Loading...
HomeMy WebLinkAboutAPPROVED FL6393.9 iYl a`2 — Professional . , � d r� BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications I Contact Us BCIS Site Map Links Search bpr Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL6393-R14 SECRETARY Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived O Product Manufacturer Velux America, LLC Address/Phone/Email P.O. Box 5001 Greenwood,SC 29648 (864) 377-0691 Mike.rhoden@velux.com Authorized Signature Mike Rhoden Mike.rhoden@velux.com Technical Representative Mike Rhoden Address/Phone/Email 104 Ben Casey Dr Fort Mill,SC 29708 (864) 377-0691 mike.rhoden@velux.com Quality Assurance Representative Mike Rhoden Address/Phone/Email 104 Ben Casey Drive Fort Mill, SC 29708 (803) 396-5736 mike.rhoden@velux.com Category ESkyhtsSubcategory Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturer Association Validated By Window and Door Manufacturers Association Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA 101/I.S.2/A440 2011 ASTM E1886 2012 ASTM E1996 2012 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL6393 R14 Equiv FL 6393 ASTM EQ,pdf Product Approval Method Method 1 Option A Date Submitted 09/25/2020 Date Validated 11/16/2020 Date Pending FBC Approval Date Approved 11/20/2020 Date Revised 04/29/2021 Summary of Products FL# Model,Number or Name Description 6393.1 VELUX Flat Glass Sun Tunnel (Non- [TZR or TZRL] + [014] + [2A00] 3mm tempered LowE366 Impact) outer pane with 7mm diamond wire inner pane. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-701.00 01 02.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/05/2021 Design Pressure: +100/-140 Installation Instructions Other: SKG-PG100; Max tube dia. 356 mm (14 in). PG100 FL6393 R14 II TZR-TZRL Installation.pdff means minimum capacity is 100 psf. Glazing assembly is 3mm Verified By: Window and Door Manufacturer Association tempered LowE366 outer pane with 7mm diamond wire inner Created by Independent Third Party: pane.Anchorage fasteners provided to secure skylight to curb : Evaluation Reports #8 1 3/4"(4.2 x 45mm) pan head st. st. metal screws Created by Independent Third Party: 6393.2 VELUX Sun Tunnel TSR 0000 TSR 010 size(426-H-626.07) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-626.07.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/03/2027 Design Pressure: +200/-180 Installation Instructions Other:TDDCC-PG180; Size tested 254 mm dia (10 in). PG180 FL6393 R14 II TSR 010 Installation.pdf means minimum capacity is 180 psf. Dome glazing is minimum Verified By: Window and Door Manufacturer Association 3mm thick. Flashing nails directly to roof deck.Anchorage Created by Independent Third Party: fasteners provided are 10 ga. galv. ring shank nails. Evaluation Reports Created by Independent Third Party: 6393.3 VELUX Sun Tunnel (14"Commercial) [TCC 014 or TGC 014 or TMC 014] + [1000] with diffuser: Impact Resistant [THC 014 or TOC 014 or TTC 014] + [000*]//With or without an Energy Kit(*denotes 0, 2 or 3) (426-H-707.03) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-707.00.pdf Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-707.03.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 11/29/2021 Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions max. dia. 356 mm (14 in).These models were tested for FL6393 R14 II TCC Installation.pdf impact and cycling pursuant to ASTM standards. Dome glazing FL6393 R14 II TGC TMC Installation.pdf is minimum 3 mm thick. Flashing types attach either to site- FL6393 R14 II THC Diffuser Installation.pdf built curb or directly to roof deck.Anchorage fasteners provided FL6393 R14 II TOC Diffuser Installation.pdf are black#8 st. stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 6393.4 VELUX Sun Tunnel (14"Commercial) [TCC 014 or TGC 014 or TMC 014] + [0000 or 1000] with Non-Impact diffuser: [THC 014 or TOC 014 or TTC 014] + [000*]//With or without an Energy Kit(*denotes 0, 2 or 3) (426-H-707.00) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-707.00.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/14/2021 Design Pressure: +300/-145 Installation Instructions Other:TDDCC/TDDCC-PG145; Max. dia. 356 mm (14 in). FL6393 R14 II TCC Installation.pdf PG145 means minimum capacity is 145 psf. Dome glazing is FL6393 R14 II TGC TMC Installation.pdf minimum 3 mm thick. Flashing types attach either to site-built FL6393 R14 II THC Diffuser Installation.pdf curb or directly to roof deck.Anchorage fasteners provided are FL6393 R14 II TOC Diffuser Installation.pdf black#8 st.stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 6393.5 VELUX Sun Tunnel (22"Commercial) [TCC 022 or TGC 022] + [5000] with diffuser: [THC 022 or TOC Impact Resistant 022 or TTC 022] + [000*]//With or without an Energy Kit(* denotes 0,2 or 3) (426-H-708.03) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-708.00.pdf Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-708.03.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 12/20/2021 Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions max. dia. 559 mm (22 in).These models were tested for FL6393 R14 II TCC Installation.pdf impact and cycling pursuant to ASTM standards. Dome glazing FL6393 R14 II TGC TMC Installation.pdf is minimum 3 mm thick. Flashing types attach either to site- FL6393 R14 II THC Diffuser Installation.pdf built curb or directly to roof deck.Anchorage fasteners provided FL6393 R14 II TOC Diffuser Installation.pdf are black#8 st. stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 6393.6 VELUX Sun Tunnel (22"Commercial) [TCC 022 or TGC 022] + [3000 or 5000] with diffuser: [THC Non-Impact 022 or TOC 022 or TTC 022] + [000*]//With or without an Energy Kit(*denotes 0,2 or 3) (426-H-708.00) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-708.00.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/20/2021 Design Pressure: +300/-130 Installation Instructions Other:TDDCC/TDDOC-PG130; Max. dia. 559 mm (22 in). FL6393 R14 II TCC Installation.pdf PG130 means minimum capacity is 130 psf. Dome glazing is FL6393 R14 II TGC TMC Installation.pdf minimum 3 mm thick. Flashing types attach either to site-built FL6393 R14 II THC Diffuser Installation.pdf curb or directly to roof deck.Anchorage fasteners provided are FL6393 R14 II TOC Diffuser Installation.pdf black#8 st.stl. pan head screws. FL6393 R14 II TTC Diffuser Installation.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 6393.7 VELUX Sun Tunnel (Residential Curb TCR 014 + [1000US or 1000USEO] (426-H-706.03) Mount)Impact Resistant Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-706.00.pdf Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-706.03.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 10/30/2021 Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions max. dia. 356 mm (14 in).This model was tested for impact FL6393 R14 II TCR 014 Installation.pdf and cycling pursuant to ASTM standards. Dome glazing is Verified By: Window and Door Manufacturer Association minimum 3 mm thick. Flashing attaches to site-built curb. Created by Independent Third Party: Anchorage fasteners provided are black#8 st. stl. pan head Evaluation Reports screws. Created by Independent Third Party: 6393.8 VELUX Sun Tunnel (Residential Curb TCR 014+ [OOOOUS, OOOOUSEO,OOOOUSEI, 1000US or Mount) Non-Impact 1000USEO] (426-H-706.00) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-706.00.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 11/21/2021 Design Pressure: +300/-165 Installation Instructions Other:TDDCC-PG165; Dia. 356 mm (14 in.) PG165 means FL6393 R14 II TCR 014 Installation.pdf minimum capacity is 165 psf. Flashing attaches to site-built Verified By: Window and Door Manufacturer Association curb with eight supplied screws,two per side. Dome glazing is Created by Independent Third Party: minimum 3mm thick. Evaluation Reports Created by Independent Third Party: MMWAM 6393.9 VELUX Sun Tunnel (Residential) [TGR,TMF or TMR] + [010 or 014] + [1000 or 1000EO] -and- j �Impact Resistant [TGF 014 or TGF 022] + [1000 or 1000EO] (426-H-705.03) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL6393 R14 C CAC 426-H-705.00.pdf Approved for use outside HVHZ:Yes FL6393 R14 C CAC 426-H-705.03.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 11/29/2021 Other: Wind Zone 3, Missile Level C,Cycle Pressure+50/-50, Installation Instructions max. dia. 559 mm (22 in.).These models were tested for FL6393 R14 II TGF 022 Installation.pdf impact and cycling pursuant to ASTM standards. Dome glazing FL6393 R14 II TGF TMF 014 Installation.pdf is minimum 3 mm thick. Flashing types attach to roof deck. FL6393 R14 II TGR TMR THR 014 Installation.pdf Anchorage fasteners provided are black#8 st. stl. pan head Verified By: Window and Door Manufacturer Association screws. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: r 6393.10 VELUX Sun Tunnel (Residential) Non- [TGF,TGR,TMF or TMR] + [010 or 014] + [0000, OOOOEO or Impact E1, 1000 or 1000EO] -and -TGF+ [014 or 022] + [0000, OOOOEO or E1, 1000 or 1000EO] (426-H-705.00)