HomeMy WebLinkAboutAPPROVED FL6393.9 iYl a`2 —
Professional . , � d
r�
BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications I Contact Us BCIS Site Map Links Search
bpr
Product Approval USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL6393-R14
SECRETARY
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived O
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood,SC 29648
(864) 377-0691
Mike.rhoden@velux.com
Authorized Signature Mike Rhoden
Mike.rhoden@velux.com
Technical Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Dr
Fort Mill,SC 29708
(864) 377-0691
mike.rhoden@velux.com
Quality Assurance Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Drive
Fort Mill, SC 29708
(803) 396-5736
mike.rhoden@velux.com
Category ESkyhtsSubcategory
Compliance Method Certification Mark or Listing
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA 101/I.S.2/A440 2011
ASTM E1886 2012
ASTM E1996 2012
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL6393 R14 Equiv FL 6393 ASTM EQ,pdf
Product Approval Method Method 1 Option A
Date Submitted 09/25/2020
Date Validated 11/16/2020
Date Pending FBC Approval
Date Approved 11/20/2020
Date Revised 04/29/2021
Summary of Products
FL# Model,Number or Name Description
6393.1 VELUX Flat Glass Sun Tunnel (Non- [TZR or TZRL] + [014] + [2A00] 3mm tempered LowE366
Impact) outer pane with 7mm diamond wire inner pane.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-701.00 01 02.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 05/05/2021
Design Pressure: +100/-140 Installation Instructions
Other: SKG-PG100; Max tube dia. 356 mm (14 in). PG100 FL6393 R14 II TZR-TZRL Installation.pdff
means minimum capacity is 100 psf. Glazing assembly is 3mm Verified By: Window and Door Manufacturer Association
tempered LowE366 outer pane with 7mm diamond wire inner Created by Independent Third Party:
pane.Anchorage fasteners provided to secure skylight to curb : Evaluation Reports
#8 1 3/4"(4.2 x 45mm) pan head st. st. metal screws Created by Independent Third Party:
6393.2 VELUX Sun Tunnel TSR 0000 TSR 010 size(426-H-626.07)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-626.07.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 04/03/2027
Design Pressure: +200/-180 Installation Instructions
Other:TDDCC-PG180; Size tested 254 mm dia (10 in). PG180 FL6393 R14 II TSR 010 Installation.pdf
means minimum capacity is 180 psf. Dome glazing is minimum Verified By: Window and Door Manufacturer Association
3mm thick. Flashing nails directly to roof deck.Anchorage Created by Independent Third Party:
fasteners provided are 10 ga. galv. ring shank nails. Evaluation Reports
Created by Independent Third Party:
6393.3 VELUX Sun Tunnel (14"Commercial) [TCC 014 or TGC 014 or TMC 014] + [1000] with diffuser:
Impact Resistant [THC 014 or TOC 014 or TTC 014] + [000*]//With or without
an Energy Kit(*denotes 0, 2 or 3) (426-H-707.03)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-707.00.pdf
Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-707.03.pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +50/-50 11/29/2021
Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions
max. dia. 356 mm (14 in).These models were tested for FL6393 R14 II TCC Installation.pdf
impact and cycling pursuant to ASTM standards. Dome glazing FL6393 R14 II TGC TMC Installation.pdf
is minimum 3 mm thick. Flashing types attach either to site- FL6393 R14 II THC Diffuser Installation.pdf
built curb or directly to roof deck.Anchorage fasteners provided FL6393 R14 II TOC Diffuser Installation.pdf
are black#8 st. stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
6393.4 VELUX Sun Tunnel (14"Commercial) [TCC 014 or TGC 014 or TMC 014] + [0000 or 1000] with
Non-Impact diffuser: [THC 014 or TOC 014 or TTC 014] + [000*]//With or
without an Energy Kit(*denotes 0, 2 or 3) (426-H-707.00)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-707.00.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 12/14/2021
Design Pressure: +300/-145 Installation Instructions
Other:TDDCC/TDDCC-PG145; Max. dia. 356 mm (14 in). FL6393 R14 II TCC Installation.pdf
PG145 means minimum capacity is 145 psf. Dome glazing is FL6393 R14 II TGC TMC Installation.pdf
minimum 3 mm thick. Flashing types attach either to site-built FL6393 R14 II THC Diffuser Installation.pdf
curb or directly to roof deck.Anchorage fasteners provided are FL6393 R14 II TOC Diffuser Installation.pdf
black#8 st.stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
6393.5 VELUX Sun Tunnel (22"Commercial) [TCC 022 or TGC 022] + [5000] with diffuser: [THC 022 or TOC
Impact Resistant 022 or TTC 022] + [000*]//With or without an Energy Kit(*
denotes 0,2 or 3) (426-H-708.03)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-708.00.pdf
Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-708.03.pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +50/-50 12/20/2021
Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions
max. dia. 559 mm (22 in).These models were tested for FL6393 R14 II TCC Installation.pdf
impact and cycling pursuant to ASTM standards. Dome glazing FL6393 R14 II TGC TMC Installation.pdf
is minimum 3 mm thick. Flashing types attach either to site- FL6393 R14 II THC Diffuser Installation.pdf
built curb or directly to roof deck.Anchorage fasteners provided FL6393 R14 II TOC Diffuser Installation.pdf
are black#8 st. stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
6393.6 VELUX Sun Tunnel (22"Commercial) [TCC 022 or TGC 022] + [3000 or 5000] with diffuser: [THC
Non-Impact 022 or TOC 022 or TTC 022] + [000*]//With or without an
Energy Kit(*denotes 0,2 or 3) (426-H-708.00)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-708.00.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 12/20/2021
Design Pressure: +300/-130 Installation Instructions
Other:TDDCC/TDDOC-PG130; Max. dia. 559 mm (22 in). FL6393 R14 II TCC Installation.pdf
PG130 means minimum capacity is 130 psf. Dome glazing is FL6393 R14 II TGC TMC Installation.pdf
minimum 3 mm thick. Flashing types attach either to site-built FL6393 R14 II THC Diffuser Installation.pdf
curb or directly to roof deck.Anchorage fasteners provided are FL6393 R14 II TOC Diffuser Installation.pdf
black#8 st.stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf
Verified By: Window and Door Manufacturer Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
6393.7 VELUX Sun Tunnel (Residential Curb TCR 014 + [1000US or 1000USEO] (426-H-706.03)
Mount)Impact Resistant
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-706.00.pdf
Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-706.03.pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +50/-50 10/30/2021
Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions
max. dia. 356 mm (14 in).This model was tested for impact FL6393 R14 II TCR 014 Installation.pdf
and cycling pursuant to ASTM standards. Dome glazing is Verified By: Window and Door Manufacturer Association
minimum 3 mm thick. Flashing attaches to site-built curb. Created by Independent Third Party:
Anchorage fasteners provided are black#8 st. stl. pan head Evaluation Reports
screws. Created by Independent Third Party:
6393.8 VELUX Sun Tunnel (Residential Curb TCR 014+ [OOOOUS, OOOOUSEO,OOOOUSEI, 1000US or
Mount) Non-Impact 1000USEO] (426-H-706.00)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-706.00.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 11/21/2021
Design Pressure: +300/-165 Installation Instructions
Other:TDDCC-PG165; Dia. 356 mm (14 in.) PG165 means FL6393 R14 II TCR 014 Installation.pdf
minimum capacity is 165 psf. Flashing attaches to site-built Verified By: Window and Door Manufacturer Association
curb with eight supplied screws,two per side. Dome glazing is Created by Independent Third Party:
minimum 3mm thick. Evaluation Reports
Created by Independent Third Party:
MMWAM
6393.9 VELUX Sun Tunnel (Residential) [TGR,TMF or TMR] + [010 or 014] + [1000 or 1000EO] -and-
j �Impact Resistant [TGF 014 or TGF 022] + [1000 or 1000EO] (426-H-705.03)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-705.00.pdf
Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-705.03.pdf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +50/-50 11/29/2021
Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions
max. dia. 559 mm (22 in.).These models were tested for FL6393 R14 II TGF 022 Installation.pdf
impact and cycling pursuant to ASTM standards. Dome glazing FL6393 R14 II TGF TMF 014 Installation.pdf
is minimum 3 mm thick. Flashing types attach to roof deck. FL6393 R14 II TGR TMR THR 014 Installation.pdf
Anchorage fasteners provided are black#8 st. stl. pan head Verified By: Window and Door Manufacturer Association
screws. Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
r
6393.10 VELUX Sun Tunnel (Residential) Non- [TGF,TGR,TMF or TMR] + [010 or 014] + [0000, OOOOEO or
Impact E1, 1000 or 1000EO] -and -TGF+ [014 or 022] + [0000,
OOOOEO or E1, 1000 or 1000EO] (426-H-705.00)