Loading...
HomeMy WebLinkAboutProduct Approval AN bin BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BC1 Site Map Links Search dbpr ,-j Product Approval File Copy USER:Public User kEVWED'07-03� Product Approval Menu>Product or Application Search>Application List>Application Detail a 6 /'1 si FL# FL27499-R4 CODE COMPLIANCE v k Application Type Revision Code Version 2020 ST. CIE COUNTY TBOCC��/-,>/ Application Status Approved Comments Archived Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772) 872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A.Turner,P.E.,MBA Validation Checklist-Hardcopy Received Certificate of Independence FL27499 R4 COI Dyn COI.pdf Referenced Standard and Year(of Standard) Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 Equivalence of Product Standards Certified By Sections from the Code Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 11 49915 Dwg.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports other: Please see Eval report for Limits of Use. FL27499 R4 AE 49915 Eval p.Jf Created by Independent Third Party: Yes 27499.16 — DM Class 1750 1 3/4"Snaplock .032"aluminum roof panel, 18"wide,with 1 3/4"Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49916 Dwg_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49916 Eval.pdf Created by Independent Third Party: Yes 27499.17 DM Class 1750 1 3/4"Snaplock 24 Ga.galvalume coated steel roof panel, 18"wide,with 1 3/4 Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 49917 dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49917 Eval.pdf Created by Independent Third Party: Yes 27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18"wide,with 2"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49918 Dwq_ df Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49918 Eval.pdf Created by Independent Third Party: Yes 27499.19 DM Ciass 2000 2" Mechanical Seam 24 Ga.galvalume coated steel roof panel 18 wide,with 2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49919 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49919 Eval.pdf Created by Independent Third Party: Yes 27499.20 DM Class 500 5V Crimp 6 Ga,galvalume coated steel roof panel,24"wide,with SV crimp. e Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49920 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49920 Eval.pdf Created by Independent Third Party: Yes Go to Page 0 Page 1/2 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone•550-487-1824 The State of Florida is an AA/EEo employer.CgRynyht 2007-2013 State of Florida.::privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaits provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 4SS,F.S.,please dick tlgrr,. Product Approval Accepts: WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING 15211 97th Road N West Palm Beach,FL 33412 Ph/Fx:(561)225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24"WIDE ROOF PANEL(FLPA#27499.20) MANUFACTURER: DYNAMIC METALS, LLC 3201 SE DOMINICA TERRACE STUART, FL 34997 To all concerned, The DM Class 500 Series 26 Ga, Galvalume 5V Crimp 24"Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443,38-450-44 and H2686,02- 450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "5VS-HZ"dated 8/15/19, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 4. Supplemental Calculations to support 5VS-HZ, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 24" (nominal) Fastener Spacing across panel: 12" (at Overlaps &Center Rib) Min. Slope: HVHZ: 2"112" Non-HVHZ: '/z'/12" (with Lap Sealant) 3"/12"(no Lap Sealant) SrxCIALIZING IN IMPACT P,�515TANT CiP1'AINWALL5, 51'0tTFl?0Nr5, &WINPObV5 Option#1 Option#2 Installation Installation Max. Design Pressure: -117.75 psf -206 psf Fastener Spacing: 4" From Ends, 16" Max. O.C. 4" From Ends, 8" Max. O.C. Min Panel Fasteners: #10x1 '/z" HiLo HWH Screw #10x1 '/2n HiLo HWH Screw with Weather-seal Washer with Weather-seal Washer Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ, in areas with windspeeds< 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ, in areas with windspeeds< 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be used to prevent galvanic reactions. Minimum Substrate: '/2' (15/32" min)4-ply CDX Plywood or%"solid wood planks (S.G. = .42 min) nailed to 2x rafters spaced 24" max.on center with 8d ring-shank nails spaced 6"on center. Note: The'/"wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5PFCIXIZING IN IMPACT I'._515TANT CUPfNNWA15, 5TOMFFONT5, & WINbOW5 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133. 5. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 6. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL#27499.20, DM Class 500". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3rd party QA provider, to the dimensions shown on Drawing 5VS-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re-Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. Thank you, t� ti 1,�1 '�>f No 623.54 w Scott Wolters FL PE#62354 STATE APR 15 2021 0. °F '141 , '„Jpre,L 5MCIALIZIN6 IN IWACf M515fANf CI tAINWALL5, SfO FRONT5, & WINPOWS