Loading...
HomeMy WebLinkAboutAPPROVED Reg and poly specsIdeal for use as a first stage regulator on any domestic size ASME or & DOT container in propane gas installations requiring up to 1,500,000 LISTED BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. • Large threaded W F.NPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. • Non Adjustable • Large flow orifice resists freeze ups due to water concentration in LPG vapor. • Design provides for good flow regulation at both high and low container pressures. • Built in relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates 'A" F.NPT downstream pressure tap for an easy inline check of the regulator's delivery pressure. • Molded diaphragm provides an o-ring type seal between the body and bonnet. • Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system. • Fully painted in brilliant red for complete corrosion protection. • Mounting bracket available as an accessory: part number 2302-31. Z a S�� f3 Body............................................................................................Zinc Bonnet.........................................................................................Zinc Spring.. ................................................_............................. Steel Seat Disc.................................................................Resilient Rubber Diaphragm...........................Integrated Fabric and Synthetic Rubber a e w m a c LV3403TR e.um, zso,000 sooaoa �sooa �mo.000 M_ FLOW PROPANE LV3403TR I Over Outlet LV3403TRV9 W F.NPT %" F.NPT '132" 10 PSIG 1,500,000 ` Maximum flaw based on inlet pressure 20 PSIG higher than the regWalor setting and delivery pressure 20% lower than the regulator selling and delivery pressure 20 % lower than the setting. A14 ;eAEU13. 100 Rego Dr. Elan, NC 27244 USA www.regoproducts.eom +1 (336) 449-7707 Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11" w.c. Ideal for medium commercial installations, vapor meter installations and normal domestic loads. • 90 degree right angle inlet to outer connection for meter or standard installations. • Large vent helps to prevent blockage and has %" F. NPT for vent piping. • With 15 PSIG inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. • Replaceable valve orifice and valve seat. • Straight line valve closure reduces wear on seat disc • Unique bonnet vent profile minimizes vent freeze over when properly installed. • Large molded diaphragm is extra sensitive to pressure changes. • Built in pressure tap has plugged ''A." F. NPT outlet. Plug can be removed with a 3/16" hex @Ilan wrench. • Select Brown Finish Can mount directly to vapor meter. It is also suitable for mounting directly to the house piping. It will retrofit into existing installations that are currently using a 90 degree, right angle regulator. MaR-Ti'y Body........................................................................... Die Cast Zinc Bonnet........................................................................ Die Cast Zinc Nozzle Orifice......................................................................... Brass Spring...................................................................................... Steel Valve Seat Disc ..................................................... Resilient Rubber Diaphragm ......................... Integrated Fabric and Synthetic Rubber P EMONIE0 E E y013 �rD12 •'• � a is • yp10 om 9 c CFI-14r. I MAY, X 8 PSIG 50 100 150 'e 250.000 50[ LV"(131366RA 11" w.c. at 10 LY4403B66RAB^ 3/a" F. NPT W F. NPT 3l16" PSIG Inlet 9" to 13" w.c. Over Inlet w/Mawdingftadmt 1,000.000 W • Maximum flow is based on 10 PSIG Inlet and 9' w.c. delivery pressure. " Mounting Bracket Included. ••��f 7 100 RegO Dr. Flon, NC 27244 USA www.regoproducls.com +1 (336) 449.7707 AME"1r0- Lill ES-D-GAC Generac InstallSmart Job Name _ ,fob Location Engineer Approval _ Generac®MART Flexible Fuel Lines The flexible connection between the gas supply and the gas inlet of a GeneracO Stationary Outdoor Backup/Standby Generator Features • Operating Temperature -40°F to 150°F (-40°C to 65.6°C) • Operating Pressure MAX 0.5psi (3.45 kPa) • Hydrostatic Burst Pressure MIN 250psi (1725 kPa) • Flexible Tube Material Annealed 304 Stainless Steel • Flare Nut Material Carbon Steel with Zinc Trivalent Chromate Plating • Flare Adapter Material Carbon Steel with Zinc Trivalent Chromate Plating • PVC Dip Coating Gray Heavy Duty, Antimicrobial, UV Stabilizer CSA Group Certificate of Compliance to Product Standards ANSI Z21.75/CSA 6.27 — Connectors for Outdoor Gas Appliances and Manufactured Homes Scope states "...intended for exterior use above ground for making non -rigid connections... between the gas supply and the gas inlet of an appliance for outdoor installation that is not frequently moved after installation." In addition section 1.5.4 states the connector is designed for occasional movement after installation. Repeated bending, flexing or extreme vibration must be avoided. Normal operation of a clothes dryer, rooftop HVAC unit or SIMILAR OUTDOOR APPLIANCE DOES NOT constitute extreme vibration or movement. ANSI Z21.24/CSA 6.10 — Connectors for Gas Appliances S�` (Excluding 60/61 Series) c us Product Configurations Contractor Approval Contractor's P.O. No. Representative SKU For use with Generac stationary outdoor backup/ standby generators. Applicable Codes ANSI Z223.1/NFPA 54 National Fuel Gas Code Section 9.6 International Fuel Gas Code (IFGC) Section 411.1 B149.1 -- Natural Gas and Propane installation Code (CSA Group) Section 6.21 Uniform Mechanical Code (UMC) Section 1313.0 Uniform Plumbing Code (UPC) Section 1212.0 Additional Approvals Commonwealth of Massachusetts Beard of State Examiners of Plumbers and Gas Fitters Additional Testing UL2200-2015: Stationary Engine Generator Assemblies Section 66B Vibration Test. Dormont product specifications in us, customary units and metric are approximate and are provided for reference only. For precise D6fMiOlfht® measurements, please contact Dom7ont Technical Service. Dnrmnat reserves the right to change or modify product design, consi ucbon, specifications, or materials without prEor notice and without Incurring any obligation to make such changes and modifications on Dormont products previously or subsequently sold. Refer to the owner's manual for warranty Information. A WATTS Brand Minimum Flow Capacity at Specified Pressure Drop Straight Length BTU/hr. NATURAL GAS, 0.64 SG, 1000 BTU/tuft. CONFIGURATION I• I'I' L, I 1 Generac• Dorman? SERIES Nominal Si} Nominal Lenght 0.50 in 0.75 in 1.00 In 1.25 in 1.50 in 115 3n 2.00 in Part Number 10000009793 Part Number CAN41-4141-24GEN 41 in 1/4 in 24 290,900 356,278 411,395 459,953 503,854 544,224 581,800 10000009776 CAN41-4141-48GEN 41 3/4 48 217,I)G0 265,770 306,884 343,107 375,855 405,970 434,000 10000009777 CAN41-414172GEN 41 3/4 72 173,900 212,983 254,932 247,960 3D1,204 325,337 347,800 10000000498 CAN51-5151-24GEN 51 1 24 581,800 712,557 822,789 919,907 1,007,707 1,088,448 1,163,600 10000000499 GAN51-5151-48GEN 51 1 48 442,700 542,195 626,072 699,970 766,779 828,216 885,400 10000000500 GAN51-5151-72GEN 51 1 72 347,800 425.966 491.863 549,920 602,407 650,674 695.600 Straiaht Length BTU/hr. LP GAS, 1,55 SG, 2500 BTU/cu.ft. Generac• Part Number CONFIGURATION Dormord° Part Number SERIES Nominal ID in Nominal Lenght in 0.50 in 0.75 in PRESSURE ''O' 1.00 in (INCHES WATER 1.25 In COLUMN) 1.50 in 1.75 in 2.00 in 10000009793 CAN41-4141-24GEN 41 1/4 24 465,00 569,996 658,175 735,862 806,096 870,684 930,800 10000009776 CAN41-4141-48GEN 41 Y4 48 344,000 421,312 486,489 543,912 595,825 643,565 688,000 10000009777 GAN41-4141-72GEN 41 3/4 72 278,240 340,773 393,491 439.936 481,926 520,539 556,490 10000000498 CAN51-5151-24GEN 51 1 24 930,880 1,140,091 1,316,463 1,471,851 1 1,612,331 1,741,517 1,861,760 10000000499 CAN51-5151-48GEN 1 51 1 1 48 708,320 867,511 1,001,716 1,119,952 1 1,226,846 1,325,145 1,416,640 10000500500 CAN51 5151 72GEN 51 1 1 72 556,480 681,546 786,982 879,8721 963,852 1,041,079 L1,112,960 Generac part number 10000000498 (Dormont part number CAN51-5151-24GEN) can supply a minimum of 581,800 BTU/hr.of natural gas @ 0.50 in. water column pressure drop to the generator. All installations must completely comply with all Dormont® manufacturing company warnings and instructions, national, state and local codes and all applicable ANSI standards. D6fMont A WATTS Brand ES-D-GAC Generac InstallSmart 1703 USA: T: (800) 357-6668 • F: (724) 733-4808 • Dorrnont.com Canada: T: (905) 332-4090 • F: (905) 332-706B • Dormont.ca Latin America: T: (52) 61-1001-8600 • F: (52) 81-BODG-7091 • Dormont.com © 2016 Dormont Maximum Capccily of PIE Pipe in Thousands of BTU per Hour of Liquified Petroleum Gas Ci 3cis of 11.0 lij,'-,l�C cnd µ Piscsui—= Drop:. of 2.EIl,!12C (based on a 1.52 specl6c gravW gas) 1.87 125 99 84 74 67 56 50 45 41 38 35 33 24 26 1073 720 571 484 425 383 325 286 257 235 218 204 192 169 152 1391 934 740 627 551 497 421 370 333 305 283 264 249 219 197 1983 1331 1054 893 786 708 600 528 475 435 403 376 354 311 280 3563 2391 1894 1605 1412 1272 1078 948 854 781 723 676 636 560 504 4724 3247 2608 2232 1978 1792 1534 1359 1232 1133 1054 989 934 828 750 10063 6755 5351 4535 3989 3592 3044 2678 2411 2207 2044 1910 7797 1587 1424 22 20 18 15 13 12 11 10 9 9 8 8 8 7 7 129 113 102 86 76 68 63 58 54 51 48 46 44 42 40 167 147 132 112 99 89 81 75 70 66 63 60 57 54 52 238 209 188 160 140 126 116 107 100 94 89 85 81 78 75 427 376 338 287 252 227 208 192 180 169 160 152 146 140 184 642 569 516 441 391 354 326 303 285 269 255 244 233 224 216 1207 1061 956 810 712 642 587 544 508 478 453 431 411 894 379 25 i 68TUh,1 CFH Maxim um Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with c Gas Pressure of 2.0 psi and a Pressure Drop of 1.0 psi {based on a 1.52 speolfio gravity g(3s) 1966 1319 1045 886 779 702 595 3 5271 4 431 399 373 351 3�09 �278 11300 7586 6008 • 5092 4479 4033 3418 3007 2707 2478 2295 2144 2018 1775 1699 14652 9835 7790 6602 5807 5229 4432 3898 3510 3213 2975 2780 2617 2302 2073 20877 14014 11100 9408 8276 7451 6315 5555 5002 4678 4239 3962 3729 3280 2953 37514 25183 19946 16905 74869 13389 7T348 9982 8988 B226 7618 7119 6700 5894 5307 43429 29848 23969 20515 18182 16474 14100 12496 71322 104T7 9697 9092 8589 7612 6897 105963 71131 56339 47750 42000 37820 32054 28194 25388 23234 21517 20108 18926 16647 14990 230 1U/ 187 158 139 125 115 106 99 93 88 84 80 �® 74 1355 1192 1073 910 800 720 659 611 571 537 508 484 462 443 425 1757 1545 1391 1179 1037 934 855 792 740 696 659 627 599 574 551 2503 2202 1983 7680 1478 1331 1218 1128 1054 992 939 893 • 653 818 786 4498 3956 3563 3019 2656 2397 2189 2027 1894 1783 1688 1605 7533 1469 1412 6903 5232 4740 4057 3596 3258 2997 278E 2616 2471 2347 2239 2144 2060 1985 12705 11175 10063 8529 7502 6755 6182 5725 5350 5036 4767 4535 4331 4150 3988 2516BTUh= i CFH Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 10.0 psi and a Pressure Drop of 7.0 psi (based on a 1.62 speol8c gravity gps) 2476 1662 1316 1116 981 884 749 659 593 �543�03 470 442 38 14234 9555 7568 6414 5642 5080 4306 3787 3410 3121 2890 2701 2542 2236 2014 i84455 12388 9812 8376 7315 6587 5583 4910 4422 4047 3747 3502 3296 2899 2611 26296 17652 13961 11849 10423 9385 7954 6997 6300 5766 5340 4990 4697 4131 3720 47252 31720 25123 21293 18729 16865 14294 12572 11321 10361 9595 8967 8440 7423 6686 5396U 37087 29782 25489 22591 20469 17519 15527 14068 12943 12041 11297 10671 9458 8569 133476 89601 70967 60148 52905 47640 40376 35514 31980 29267 27104 25329 23840 20970 18882- 29/ 261 235 199 175 158 144 134 126 118 111 '106�� 10'1 1707 1501 1352 1146 1008 907 830 769 719 676 640 609 582 557 536 2213 1946 1753 1485 1306 1176 7077 997 932 877 830 790 754 723 695 3153 2773 2497 2116 1862 1676 1534 1421 1328 1250 1183 1125 1075 1030 990 5665 4983 4487 3803 3345 3012 2757 2553 2386 2246 2126 2022 1931 1851 1779 7334 6500 5890 5041 4468 4048 3724 3465 325T 3071 2916 2782 2664 2560 2466 16004 14077 12676 10743 9449 8509 7787 7212 6739 6343 6005 5712 5455 5227 5024 2516BTUh=1CFH Ph: 1.800,662,0208 o Fax: 615.325.9407 v Web. www.gastite.corrl 7