HomeMy WebLinkAboutProduct Approval (2) -(NIVEMO j etc.
6.4.1.3 ProEdge®:
Prevailing Standard I1„�
Wind Direction Fastening
Sealant Strip � Pattern
6°Exposure I.-
12' Sealant
Fasten 7'/i 17�= 6"Exposure
Cover Exposed I+ 1
Fasteners with
Roof Cement I_ 12„ ►f
Figure 21:Isometric View,Pro Edge Figure 22: Plan View,ProEdge
BUILDING7. •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
S. MANUFACtURING PLANTS'
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
tq Sectip(y 4 hPrsin fRf products and production locations having met codified material standards.
QUALITY9.
PRI Construction Materials Technologies,LLC—QUA9110; 813 621-5777;bwilson@pricmt.com
END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 10 of 10
NEMO I etc.
Certificate of Authorization rY32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-R29
1111 West Newport Center Drive FL5259-R33(NON-HVHZ)
Deerfield Beach, FL 33442 Date of Issuance:02/24/2009
(954)233-1330 Revision 29:04/07/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the Ph Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments,for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality
Assurance or production facility location(s) changes,or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 18.
Prepared by:
Robert J.M.Nieminen,P.E.
Florida Registration No.59166,Florida DCA ANE1983 ".aS;�; .�' The facsimile seal appearing was authorized by Robert Nieminen,P.E.on
04/07/2021.This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC,LLC
ONEMOletc.
rodu Material Standard - Plant(s) Description
4.15 Polystick IR-Xe ASTM D1970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.16 Polystick MTS Plus ASTM D1970 FL,NV, Nominal.60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 PA,TX membrane,glass fiber reinforced,surfaced with
polyolefinic film surface
4.17 Polystick MU-X ASTM D19701 FL,NV,PA Nominal 54-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polypropylene film surface
4.18 Polystick TU Max ASTM D1970 FL,PA,TX Nominal 60-mii thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane with a 190 g/mz polyester fabric surface
4.19 Polystick TU P FRSA/TRI 09-18 FL,PA,TX Nominal 130-mil thick rubberized asphalt waterproofing
membrane,glass-fiber/polyester reinforced,with a
granular surface
4.20 Polystick TU Plus ASTM D1970 FL,PA,TX Nominal,80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane,glass fiber reinforced,with a polyester fabric
surface
4.21 Polystick XFR ASTM D1970 NV,TX Nominal 80-mil thick rubberized asphalt waterproofing.
FRSA/TRI 09-18 membrane,glass fiber reinforced,surfaced with a
textured film surface
5.1 This is a Building Code Evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for
any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
1 Polystick MU X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard
laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance,
MEMO ETC,U.C. Evaluation Report P32060.02.09-R29
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.5259-1133(NON-HVHZ)
Polyglass Roof Undeflayments Revision 29:04/07/2021
Page 4 of IS