HomeMy WebLinkAbout5380-Revision Narrative_v2020.00 - v2020.1Disc Description Dwgs
A Add customization level in the title, below
the Prototype line
CS
A Add to note "Filler Panel to match adjacent
panel surface"
A1
A Wall behind Freestyle to be changed to be
6".
A1, EQ1
A Wall behind follett to be 16 GA studs.A1
A
Eliminate Building Centerlines on Architectural Drawings. A1, EQ1,
CHECK
PLANS
A Door Schedule - Add Roof Access Panel.A1
A Create an A1.1 sheet for a Dimension Plan.A1.1
A Hard ceiling over Reach-Ins to match fl in
height - 8' - 0"
A2
A Detail 8/A3 - Replace Metal Cap and note
with walk pad.
A3.1
A Roof Plan - Make 1/4" Scale.A3
A
Window section details - Added General
Note clearly stating/showing insulation type and r-value for built up
headers.
A7
A Checkout Flooring Detail - Change "Refer
to Specifications" to "Refer to Schedule"
A11
A
Vestibule Mat - Rear - Coordinate with remodels to show graphics for
3' - 0" mats A11
A
Equipment & Counters Elevations - Added 3' Min Dim string @ pick
up counter
elevation.
AC1
A
Equipment Schedule - Removed "Sizzli" from labels. Replace with
"Convection
Oven"
EQ1
A Update prototype version to 2020.01 CS
A Update sheet numbering format.CS
A Removed note 4 under separate permits CS
A
In Managers Office- Change wall sheathing on the left side of the
door to be 1/2" plywood sheathing in place of 1/2" GWB.A1
A In Managers Office - FRP wall finish to
extend to ceiling
A1
A In Associates area - FRP wall finish to
extend to ceiling
A1
5380 F85FB Revision Narrative - v2020.0 To v2020.1
A Beer Cave - Add hold dimension between
two framed walls
A1.1
A Beer Cave - Add clear to 2" dimensions to
space surrounding WIB
A1.1
A,P Change Hi-Lo Water Fountain to Hi-Lo
Drinking Fountain
A1
A
Delivery Vestibule - Remove note: Provide 5/8" plywood floor to
ceiling on this wall.
finish to be FRP
A1
A
Delivery Vestibule - WIB Finish to be black in vestibule and SS in
areas visible from
Retail Area
A1, A8
A Delivery Vestibule - Correct door jamb
detail for wall juncture at WIB
A1
A
Water Service Room - Show access
panel location for temporary water hookup.A1
A
Water Service Room - Relocate CO2 Fill Box to above temporary
water hookup
location.
A1
A
Water Service Room - Relocate CO2 Fill Box to above temporary
water hookup
location.
A1
A Water Service Room - coordinate water
Softening System w/ Plumbing drawings
A1
A Water Service Room - coordinate and
redraw detail 13/A9.
A1,A9
A Retail WIB - Add Hold Dimension between
framed walls
A1.1
A,M,E,P Women's Restroom - Modify accessible
stall and relocate framed walls.
A1,A8
A
Women's Restroom - only show overall dimensions and add
additional dimensions
to plan detail
A1.1,A8
A Men's Restroom - Change south wall
adjacent to backroom to 6" metal studs.
A1, A8
A
Men's Restroom - Change east
wall adjacent to backroom to 3 5/8"" metal studs.A1, A8
A Ice Merchandiser Alcove - Add hold
dimension
A1
A Food Service - Door W6 Double acting door
need correct jamb and frame detail.
A1, A9
A Food Service - Add 12x18 AP for access to
hub drain at Reach in freezer.
A1, A8
A Staging - Add hold dimension at the mop
sink.
A1.1
A Staging - Revise Water heater note to
include Pre-Cast Concrete Pad.
A1
A
Staging - Add detail of Threshold at door T6 to include threshold to
the edge of slab.A1, A7
A Wash Room - Show bulkhead at Food
Service WIB and create section.
A1
A Wash Room - Door W1 to get detail similar
to door W6 in Food Service
A1, A9
A Food Service WIB - Add hold dimensions
between framed walls.
A1.1
A Food Service - Add Blocking for Cat Lock A1
A Vestibule (front) -Remove Ultra Entry Mat
note.
A1
A General - all Dimensions are to stud and
not Sheathing
A1.1
A General - Call out height of Durock around
WIB's
A1
A
General Notes- Add note: Refer to civil drawings for location
landscape area
adjacent to building.
A1
A Equipment Blocking Notes - add height of
blocking for air curtain
A1
A Equipment Blocking Notes -add blocking for
Catlock
A General - Remove all room numbers from
room name tags
A1,A2
A Door Schedule - Door T2 add detail 27/A7
to comment section
A1
A Beer Cave - Ceiling height to be 10'-0"A2
A Delivery Vestibule - Call out air curtain, see
mech. dwg's
A2
A Delivery vestibule - show soda chase and
call out detail
A2
A
Retail WIB - Add access panel in ceiling of retail WIB. Coordinate w/
mech. and elec.A2
A
Retail WIB - Add 30x30 framed opening in
wall adjacent to Womens Restroom above WIB A2
A Rear Vestibule - remove transfer grill,
coordinate w/ mechanical
A2
A
Men's Restroom - remove note: mr gwb on 8" 16ga metal studs at
24" o.c. typ at men's and women's restrooms and rear vestibule A2
A Electrical Room - Change ceiling type from
ACT1 to ACT2
A2
A Washroom - Change ceiling height from 10'-
6" to 10'-0"
A2
A Washroom - show bulkhead at opening to
Food Service WIB.
A2
A Washroom - Add section callout for
bulkhead at entry to Food Service WIB.
A2
A Backroom - Change ceiling height from 10'-
6" to 10'-0"
A2
A Food Service - Change ceiling height from
10'-6" to 10'-0"
A2
A Ice Merchandiser Alcove - Change ceiling
type from ACT1 to ACT2
A2
A Express Case Alcove - Change ceiling type
from ACT1 to ACT2
A2
A Express Case Alcove -Add (2)24x24 egg
crate diffusers. coordinate w/ Mech
A2
A General - Revise soffit layout per revised
design
A2
A Exterior Canopy - Call out soffit material A2
A Detail 2/A2 - Call out soffit material.A2
A
Detail 6/A2 - Update detail to show blocking for signage. Delete
similar detail on sheet
A9
A2, A9
A Detail 9/A2 - Change plywood and finish to
Azek
A2
A
Detail 10/A2 - Add 3/4" quarter round painted P1 to underside of
bulkhead adjacent to WIB. Note to include information about not
mechanically
fastening to the WIB.
A2
A
General Note 2 - Add paint color to match underside of bulkhead.
note to include information about not mechanically
fastening to WIB A2
A Lotto Satellite Dish - Remove walk pad
note.
A3
A Add WIFI devices to the front corners of the
building.
A3
A Detail 9/A3 - Add note to refer to NOA for
fastening.
A3.1
A Detail 6/A3 - Remove Metal cap and
change to walk pad.
A3.1
A Compressor Platform - update information
callouts.
A3.1
A Detail 1/A3.1 - Modify fascia detail to match
detail 13/A3.1
A3.2
A Detail 5/A3.1 - Modify fascia detail to match
detail 13/A3.1
A3.2
A Detail 5/A3.1 - Rename detail to Fascia
Detail
A3.2
A Detail 12/A3.1 - Coordinate parapet cap
detail callout
A3.2
A Detail 16/A3.1 - Add Lath to detail A3.2
A Detail 16/A3.1 - Change detail scale from 1'-
0" to NTS.
A3.2
A Detail 25/A3.1 - Add detail callout
referencing 18/A3.1
A3.2
A Detail 13/A3.1 - Revise note to Correct size
of continuous fascia blocking.
A3.2
A Detail 26/A3.1 - Add material callout of
Escutcheon Ring.
A3.2
A Detail 26/A3.1 - change downspout note to
remove S.S.
A3.2
A Detail 28/A3.1 - Add material callout of
Escutcheon Ring.
A3.2
A Detail 28/A3.1 - change downspout note to
remove S.S.
A3.2
A General - Coordinate material callout for
exterior trim.
A3.2
A Front Elevation - Change spandrel glazing
to tinted tempered glazing.
A4
A Front Elevation - Add dimension to light
fixture height.
A4
A Front Elevation - Add detail callout to light
gauge truss note.
A4
A Front Elevation - Add film to windows in
coffee are to conceal equipment.
A4
A Right Elevation - remove horizontal mullion
at walk-up window location.
A4
A Right Elevation - Add arrow to callout for the
scupper box
A4
A
Exterior Finish Schedule - DS, DS1, DS2 delete gauge from schedule
and update
Specifications book to include.
A4, Spec.
Book
A Exterior Finish Schedule - CO2 coordinate
detail callout in notes section.
A4
A Exterior Finish Schedule - LADD refence
details in notes sections.
A4
A
Exterior Finish Schedule - MTPN,MNTP2
change manufacturer to match PBS Bahama Shutter.A4
A Exterior Finish Schedule - TH remove from
schedule
A4
A Detail 5/A4 - Add (MTPN) to title A4
A Detail 6/A4 - Add (MTPN2) to title A4
A General Notes - Remove note 3 A4
A General - Tag emergency lights.A4.1
A
Rear Elevation - Move rear tower downspout to the exterior of the
tower to
avoid the pier and footing.
A4.1
A Rear Elevation - Add Dimension for Tower
Lights.
A4.1
A Rear Elevation - At rear tower clarify arrow
location of STU2 tag.
A4.1
A
Rear Elevation - Relocate CO2 Fill port to Left Side Elevation above
6x6 access panel
for thru wall pipe.
A4.1
A
Rear Elevation - Change note Paint Louver EP6 to match stucco to
Louver, Re Mech.
Drawings.
A4.1
A Left Side Elevation - Add duplex outlet for
Ice Merchandiser.
A4.1
A, E
Left Side Elevation - relocate Special Purpose out closer to wall
hydrant. Align
height of outlet and hydrant.
A4.1
A 1/A5 - Correct haunched exterior footing to
show removed cast stone base.
A5
A 2/A5 - Correct WIB wall Height A5
A 1/A6 - Correct Height of light fixture in
Tower.
A6
A 1/A6.1 - Remove wall finish hatch.A6.1
A 3/A6.1 - Show HSS tube steel in knee wall.A6.1
A 4/A6.1 - coordinate height of Durock at WIB A6.1
A 4/A6.1 - Remove WIB filler panel at ceiling
height
A6.1
A 4/A6.1 - correct footing due to removal of
stone base
A6.1
A 5/A6.1 - correct exterior wall flashing to mat
old detail.
A6.1
A 11/A6.1 -correct wall flashing at column.A6.1
A 1/A6.2 - Terrazzo to stop at face of wall.A6.2
A 1/A6.2 - Show HSS tube steel in knee wall.A6.2
A 3/A6.2 - Coordinate note: Accent trim
beyond per finish schedule re:sheet A4
A6.2
A 3/A6.2 - Coordinate size of 2x6 Hardie Trim
above storefront at tower.
A6.2
A 8/A6.2 - Update detail to show correct
stucco layers.
A6.2
A
Detail 3/A7 , 6/A7and 12/A7 are all similar and do not require multiple
versions.A7
A Detail 9/A7 - Remove detail A7
A Detail 13/A7 - Call out trim (including size).A7
A Detail 18/A7 - removed dashed line of light
fixture
A7
A Detail 18/A7 - change callout for 1 1/2" trim
board to trim board, size varies.
A7
A
Detail 18/A7 - Change detail title from Exterior Light Mounting detail
to Exterior
Device Mounting Detail.
A7
A 1/A8 - Remove Glazing Type from Elevation A8
A 2/A8 - Show Blocking for Water Fountain A8
A 3/A8 - Change Kick-Plate size A8
A 4A/A8 - Coordinate WIB door swings A8
A 4A/A8 - Show trim kits and opening for
Freestyle in self-Serv. Beverage
A8
A 4A/A8 - Show blocking for Follett shelf A8
A 5/A8 - Show Access Panel A8
A 7/A8 - Coordinate WIB door swings.A8
A
8/A8 - Revise note: Soap and Paper Towel dispenser to be finished
black to Soap and
Paper Towel Dispenser
A8
A 9/A8 - Remove Glazing Type from Elevation A8
A Interior Finish Schedule - EF-1 Supplied By
changed to Wawa
A8
A Interior Finish Schedule -FRPC Remarks,
Remove sheet size.
A8
A Interior Finish Schedule - GWB, Remove
from schedule
A8
A
Interior Finish Schedule - IMG1 - Change Impact Specialties to
Construction
Specialties as per bulletin.
A8
A
Interior Finish Schedule - M2Change color from jailhouse rock to
match bulletin #466 A8
A Interior Finish Schedule - Add ISL2 for
black finish
A8
A 1/A8.1 - Note I: Reference sheet AC1 for
accessibility requirements.
A8.1
A 10/A8.1 - Coordinate Fire Extinguisher
location at conflict w/ shelving
A8.1
A 13/A8.1 - Remove selected metro racks A8.1
A 13/A8.1 - Show missing FRPC wall hatch A8.1
A 18/A8.1 - coordinate kick-plate height A8.1
A 20/A8.1 - Remove Lover from door and add
kick-plate
A8.1
A 21/A8.1 - Add finish tag for ISL2 A8.1
A 21/A8.1 - remove white finish note from
walk-in refrigerator.
A8.1
A 22/A8.1 - coordinate kick-plate height A8.1
A 23/A8.1 - Add soda Chase A8.1
A 23/A8.1 - Add Dimension to top of surge
tank shelf.
A8.1
A 24/A8.1 - coordinate kick-plate height A8.1
A 24/A8.1 - Add soda Chase A8.1
A 31/A8.1 - Update detail to remove tile above
Corian
A8.1
A 3/A8.2 - Tag and hatch break metal finish at
storefront.
A8.2
A 14/A8.2 - FRP Finish to 10'-0"A8.2
A 15/A8.2 - FRP Finish to 10'-0"A8.2
A
15/A8.2 - 1/2" plywood sheathing in place of 1/2" GWB sheathing full
height to left of
door.
A8.2
A 16/A8.2 - FRP Finish to 10'-0"A8.2
A 17/A8.2 - FRP Finish to 10'-0"A8.2
A 8/A9 - remove height and add note to see
elevations for height.
A9
A 9/A9 - Revise as per finish revisions.A9
A 12/A9 - Move soap dispenser over sink A9
A 13/A9 - Review Graphics and intent of
detail.
A9
A 17/A9 - Add detail for double acting door
frame and jamb.
A9
A 18/A9 - Remove tile behind endcap at face
of wall.
A9
A 18/A9 - Revise endcap note to include floor
to ceiling.
A9
A
30/A9 - confirm value of detail as information is shown in alternate
locations.A9
A 3/A9.1 - Remove detail as information is
shown on A2
A9.1
A 4/A9.1 - Revise detail to larger scale and to
include an elevation.
A9.1
A 29/A9.1 - Add Rear Vestibule plan detail.A9.1
A Revise Plan to show knee wall at front
elevation
A11
A Confirm dimension coordination w/ Civil.A11
A 18/AC1 - Add Note: If Signe does not fit in
this location, place on door.
AC1
A Office - remove text from Veeder Root EQ1
A Exterior (Left Side) - Ice Merchandizer to be
tagged Z12
EQ1
A Exterior (Left Side) -Remove detail callout
from ladder
EQ1
A Water Service Room - CO2 Tank to be
tagged Z10
EQ1
A Water Service Room - CO2 Fill location to
be updated as per A1
EQ1
A Exterior (Rear) - Callout Trash / Recycle
Receptacle.
EQ1
A Women's Restroom - Update layout EQ1
A Rear Vestibule - Add door thresholds.EQ1
A Men's Restroom - Update layout EQ1
A Wash Room - Call out Metro shelves above
3-comp sink.
EQ1
A Wash Room - Change dimensions to 1/8"
tolerance.
EQ1
A Wash Room - Tag Metro Shelves and
Bakery Rack.
EQ1
A Self-Serv. Beverage - Add Access Panel in
Cup Cabinet.
EQ1
A Self-Serv. Beverage -Tag Ice Merchandiser
C5.3
EQ1
A Self-Serv. Beverage - Remove splash
guard from hand sink
EQ1
A Food Service -Add Speed rack EQ1
A Food Service - Add Deli phone next to
catlock.
EQ1
A Food Service - Remove note: Crunchy
Salad Toppings
EQ1
A Food Service - Relocate KPS monitor note
for clarity.
EQ1
A Full-Serv Beverage - Add KPS at backline.EQ1
A Exterior (Right Side) - Add tags for exterior
seating.
EQ1
A Exterior (Right Side) -Dimension exterior
seating off of finished wall.
EQ1
A Exterior (Right Side) - Add clear dimension
at exterior seating.
EQ1
A Vestibule - Remove Floor note.EQ1
A Vestibule - Show door thresholds.EQ1
A General - Remove Floor finishes from plan.EQ1
A General - Update room tags to remove
room numbers.
EQ1
A General - update per the latest
Merchandise plan
EQ1
A Equipment Schedule - B26.3 add
information.
EQ1
A Equipment Schedule - CO2 tank add tag
Z10
EQ1
A
Equipment Schedule - Outdoor Ice Merchandiser add tag Z12 and
installed by
vendor.
EQ1
A General - Revise Equipment tag Size to
smaller.
EQ1
A Island Express Case - remove EQ2
A Wall Express Case - Add EQ2
A CAT -Show outlets as quads and not duplex
size
EQ2
A CAT -Add data outlets.EQ2
A CAT -Correct EQ number EQ2
A Hot Food Table - Fix title on elevation to
Hot Food Table.
EQ2
A Hot Food Table - Show Hot Holding on
elevation.
EQ2
A Coffee Brewer - Remove Prentices from
plumbing information
EQ2
A Super Cappuccino - Update electrical
information.
EQ2
A Super Cappuccino - remove prentices from
plumbing information.
EQ2
A Refrigerated Food Prep - Correct elevation
title
EQ2
A ELO Time Clock - Relocate outlets below.EQ2
A Cat Lock - Relocate outlets below.EQ2
A Cat Lock - Remove Future from plan title.EQ2
A Milkshake Blender - Remove extra lines.EQ2
A Iced Coffee Brewer - Add Plan and
Elevation.
EQ2
A General - Fix Liveweights of dimensions.EQ2
S General - Show slab control joints.S2
S General - Add Dimension between Beer
Cave and Retail WIB.
S2
S General - Add Dimension between edge of
slab and Food Service WIB.
S2
S 1/S7.1 - Add note to coordinate color w/
Architecture.
S7.1
S 13/S7.1 - Update connection detail.S7.1
M
1/M1 - Implement Bulletin #463 - VAV
Diffuser replacement in Associates and Office with non-VAV and
adjust airflows.
M1
M
1/M1 -Change routing of transfer air duct between Water Service
Room and Retail area to thru-wall transfer from Water Service Room
to above ceiling area above
Retail WIB.
M1
M 1/M1 - Add (2)24x24 egg crate diffusers in
ceiling of express case alcove.
M1
M
1/M1 - Relocate return grilles for RTU-3 to open area and parallel to
existing Food
Service soffit.
M1
M 1/M1 - Relocate RTU-3 Thermostat to
location near the front vestibule.
M1
M
1/M1 - Relocate upper 365 CFM linear
diffusers in coffee to RTU-3 and redistribute air.M1
M Key Notes - Add note for direction of airflow
of linear diffusers.
M1
M 10/M3 - Add alignment note and dimension
to detail.
M3
M 11/M3 - Coordinate cap w/ Arch M3
M RTU Sequence of Operation - Update per
Bulletin #464
M3
M RTU Test And Balance Notes - Update per
Bulletin #464
M3
M Rooftop Unit Schedule Notes. - Update.M3
M HVAC Air Device Schedule - Remove
Device CD-4 from Schedule.
M3
P Relocate Roof Leader to the exterior of the
rear tower.
P1
P Women's Restroom - Relocate floor drain
to near hand dryer.
P1
P Men's Restroom - Relocate floor drain to
near hand dryer.
P1
P Men's Restroom - Relocate vent to wall
behind lav. cabinet.
P1
P Rear Vestibule - Relocate ECO to the right
and out of the centerline of the door.
P1
P Self-Serv. Beverage - Relocate Hub drain
between freestyle units.
P1
P Self-Serv. Beverage - Coordinate FCB hub
drain w/ Cup holder access panel.
P1
P Staging - Show housekeeping pad and
relocate FD-1
P1
P Washroom - Relocate floor drain to other
side of Food Service WIB.door.
P1
P Women's Restroom - Add Loop.P2
P Water Meter Room - Coordinate thru wall
Water hookup with Arch detail.
P4
P Remove Evap Coil Condensate from
Sanitary Riser.
P4
P 12/P5 - Add note to locate next to wall.P5
P 13/P5 - Coordinate height of CSR mounting
w/ Arch
P5
P 13/P5 - Add Iced Coffee (B51)P5
P Piping Material Schedule - Cold Water,
Change thickness to 1/2"
P5
P Piping Material Schedule - Hot Water, add
return and change thickness to 1/2"
P5
P Piping Material Schedule - Remove note 2 P5
P
Fixture Specifications - WCH-1, Change wall hydrant gas canopy to
Trash
compound.
P5
E Office - Update Data near door to 60"E1
E Beer Cave - Remove outlet for condensate
pump RPB-7
E1
E Beer Cave - Remove duplicate A2 tag, JB
and keynote 30
E1
E Beer Cave - Change Door Heat symbol to
C
E1
E Beer Cave - Get new signage information E1
E Retail WIB. - Change door heat symbol to C E1
E Retail WIB. - Add additional door heat
circuit.
E1
E Retail WIB. - Add height (84") to RPB-7 E1
E Retail WIB - Remove keynote 31 E1
E Exterior (Left Side) - Coordinate location
Special purpose outlet for Power Washer
E1
E Exterior (Left Side) - Ice Merchandiser, add
tag Z12
E1
E Exterior (Left Side) - Remove note intended
for 2nd Ice Merchandiser
E1
E Exterior (Left Side) -RPC-27 change to GFI
breaker. and change to in-use cover.
E1
E Food Service Freezer - Remove duplicate
A4 tag, JB and keynote 31
E1
E Food Service Freezer - Change door heat
symbol to C
E1
E Food Service Refrigerator - Remove
duplicate A3 tag, JB and keynote 31
E1
E Food Service Refrigerator - Change door
heat symbol to C
E1
E Food Service - Add Circuit to catlock outlet E1
E Food Service - Change data from 54" to 55"
at catlock
E1
E Lottery - use as template for tags and
circuiting.
E1
E 3/E1 - Tag Lights E1
E 3/E1 - remove EC shall provide from light
fixture note.
E1
E 3/E1 - Include Background E1
E Keynote 5 - Provide spec.E1
E Keynote 18 - Remove an isolated ground
(ig) from note.
E1
E
For all protos, fl, identify all equipment that needs to be gfi protected,
create a square d panel (move all food service equipment into this
panel) - can't change all to square d
due to cost -
E1
E Keynote 31 - Remove note.E1
E Beer Cave - Remove Occupancy Sensor
and keynote 6
E2
E Retail WIB - Add Two door light JB's (C)E2
E Rear Tower - Change DL2 to DL2E E2
E Men's Restroom - Occupancy Sensor is
overwriting keynote.
E2
E Ice Merchandiser Alcove - Confirm location
of battery pack w/ voltage drop.
E2
E Light fixture Schedule - RF, Add Trash
Enclosure to location.
E2
E Symbol Legend - "C" Symbol note to match
E1.
E2
E Add tags to light fixtures. On west Parapet
wall.
E3
E Add Keynote 6 to RTU's E3
E Remove Cap from Tower E3
E 2/E3 - Update detail for exterior of building E3
E Keynotes - Combine notes 2 and 6 E3
E Keynotes 6 - new note, GFI receptacle
furnished w/ HVAC unit wired by E.C.
E3
E Office - Move conduit for monumnet sign to
electrical room
E4
E Retail - Add 1" data and 1" power conduit
capped 1" above the f.f. with pull strings
E4
E Electrical Room - Remove note BAS Panel E4
E Electrical Room - Conduit See note 5 and 6 E4
E Full-Serv Beverage - Confirm if 1"C Data is
required.
E4
E Coffee - Relocate conduit in corner of
angled storefront.
E4
E Coffee Bar - Confirm if 1"C Data and 3/4"c
power is required.
E4
E
General Note 6 - Revise to 10' GRC - PVC - 10' GRC, Coordinate
with note on sheet E6 E4
E
Electrical Plan Note 6 - Remove portion of note, The electrical
contractor shall furnish and install a dedicated simplex outlet to
price change controller.E4
E
Electrical Plan Note 8 - Relocate, (1) 1" PVC to Each Air Machine to
note 1 and
modify description.
E4
E Panel RPC - Change Circuit 20 to Air
dispenser #2
E5
E Panel RPC - Change Circuit 36 to Air
dispenser #1
E5
E
Panel RPD - Remove LTG Track - Track Length Sign/Display
Signage and Display
Case.
E5
E Panel LPA - Remove, Refer to one-line
diagram
E5
E
Panel RPU - Remove LTG Track - Track Length Sign/Display
Signage and Display
Case.
E5
E 4/E6 - Remove Diesel Fuel Note E6
E 4/E6 - Update Gas Canopy GRC Note.E6
E 4/E6 - Left side conduit notes, Align text.E6
E 4/E6 - Air Machine, Change to 1 conduit
and change to Air Dispenser
E6
E 4/E6 - Change 1" GRC spare run to PVC,
see redlines
E6
E 4/E6 - Air Machine, Change 2 conduits to
checkout to 4
E6
E
4/E6 - Remove (1) 1" grc to simplex receptacle to price change
controller in
office area.
E6
E 4/E6 - Revise Graphics for conduits to stop
at the floor line.
E6
E 4/E6 - Revise Graphics for conduits to stop
at top of panels
E6
E
4/E6 - Confirm if 3" extension below panels are needed and if they
are included with the
shop drawings.
E6
E 5/E6 - Add, (1) 2" PVC to spares through,
see note 2 and detail redlines
E6
E 5/E6 - Add, (1) 1" PVC to Irrigation meter,
see detail redlines.
E6
E
5/E6 - change conduit note to tank
compartments to include (10 or 12 as required).E6
E 5/E6 - Add Price changer and receptacle to
elevation, see detail redlines.
E6
E 5/E6 -Show conduit symbols for all conduits E6
E 5/E6 - change (2) 2" PVC, Data to food
service to (3) 1", See detail Redlines
E6
E
5/E6 - Add (2) 1" PVC data to each price sign monument / pylon, See
detail Redlines E6
E 5/E6 - Add (1) 2" PVC to intercom trough,
see note 2, See detail Redlines
E6
E
5/E6 - Add entire length to GRC note to each submersible pump, See
detail
Redlines
E6
E electrical Room elevation Notes - remove
note 6
E6
E electrical Room elevation Notes - remove
note 8
E6
E Single Line Diagram - Change TVSS to
SPD
E7
E Single Line Diagram - SPD tag to
Equipment
E7
E Single Line Diagram - Remove "PowerPlus"
from Distribution title.
E7
E Single Line Diagram - SPD tag to
Equipment
E7
E Change electrical contractor shall obtain
integrated power to electrical
E7