Loading...
HomeMy WebLinkAboutAPPROVED Permit Appl for 1406 N 35th St AdditionalST LUCIE Section A (General Information) Master Permit No. Contractors Name: ONE CONSTRUCTION & ROOFING CONTRACTORS, INC Job Address 1406 N 35th Street Fort Pierce, FI 34954 M Low Slope ® Asphaltic Shingles ❑ New roof ❑ Repair Low Slope Roof Area (SF) 600 sq ft Process No. License # CCC-1330623 ROOF CATEGORY ❑ Mechanically Fastened Tile 0 Metal Panel/Shingles ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ Mortar/Adhesive Set Tiles ❑Wood Shingles/Shakes ❑ Maintenance 0 Reroofing ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 3909 SQ. Ft ❑ Recovering Total (SF) 4,509 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. P,:Tfi tS'S? S 18 iU E Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: POLYGLASS USA Product Approval No.: FL#1654-R27 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': -36.1 Zone 1: -36.1 Zone 2: -47-7 Zone 3: -64.9 Max. Design Pressure, from the specific product approval system: Peet & Stick / SBS-SA Deck: Type: Plywood Gauge Thickness: 19/32 CDX Slope: 1112 Anchor/Base Sheet & No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: NIA Top Insulation Layer: NIA Top Insulation Sze and Thickness: N/A Top Insulation Fastener/Bonding Material: NIA Base Sheet(s) & No. of Ply(s): (1) Base Sheet Fastener/Bonding Material: SELF -ADHERING Ply Sheet(s)' & No. of Ply(s): N/A Ply Sheet Fastener/Bonding Material: N/A Top Ply: (1) Top Ply Fastener/Bonding Material: SELF -ADHERING Surfacing: NIA Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ "oo Zone 1:_..-." oc @ Lap, # Rows @ "oo Zone 2:._-_--" oc @ Lap, # Rows ® "0 Zone 3:—" oc @ Lap, # Rows @ . OC Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. T. LUCK Section D (Steep Slope Roof System) Roof System Manufacturer: Tamko Building products Notice of Acceptance Number: Fi # 18355-R6 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: -38.1 Zone 2e: -50-2 Zone 2n: -5�one 2r: -49.6 Zone 3e: -5�one 3r: -50.2 Deck Type: + 19/32 CDX Plywood \Typendeent: Tri-built I peel & stick Roof Slope: 5 ; 12 N/A rrier: NIA RidgeVentilation?tener Type & Spacing: 1-114" x .120 Coil Nails 16 nails pattern = 1-2-2-1 NIA Adhesive Type: NIA Type Cap Sheet N/A l r Mean Roof Height: 12' Roof Covering: Shingle / Tamko Type & Size Drip 2" x 2" /Aluminum Edge: '