HomeMy WebLinkAboutEnergy CodeK=tMD
AUG 2 s zozo
FORM R405-2017
. FLORIDA ENERGY EFFICIENCY CODE Fdk%k=SIG CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KENNEDY GABRIEL
Builder Name:
Street: 2908 AVE. Q
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: KENNEDY GABRIEL
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1120.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=19.0 1120.00 ft2
b. N/A
k= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1200.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1200.00 ft2
6. Conditioned floor area above grade (ft2) 1200
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(160.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: A/C
6 175
a. U-Factor: Sgl, U=0.54 120.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.32 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
18.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 6.125 ft.
Area Weighted Average SHGC: 0.262
14. Hot water systems
8. Floor Types (1200.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1200.00 ft2
b. Conservation features
EF: 0.950
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 43.67
Glass/Floor Area: 0.133
PASS
Total Baseline
Loads: 44.02
1 hereby certify that the plans and specifications covered by
Review of the plans and
eii%E Sr'4?�
this calculation are in compliance with the Florida Energy
specifications covered by this
y _ O�
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPA BY:
Before construction is completed
DATE: -
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5�
with the Florida Energy Code.
G'OD WME
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
pnvelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
File Copy
8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KENNEDY GABRIEL
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1200
Lot #
Owner Name: KENNEDY GABRIEL
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
2908 AVE. Q
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1200 9600
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 DINING
156 1248 No 0
1
Yes
Yes
Yes
2 LIVNG ROOM
340 2720 No 4
1
Yes
Yes
Yes
3 KITCHEN
80 640 Yes 0
1
Yes
Yes
Yes
4 LAUNDRY
24 192 No 0
1
No
Yes
Yes
5 BATH 2
54 432 No 0
1
No
Yes
Yes
6 BATH 1
63 504 No 0
1
Yes
Yes
Yes
7 BEDROOM 1
157 1256 No 1
1
1
Yes
Yes
Yes
8 BEDROOM 3
170 1360 No 1
1
1
Yes
Yes
Yes
9 BEDROOM 2
144 1152 No 1
1
1
Yes
Yes
Yes
10 A/C
12 96 No 0
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
DINING 25 ft 0
156 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
LIVNG ROOM 33 ft 0
340 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
KITCHEN 8 ft 0
80 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio
LAUNDRY 1 ft 0
24 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 2 1 ft 0
54 ft2
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BATH 1 9 ft 0
63 ft2
_---
0 1
0
' 7 Slab -On -Grade Edge Insulatio
BEDROOM 1 26 ft 0
157 ft2
----
0 1
0
8/15/2019 11:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio
BEDROOM 3 14 ft
0
170 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BEDROOM 2 25 ft
0
144 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
A/C 1 ft
0
12 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1300 ft2
0 ft2
Light
N
0.6
No
0.9 No 20
22.6
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
1200 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
DINING
0
Blown
156 ft2
0.1
Wood
2
Under Attic (Unvented)
LIVNG ROOM
0
Blown
340 ft2
0.1
Wood
3
Under Attic (Unvented)
KITCHEN
0
Blown
80 ft2
0.1
Wood
4
Under Attic (Unvented)
LAUNDRY
0
Blown
24 ft2
0.1
Wood
5
Under Attic (Unvented)
BATH 2
0
Blown
54 ft2
0.1
Wood
6
Under Attic (Unvented)
BATH 1
0
Blown
63 ft2
0.1
Wood
7
Under Attic (Unvented)
BEDROOM 1
0
Blown
157 ft2
0.1
Wood
8
Under Attic (Unvented)
BEDROOM 3
0
Blown
170 ft2
0.1
Wood
9
Under Attic (Unvented)
BEDROOM 2
0
Blown
144 ft2
0.1
Wood
10
Under Attic (Unvented)
A/C
0
Blown
12 ft2
0.1
Wood
WALLS
9
Orrit
Adjacent
10 Wall Typele
Cavity ity Width
Et In
Height
Et In
Area
Sheathing Framing
RA/alue Erartion
Solar
Ahqor rr:ptlp%
Below
1
NE
Exterior Frame - Wood
DINING
19 12
0 8
0
96.0 ft2
0
0.25
0.5
0
2
NW
Exterior Frame - Wood
DINING
19 13
0 8
0
104.0 ft2
0
0.25
0.5
0
3
SW
Exterior Frame - Wood
LIVNG ROO
19 16
0 8
0
128.0 ft2
0
0.25
0.5
0
4
NW
Exterior Frame - Wood
LIVNG ROO
19 17
0 8
0
136.0 ft2
0
0.25
0.5
0
5
NE
Exterior Frame - Wood
KITCHEN
19 8
0 8
0
64.0 ft2
0
0.25
0.5
0
6
NE
Exterior Frame - Wood
BATH 1
19 9
0 8
0
72.0 ft2
0
0.25
0.5
0
7
NE
Exterior Frame - Wood
BEDROOM 1
19 11
0 8
0
88.0 ft2
0
0.25
0.5
0
8
SE
Exterior Frame - Wood
BEDROOM 1
19 15
0 8
0
120.0 ft2
0
0.25
0.5
0
9
SW
Exterior Frame - Wood
BEDROOM 3
19 14
0 8
0
112.0 ft2
0
0.25
0.5
0
10
SE
Exterior Frame - Wood
BEDROOM 2
19 15
0 8
0
120.0 ft2
0
0.25
0.5
0
11
SW
Exterior Frame - Wood
BEDROOM 2
19 10
0 8
0
80.0 ft2
0
0.25
0.5
0
8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY iCI4FCKI IST RFPnPT
DOORS
#
Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1
SW
Insulated
LIVNG ROO None .39 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1
2
3
4
5
6
7
8
NE 1 Vinyl
NW 2 Metal
SW 3 Metal
NE 5 Metal
NE 6 Metal
NE 7 Metal
SW 9 Metal
SW 11 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.32 0.3 N 40.0 ft2 11 ft 0 in 1 ft 4 in
0.54 0.25 N 30.0 ft2 12 ft 0 in 1 ft 4 in
0.54 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in
0.54 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in
0.54 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in
0.54 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in
0.54 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in
0.54 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1120 61.49 115.63 .1233
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
SEER: 16 18 kBtu/hr cfm
0.7 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric
None
LAUNDRY
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY r.WFCKI IST RFMIRT
- -----------
DUCTS
----
----
/ ---- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6
175 ft2
Attic
65 ft2
Default Leakage
A/C
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat:
Y
Ceiling Fans:
Heating Jan f X�
Feb
Mar
ki
Apr
Ma
rl Jun
Jul
ri
Aug
rl
�XjSep
�j 0 Nov
Dec
Jan [
]Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Occt t Xj
Nov
DecVenting
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVNG ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/s .ff.
ft2
ft
0.3
A/C
8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: KENNEDY GABRIEL Builder Name:
Street: 2908 AVE. Q Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: KENNEDY GABRIEL Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
Y pp 9 /soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring,
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
gytgnd behind piping and woring-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinklpr Cayff-plato ago walls or ceilings
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/15/2019 11:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
A/C
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
18.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1200
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.485
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.262
14. Heating system: Capacity
17.0
c) Area
7c.
160.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
19.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 2908 AVE. Q City/FL Zip: FT. PIERCE, FL
8/15/2019 11:27:41 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1