Loading...
HomeMy WebLinkAboutEnergy CodeK=tMD AUG 2 s zozo FORM R405-2017 . FLORIDA ENERGY EFFICIENCY CODE Fdk%k=SIG CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KENNEDY GABRIEL Builder Name: Street: 2908 AVE. Q Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: KENNEDY GABRIEL Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1120.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 1120.00 ft2 b. N/A k= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1200.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1200.00 ft2 6. Conditioned floor area above grade (ft2) 1200 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(160.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C 6 175 a. U-Factor: Sgl, U=0.54 120.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.32 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 18.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.125 ft. Area Weighted Average SHGC: 0.262 14. Hot water systems 8. Floor Types (1200.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1200.00 ft2 b. Conservation features EF: 0.950 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 43.67 Glass/Floor Area: 0.133 PASS Total Baseline Loads: 44.02 1 hereby certify that the plans and specifications covered by Review of the plans and eii%E Sr'4?� this calculation are in compliance with the Florida Energy specifications covered by this y _ O� Code. calculation indicates compliance with the Florida Energy Code. PREPA BY: Before construction is completed DATE: - this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. G'OD WME OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an pnvelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). File Copy 8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KENNEDY GABRIEL Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1200 Lot # Owner Name: KENNEDY GABRIEL Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 2908 AVE. Q Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1200 9600 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 DINING 156 1248 No 0 1 Yes Yes Yes 2 LIVNG ROOM 340 2720 No 4 1 Yes Yes Yes 3 KITCHEN 80 640 Yes 0 1 Yes Yes Yes 4 LAUNDRY 24 192 No 0 1 No Yes Yes 5 BATH 2 54 432 No 0 1 No Yes Yes 6 BATH 1 63 504 No 0 1 Yes Yes Yes 7 BEDROOM 1 157 1256 No 1 1 1 Yes Yes Yes 8 BEDROOM 3 170 1360 No 1 1 1 Yes Yes Yes 9 BEDROOM 2 144 1152 No 1 1 1 Yes Yes Yes 10 A/C 12 96 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio DINING 25 ft 0 156 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio LIVNG ROOM 33 ft 0 340 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio KITCHEN 8 ft 0 80 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft 0 24 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 2 1 ft 0 54 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BATH 1 9 ft 0 63 ft2 _--- 0 1 0 ' 7 Slab -On -Grade Edge Insulatio BEDROOM 1 26 ft 0 157 ft2 ---- 0 1 0 8/15/2019 11:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio BEDROOM 3 14 ft 0 170 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio BEDROOM 2 25 ft 0 144 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio A/C 1 ft 0 12 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1300 ft2 0 ft2 Light N 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1200 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) DINING 0 Blown 156 ft2 0.1 Wood 2 Under Attic (Unvented) LIVNG ROOM 0 Blown 340 ft2 0.1 Wood 3 Under Attic (Unvented) KITCHEN 0 Blown 80 ft2 0.1 Wood 4 Under Attic (Unvented) LAUNDRY 0 Blown 24 ft2 0.1 Wood 5 Under Attic (Unvented) BATH 2 0 Blown 54 ft2 0.1 Wood 6 Under Attic (Unvented) BATH 1 0 Blown 63 ft2 0.1 Wood 7 Under Attic (Unvented) BEDROOM 1 0 Blown 157 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 3 0 Blown 170 ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 2 0 Blown 144 ft2 0.1 Wood 10 Under Attic (Unvented) A/C 0 Blown 12 ft2 0.1 Wood WALLS 9 Orrit Adjacent 10 Wall Typele Cavity ity Width Et In Height Et In Area Sheathing Framing RA/alue Erartion Solar Ahqor rr:ptlp% Below 1 NE Exterior Frame - Wood DINING 19 12 0 8 0 96.0 ft2 0 0.25 0.5 0 2 NW Exterior Frame - Wood DINING 19 13 0 8 0 104.0 ft2 0 0.25 0.5 0 3 SW Exterior Frame - Wood LIVNG ROO 19 16 0 8 0 128.0 ft2 0 0.25 0.5 0 4 NW Exterior Frame - Wood LIVNG ROO 19 17 0 8 0 136.0 ft2 0 0.25 0.5 0 5 NE Exterior Frame - Wood KITCHEN 19 8 0 8 0 64.0 ft2 0 0.25 0.5 0 6 NE Exterior Frame - Wood BATH 1 19 9 0 8 0 72.0 ft2 0 0.25 0.5 0 7 NE Exterior Frame - Wood BEDROOM 1 19 11 0 8 0 88.0 ft2 0 0.25 0.5 0 8 SE Exterior Frame - Wood BEDROOM 1 19 15 0 8 0 120.0 ft2 0 0.25 0.5 0 9 SW Exterior Frame - Wood BEDROOM 3 19 14 0 8 0 112.0 ft2 0 0.25 0.5 0 10 SE Exterior Frame - Wood BEDROOM 2 19 15 0 8 0 120.0 ft2 0 0.25 0.5 0 11 SW Exterior Frame - Wood BEDROOM 2 19 10 0 8 0 80.0 ft2 0 0.25 0.5 0 8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY iCI4FCKI IST RFPnPT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SW Insulated LIVNG ROO None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 NE 1 Vinyl NW 2 Metal SW 3 Metal NE 5 Metal NE 6 Metal NE 7 Metal SW 9 Metal SW 11 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes 0.32 0.3 N 40.0 ft2 11 ft 0 in 1 ft 4 in 0.54 0.25 N 30.0 ft2 12 ft 0 in 1 ft 4 in 0.54 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in 0.54 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in 0.54 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in 0.54 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in 0.54 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in 0.54 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None None None None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1120 61.49 115.63 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 18 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY r.WFCKI IST RFMIRT - ----------- DUCTS ---- ---- / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage A/C (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating Jan f X� Feb Mar ki Apr Ma rl Jun Jul ri Aug rl �XjSep �j 0 Nov Dec Jan [ ]Feb Mar Apr May Jun Jul Aug Sep Occt t Xj Nov DecVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVNG ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/s .ff. ft2 ft 0.3 A/C 8/15/2019 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: KENNEDY GABRIEL Builder Name: Street: 2908 AVE. Q Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: KENNEDY GABRIEL Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit Y pp 9 /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring, Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall gytgnd behind piping and woring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinklpr Cayff-plato ago walls or ceilings a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 8/15/2019 11:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location A/C 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 18.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1200 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.485 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.262 14. Heating system: Capacity 17.0 c) Area 7c. 160.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 19.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 2908 AVE. Q City/FL Zip: FT. PIERCE, FL 8/15/2019 11:27:41 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1