Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED, 520-1661991-KLAESEN-Eng Calcs-SignedTUFF SHED 2106-0425
Structural Calculations
for
Site: Gabriele Klaesen
4286 Christensen Road
Fort Pierce, FL 32966
Project: 16.0' x 28.0'
Shed
Inv. No. 1661991
Store: 520 - Orlando
8524 East Colonial Drive
Orlando, FL 32817
Engineer: Richard J. Wills, P.E.
Tuff Shed Inc.
1777 South Harrison St., Ste. 600
Denver, CO 80210
(303) 753-8833 ext. 96315
RWills@tuffshed.com
Date: May 25, 2021
This item has been digitally signed and sealed by
Richard Wills, PE. on the date adjacent to the seal
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
*: NO.76835
�,. STATE OF
25 MAY 2021
Page 1 of 9
TUFF SHER
DESIGN CRITERIA
Building Code: 2020 FBC (7th Ed.)
Seismic Design Category: A
Basic Wind Speed: 160 mph
Wind Exposure: C
Building Specifications
Width: 16.0 ft.
Length: 28.0 ft.
Side Wall Height: 6.69 ft.
Stud Size: 2x4
Stud Spacing: 16 in. o.c.
Wall Sheathing: 3/8" Smartside
Roof Sheathing: 7/16" OSB
Wall Wood Species & Grade: SPF Stud
Wall "A" Overhang:.0 in.
Wall "B" Overhang:.0 in.
Wall "C" Overhang:.0 in.
Wall "D" Overhang:.0 in.
Foundation: Concrete - Monolithic Foundation
Anchor: Titen HD Screw Anchor
Anchor Bolt Diameter:.5 in.
Trusses
Span: 16.0 ft.
Left Overhang:.0 in.
Right Overhang:.0 in.
Pitch: 5./12
Lumber: SPF #1/#2
Roofing:
Composition Shingles
Top Chord Live/Snow Load:
20 psf
Top Chord Dead Load:
10 psf
Bottom Chord Live Load:
30 psf
Bottom Chord Dead Load:
10 psf
Risk Category: II -Regular
Page 2 of 9
TUFF SHED
Page 3 of 9
Header: Loft Wall A, Hdr 1; Loft Wall C, Hdr. 1
Top Chord Live/Snow Load: 20 psf
Top Chord Dead Load: 10 psf
Bottom Chord Live Load: 0 psf
Bottom Chord Dead Load: 10 psf
Tributary Width= 1.50 ft.
Height of wall above Header= 1.50 ft.
Moment= 570 in: lbs.
Reaction= 84 lbs.
Header Size: 2x4
Header Size: 1%x3Y2 LVL
Number of Headers: 2
Number of Headers: 2
Header depth= 3.50 in.
Lumber
Header depth= 3.50 in.
Lumber
Total header width= 3.0 in.
SPF #11#2
Total header width= 3.50 in.
LVL 2600Fb
Header span= 2.25 ft.
Fb= 875 psi
Header span= 2.25 ft.
Fb= 2600 psi
F,= 450 psi
F,= 1555 psi
Bending
F,= 135 psi
Bending
F,= 285 psi
Sx 6.13 cu.in.
FOP= 425 psi
Se 7.15 cu.in.
FOP= 750 psi
F'b= 1636 psi
Ft, 1150 psi
OR
F'b= 3243 psi
Fc= 2510 psi
fb= 93 psi
E= 1,400,000 psi
V 80 psi
E= 1,900,000 psi
Em;n= 510,000 psi
Emn= 965,710 psi
Good/No Good? O.K.
Lumber
Factors
Good/No Good? O.K.
Lumber Factors
Co= 125
Duration
Cc= 1.25
Duration
Shear
CM= 1.00
Wet Service
Shear
CM= 1.00
Wet Service
F',= 169 psi
Ct= 1.00
Temperature
F',= 356 psi
Ci= 1.00
Temperature
fv= 12 psi
CL= 1.00
Beam Stability
f�= 10 psi
CL= 1.00
Beam Stability
Good/No Good? O.K.
CF= 1.50
Size
Good/No Good? O.K.
CF= 1.00
Size
Cfu= 1.00
Flat Use
Cfu= 1.00
Flat Use
Deflection
Ci= 1.00
Incising
Deflection
Ci= 1.00
Incising
E'= 1,400,000 psi
CV= 1.00
Repetitive Member
E'= 1,900,000 psi
C,= 1.00
Repetitive Member
1= 10.719
Cf= 1.00
Form
1= 12.505
C,= 1.00
Form
Deflection Ratio= L/180
TL (L/x) L/240
LL(Ux)
Deflection Ratio= 1-1180
TL(L/x) L/240
LL(Ux)
Allowable Deflection= .15 in.
.11 in.
Allowable Deflection= .15 in.
.15 in.
A= .0 in.
.0 in.
A= .0 in.
.0 in.
Good/No Good? O.K.
O.K.
Good/No Good? O.K.
O.K.
Header: Wall A, Hdr 1; Wall C, Hdr. 1
Top Chord Live/Snow Load: 20 psf
Top Chord Dead Load: 10 psf
Bottom Chord Live Load: 30 psf
Bottom Chord Dead Load: 10 psf
Tributary Width= 1.50 ft.
Height of wall above Header= 12.0 ft.
Moment= 3,565 in: lbs.
Reaction= 366lbs.
Header Size: 2x4
Header Size: 1%x3% LVL
Number of Headers: 2
Number of Headers: 2
Header depth= 3.50 in.
Lumber
Header depth= 3.50 in.
Lumber
Total header width= 3.0 in.
SPF #1/#2
Total header width= 3.50 in.
LVL 2600Fb
Headerspan= 3.25ft.
Fb= 875 psi
Header span= 3.25ft.
Fb= 2600 psi
F,= 450 psi
Ft= 1555 psi
Bending
F,= 135 psi
Bending
F,= 285 psi
Sx 6.13 cu.in.
F,= 425 psi
Sx 7.15 cu.in.
F,= 750 psi
F'b= 1634 psi
F�= 1150 psi
OR
F'b= 3240 psi
F�= 2510 psi
fb= 582 psi
E= 1,400,000 psi
fb= 499 psi
E= 1,900,000 psi
Emil 510,000 psi
Emig 965,710 psi
Good/NoGood? O.K.
Lumber
Factors
Good/No Good? O.K.
Lumber Factors
Co= 1.25
Duration
Cc= 1.25
Duration
Shear
CM= 1.00
Wet Service
Shear
CM= 1.00
Wet Service
F',= 169 psi
C,= 1.00
Temperature
F',= 356 psi
Ct= 1.00
Temperature
f,= 52 psi
CL= 1.00
Beam Stability
fv= 45 psi
CL= 1.00
Beam Stability
Good/No Good? O.K.
CF= 1.50
Size
Good/No Good? O.K.
CF= 1.00
Size
C,u= 1.00
Flat Use
Cfu= 1.00
Flat Use
Deflection
Q= 1.00
Incising
Deflection
Q= 1.00
Incising
E'= 1,400,000 psi
Cr= 1.00
Repetitive Member
E'= 1,900,000 psi
Cr= 1.00
Repetitive Member
1= 10.71875
Cf= 1.00
Form
1= 12.50520833
Cf= 1.00
Form
Deflection Ratio= L/180
TL (L/x) L/240
LL(Ux)
Deflection Ratio= U180
TL(L/x) L/240
LL(Ux)
Allowable Deflection= .22 in.
.16 in.
Allowable Deflection= .22 in.
.22 in.
A= .04 in.
.03 in.
A= .02 in.
.02 in.
Good/No Good? O.K.
O.K.
Good/No Good? O.K.
O.K.
TUFF SHED
Page 4 of 9
Header: Wall B, Hdrs. 1-2; Wall D, Hdr. 1
Top Chord Live/Snow Load: 20 psf
Top Chord Dead Load: 10 psf
Bottom Chord Live Load: 30 psf
Bottom Chord Dead Load: 10 psf
Tributary Width= 8.25 ft.
Height of wall above Header- 1.50 ft.
Moment= 9,387 in: Ibs.
Reaction= 963lbs.
Header Size: 2x4
Header Size: 1 %x3% LVL
Number of Headers: 2
Number of Headers: 2
Header depth= 3.50 in.
Lumber
Header depth= 3.50 in.
Lumber
Total header width= 3.0 in.
SPF #11#2
Total header width= 3.50 in.
LVL 2600Fb
Header span= 3.25 ft.
Fb= 875 psi
Header span= 3.25 ft.
Fb= 2600 psi
F,= 450 psi
F,= 1555 psi
Bending
F,= 135 psi
Bending
F,= 285 psi
Sx 6.13 cu.in.
FOP= 425 psi
Sx 7.15 cu.in.
FOP= 750 psi
F'b= 1634 psi
F�= 1150 psi
OR
F'b= 3240 psi
F�= 2510 psi
fb= 1533 psi
E= 1,400,000 psi
fb= 1314 psi
E= 1,900,000 psi
Emig 510,000 psi
Emig 965,710 psi
Good/NoGood? O.K.
Lumber
Factors
Good/No Good? O.K.
Lumber Factors
Co= 1.25
Duration
Cc= 1.25
Duration
Shear
CM= 1.00
Wet Service
Shear
CM= 1.00
Wet Service
F',= 169 psi
C,= 1.00
Temperature
F',= 356 psi
C,= 1.00
Temperature
fv= 138 psi
CL= 1.00
Beam Stability
f,= 118 psi
CL= 1.00
Beam Stability
Good/No Good? O.K.
CF= 1.50
Size
Good/No Good? O.K.
CF= 1.00
Size
C,u= 1.00
Flat Use
Cfu= 1.00
Flat Use
Deflection
Ci= 1.00
Incising
Deflection
Q= 1.00
Incising
E'= 1,400,000 psi
Cr= 1.00
Repetitive Member
E'= 1,900,000 psi
Cr= 1.00
Repetitive Member
1= 10.71875
Cf= 1.00
Form
1= 12.50520833
Cf= 1.00
Form
Deflection Ratio= L/180
TL (L/x) L/240
LL(Ux)
Deflection Ratio= U180
TL(L/x) L/240
LL(L/x)
Allowable Deflection= .22 in.
.16 in.
Allowable Deflection= .22 in.
.22 in.
♦1= .10 in.
.07 in.
A= .06 in.
.05 in.
Good/No Good? O.K.
O.K.
Good/No Good? O.K.
O.K.
Header: Wall B, Hdr 3
Top Chord Live/Snow Load: 20 psf
Top Chord Dead Load: 10 psf
Bottom Chord Live Load: 0 psf
Bottom Chord Dead Load: 10 psf
Tributary Width= 8.25 ft.
Height of wall above Header= .0 ft.
Moment= 20,914 in: Ibs.
Reaction= 1,073lbs.
Header Size: 2x4
Header Size: 1%x3Y2 LVL
Number of Headers: 2
Number of Headers: 3
Header depth= 3.50 in.
Lumber
Header depth= 3.50 in.
Lumber
Total header width= 3.0 in.
SPF #11#2
Total header width= 5.25 in.
LVL 2600Fb
Header span= 6.50 ft.
Fb= 875 psi
Header span= 6.50 ft.
Fb= 2600 psi
F,= 450 psi
F,= 1555 psi
Bending
F,= 135 psi
Bending
F,= 285 psi
Sx 6.13 cu.in.
FOP= 425 psi
Sx 10.72 cu.in.
FOP= 750 psi
F'b= 1627 psi
F�= 1150 psi
OR
F'b= 3242 psi
F�= 2510 psi
fb= 3414 psi
E= 1,400,000 psi
V 1951 psi
E= 1,900,000 psi
Emil 510,000 psi
Emig 965,710 psi
Good/No Good? N.G.
Lumber
Factors
Good/No Good? O.K.
Lumber Factors
Co= 1.25
Duration
Cc= 1.25
Duration
Shear
CM= 1.00
Wet Service
Shear
CM= 1.00
Wet Service
F',= 169 psi
C,= 1.00
Temperature
F',= 356 psi
C,= 1.00
Temperature
f,= 153 psi
Ci= 0.99
Beam Stability
f,= 88 psi
CL= 1.00
Beam Stability
Good/No Good? O.K.
CF= 1.50
Size
Good/No Good? O.K.
CF= 1.00
Size
C,u= 1.00
Flat Use
C,u= 1.00
Flat Use
Deflection
Q= 1.00
Incising
Deflection
Q= 1.00
Incising
E'= 1,400,000 psi
Cr= 1.00
Repetitive Member
E'= 1,900,000 psi
Cr= 1.00
Repetitive Member
1= 10.71875
Cf= 1.00
Form
1= 18.7578125
Cf= 1.00
Form
Deflection Ratio= L/180
TL (Ux) L/240
LL(Ux)
Deflection Ratio= U180
TL(L/x) L/240
LL(Ux)
Allowable Deflection= .43 in.
.33 in.
Allowable Deflection= .43 in.
.43 in.
A= .88 in.
.44 in.
A= .37 in.
.19 in.
Good/No Good? N.G.
N.G.
Good/No Good? O.K.
O.K.
®TUFF SHED
Trimmer for: Header: Loft Wall A, Hdr 1; Loft Wall C, Hdr. 1
SPF Stud
Fe= 675 psi
Load= 84 lbs.
F,= 350 psi
width= 3.50 in.
Fe 135 psi
thickness= 1.50 in.
FIp= 425 psi
No. of members= 1
FI= 725 psi
Unbraced Length(x)(width)= 90.0 in.
E= 440,000 psi
Unbraced Length(y)(thickness)= 6.0 in.
Effective Length factor, Kelxl= 1
Effective Length factor, Kllyl= 1
c= 0.8
A= 5.25 sq.in.
(1/d)x 25.71
(1/d)y= 4.00
E'-= 440,000 psi
Weak Axis Calculations(y)
FIE= 22605.00
F*I= 951.56
FIE/F*I= 23.76
1+FIE/F*I/2c= 15.47
Cp= 0.99
F'I= 943.35
Pei;o.*,ab;e 4,953 lbs.
Good/No Good? O.K.
Lumber Factors
Cc= 1.25
Duration
CM= 1.00
Wet Service
q= 1.00
Temperature
CL= 1.00
Beam Stability
Cr= 1.05
Size
Cw= 1.00
Flat Use
C;= 1.00
Incising
C,= 1.00
Repetitive Member
Cp 1.00
Form
CT= 1.00
Buckling Stiffness
Strong Axis Calculations (x)
FIE= 546.99
F*I= 951.56
FIE/F*I= 0.57
1+FIE/F*I/2c= 0.98
Cp= 0.48
F'I= 460.58
Pauo.*,ae;e 2,418 lbs.
Good/No Good? O.K.
Trimmer for: Header: Wall B, Hdrs. 1-2; Wall D, Hdr. 1
SPF Stud
Fe= 675 psi
Load= 963 lbs.
F,= 350 psi
width= 3.50 in.
Fe 135 psi
thickness= 1.50 in.
FIp= 425 psi
No. of members= 1
FI= 725 psi
Unbraced Length(x)(width)= 90.0 in.
Em;n= 440,000 psi
Unbraced Length(y)(thickness)= 6.0 in.
Effective Length factor, KI(x)= 1
Effective Length factor, Kliyl= 1
c= 0.8
A= 5.25 sq.in.
(1/d)x 25.71
(1/d)y= 4.00
E'm;n= 440,000 psi
Weak Axis Calculations(y)
FIE= 22605.00
F*I= 951.56
FIE/F*I= 23.76
1+FIE/F*I/2c= 15.47
Cp= 0.99
F'I= 943.35
Pe1;-1, 4,953 lbs.
Good/No Good? O.K.
Lumber Factors
Cc= 1.25
Duration
CM= 1.00
Wet Service
q= 1.00
Temperature
CL= 1.00
Beam Stability
Cr= 1.05
Size
Cw= 1.00
Flat Use
C;= 1.00
Incising
C,= 1.00
Repetitive Member
Cr= 1.00
Form
CT= 1.00
Buckling Stiffness
Strong Axis Calculations (x)
FIE= 546.99
F*,= 951.56
FIE/F'I= 0.57
1+FIE/F*I/2c= 0.98
Cp= 0.48
F'I= 460.58
P111-bie- 2,418 lbs.
Good/No Good? O.K.
Trimmer for: Header:
Wag A, Hdr 1; Wan C, Hdr. 1
SPF Stud
Fe= 675 psi
Load= 366 lbs.
Ft= 350 psi
width= 3.50 in.
Fe 135 psi
thickness= 1.50 in.
FIp= 425 psi
No. of members= 1
FI= 725 psi
Unbraced Length(x)(width)= 90.0 in.
E-= 440,000 psi
Unbraced Length(y)(thickness)= 6.0 in.
Effective Length factor, Kelxl= 1
Effective Length factor, Kllyl= 1
c= 0.8
A= 5.25 sq.in.
(1/d)x 25.71
(1/d)y= 4.00
E'-= 440,000 psi
Weak Axis Calculations(y)
FIE= 22605.00
F*I= 951.56
FIE/F*,= 23.76
1+FIE/F*I/2c= 15.47
Cp= 0.99
F'I= 943.35
Pei;o.*,ab;e 4,953 lbs.
Lumber Factors
Cc= 1.25
Duration
CM= 1.00
Wet Service
q= 1.00
Temperature
CL= 1.00
Beam Stability
Cr= 1.05
Size
C�= 1.00
Flat Use
C;= 1.00
Incising
C,= 1.00
Repetitive Member
Cr= 1.00
Form
CT= 1.00
Buckling Stiffness
Strong Axis Calculations (x)
FIE= 546.99
F*I= 951.56
FIE/F*,= 0.57
1+FIE/F*I/2c= 0.98
Cp= 0.48
F'I= 460.58
P111-1,= 2,418 lbs.
Good/No Good? O.K. Good/No Good? O.K.
Trimmer for: Header: Wall B, Hdr 3
Load= 1,073 lbs.
width= 3.50 in.
thickness= 1.50 in.
No. of members= 2
Unbraced Length(x)(width)= 90.0 in.
Unbraced Length(y)(thickness)= 6.0 in.
Effective Length factor, KI(x)= 1
Effective Length factor, Keiyl= 1
c= 0.8
A= 10.50 sq.in.
(1/d)x 25.71
(1/d)y= 2.00
E'_= 440,000 psi
Weak Axis Calculations(y)
FIE= 90420.00
F*,= 951.56
FIEF*I= 95.02
1+FIE/F*I/2c= 60.01
Cp= 1.00
F'I= 949.55
Pe11-0 9,970 lbs.
Good/No Good? O.K.
SPF Stud
Fb= 675 psi
F 350 psi
Fe 135 psi
FIp= 425 psi
Fe 725 psi
E= 440,000 psi
Lumber Factors
Cc= 1.25
Duration
CM= 1.00
Wet Service
q= 1.00
Temperature
CL= 1.00
Beam Stability
Cr= 1.05
Size
Cw= 1.00
Flat Use
C;= 1.00
Incising
C,= 1.00
Repetitive Member
Cr= 1.00
Form
CT= 1.00
Buckling Stiffness
Strong Axis Calculations (x)
FIE= 546.99
F*,= 951.56
FIE/F*I= 0.57
1+FIE/F*I/2c= 0.98
Cp= 0.48
F'I= 460.58
PO -I 4,836 lbs.
Good/No Good? O.K.
nht TUFF SHED'
Page 6 of 9
Wind Calculations (C&C)
Alternate all -heights method
Wind Speed, VASD: 124 mph
Wind Exposure: C
Risk Category: II -Regular
Roof Angle= 22.62
Gable Wall Span= 16.0 ft.
Longitude Wall Span= 28.0 ft.
Enclosure Classification: Enclosed
Section 26.10
Kzt= 1
Section 26.8.2
K 0.85
Table 27.3-1
Kd= 0.85
Table 26.6-1
Mean Roof Height= 10.02 ft.
LOW RISE BUILDINGS (ASCE 7-16 Chapt. 30)
GCpi= 0.18
qh= 28.41 psf
Zone 1
Zone 2 Zone 3 Zone 4
Zone 5
GCP -0.9
-1.7 -2.6 -1.1
-1.4 (ASCE 7-16 Figures 30.3-1,30.3-2B,30.3-2a,30.3-2C)
GCP 0.5
0.5 0.5 1.0
1.0 (ASCE 7-16 Figures 30.3-1,30.3-2B,30.3-2a,30.3-2C)
p= -30.68 psf
-53.41 psf -78.98 psf -36.36 psf
-44.89 psf
p= 19.32 psf
19.32 psf 19.32 psf 33.52 psf
33.52 psf
p= -30.68 psf
-53.41 psf -78.98 psf -36.36 psf
-44.89 psf
p= 19.32 psf
19.32 psf 19.32 psf 33.52 psf
33.52 psf
Pmax= 19 psf
19 psf 19 psf 34 psf
34 psf
Pmin= -31 psf
-53 psf -79 psf -36 psf
-45 psf
OTUFF SHED Page 7 of
Wind Calculations (MWFRS)
ASCE 7-16 Chapt. 28 Part 1
Wind Speed, vAM: 124 mph
Wind Speed, vu,: 160 mph
Wind Exposure: C
Risk Category: II -Regular
Roof Angle= 22.62
Gable Wall Span= 16.0 ft.
Longitude Wall Span= 28.0 ft.
Mean Roof Height= 14.19 ft.
Enclosure Classification: Enclosed
Section 26.10
K,,= 1
Section 26.8.2
K,= 0.85
Table 27.3-1
Ka= 0.85
Table 26.6-1
GCo,= t0.18
Table 26.11-1
qh= 47.35 psf
Eq. 28.3-1
s
1
2
3
4
5
6
1E
2E
3E
4E
5E
6E
Load Case A
0.54
-0.45
-0.47
-0.41
N/A
N/A
0.77
-0.72
-0.65
-0.60
N/A
N/A
Load Case B
-0.45
-0.69
-0.37
-0.45
0.40
-0.29
-0.48
-1.07
-0.53
-0.48
0.61
-0.43
Load Case A (-GCpi)
16.94 psf
-30.03 psf
-30.63 psf
-28.14 psf
N/A
N/A
27.99 psf
-42.56 psf
-39.21 psf
-36.84 psf
N/A
N/A
Load Case A (+GCP;)
33.99 psf
-12.98 psf
-13.58 psf
-11.09 psf
N/A
N/A
45.04 psf
-25.52 psf
-22.16 psf
-19.80 psf
N/A
N/A
n
Load Case B (-GCpi)
-29.83 psf
-41.19 psf
-26.04 psf
-29.83 psf
10.42 psf
-22.25 psf
-31.25 psf
-59.19 psf
-33.62 psf
-31.25 psf
20.36 psf
-28.88 psf
Load Case B (+GCP)
-12.78 psf
-24.15 psf
-9.0 psf
-12.78 psf
27.46 psf
-5.21 psf
-14.20 psf
-42.14 psf
-16.57 psf
-14.20 psf
37.41 psf
-11.84 psf
max. pL= 45.04 psf
Side Wall, maximum wind pressure
max. pT= 37.41 psf
Gable End Wall, maximum wind pressure
Max. p,-'� -59.19 psf
VL= 4,246 lbs.
Max. Longitudinal Shear
VT= 8,946 lbs.
Max. Transversial Shear
Max. uplift pressure=-26,516 lbs.
Max. uplift pressure on the building due to wind on roof
Diaphragm Calculations
Length (for shear)
Wall A: 13.0 ft.
Wall B: 16.0 ft.
Wall C: 13.0 ft.
Wall D: 25.0 ft.
Edge Boundary
HF/SPF
Sheathing*
Nail Size Nailing Nailing
v
Factor
Roof 7/16" OSB
8d 6 in. o.c. 12 in. o.c. v= 180.0 plf
165.6 plf
0.92
Wall 3/8" Smartside
8d 6 in. o.c. 12 in. o.c. v= 200.0 plf
164.0 plf
0.82
Wall 3/8" Smartside
8d 4 in. o.c. 12 in. o.c. v= 300.0 plf
246.0 plf
0.82
'Must be Rated sheathing
Wind
vaoow
2bdh edge nailing
Wall A: 412.9 plf
Sheathe Both Faces of Wall
492.0 plf
Co= 1.00 1.00 6" o.c.
Wall B: 159.2 plf
181.4 plf
Co= 0.74 1.00 4" o.c.
Wall C: 412.9 plf
Sheathe Both Faces of Wall
492.0 plf
Co= 1.00 1.00 6" o.c.
Wall D: 101.9 plf
164.0 plf
Co= 1.00 1.00 6" o.c.
Roof= 91.0 plf
165.6 plf
OTUFFSHED
Page 8 of 9
Foundation Calculations
Fe= 1500 psf
Min. allowable bearing pressure
Foundation Stem above grade= 6.0 in.
Height of foundation from the top of the grade to the top of the foundation/stemwall
Foundation Depth= 12.0 in.
Depth of the foundation from the top of the grade to the bottom of the footing
Pmax 626.9 plf
Max. load per foot of wall
bftg= 5.02 in.
min. required footing width
PLm„r 1,073 lbs.
Maximum point load
brtg= 102.96 sq.in.
Min. required footing area
Rectangular pad= 2.86 in.
min. required footing width
Overturning Calculations
Wall A
Wall B
Min. No. anchor bolts= 2
Min. No. anchor bolts= 3
Width= 13.0ft.
Width= 16.0ft.
Height= 6.69 ft.
Height= 6.69 ft.
Pw;nd= 8,946 lbs.
Pw;nd= 4,246lbs.
Wall Weight= 533.63 lbs.
Wall Weight= 738.0 lbs.
Upliff,,,;,,d= 2,494.31 Ibs.
UPlift,,;nd= 695.72 lbs.
Allowable Service, wind: 7.68 N.G. Holddowns required.
Allowable Service, wind: 1.05 N.G. Holddowns required.
Wall C
Wall D
Min. No. anchor bolts= 2
Min. No. anchor bolts= 4
Width= 13.0ft.
Width= 25.0ft.
Height= 6.69 ft.
Height= 6.69 ft.
Pw;nd= 8,946 lbs.
Pw;nd= 4,246lbs.
Wall Weight= 533.63lbs.
Wall Weight= 1,099.13lbs.
UPliffw;nd= 2,494.31 lbs.
UPliftw;nd= 131.86 lbs.
Allowable Service, wind: 7.68 N.G. Holddowns required.
Allowable Service, wind: 0.47 ok. No additional holddowns required.
Building Uplift
Wind uplift=-26,515.87 lbs.
Min. building weight= 7,141.50 lbs.
Additional min. dead load= .0 lbs. additional dead load due to steel floor, wood base, or other permanent loads,if any, (not including foundation)
Net uplift=-19,374.37 lbs.
Total no. of anchor bolts (min.)= 11 (Does not include additional holddowns for overturning of the walls.)
Anchor bolt uplift= 15,070.0 lbs.
Additional anchors reauired
nht TUFF SHER
Page 9 of 9
Axial Load
Stud Spacing= 16 in. o.c.
Max. Load on wall= 626.9 plf
depth= 3.50 in.
width= 1.50 in.
No. of members= 1
Length (depth)= 75.75 in.
Length (width)= 12.0 in.
Kew= 2
Ke(y)= 2
KBE= 0.3
c= 0.8
Load= 836 lbs.
A= 5.25 sq.in.
(1/d)x 43.29
(I/d) = 16.00
Emin= 440,000 psi
Bearing Wall Calculations
unbraced length (depth)(x)(in.)
unbraced length (width)(y)(in.)
effective length factor (x)
effective length factor (y)
Load per stud
Weak Axis Calculations(y)
F,E= 1412.81
F*c= 951.56
FEE/F*c= 1.48
1+FEE/F*j2c= 1.55
Cp= 0.81
F'c= 768.35
Paiiowabie= 4,034 lbs.
Good/No Good? O.K.
Wind Load
Wind load per stud= 60.1 plf
Moment= 3,589 in.-Ibs.
Reaction= 190lbs.
Header depth= 3.50 in.
Total header width= 1.50 in.
Header span= 8.0 ft.
Bending
Sx 3.06 cu.in.
F'b= 1782 psi
fb= 1172 psi
Good/No Good? O.K.
Shear
F'=216psi
f"= 54 psi
Good/No Good? O.K.
Lumber
SPF Stud
Fb= 675 psi
Ff= 350 psi
F 135 psi
FOP= 425 psi
F,= 725 psi
Emin= 440,000 psi
E= 1,200,000 psi
Lumber Factors
Co= 1.25
Duration for gravity load
CM= 1.00
Wet Service
Cf= 1.00
Temperature
CL= 1.00
Beam Stability
CF= 1.05
Size for F.
Cf = 1.00
Flat Use
Cj= 1.00
Incising
C 1.15
Repetitive Member
Cf= 1.00
Form
CT= 1.00
Buckling Stiffness (NDS 4.4.2)
CF= 1.10
Size for Fb
Cc= 1.60
Duration for lateral load
Cr= 1.50
Repetitive Member (wind)
Strong Axis Calculations
(x)
F,E= 193.03
F*�= 951.56
FEE/F*= 0.20
1+FEE/F*c/2c= 0.75
CF= 0.19
F'�= 184.19
Paiiowabie= 967 lbs.
Good/No Good? O.K.
Combined Bending and Axial Loading
F'c= 235.77 combine allowable compressive stress
f,= 45 psi combine compressive stress
Combined stress index= 0.90
Good/No Good? O.K.