Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 6 Block 1 Waterstone 1820 ATGGL Builder Name: ADAMS HOMES Street: 5436 Lugo Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO: INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV120.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul,.Exterior R=4.1 1785.00 ft2 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 65.00 ftZ 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 1.1. Ceiling Types (1900.0 sgft.) Insul.1tion Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7: Windows(239.3 scift.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 364 a. U-Factor: Dbl, U=0.33 136.36 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 -c.. U-Factor: Dbl, U=0.30 32.38 ft2 3 SHGC: SHang Area Weighted Average Overhang Depth: 4.251 ft. . 14Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.269 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1820.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 59.57 A SS Total Baseline Loads: 64.64 !�1 I hereby certify that the plans k0fications covere Revs of the plans and this calculation are in comp' n o nergy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 04-18-9091 Winn KPnmany this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Code.'OD OWNER/AGED_ . _ BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance•with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/16/2021 4:13 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CI4F[.KI IST RFPnRT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 6 Block 1 Waterstone 182 Bedrooms: 4 User Conditioned Area: 1820 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Street Address Lot # 6-1 Block/Subdivision: Waterstone PlatBook: Street: 5436 Lugo Street County: St. Lucie City, State, Zip: Fort Pierce , FL , 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft' ---- 0.42 0 0.58 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ftz 456 ftZ Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Blown 1820 ftz 0.11 Wood 80 ftz 0.11 Wood 4/16/2021 4:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ftz 0 0 0.6 0 2 NW Exterior Concrete Block - Int Insul Main 4.1 13 6 10 0 135.0 ftz 0 0 0.6 0 3 SW Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ftz 0 0 0.6 0 4 SE Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ftz 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ftz 0 0.23 0.01 0 6 NW Exterior Frame - Wood Main 13 6 . 6 10 65.0 ftZ 0.23 0.6 0 V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None z5 3 6 8 20 ftz 2 - Wood Main None .25 2 8 6 8 17.8 ftz WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ftz 1 ft 4 in 0 ft 10 in None Exterior 5 2 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ftZ 1 ft 4 in 0 ft 10 in None Exterior 5 3 NW 6 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ftz 9 ft 4 in 0 ft 0 in None None 4 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ftz 1 ft 4 in 1 ft 0 in None None 5 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft' 1 ft 4 in 1 ft 0 in None Exterior 5 6 NW 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft' 9 ft 4 in 1 ft 6 in None None 7 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ftZ 1 ft 4 in 0 ft 10 in None Exterior 5 8 SE 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft' 12 ft 0 in 0 ft 6 in None None 9 SE 4 Vinyl Low-E Double Yes 0.3 0.23 N 32.4 ft' 1 ft 4 in 0 ft 10 in None Exterior 5 10 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftz 12 ft 0 in 0 ft 6 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 596 ftz 596 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 4/16/2021 4:13 PM EnergyGauge®' USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPC]RT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS ---- Supply ---- V # Location R-Value Area --- Return ---- Location Area Leakage Type Air Handler CFM 25 CFM25 TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 364 ftz Main 91 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Coolin Jan ]Feb Heating X Jan lX] Feb Ventin Jan [ ] Feb Mar X Mar X Mar Ceiling Fans: Jul f APr [ ]May f Jun Jul A r [ ] Ma X Jun rl [X] A r [ ] Ma [ Jun Jul AuSep rl Aug Aug Se rl Se [X] Oct Oct Oct Nov Nov HX Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM Cooling (WEH) AM PM Heating (WD) AM PM Heating (WEH) AM PM 78 80 78 78 66 68 66 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 4/16/2021 4:13 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case?. 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=D.21 c. U-Factor: Dbl, U=0.30 SHGC: SHGC=0.23 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 5436 Lugo Street, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1785.00 ft2 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 - 1 c. Frame - Wood, Exterior R=13.0 65.00 ft2 4 d. N/A R=. ft2 11. Ceiling Type and insulation level Insulation . Area No a. Under Attic (Vented) R=30.0 1820.00 ft2 1820 b. Knee Wall (Vented) R=19.0 80.00 ft2 Area c. N/A R= ft2 136.36 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 364 32.3.8 ft2 13. Cooling systems kBtu/hr Efficiency 32.38 ft2 a. Central Unit 35.0 SEER:16.00 38.19 ft2 a 14. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.6 HSPF:8.50 4.251 ft. 0.269 Area 15. Hot water systems ft2 a. Electric Cap: 40 gallons EF: 0.94 b. Conservation features Insulation Area None R=0.0 1820.00 ft2 Credits (Performance method) Pstat R= ft2 R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home'before final inspection. Otherwise, a new.EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/16/2021 4:13 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1