDL 15.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL : 1.00 Lumber DOL 1.00 Rep Stress Incr YES Code FBC20171TPI2014 CSI. TC 0.50 BC 0.09 WB 0.00 Matrix -MP DEFL. in (loc) I/deft Ud Vert(LL) 0.00 4 "'* 360 Vert(CT) -0.01 3-4 >999 240 Horz(CT) 0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 21 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-10-8 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 233/Mechanical 3 = 233/Mechanical Max Grav 4 = 233(LC 1) 3 = 233(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply WTRMAV2 FG01 FLOOR 1 3 A0261162 Job Reference (optional) A-T Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:25 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-k?nbeiiR17y7ALoywAM3D1 HZMSagSmBUmpaQJ3z2Pce P 4 $ 3-4-2 5-5-13 6-4-7 6-10-1a 9-4-14 10-4-7 10-9-15 13-2-3 16-3-12 0 4-8 2-11-9 2-1-12 0-10-10 0-6-7 2-6-0 0-11-9 -5- 2 4-5 3-1-9 Dead Load Defl. = 1/8 in 2x4 II 4x12 = 3x8 = 1.5x4 II 1.5x4 II 5x12 = 2x4 II 1 2 W q W1 81 B2 s 6 13 14 15 11 16 10 12x14 = 9 17 c G 6 6' 7x10 MT20HS= LOADING (psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 15.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017[TP12014 LUMBER - TOP CHORD 2x4 SP M 30 *Except* T2: 2x4 SP 240OF 2.0E BOT CHORD 2x8 SP 240OF 1.8E WEBS 2x6 SP No.2 *Except* W4: 2x4 SP M 30, W2: 2x4 SP No.2 W3: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-9-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12 = 16791/0-7-10 (min.0-4-10) 8 = 7905/0-8-0 (min. 0-2-3) Max Grav 12 = 16791(LC 1) 8 = 7905(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1393/0, 2-3=-20949/0, 3-4=-20949/0, 4-5=-20949/0, 5-6=-20949/0, 6-7=-965/0, 7-8=-253/0 BOT CHORD 12-13=0/11685, 13-14=0/11685, 14-15=0/11685, 11-15=0/11685, 11-16=0/20949, 10-16=0/20949, 9-10=0/11287, 9-17=0/11287, 8-17=0/11287 WEBS 6-10=0/11111, 6-8=-11717/0, 2-11 =0/1 0507, 2-12=-11507/0, 5-10=-464/0 NOTES- 1) 3-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 -1 row at 0-7-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 -1 row at 0-9-0 oc. 12x14 = 7x10 MT20HS= CSI. DEFL. in (loc) I/deft ' Ud TC 0.85 Vert(LL) -0.20 11 >952 360 BC 0.62 Vert(CT) -0.32 11 >597 240 WB 0.99 Horz(CT) 0.04 8 n/a - n/a Matrix -MS 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 3 = 10%, joint 9 = 10% . 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 953 lb down at 0-11-0, 945 lb down at 0-11-0, 950 lb down at 2-4-8, 941 lb down at 2-4-8, 950 lb down at 4-4-8, 941 lb down at 4-4-8, 950 lb down at 6-4-8, 941 lb down at 6-4-8, 950 lb down at 8-4-8, 941 lb down at 8-4-8, 950 lb down at 104-8, 941 lb down at 10-4-8, 950 lb down at 12-4-8, 941 lb down at 124-8, and 950 lb down at 14-4-8, and 941 lb down at 14-4-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-7=-110, 8-12=-20 Concentrated Loads (lb) Vert: 12=-7500 9=-1 891 (F=-950, B=-941) 1 0=-1 891 (F=-950, B=-941) 11 =-1 891 (F=-950, B=-941) 13=-1897(F=-953, B=-945) 14=-1 891 (F=-950, B=-941) 15=-1 891 (F=-950, B=-941)16=-1891(F=-950,E=-941) 17=-1891(F=-950, B=-941) 5x8 = PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 302 lb FT = 10% Job Truss Truss Type Qty Ply A0261163 WTRMAV2 FG02 FLOOR 1 2� Job Reference(optional) H-1 KOOT i russes, ron coerce, rL 34U413, cesignLaitruss.com 1 8x14 = 2 4x8 = Kun: a.ziu s may is zuits i-nnu n.ziu s ID:YwMtazYTmRGkHb� 2x4 11 3 2x4 11 4 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:25 201*9 Page 1 ry?Kyn003-k?nbelIR17y7ALoywAM3D1 HcASXxSgzUmpaQJ3z2Pce Dead Load Dell. = 1/8 in 5x14 = 3x4 11 5 6 5x10 MT20HS= 10x14 = 46 = Us 11 5x6 = 3-9-1 6-3-6 7-6-6 , 8-9-6 11-2-11 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.67 Vert(LL) -0.17 10-11 >999 360 TCDL 15.0 Lumber DOL 1.00 BC 0.79 Vert(CT) -0.27 10-11 >661 240 BCLL 0.0 Rep Stress Incr NO WB 0.75 Horz(CT) 0.03 7 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x6 SP 240OF 2.0E BOT CHORD 2x8 SP 240OF 1.8E WEBS 2x4 SP No.3 `Except' W1: 2x6 SP No.2 W2: 2x4 SP 240OF 2.0E W6: 2x4 SP M 30 W3: 2x8 SP 240OF 1.8E BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12 = 7509/0-4-0 (min. 0-3-2) 7 = 303710-8-0 (min.0-1-8) Max Grav 12 = 7509(LC 1) 7 = 3037(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-12=-6505/0, 1-2=-15059/0, 2-3=-12086/0,3-4=-12086/0, 4-5=-12086/0, 5-6=-385/0, 6-7=-310/0 BOT CHORD 11-12=0/1140, 10-11=0/15059, 9-10=0/12086, 8-9=0/5318, 7-8=0/5318 WEBS 1 -11 =0/1 5079, 2-10=-3785/0, 5-9=0/7647, 5-8=-868/0, 5-7=-5495/0, 4-9=-1293/0, 3-10=0/460, 2-11=0/2210 NOTES- 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 -1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3).Unbalanced floor live loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-6=-110, 7-12=-20 Concentrated Loads (lb) Vert: 11=-8648 15-0-12 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 218 Ib FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 FG03 FLOOR 1 3 A0261164 Job Reference (optional) n-�- Rwi i iusbes, ruiL rieice, rL 04a1+o, UU%HynLa iuuss.com Kun: t5.zlu s May its zuio vnnu mziu s May its zuib MI I eK Industries, Inc. Wea J= 26 13:37:26 2019 2-6-3 2-6-3 2-6-3 12-6-3 2-6-3 Dead Load Den. = 3l8 in 5x8 = 10x14 MT20HS= 4x6 = 4x6 = 4x6 = 4x6 = 4x6 = 10x14 MT20HS= 5x8 = 13-0-5 LOADING (psf) SPACING- 2-0-0 CS'- DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.91 Vert(LL) -0.65 15 >381 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.00 BC 0.94 Vert(CT) -1.01 15 >244 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.54 Horz(CT) 0.12 11 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 439 Ib FT = 10% LUMBER - TOP CHORD 2x6 SP 240OF 2.0E BOT CHORD 2x8 SP 240OF 1.8E WEBS 2x4 SP M 30 *Except* W1: 2x6 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 cc bracing: 15-16,14-15. REACTIONS. (lb/size) 19 = 10318/0-5-0 (min.0-2-14) 11 = 6925/0-8-0 (min. 0-1-15) Max Grav 19 = 10318(LC 1) 11 = 6925(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-1 9=-2784/0, 1-20=-1 974/0, 20-21=-1974/0, 2-21=-1974/0, 2-22=-20029/0, 3-22=-20029/0, 3-23=-32678/0, 4-23=-32678/0, 4-24=-39296/0, 24-25=-39296/0, 5-25=-39296/0, 5-26=-41140/0, 26-27=-41140/0, 6-27=41140/0, 6-28=-38281/0, 28-29=-38281/0, 7-29=-38281/0, 7-30=-30689/0, 30-31=-30689/0, 8-31=-30689/0, 8-9=-17670/0, 9-10=-1459/0, 10-11=-892/0 BOT CHORD 18-19=0/13073, 17-18=0/28085, 16-17=0/37246, 15-16=0/41496, 14-15=0/40914, 13-14=0/35777, 12-13=0/25702, 11-12=0/10305 WEBS 2-19=-12842/0, 2-18=0/8443, 3-18=-9778/0, 3-17=0/5576, 4-17=-5544/0, 4-16=0/2489, 5-16=-2671/0, 5-15=-433/0, 6-15=0/273, 6-14=-3196/0, 7-14=0/3040, WEBS 2-19=-12842/0, 2-18=0/8443, 3-18=-9778/0, 3-17=0/5576, 4-17=-5544/0, 4-16=0/2489,. 5-16=-2671/0, 5-15=-433/0, 6-15=0/273, 6-14=-3196/0, 7-14=0/3040, 7-13=-6176/0, 8-13=0/6053, 8-12=-9750/0, 9-12=0/8940, 9-11=-10235/0 NOTES- 1) 3-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 cc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 cc. Webs connected as follows: 2x4 -1 row at 0-7-0 cc, Except member 2-18 2x4 - 1 row at 0-9-0 cc, member 18-3 2x4 -1 row at 0-9-0 cc, member 3-17 2x4 -1 row at 0-9-0 oc, member 17-4 2x4 -1 row at 0-9-0 oc, member 4-16 2x4 -1 row at 0-9-0 oc, member 16-5 2x4 -1 row at 0-9-0 cc, member 5-15 2x4 - 1 row at 0-9-0 cc, member 15-6 2x4 -1 row at 0-9-0 cc, member 6-14 2x4 -1 row at 0-9-0 oc, member 14-7 2x4 - 1 row at 0-9-0 oc, member 7-13 2x4 - 1 row at 0-9-0 oc, member 13-8 2x4 - 1 row at 0-9-0 cc, member 8-12 2x4 -1 row at 0-9-0 cc, member 12-9 2x4 -1 row at 0-9-0 oc, member 9-11 2x4 - 1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) All plates are MT20 plates unless otherwise indicated. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-10=-110, 11-19=-20 Concentrated Loads (lb) Vert: 7=-592 5=-592 8=-1178 9=-586 20=-1686 21=-1640 22=-1624 23=-1624 24=-901 25=-592 26=-592 27=-592 28=-592 29=-592 30=-592 31=-592 Job Truss Truss Type Qty Ply A0261165 V TRMAV2 FG04 FLOOR 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:27 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-gNvL3NkhglCgPfyL1 bOXISMyZFDOwo5nD63XNxz2Pcc 15-4 4 5-1-3 7-4 4 9-10 13 14-8-8 1 -2- 19-5-4 21-11-4 26-0-4 2 -0 5-1-3 2-3-1 4-9-11 -6 4-1-0 2-6-0 4-1-0 0- - 2 0-1-8 Dead Load Deg. =1/8 in 3x6 11 3x4 11 4x8 = 6x8 = 3x6 11 4x6 = 1 2 3 4 5 6 7 4x6 = 3x4 11 8 9 10 18 19 20 17 16 15 14 13 1211 5x6 = 1.5x4 11 4x4 = 4x4 = 1.5x4 11 1.5x4 11 4x4 = 5-1-3 7 4 4 9-10-13 14-8-8 15 4�4 19-5-4 20-8-4,21-11-4, 26-0 4 2, 4-0 5-1-3 2-3-1 M-9 4-9-11 -7-1 4-1-0 1-3-0 1-3-0 4-1-0 0- - 2 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.68 Vert(LL) -0.20 17-18 >898 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.00 BC 0.82 Vert(CT) -0.33 17-18 >543 240 BCLL 0.0 Rep Stress Incr NO WB 0.45 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 162 Ib FT = 10% LUMBER - TOP CHORD 2x8 SP 240OF 1.8E BOT CHORD 2x4 SP No.3 *Except` B1: 2x4 SP 240OF 2.OE, B3: 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* W1: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-18, 2-16 REACTIONS. (lb/size) 18 = 816/Mechanical 10 = 304/0-3-0 (min.0-1-8) 5 = 101110-4-12 (min.0-1-8) Max Grav 18 = 823(LC 3) 10 = 328(LC 4) 5 = 1011(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-8=-454/0 BOT CHORD 18-19=0/1344, 19-20=0/1344, 17-20=0/1344, 16-17=0/1344, 4-16=0/293, 14-15=0/454, 13-14=01454, 12-13=0/454 WEBS 2-18=-1119/0, 2-16=-132710, 7-15=-484/0, 8-12=-445/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) The Fabrication Tolerance at joint 3 = 10% 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 223 lb down at 1-5-4, and 223 lb down at 3-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others., 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-9=-55, 9-10=-55, 16-18=-10, 11-15=-10 Concentrated Loads (lb) Vert: 19=-223(B)20=-223(B) Job Truss Truss Type Qty Ply UVTRMAV2 FG05 FLOOR 1 2A0261166 Job Reference(optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:27 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-gNvL3NkhglCgPfyL1 bOXISM2HFMIwuvnD63XNxz2Pcc 3-11-4 1 Fy44h6-0 , 3-11-4 0-6r.?X4 11 3x4 = T1 W1 W2 I W1 W1 B1 6 5 4 3x4 = 1.5x4 II 2x4 II 3-11 4 4-6-0 , 3-11-4 0-6-12 LOADING (psf) SPACING- 1-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.31 Vert(LL) -0.01 5-6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.00 BC 0.20 Vert(CT) -0.01 5-6 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.08 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 51 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6 = 218/Mechanical 4 = 874/Mechanical Max Grav 6 = 218(LC 1) 4 = 874(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-359/0 WEBS 2-5=0/328 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) Refer to girder(s) for truss to truss connections. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 818 lb down at 3-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-3=-55, 4-6=-10 Concentrated Loads (lb) Vert: 5=-818(B) Job Truss Truss Type Qty Ply A0261167 WTRMAV2 HA Diagonal Hip Girder 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:28 2019 Page 1 I D:YwMtazYTmRGkHb8J_pTy?Kyn003-BaTkGjlJb2Kh1 pWXbJwmrgvEifiNfLNwSmp4wOz2Pcb -0-9-3 4-2-3 0_9_3 4-2-3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.01 4-5 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.17 Vert(CT) -0.01 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings Mechanical except at --length) 2=1-5-0, 5=0-3-8. (lb) - Max Horz 2= 91(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 3, 2 except 5=-125(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 4 except 5=344(LC 21) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) Concentrated loads from layout are not present in Load Case(s): #101 1 st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2 except at=lb) 5=125. . 9) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 98 lb down and 140 lb up at 1-4-9 on top chord, and 13 lb down and 31 lb up at 1-4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90, 4-6=-20 Concentrated Loads (lb) Vert: 7=42 8=-13(F) PLATES GRIP MT20 244/190 Weight: 14 lb FT = 10% Job Truss Truss Type Qty Ply WTRMAV2 HJ3A Diagonal Hip Girder 1 1 A0261168 Job Reference (optional) A T Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:29 2019 Page 1 I D:YwMtazYTmRGkHb8J_pTy?Kyn003-cm16U31xMMSYfy5j90R?NtSNw30hOop4hQYeSgz2Pca -1-10-10 2-0-2 4-2-3 1-10-10 2-0-2 2-2-0 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) -0.04 6-9 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.05 6-9 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.05 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 20 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 105/Mechanical 2 = 275/0-10-15 (min. 0-1-8) 5 = 8/Mechanical Max Horz 2 = 170(LC 8) Max Uplift 4 = -90(LC 33) 2 = -256(LC 4) 5 = -56(LC 8) Max Grav 4 = 105(LC 1) 2 = 370(LC 19) 5 = 249(LC21) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-275/70 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Concentrated loads from layout are not present in Load Case(s): #101 1 st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving. Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5 except Qt=lb) 2=256. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)139 lb down and 85 lb up at 1-4-9, and 139 lb down and 85 lb up at 1-4-9 on top chord, and 21 lb down and 50 lb up at 1-4-9, and 21 lb down and 50 lb up at, 1-4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-90, 5-7=-20 Concentrated Loads (lb) Vert: 10=170(F=85, B=85) 11=60(F=30, B=30) Job Truss Truss Type Qty Ply � W7RMAV2 HJ5 Diagonal Hip Girder 4 1 A0261169 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:30 201� Page 1 ID:YwMtazYTmRGkHbBJ_pTy7Kyn003-4yaUhPmZ7gaPG6gwjjyEw5_YgTM17DbDv41 B_Gz2PCZ 1-10-10 3-5-2 7-0-2 1-10-10 3-5-2 3-7-0 3x4 = 1.5x4 II 3-5-2 7-0-2 3-5-2 3-7-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) 0.02 6-7 >999 , 360 TCDL 15.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.03 6-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.15 Horz(CT) -0.01 4 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-10-8 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 4 = 146/Mechanical 2 = 387/0-10-15 (min. 0-1-8) 5 = 174/Mechanical Max Horz 2 = 256(LC 8) Max Uplift 4 = -115(LC 8) 2 = -329(LC 4) 5 = -157(LC 8) Max Grav 4 = 146(LC 1) 2 = 488(LC 19) 5 = 252(LC 35) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-614/205, 3-11=-517/216 BOT CHORD 2-13=-351/453, 7-13=-351/453, 7-14=-351/453, 6-14=-351/453 WEBS 3-6=-507/393 L,call I�'E 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf, h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for, truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=115, 2=329, 5=157. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 139 lb down and 85 lb up at 1-4-9, 139 lb down and 85 lb up at 1-4-9, and 190 lb down and 97 lb up at 4-2-8, and 190 lb down and 97 lb up at 4-2-8 on top chord, and 21 lb down and 50 lb up at 1-4-9, 21 lb down and 50 lb up at 1-4-9, and 31 lb down and 17 lb up at 4-2-8, and 31 lb down and 17 lb up at 4-2-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-90, 5-8=-20 Concentrated Loads (lb) Vert: 11=170(F=85, B=85)13=60(F=30, B=30) 14=-8(F=-4, B=-4) LO o PLATES GRIP MT20 244/190 Weight: 33 lb FT = 10% Job % Truss Truss Type Qty Ply WTRMAV2 HR Diagonal Hip Girder 1 1 A0261170 Job Reference (optional) A -IT Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:30 2019 Page 1 I D:YwMtazYTmRGkHbBJ_pTy?Kyn003-4yaUhPmZ7gaPG6gwjiyEwS_UETH H753Dv41 B_Gz2PcZ -0-9-3 , 5-3-15 9-10-1 0-9-3 5-3-15 4-6-1 5-3-15 4-6-1 Plate Offsets (X,Y)-- f2:0-2-0,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.08 7-9 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.59 Vert(CT) -0.10 7-9 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.69 Horz(CT) 0.02 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 47 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-2-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-1-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 198/Mechanical 2 = 717/1-5-0 (min. 0-1-8) 5 = 522/Mechanical Max Horz 2 = 189(LC 28) Max Uplift 4 = -150(LC 4) 2 = -444(LC 4) 5 = -272(LC 8) Max Grav 4 = 198(LC 1) 2 = 717(LC 1) 5 = 522(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-17001902, 3-1 0=-1 642/908 BOT CHORD 2-12=-842/1258, 12-13=-842/1259, 2-13=-843/1260,2-14=-1001/1643, 14-15=-1001/1643, 7-15=-1001/1643, 7-16=-1001/1643, 16-17=-1001/1643, 6-17=-1001 /1643 WEBS 3-7=-95/336,3-6=-1709/1041 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Concentrated loads from layout are not present in Load Case(s): #101 1st Moving Load; #201 2nd Moving Load; 4301 3rd Moving Load; #401 4th Moving Load; 4501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load; #801 8th Moving Load; #901 9th Moving Load. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 4=150, 2=444, 5=272. 7) This truss has been designed for a moving concentrated load of 200.0111b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 66 lb down and 68 lb up at 4-2-8, 66 lb down and 68 lb up at 4-2-8, and 110 lb down and 141 lb up at 7-0-7, and 110 lb down and 141 lb up at 7-0-7 on top chord, and 13 lb down and 31 lb up at 1-4-9, 13 lb down and 31 lb up at 1-4-9, 22 lb down and 26 lb up at 4-2-8, 22 lb down and 26 lb up at .4-2-8, and 52 lb down and 37 lb up at 7-0-7, and 52 lb down and 37 lb up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Standard Uniform Loads (plf) Vert: 1-4=-90, 2-5=-20 Concentrated Loads (lb) Vert: 11=-120(F=-60, B=-60) 13=-26(F=-13, B=-13) 15=45(F=-22, B=-22) 16=-105(F=-52, B=-52) Job Truss Truss Type Qty Ply WTRMAV2 HJ7B Diagonal Hip Girder 1 1 A0261171 Job Reference (optional) H-1 KooT 1 russes, rOn coerce, I-L o4u4o, oeslgn(Nal IIUss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:31 20119 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-Z98sulnCuziGuGF6GRTTTIXelshcsayM8k1 kWjz2PcY 3x4 = 3x4 = 2x4 11 4x4 = 9-10-1 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/defl L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.03 6-7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.04 6-7 >999 240 BCLL 0.0 * Rep Stress lncr NO WB 0.52 Horz(CT) -0.01 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-4-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-3-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 209/Mechanical 2 = 583/0-10-15 (min. 0-1-8) 5 = 431/Mechanical Max Horz 2 = 342(LC 8) Max Uplift 4 = -198(LC 8) 2 = -358(LC 4) 5 = -275(LC 8) Max Grav 4 = 209(LC 1) 2 = 694(LC 44) 5 = 512(LC 44) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-1 0=-1 2091449, 10-11=-1197/496, 3-11=-1035/467 BOT CHORD 2-13=-614/993, 2-14=-614/997, 14-15=-614/997, 15-16=-614/997, 7-16=-614/997, 7-17=-614/997, 6-17=-614/997 WEBS 3-7=-14/331, 3-6=-1098/676 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf, BCDL=S.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Concentrated loads from layout are not present in Load Case(s): #101 1 st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load; #801 8th Moving Load; #901 9th Moving Load. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=198, 2=358, 5=275. 8) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)134 lb down and 86 lb up at 1-4-9, 134 lb down and 86 lb up at 1-4-9, 185 lb down and 85 lb up at 4-2-8, 185 lb down and 85 lb up at 4-2-8, and 251 lb down and 175 lb up at 7-0-7, and 251 lb down and 175 lb up at 7-0-7 on top chord, and 27 lb down and 50 lb up at 1-4-9, 27 lb down and 50 lb up at 1-4-9, 33 lb down and 17 lb up at 4-2-8, 33 lb down and 17 lb up at 4-2-8, and 60 lb down and 35 lb up at 7-0-7, and 60 lb down and 35 lb up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). PLATES GRIP MT20 244/190 Weight: 51 lb FT = 10% LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-90, 2-5=-20 Concentrated Loads (lb) Vert: 10=172(F=86, B=86) 12=-114(F=-57, B=-57) 14=61(F=30, B=30) 16=-16(F=-8, B=-8) 17=-86(F=-43, B=-43) Job Truss Truss Type Qty Ply % A0261172 WTRMAV2 HJ7C Diagonal Hip Girder 1 1 Job Reference (optional) A- 'Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:32 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-1 LiE65ogfHg7WQglqB_i?W3piG1 sbi kWNOnl39z2PcX 5-0-14 9-10-1 5-0-14 4-9-2 3x4 = 3x4 = `^v 0- -6 5-0-14 9-10-1 0- -6 5-0-8 4-9-2 Plate Offsets (X,Y)-- i1:0-7-5,0-2-31,f1:0-0-0,0-0-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL) 0.03 5-6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.04 5-6 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.55 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 48 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-2-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-7-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 523/0-10-9 (min. 0-1-8) 3 = 208/Mechanical 4 = 482/Mechanical Max Horz 1 = 298(LC 8) Max Uplift 1 = -263(LC 8) 3 = -197(LC 8) 4 = -313(LC 8) Max Grav 1 = 655(LC 43) 3 = 208(LC 1) 4 = 533(LC 44) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-1273/536, 9-10=-1241/565, 2-10=-1081 /533 BOT CHORD 1-12=-714/1050, 1-13=-716/1055, 13-14=-716/1055, 14-15=-716/1055, 6-15=-716/1055, 6-16=-716/1055, 5-16=-716/1055 WEBS 2-6=-63/343, 2-5=-1162/788 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Concentrated loads from layout are not present in Load Case(s): #101 1 st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load; #801 8th Moving Load; #901 9th Moving Load. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 1=263, 3=197, 4=313. 8) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 118 lb down and 28 lb up at 1-4-9, 133 lb down and 85 lb up at 1-4-9, 183 lb down and 95 lb up at 4-2-8, 185 lb down and 85 lb up at 4-2-8, and 250 lb down and 180 lb up at 7-0-7, and 251 lb down and 175 lb up at 7-0-7 on top chord, and 10 lb down and 16 lb up at 1-4-9,.27 lb down and 50 lb up at 1-4-9, 31 lb down and 29 lb up at 4-2-8, 33 lb down and 17 lb up at 4-2-8, and 59 lb down and 42 lb up at 7-0-7, and 60 lb down and 35 lb up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90, 1-4=-20 Concentrated Loads (lb) Vert: 9=85(B) 11=-121(F=-64, B=-57) 13=21(F=-9, B=30) 15=-29(F=-21, B=-8) 16=-94(F=-51, B=-43) Job Truss Truss Type Qty Ply WTRMAV2 HJ7W Diagonal Hip Girder 1 1 AO261173 v; Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 6.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:33 201J Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-VXGdJRoSQby_7aPUOsVxYjc?NgLnKTsfc2W rbbz2PcW -0-9-3 5-3-15 9-10-1 0-9-3 5-3-15 4-6-1 Plate Offsets LOADING (psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 * Rep Stress Incr NO BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-5-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-9-8 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 199/Mechanical 2 = 595/1-5-0 (min. 0-1-8) 5 = 485/Mechanical Max Horz 2 = 192(LC 31) Max Uplift 4 = -167(LC 8) 2 = -513(LC 4) 5 = -526(LC 4) Max Grav 4 = 199(LC 1) 2 = 595(LC 1) 5 = 485(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-1 079/891, 2-11 =-1538/1389, 3=11=-1480/1395 BOT CHORD 2-13=-979/1019, 2-14=-1475/1484, 14-15=-1475/1484, 7-15=-1475/1484, 7-16=-1475/1484, 16-17=-1475/1484, 6-17=-1475/1484 WEBS 3-7=-315/336, 3-6=-1543/1534 9-10-1 CSI. DEFL. in floc) I/deft L/d TC 0.59 Vert(LL) 0.09 7 >999 360 BC 0.48 Vert(CT) -0.08 7-9 >999 240 WB 0.62 Horz(CT) -0.02 5 n/a n/a Matrix -MS NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf, h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Concentrated loads from layout are not present in Load Case(s): #101 1 st Moving Load; #201 2nd Moving Load; #301 3rd Moving Load; #401 4th Moving Load; #501 5th Moving Load; #601 6th Moving Load; #701 7th Moving Load; #801 8th Moving Load; #901 9th Moving Load. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 4=167, 2=513, 5=526. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with, any other live loads. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)197 lb down and 281 lb up at 1-4-9, 47 lb down and 47 lb up at 4-2-8, 47 lb down and 47 lb up at 4-2-8, and 110 lb down and 163 lb up at 7-0-7, and 110 lb down and 163 lb up at 7-0-7 on top chord, and 75 lb down and 1 lb up at 4-2-8, 75 Ib down and 1 lb up at 4-2-8, and 52 lb down and 139 lb up at 7-0-7, and 52 lb down and 139 lb up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 47 lb FT = 10% Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-90, 2-5=-20 Concentrated Loads (lb) Vert: 10=85 12=-120(F=-60, B=-60) 15=2(F=1, B=1) 16=-104(F=-52, B=-52) Job 1� Truss Truss Type Qty Ply A0261174 WTRMAV2 J3 JACK -OPEN 3 1 Job Reference (optional) A -?'Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:34 2019 Page 1 ID:YwMtazYTmRGkHb8J_pTy?Kyn003-zjq?Xnp4Bu4dk_hyZ1 A4w9FH4ly33spgiGO71 z2PCV 1 4-0 3-0-0 1-4-0 3-0-0 0 O N 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.01 4-7 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.22 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.01 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 12 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 105/Mechanical 2 = 299/0-8-0 (min.0-1-8) 4 = 32/Mechanical Max Horz 2 = 170(LC 12) Max Uplift 3 = -108(LC 12) 2 = -108(LC 12) 4 = -4(LC 12) Max Grav 3 = 130(LC 19) 2 = 299(LC 1) 4 = 54(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=108, 2=108. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply I A0261175 WTRMAV2 J3A Jack -Open 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:34 201"d Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-zjq?Xnp4Bu4dk_hyz1 A4w9Ho4mU33spgiGO71 z2PcV -0-6-8 3-0-0 0-6-8 3-0-0 2x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/defl Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.17 Vert(LL) -0.01 4-7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 107/Mechanical 2 = 210/0-8-0 (min. 0-1-8) 4 = 51/Mechanical Max Horz 2 = 90(LC 8) Max Uplift 3 = -78(LC 12) 2 = -120(LC 8) 4 = -12(LC 12) Max Grav 3 = 107(LC 1) 2 = 210(LC 1) 4 = 55(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left .exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb) 2=120. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 10 lb FT = 10% Job 4 Truss Truss Type Qty, Ply WTRMAV2 J5 JACK -OPEN 20 1 A0261176 Job Reference (optional) A-9 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 2613:37:35 2019 Page 1 ID:YwMtazYTmRGkHb8J—pTy?Kyn003-RwONk6gixCCiNtZtVHYPd8hibU?xoW6y3M?yfuz2PcU -1-4-0 5-0-0 1 4-0 5-0-0 46 = 5-0-0 5-0-0 Plate Offsets (X,Y)— i2:0-0-0,0-1-51 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.74 Vert(LL) -0.07 4-7 >837 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.56 Vert(CT) -0.11 4-7 >543 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.02 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 18 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 190/Mechanical 2 = 399/0-8-0 (min.0-1-8) 4 = 67/Mechanical Max Horz 2 = 256(LC 12) Max Uplift 3 = -186(LC 12) 2 = -131(LC 12) 4 = -1O(LC 12) Max Grav 3 = 230(LC 19) 2 = 399(LC 1) 4 = 95(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. Il; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=186, 2=131. LOAD CASE(S) Standard Job Truss Truss Type city Ply WTRMAV2 J7 Jack -Open 5 1 'A0261177 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:36 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-v6ylySrKiWKZ? 1833_3eALEPKtKIXzL5101VCwz2PcT ,-0-6-8, 7-0-0 0-6-8 7-0-0 3x6 LOADING (ps2 SPACING- 2-0-0 CSI. TCLL 30.0 Plate Grip DOL 1.25 TC 1.00 TCDL 15.0 Lumber DOL 1.25 BC 0.59 BCLL 0.0 * Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017[TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 228/Mechanical 2 = 428/0-8-0 (min. 0-1-8) 4 = 152/Mechanical Max Horz 2 = 189(LC 8) Max Uplift 3 = -176(LC 12) 2 = -210(LC 8) 4 = -38(LC 12) Max Grav 3 = 228(LC 1) 2 = 428(LC 1) 4 = 294(LC 27) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. Dead Load DeFl. = 1116 In N M N DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.14 4-6 >605 360 MT20 244/190 Vert(CT) -0.13 4-6 >617 240 Horz(CT) -0.00 4 n/a n/a Weight: 28 lb FT = 10% 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except at --lb) 3=176, 2=210. 6) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job i Truss Truss Type Qty Ply A0261178 V TRMAV2 J7B Jack -Open 6 1 Job Reference (optional) A-i Roof Trusses, -Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:37 2019 Page 1 I D:YwMtazYTmRGkHbBJ_pTy?Kyn003-N I W79osyTpSQcBiGdhatiZnexHg?GQbFWgU3kMz2PcS -1-4-0 7-0-0 1-4-0 7-0-0 3x8 G LOADING (psf) SPACING- 2-0-0 CS'_ DEFL. in (loc) I/defl L/d TCLL 30.0 Plate Grip DX 1.25 TC 0.75 Vert(LL) 0.22 4-7 >386 360 TCDL 15.0 Lumber DOL 1.25 BC 0.59 Vert(CT) -0.34 4-7 >246 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.01 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEDGE Left: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-6-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 268/Mechanical 2 = 505/0-8-0 (min.0-1-8) 4 = 104/Mechanical Max Horz 2 = 342(LC 12) Max Uplift 3 = -253(LC 12) 2 = -167(LC 12) 4 = -16(LC 12) Max Grav 3 = 321(LC 19) 2 = 508(LC 19) 4 = 274(LC 27) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph;,TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except at=lb) 3=253, 2=167. 6) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard 19 v Dead Load Defl. = 118 in PLATES GRIP MT20 244/190 Weight: 25 lb FT =10%a Job Truss Truss Type Qty Ply WTRMAV2 PC Jack -Open 2 1 ' A0261179 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:37 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy1Kyn003-NI W79osyTpSQcBiGdhatiZnfTHiFGQbFWgU3kMz2PcS 7-0-0 3x6 = 7-0-0 Plate Offsets (X,Y)-- [1:0-3-3,0-1-81 LOADING(psf) SPACING- 2-0-0 CSI. TCLL 30.0 Plate Grip DOL 1.25 TC 0.65 TCDL 15.0 Lumber DOL 1.25 BC 0.51 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP 2400F 2.0E BOT CHORD 2x4 SP M 30 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 382/Mechanical 2 = 277/Mechanical 3 = 105/Mechanical Max Horz 1 = 299(LC 12) Max Uplift 1 = -98(LC 12) 2 = -260(LC 12) 3 = -16(LC 12) Max Grav 1 = 386(LC 19) 2 = 332(LC 19) 3 = 274(LC 27) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. Dead Load Defl. =1/8 in o v v DEFL. in (loc) I/deft L/d PLATES GRIP Vert(LL) 0.22 3-6 >379 360 MT20 244/190 Vert(CT) -0.31 3-6 >267 240 Horz(CT) 0.01 2 n/a n/a Weight: 23 lb FT = 10% 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Qt=1b) 2=260. 6) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job , Truss Truss Type Qty Ply WTRMAV2 J7W Jack -Open 4 1 A0261180 Job Reference (optional) A-T Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 0-6-8. 46 ._ 7 Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:38 2019 Page 1 I D:YwMtazYTmRGkHbBJ_pTy?Kyn003-rV3WM8sbE7bH ELHSBP56FmJsDh3a?trOIKEcGpz2PcR 7-0-0 7-0-0 pj N N LOADING (psf) SPACING- 2-0-0 CS'. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plate Grip DX 1.25 TC 0.52 Vert(LL) 0.20 4-6 >416 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.44 Vert(CT) 0.18 4-6 >459 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 28 lb FT = 10% LUMBER - TOP CHORD 2x4 SP 2400F 2.0E BOT CHORD 2x6 SIP 2400F 2.0E BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 228/Mechanical 2 = 428/1-0-0 (min. 0-1-8) 4 = 152/Mechanical Max Horz 2 = 192(LC 8) Max Uplift 3 = -188(LC 8) 2 = -385(LC 8) 4 = -201(LC 8) Max Grav 3 = 228(LC 1) 2 = 428(LC 1) 4 = 294(LC 27) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=188, 2=385, 4=201. 6) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply V TRMAV2 VM02 Valley 1 1 �A0261181 V Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com C a 0 Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Jun 26 13:37:38 2019 Page 1 ID:YwMtazYTmRGkHbBJ_pTy?Kyn003-rV3 WM8sbE7bHELHSBP56FmJzlh92?trOIKEcGpz2PcR 2-0-0 2-0-0 2x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.07 Vert(LL) n/a - n/a 999 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.02 Vert(CT) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight: 5 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 80/1-11-9 (min.0-1-8) 2 = 66/1-11-9 (min.0-1-8) 3 = 15/1-11-9 (min.0-1-8) Max Horz 1 = 63(LC 12) Max Uplift 1 = -21(LC 12) 2 = -65(LC 12) Max Grav 1 = 81(LC 19) 2 = 79(LC 19) 3 = 29(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp D; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. LOAD CASE(S) Standard 41 JANUARY 17, 2017 I TYPICAL HIP / KING JACK CONNECTION I STDTLOI CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 Attach End Jack's w/ (4) 16d Toe Nails @ TC & (3) 16d Toe Nails @ BC Attach King Jack w/ (3) 16d Toe ,Nails @ TC & 24" Strap w/ (6) 10d x 1.5" ea. end @ BC r� 0 ti ttach Corner Jack's r/ (2) 16d Toe Nails @ TC & BC (Typ) Attach Corner Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) ATERASS&CONDMO"SCIJSTV,.ERCBUYER)AGQtO'hIBGELOfPfamVdyde*para119ersardmad beuselbrbeTDDb �sad.tsaTrussDevgnEngnee(e.,5�tayyEn,meE),besealroany Mrep sub an acceplanced(fepa[esscra;e�reerh9reslSnsbityfathedesgnofkshgkTnssdefadedcnfieiDDa�:'g�TPFl.Thedeswna<suryfora,badigrw4�anssug>btyaduseolUdsTnssf_arty MA-IROO GO*gi fterespnnsbkofftama,UmCrealsa hrMaq-AorfheBuMmgDe4er,inthem*doflhelRC,Ih:IBD,LFelea16ffgwieandTPIThesppo4d1hsTDDandanyfieldmedMeTruss,Gdudmghardhg,sto-age,instal!aceandWM,sha0beff�respans1lyoftlreBu rg AA RMSE5 DesiglrandCor"ad;x.Alinc€ess°lorlm$:eTDDandlFapacF: a'dquitlelussdlheBuOdingCompaact&a?a'ylninrmaGin(BCS'jpdtSshedby7P1am1SBi,Fa.Rra�rencedbrgea .I guilance.TP4ldefeNslharespons6'ktiesa7dd::Eesd;haTrussDaz�ner,Speda°yFsgsfaetandTnsvblawfa6mr, y,rRD[FM&M:• zlezehmise&Mbya M-A" gmin wdta �j 0 peasiviloNed Tha4wa4Egg ieerisodbeSuVgDe orTnssSiyd=Engaaerfaranykff*A1Cap1- WtemsareasdefAdinTPE1. 4QfAL=1 Onw*W 02316A-1RrdTm s-Reamdobnafthisd=W.inamifomEwdWedwiihwrgancerr&mfirmA-1RoolTnnes. r�tFvFL34Ea FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD 1' - 3' MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE'CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 0 24' O.C. 2X6 DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 15d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). ' PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. END WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) DR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-96, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). I / STRUCTURAL GABLE TRUSS / MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALl BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED \S ARE NOT ADDRESSED HERE. / STANDARD GABLE / \S / UKAL TRUSS I'- , STUD AN ADEDUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. JULY 17, 2017 STANDARD PIGGYBACK TRUSS STDTL04 CONNECTION DETAIL Aw �i THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: ■ ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE �! CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN DRAWING FOR UPLIFTS. �t — NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24" O.C. OR LESS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' O.C.) A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. be v& As a Truss Design Eno, (Le, Spy alry unless oNarsise G":rad try a Catdrad agraal open m tsira0 by ag pales much2d CopytgM �' �toA-f �inaf TN53ea-neprodu�W1 Cf Ible dOCJmefd, manyfwm to ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2" X 8" TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48" O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48" O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 2" X 8" TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. w iss TNS;L��n Orating jIDO} ad tlaErgneecg Pefe;enre Seel In:Brause. Unless aB�araae sfsfed on9�eTDD,only brg oxnesbrp!ates shad ba usedfm CneTDD N =nWe.*wingmp=t tyfa5edes�nofftsag6P=depdedonhTDDonly,underTPH.Thedesignassumpons,loadingoDftr%svbRfi and useofftTNssiosanf the IBC, INIDMWhgc ardTPatThgpmraothTDDand rnyfudduseoffheTruss, Wgrighandng,swage,hstallamand basg,slulbelhemsponsLTlydlheNMI amAnIBM pftedbyMail SBCAaarAmrmdforgeneralguemxTPMdafnesfhsnspo tgesmdduksofheTruss Ltsgmr,W1&gkwandTruss ld mL%Iu ,, .ding DsnerorTawSysfemEngiw' rmybuilig.AllCapbadlensamasd*ad�TPA ��A-4 enS a7RlEMS Ri Rorrnls; :• 443I31m&W m%m,FL 3m JULY 17, 2017 I TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 .y A-1 ROOF TRUSSES AAM cr r uric Q1 vn FOF SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6" O.C. ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO USP WS45 (1/4" X4.5") WOOD SCREWS INTO EACH BASE TRUSS. DETAIL A GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 4.5" WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. -E END, COMMON 3S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24" O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. TFRM58C0RDmONSCUSTCM-eR('BiIYER)ACIINOr51EDGElkNi`lum��'arifydesl3nparama;meerJreadncfesan6tisTrvs,Das�nDtaa7ng(tDD)and�eEngine�mgRakrenceSheetbet�ausa.UrJ�safneraisesSatedonB�eTDD,afycortesponlu�gwnnedmp�:asaha46eus_�fartfreiDDro �_ bevaEdAsaTn�Deslgnfrgcezf(i.e,Spsaatry �rj,Lhasa��arryTODrepeserJsanazxep(anceofihepmf sronaEe eering�tybrfnadas,na{ness�,leTnssde anBwiDDonFj,underTPll.ThadsSgnassunpotsbadugcand�uns,5laaT�8rd6a0IN3Tn64� fl� A.1RBaF I Bu iga&erespmsMyot9e0ane,fee0wetsa&m¢csla3sntaae6u gDeS er,rlhemntedalthelRC,hIBC,tre3ocalbugdr}codeandTPM.TheappmdotfheTDDzrianjFedLseof9aTtuss r4ufi@ hmftgslrage, VgYdm wd bam,shagbelh mpftfffly oi IhD Bumhg -muses Des@mrandCaTta brAlrioasselwtmt oMDandbpradmandguidefinesatlh EWding Coponot8gleylht ma6m(MQpabCishedbyTPlandSBCAamrdemnAlorgeneraloanm PhidehnesthamspsiV099mddusofhTmss1)8sgrxr,Spec&Y EnoexrandTmssManui um-, �f unle�athenssedefinedbyaCnntrategmeduponmm mg7yaUpaz6esnveAcd.TheSpeca461&L=&t COD*4P,2016kiRadTmses-RWAddDnefftdowner�manyfmREpAbtWW.Ihwr&..p-m&..m. bmaA-111W.Trmas. FvtPtqR3M FEBRUARY 5, 2018 I TRUSSED VALLEY SET DETAIL I STDTL06 C GENERAL SPECIFICATIONS: ® 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 3"WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL rrr "A„ 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. FORT PIERCE, FL 34946 TRUSS, OR GIRDER 772-409-1010 TRUSS VALLEY TRUSS y II I rt I II II IIBASE TRUSSES (TYPICAL) II tr GABLE END, COMMON TRUSS, OR GIRDER P F —1? VALLEY TRUSS TRUSS /*s— (TYPICAL) SEE DETAIL "A" BELOW (TYP.) SECURE VALLEY TRUSS ' W/ ONE ROW OF 10d WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH NAILS 6" O.C. WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/TWO USP MAX SPACING = 24" O.C. (BASE AND VALLEY) WS3 (1/4" X 3") WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. INTO EACH BASE TRUSS. (NO SHEATHING) N.T.S. T ERAS S CONO MONS CUSTOSEn ('BUY`tq AG(MD&BG Wrt[P form uerihj desFpnme'as"real idu en ba Tnas Dmsa beisH.As a Tn�s Dasgn Erc nee (.e., Spec0ylinginrrr).5e seal on arry7LO mpmjb w amaptmceof fne pro?essmnaleng'rwkg r 8iliang i the msponsmij ate Omer, hNnes ejk cad aged or h Ba' fig Designer, inIheccrWof te IRC, the W, OvlodbU unless e5eruise de6ndby a Cmtradagredupm in wiling byall� invo'.rd. TM S�iaky CpM, , 92016A-1Rod Trusses -Reprdutonof5sdroimerl,6anylatRapdbWwh I1MErg'sargRel ea Red heforause.Unless; oft•ase geledontaTDD,WycDmFdNranaedorplat"albeused burtheTDDb desk atlnesagleTru;sdepkldonthe TDDo*,WvTPI-I.Thedeign assump.%loaixgcondbans,subbkonduseatfosTrussiorany . Theapprouald5e TDD and anyfia'd u;edSeTmss,indudsg handing, s o-age, ka7afmn and brwg, shdbe%respons5&fiyof the B", Mwe re'ruencedforgenardguidance. TPA defines themspam�3Ees anddinscf5eTruss Dora, SpeaalyE*iaerandTruss Marafntmr, bramNigTA. MCaaTaraedlams alas defined6 TPI-1. I 'A-1 ROOF Fri 60RrZ'Ja'iS WIRUMEW FvtPe¢,FC:Cs4 1 \VVVLV Vf-ILLL 1 %JL— VL I f1STDTL07 1L JULY 17, 2017 (HIGH WIND VELOCITY) , A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD- FORT PIERCE, FL 34946 772-409-1010 ATTAC WIND DESIGN PER ASCE 7-98, ASCE 7-1 WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24" O.C. (BASE AND VA I SUPPORTING TRUSSES DIRECTLY UNGrm VALLcr I muoo. CA MUJ I cc DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON -BEVELED MAXIMUM 6/12 PITCH BOTTOM CHORD FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. NON -BEVELED BOTTOM CHORD. CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/12 PITCH) TEBtd58 Cdf1DRIONS CUSTOM:R ('BfIYEt� Arf{NOWCEOoRtBdT`hrtn Vertlydesga pan be v� As a TN>s Dasgn Encineer (e., Spz�a>`jr Engir�er), the seal on arty TOD repraserds an. ' Buddmg�breTonsSTdyofbOwer, Ina OuelsauiMMapt orthe &uldingDesiggnar,n unlesDesiyrerardCv.hlor.A7rw'_sseta inbTDDandthepracfmudpk masd%Buddmt s oberaise dellred by a UI rA agreed uponin tribig by ad parts mvdvad Re Spedalry y tons a des gn ol9resaglzTNss �p ted on Ine TDD crly, uraierTPF1.The dcu ressumphors; bad rg condt ons,sudanddy anN�aTn -inu� and TPKThe approval oftheTDDandanyhelduse oftheTrm,nludaghandmg,storage, insdafionand Wng,slbetheremsoTfthe&(ufgy 'and SBCAaramfuencedforgeneudgidarm TI'll definesbraWLIffwaridduhesofteTNssDestw,Spei*ErgiwardTnmgandacturer, kr � Engm�rfsrasybuddmg.AhCapia'�,itermsa�easdefneiiniPl-1. gair��,sa�a ndGwa R slam: FEBRUARY 17, 2017 I STANDARD GABLE END DETAIL I STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYPICAL 2X4.L-BRACE NAILED TO 2X4 VERTICALS W/lOd. NAILS, 6. O.C: VERT STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES * WITH. (2) - 10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Bd NAILS MINIMUM, ROOF B 3X4= PLYWOOD SHEATHING TO 1 SHEATHING 2X4 STD SPF BLOCK VERTICAL 2X6 SP OR SPF STUDVBTB,RACE #2 DIAGONAL BRACE (4) - 16dNAILS16d NAILS SPACED 6' O.C. (2) lOd NAILSINTO 2X62X6 SP OR SPF #2 2X4 SP OR SPF #2L HORIZONTAL NAILED TO RTICALS SECTION A -A /(4) - 10d NAILS * DIAGONAL BRACING 9C* L' - BRACING REFER - REFER TO SECTION A -A TO SECTION B-B 24' MAX. OTE: / / 2. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM' CHORDS. (2) - 10d CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO 12' MAX. NAILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF 4. SYSTEM. 'L' BRACES SPECIFIED ARE TD BE FULL'LENGTH, SPF OR SP #3 OR / BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. o/ TRUSSES 0 24' D.C. 5. DIAGONAL BRACE TO -BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT 4' - 0' D.C. G. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' D.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48' D.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE __, TO VERTICAL WITH (4) - STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) ;'' 16d NAILS, AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. TO BLOCKING WITH (5) - B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. . DIAGBRACE. 10d NAILS. S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD - SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP #31 STUD 12" O.C. 3-8-10 5-6-11 6.6.11 11-1-13 2X4 SP #31 STUD 16" O.C. 3-3.10 4-9-12 6-6-11 9-10-15 2X4SP431STUD 24"0.C. 2-8-6 3-11-3 54-12 8-1-2 2X4 SP #2 12" O.C. 3-10-15 5-6-11 6-6-11 11-8-14 2X4SP#2 16"O.C. 3-6-11 4-9-12 6-6-11 10-8-0 2X4 SP #2 24" O.C. 1 3-1-4 1 3-11-3 6-2-9 9-3-13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS G' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 90Y OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. END WALL MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. FEBRUARY 17, 2017 I T WRTH 2XIBRACE ON Y IL I STDTL09� NOTES: T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER SOX OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6' O.C. NOTE. NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) NAILS \ � SPACING BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE . 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE T—BRACE /,I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS I -BRACE NAILS WEB T-BRACE SECTION DETAILS a FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. USE METAL FRAMING ANCHOR TO ATTACH TO TOP CHORD BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) WEB WITH (3) - 10d SCAB WITH (3) - 10d NAILS (0.131' X 31) NAILS (0.131' X 3'). r ATTACH TO VERTICAL NAILS (0. 313WITH )X 3') USE METAL FRAMING -J IF- ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0.131' X 3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH, (3) - 10d NAILS (0.131' X 3') TRUSS 2X6 4' - 0' WALL STRONGBACK (TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA.) INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) FEBRUARY 17, 2017 1 LATERAL TOE -NAIL DETAIL I STDTL11 11 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 o J .135 93.5 85.6 74.2 72.6 63.4 .162 108.E 99.6 86.4 84.5 73.8 pi .128 74.2 67.9 58.9 57.6 50.3 0 Z 0 J .131 75.9 69.5 60.3 59.0 51.1 .148 81.4 74.5 64.6 63.2 52.5 in N M VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30° TO 60" 45.00° ANGLE MAY VARY FROM 30° TO 60° THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE l0° FEBRUARY 17, 2017 UPLIFT TOE -NAIL DETAIL STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S 0 .131 59 46 32 30 z .20 J .135 60 48 33 30. 20 .162 t 72 58 39 37 25 J 2 0, .128 54 42 28 27 19 z Z O J .131 55 43 29 28 19 LLI .148 62 48 34 31 21 —1 Lo J_ N Q M Z .120 51 39 27 26 17 C� Z .128 49 38 26 25 17 OO .1,31 51 39 27 26 17 .148 1 57 44 31 28 20 M NOTES: 1. TOE —NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE —NAIL. APPLICABLE DURATION OF LOAD -INCREASES MAY BE APPLIED. EXAMPLE: (3) — 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 1.33 IDOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TD WIND FOR WIND OOL OF 1.60:, 3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. *+�* USE (3) TOE —NAILS ON 2X4 BEARING WALL *!+e USE (4) TOE —NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S: )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY [L NAIL NAIL SIDE VIEW END VIEW FEBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT I STDTL13 `` A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 -I .0 X 4 2x2 NAILER ATTACHMENT .. . GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10,. 29'-0" Mean Height, Exp. B, C or D. 1% TYPICAL ALTERNATE yApril 11, 2016 I FO EXTERIOR FLAT GIR EIR TRUSSIL I STDTLI4 A-1 ROOF TRUSSES 4451 ST. LUCIE,BLVD, FORT PIERCE, FL 34946 772-409-1010 (4) 12d 12 VARIES TRUSS 24" O.C. —\ _,-- (4) 12d MAX 30" (2'-6") UPLIFT CONNECTION (SEE ROOF TRUSS) 2x6 #2 SP (Both Faces) 24" O.C. EXTERIOR FLAT SIMPSON H5 GIRDER w!aawnwiiUraouuaivrnertaur cytrcmrtuisln�rxmvamya�epamrsenore�JnctssaPssTrussDnDresag;DDjas7lh�Ertis¢�ag6efssncaeetGHouse.DrssahwwsSed6eTDD,aaxjwmsxnuaEsssha7MusedtrgTDDto bediksainr Ns�E*w-(e.6p aL Engve*},th�s�ampiDDm,+eser asa da�edDap��savte. i agr yf�q'-d , oig sr�ceinRsOpdsdoahsiJDagy,underTP4l,itad �razsmyb�s,i agcm s<a*.dfsrd�ed Tn�ssiaary ' W4i is?:res akrditCmr,:^'h memmoi¢tdageet9ihaW� gC�esigner,�nftw.�e�do`ftIRC, b13C,MekralWi#rgco�WTNANapsxodottFaIDOWanyfcd mofthe Tms%md.*ghandFm.slas,ine.go6m&Idbm ; KagbeVia eT.r�I�ra'tea deli�5ES � DasignererdCana�.r.Afro'_�ssstcuts�C�iDDueitt�p<adr.,e=�dgudNaB�e&+�3Ctsr{u�rd5atetytrtv;r�jSi,S;puh�hedtyTPtznd66DAarer{�nwdkrgEr�g�iEarGe.ir^fidw'+sihe�a��dd�cesdleTnr�sDes�'iaa:SpstFaYyErt�.1'�a�3F,v�k4rafa�m, afa�i�a" m1mdmiseddWbyaGsaWaped Warembgh agpafism .The Sp .1Eegswc :W*Da gMpetarTrmSysfffnE faa+f i ing.PDCoedtomsauras&ftAinIKi, aa!auae� Cm,* OCISA 1I .-.— .R,4T—. krt ,Fi?i.Es^ FEBRUARY 17, 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15 J DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30" 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36" 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42" 3169 4754 2900 4350 2451 3677 2511 3767 44 66 46` 3657 5485 3346 5019 2829 4243 2898 4347 s DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA: X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C • 10d NAILS NEAR SIDE +10d NAILS FAR SIDE FV� X' MIN �- 6' MIN THE LOCATION OF THE BREAK MUST BE GREATER THE REQUIRED X DIMENSION FROM ANY PERIMETER AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES.AT THE JOINTS OR SPLICES. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. S. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.' TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THAN OR EQUAL TO BREAK OR HEEL JOINT (SEE SKETCH ABOVE). 14 FEBRUARY 17, 2017 I SCAB APPLIED OVERHANGS I STDTL16 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 115 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED 6' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES