HomeMy WebLinkAboutAPPROVED Permit Appl for 1406 N 35th St AdditionalST LUCIE
Section A (General Information)
Master Permit No.
Contractors Name: ONE CONSTRUCTION & ROOFING CONTRACTORS, INC
Job Address 1406 N 35th Street Fort Pierce, FI 34954
M Low Slope
® Asphaltic Shingles
❑ New roof ❑ Repair
Low Slope Roof Area (SF) 600 sq ft
Process No.
License # CCC-1330623
ROOF CATEGORY
❑ Mechanically Fastened Tile
0 Metal Panel/Shingles
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ Mortar/Adhesive Set Tiles
❑Wood Shingles/Shakes
❑ Maintenance 0 Reroofing
ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF) 3909 SQ. Ft
❑ Recovering
Total (SF) 4,509
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
P,:Tfi
tS'S?
S 18 iU E
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: POLYGLASS USA
Product Approval No.: FL#1654-R27
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': -36.1 Zone 1: -36.1 Zone 2: -47-7 Zone 3: -64.9
Max. Design Pressure, from the specific product approval
system: Peet & Stick / SBS-SA
Deck:
Type: Plywood
Gauge Thickness: 19/32 CDX
Slope: 1112
Anchor/Base Sheet & No. df Ply(s): N/A
Anchor/Base Sheet Fastener/Bonding Material:
N/A
Insulation Base Layer: N/A
Base Insultation Size and Thickness: N/A
Base Insulation Fastener/Bonding Material:
NIA
Top Insulation Layer: NIA
Top Insulation Sze and Thickness: N/A
Top Insulation Fastener/Bonding Material:
NIA
Base Sheet(s) & No. of Ply(s): (1)
Base Sheet Fastener/Bonding Material:
SELF -ADHERING
Ply Sheet(s)' & No. of Ply(s): N/A
Ply Sheet Fastener/Bonding Material:
N/A
Top Ply: (1)
Top Ply Fastener/Bonding Material:
SELF -ADHERING
Surfacing: NIA
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows
@ "oo
Zone 1:_..-."
oc @ Lap, # Rows
@ "oo
Zone 2:._-_--"
oc @ Lap, # Rows
® "0
Zone 3:—"
oc @ Lap, # Rows
@ . OC
Number of Fasteners Per Insulation Board:
Zone 1': Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
T. LUCK
Section D (Steep Slope Roof System)
Roof System Manufacturer: Tamko Building products
Notice of Acceptance Number:
Fi # 18355-R6
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: -38.1 Zone 2e: -50-2 Zone 2n: -5�one 2r: -49.6 Zone 3e: -5�one 3r: -50.2
Deck Type: + 19/32 CDX Plywood
\Typendeent: Tri-built I peel & stick
Roof Slope:
5 ; 12
N/A
rrier: NIA
RidgeVentilation?tener Type & Spacing: 1-114" x .120 Coil Nails 16 nails pattern = 1-2-2-1
NIA
Adhesive Type: NIA
Type Cap Sheet N/A l
r
Mean Roof Height: 12' Roof Covering: Shingle / Tamko
Type & Size Drip 2" x 2" /Aluminum
Edge: '