Loading...
HomeMy WebLinkAboutAPPROVED, Lucita Dover_07-02-2021_Planset - (Electrical) signed4.32 KWSYSTEM SIZE :5.76 KW DC STCVICINITY MAPSITE MAP (N.T.S)A-01SITE MAP &VICINITY MAPLUCITA DOVERNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (5.76 KW)33°C0°C0 PSF160MPH (ASCE 7-16)IIB18 A(18) ENPHASE IQ7-60-2-US MICROINVERTERSBACKFEED BREAKER IN THE MSPWIND FLOW MAP(2) BRANCHES OF 09 MODULESSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINT OF CONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILSGOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)NATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70SITE MAP & VICINITY MAPA - 01A - 02S - 01ELECTRICAL LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILINVERTER DATASHEETCOMBINER BOX DATASHEETATTACHMENT DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTSITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORY(18) HANWHA Q.PEAK DUO BLK-G5 320WMODULESRACKING DATASHEETDS - 05DRIVEWAY131'-3"73'-10"131'-3"73'-10"12'-6"24'-10"3'-2"77'-10"MSPUM(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(OUTSIDE HOUSE)PV ARRAYROOF 1(E) SERVICE DROPFORT WALTON AVE18" SETBACK3' SETBACK NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURERAND MODEL NUMBER, INVERTER MANUFACTURER AND MODELNUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.E-01SINGLELINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.SOLAR ARRAY (5.76 KW-DC STC)(18) HANWHA Q.PEAK DUO BLK-G5 320W MODULES(2) BRANCHES OF 09 MODULESINVERTER SPECIFICATIONSMANUFACTURERENPHASEMODEL NO.IQ7-60-2-USMAX DC INPUT VOLTAGE48 VMAX OUTPUT POWER240 VANOMINAL AC OUTPUT VOLTAGE240 VNOMINAL AC OUTPUT CURRENT1 AMODULE SPECIFICATIONMODEL NO.HANWHA Q.PEAKDUO BLK-G5 320WPEAK POWER320 WRATED VOLTAGE (Vmpp)33.80VRATED CURRENT (Impp)9.47 AOPEN CIRCUIT VOLTAGE (Voc)40.56VSHORT CIRCUIT CURRENT (Isc)9.94AGJUNCTIONBOX1 STRING OF9 MODULES WITHMICROINVERTERS1 STRING OF9 MODULES WITHMICROINVERTERS20A/2P20A/2PGENPHASE IQ ACENVOY IQ10A/2PCOMBINER PANELUMGNG30A30AAC DISCONNECTUNFUSED150AMAIN SERVICE PANEL120/240V150A(3) #10 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(2) #10 AWG THWN-2 - L1(2) #10 AWG THWN-2 - L2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNENPHASEQ CABLESINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED150A + 30A = 180 ABUSS RATING x 120%150A x 120% = 180ABACKFEED BREAKER ELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR75 DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.144. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5. WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).E-02WIRINGCALCULATIONSMAX VOLTAGE DROP CALCULATIONCABLE SIZECABLE DESCRIPTIONONE WAYDISTANCE INFEET (D)BRANCHCURRENT (I)RESISTANCE OFCONDUCTOR(R)VOLTAGE (V)% VOLTAGEDROP=(0.2*D*I*R)/V#10 THWN-2JUNCTION BOX TOCOMBINER PANEL20181.242400.37SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.ELECTRICAL CALCULATIONS:1.CURRENT CARRYING CONDUCTOR(A)BEFORE IQ COMBINER PANELAMBIENT TEMPERATURE = 33°CCONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a)GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY= (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)= [(9 x 1) x 1.25] / 0.96 / 0.8= 14.65 ASELECTED CONDUCTOR - #10THWN-2 ...NEC 310.15(B)(16)(B)AFTER IQ COMBINER PANELTEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(18x 1) x 1.25] /0.96 / 1=23.44 ASELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.15(B)(16)2.PV OVER CURRENT PROTECTION ..NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25=(18 x 1) x 1.25 = 22.5 ASELECTED OCPD = 30ASELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #10 THWN-2 ... NEC 250.122(A) WARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 18 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGNOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATINGFOR AC MODULE PROTECTION PER CIRCUIT-240240120VVA 60 HzAAINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICEPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDE-03WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING PHOTOVOLTAICPOWER SOURCE!727-571-4141EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSSHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.SYSTEMLABELINGLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION, COMBINER PANEL(PER CODE: NEC 690.13(B))LABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54)LABEL LOCATION:CONDUIT RUNWAY(PER CODE: NEC690.31(G)(3)(4))LABEL LOCATION:MAIN SERVICE DISCONNECT(NEC 705.12(B)(3-4) & NEC 690.59)ADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, ANDLOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1)·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED. NEC 110.21(B)(3)·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3LABEL LOCATION:COMBINER PANEL, AC DISCONNECT(PER CODE: NEC 690.52)LABEL LOCATION:POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT(PER CODE: NEC 705.12 (B)(2)(c))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]DATA PER PANELLABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C)(3))IFC 605.11.3.1(1) & 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the array DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG. DS-02DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG. DS-03DATASHEETCOMBINER BOXSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.