Loading...
HomeMy WebLinkAboutAPPROVED, Lucita Dover_07-02-2021_Planset - (Structural)(1)4.32 KWSYSTEM SIZE :5.76 KW DC STCVICINITY MAPSITE MAP (N.T.S)A-01SITE MAP &VICINITY MAPLUCITA DOVERNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (5.76 KW)33°C0°C0 PSF160MPH (ASCE 7-16)IIB18 A(18) ENPHASE IQ7-60-2-US MICROINVERTERSBACKFEED BREAKER IN THE MSPWIND FLOW MAP(2) BRANCHES OF 09 MODULESSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINT OF CONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILSGOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)NATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70SITE MAP & VICINITY MAPA - 01A - 02S - 01ELECTRICAL LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILINVERTER DATASHEETCOMBINER BOX DATASHEETATTACHMENT DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTSITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORY(18) HANWHA Q.PEAK DUO BLK-G5 320WMODULESRACKING DATASHEETDS - 05DRIVEWAY131'-3"73'-10"131'-3"73'-10"12'-6"24'-10"3'-2"77'-10"MSPUM(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(OUTSIDE HOUSE)PV ARRAYROOF 1(E) SERVICE DROPFORT WALTON AVE18" SETBACK3' SETBACK A-02 & MODULESROOF PLANMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3.BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS, AND EQUIPMENT DEAD LOADS. *GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLEDAS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WINDZONE:.WIND ZONE 1: MAX SPAN 4'-0" O.C.WIND ZONE 2: MAX SPAN 4'-0" O.C.WIND ZONE 3: MAX SPAN 2'-0" O.C.2) EXISTING RESIDENTIAL BUILDING ROOF WITH MEAN ROOFHEIGHT 15 FT AND 2"x4" WOOD ROOF TRUSSES SPACED 24" O.C.CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANSAND IN FIELD CONDITIONS.LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT- PRODUCTION METER- MAIN SERVICE PANEL- VENT, ATTIC FAN (ROOF OBSTRUCTION)- JUNCTION BOXCP- COMBINER PANEL- CONDUIT- MICROINVERTER- FIRE SETBACKNUMBER OF MODULES = 18 MODULESMODULE TYPE = HANWHA Q.PEAK DUO BLK-G5 320W MODULESWEIGHT = 41.22 LBS / 18.7 KG.MODULE DIMENSIONS = 66.33" X 39.37" = 18.13 SFNUMBER OF INVERTER = 18 MICROINVERTERSINVERTER TYPE = ENPHASE IQ7-60-2-US MICROINVERTERSDC SYSTEM SIZE: 5.76 KWAC SYSTEM SIZE: 4.32 KWNOTES:1. LOCATION OF JUNCTION BOX(ES), ACDISCONNECTS(S), AC COMBINER PANEL(S), ANDOTHER ELECTRICAL EQUIPMENT(S) RELEVANT TOPV INSTALLATION SUBJECT TO CHANGE BASEDON SITE CONDITIONS.2. SETBACKS AT RIDGES CAN BE REDUCED TO 18INCHES IN COMPLIANCE WITH FBC R 324.6.2:TOTAL PLAN VIEW AREA = 1901.1 SQFTTOTAL PV AREA = 18(66.33 IN)(39.37 IN)/(144 IN^2) = 326.43 SQFT( 326.43 SQFT/ 1901.1 SQFT)100 = 17.17 %TOTAL PV AREA POPULATES 17.17 % OF TOTALPLAN VIEW AREA AND IS WITHIN THE 33%REQUIREMENT.M- METER MAIN COMBOMSPUM(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(OUTSIDE HOUSE)PV ARRAYROOF 1(E) SERVICE DROPACDCP(N) AC DISCONNECT(N) COMBINER PANELROOF ACCESS POINTJB18" SETBACK(E) FRONT YARD(E) BACK YARDCONDUIT RUNROOF ACCESS POINT3' SETBACKThis item has been electronically signed and sealed by Vincent Mwumvaneza using a Digital Signature and Date.Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Exp:02/28/2023 STRUCTURAL ONLY S-01ARRAYLAYOUT(ROOF #1)ROOF DESCRIPTION:SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.MODULES - 18ROOF TILT - 18°ROOF AZIMUTH - 180°TRUSSES SIZE - 2"X4" @ 24" O.C.WIND LOAD INFORMATION:THIS SYSTEM HAS BEEN DESIGN TO MEETTHE REQUIREMENTS OF THE 7TH EDITION OFTHE FLORIDA BUILDING CODE AND USED THE FOLLOWING DESIGN PARAMETERS: ULTIMATE WIND SPEED: 160 MPHEXPOSURE CATEGORY: BRISK CATEGORY: IIMEAN ROOF HEIGHT: 15 FEETROOF SLOPE: 7-20°LEGENDS- VENT, ATTIC FAN (ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- RAFTERS / TRUSSES- FIRE SETBACKWIND ZONE 1- WIND ZONE 1- WIND ZONE 1'WIND ZONE 2- WIND ZONE (2)- WIND ZONE (2r)- WIND ZONE (2e)- WIND ZONE (2n)WIND ZONE 3- WIND ZONE (3)- WIND ZONE (3r)- WIND ZONE (3e)- RAIL- METAL SEAM58'-4"10'10'-10"7'-1"44'-5"7'-10"18" SETBACKSOLAR MODULEROOF #13' SETBACKThis item has been electronically signed and sealed by Vincent Mwumvaneza using a Digital Signature and Date.Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Exp:02/28/2023 STRUCTURAL ONLY PHOTOVOLTAIC MODULE GENERAL NOTES:1. APPLICABLE CODE: 2020 FLORIDA BUILDING CODE 7th ED. & ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A WOOD ROOF TRUSS AS EMBEDMENT MATERIAL.3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO AMAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOTEXCEED 30'-0" MEAN ROOF HEIGHT.4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511.5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TOMANUFACTURERS' MANUAL FOR ALL ARCHITECTURAL, MECHANICAL,ELECTRICAL, AND SOLAR SPECS.6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESSOTHERWISE NOTED.7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.8. ALL RAILING AND MODULES SHALL BE INSTALLED PERMANUFACTURERS' INSTRUCTIONS.9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCEWITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATEDWIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS.S-02STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.SOLAR MODULE5/16"x4" STAINLESSSTEEL LAG SCREWWOOD SHEATHINGRAFTERSRAFTERSWOOD SHEATHINGQUICK MOUNT QRAIL LITEL FOOTRT MINI BASEQUICK MOUNT QRAIL LITE L FOOTRT MINI BASEThis item has been electronically signed and sealed by Vincent Mwumvaneza using a Digital Signature and Date.Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Exp:02/28/2023 STRUCTURAL ONLY DS-04DATASHEETATTACHMENTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG. DS-05DATASHEETRACKINGSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROCS07/02/2021DESIGNERREVIEWERDATELUCITA DOVER 8403 FORT WALTON AVE,FT PIERCE, FL 34951, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.