Loading...
HomeMy WebLinkAboutBuilding PlansX 3, ABBREVIATIONSAND/OR LEGEND: C.B.S. = CONCRETE BLOCK STRUCTURE EL = ELEVAT701V LB. = LICEENCED BUSINESS ID = IDEN77FICA77ON NA VD = NORTHAMERICAN VERTICAL DATUM NO �N SPOTELEVATION N, 2L GRAPHIC SCALE ( IN FEET ) 1 inch = 20 1t. LEGAL DESCRIPTION; BEINGALL OF LOT 8, OFPELICAN POINTS REST, ACCORDING TO THEPLAT THEREOFAS RECORDED IN PLATBOOK40, PAGES 35 AND 354 OF THE PUBLIC RECORDS OFST. LUCIECOUNTY, FLORIDA. SURVEYOR'S NOTES 1. NOATTEMPTWAS MADEBY THIS FIRM TQLOCAIE UNDERGROUND UTILITtS ON/ORADJACENT TO THIS SITE. THEAPPROWMATE LOCATION OFALL UTILITIES SHOWN HEREON WERE TAKEN FROMASSUILTDRAW/NGSAND/OR ON-SITELOC477ONAND SHOULD BE VERIFIED BEFORE CONS7RUC77ON. 2. NO ATTEMPT WASMADEBY7HIS FIRM TOLOCATEUNDERGROUND F0077NGS OF BUILDINGS OR FENCES ON OR ADJACENT TO / THISSITE 3. LANDS SHOWN HEREON WERE NOTAXTRACTED FOR 64SEMENTSANDA)R RIGHTS OF WA Y OF RECORD EXCEPTAS SHOWN ON 7HERECORDPLATIFANY. 4. THISPROPER TYWAS SURVEYED W THOUT THE BENE FIT OF A 777LESEA RCH. 5 7HEBEARINGBASEOF7HlSSURVEYISALONGTHE SQUTHWESTERLYRIGHTOFWAYLINEOFPF_LICANPOINTEDRIVE, S24°32b0"E. 6. ALL BEAPJNGS AND DIS TANCES SHOWN ARE PLATAND MEASURED UNLESS 0THERWISEN07ED. 7. ADDI77ONS OR DELETIONS TO SURVEY MAPS OR REPORTS B Y 0 HER THAN THE SIGNING PARTY OR PAR TIES ISPROHIB17ED W77HOUTWRITTEN CONSENT OF7HESIGNING PAR TYORPARTIES. / 8. 0ITEAREA:11546.44 SQUAREFEETAND/OR 0.27ACRES+/ 9. THEE(PECTED USEFOR THISSURVEYAND MAPISFORRESIDEN77AL PURPOSES 10. ALL MEASUREMENTSAREINACCORDANCEWITHTHE UNfTED STATES STANDARD, INFEST. 11, THIS SITE HAS PUBLIC WATER AND SEWER 12, ALL ELEVATIONS SHO WY ARE BASED ON NORTH AMERICA N VER77CAL DATUM 1988 (NAVD 88) 4.�/� / A NOTE. MHWL (MEAN HIGH WATERLINE) THfS SURVEY DOES NOT ESTABUSH THE MEAN HM WATER LWE BEWO THE BOLWDAft1 OF THE PMAiE L PLAND OMER AND THE SOVEREIGN STATE SUBMERGED LANDS. THE UNDERSIGNHASESTABLISHEDA MEANHIGH W47ERLINEACCORDING TO THE UNDERLYING PLATAND WAS NOT CONTRACTED TO ESTABLISHA NEWMEANHIGHWA7ERLINE FLOOD ZONE NOTE.' LANDS SHOWN HEREONARE LOCATED W 714INANAREA HAVINGAZONEDESIGN471ON OF XAND'AE'BASEEL 5.0'BY7HEFEDERAL EMERGL-7VCYMM4GEMENTAGENCY(FEMA), ONFLOODINSURANCERATFMAPNO. 12111CM-K DA 7ED FEBRUARY 19, 2020AND ISRELA17VE70 7HENORTHAMER/CAN VER77CAL DA7UM 1988. THIS SITEALSO LIES INA COASTAL BARRIER RESOURCESYS7EM AREA. SURVEYOR'S CERTIFICATION.' 1 HEREBYGER77FYTHAT THIS SURVEYMAPANDIOR REPORTWAS PREPARED UNDERMYRESPONSIBLECHARGEAND MEETS THE STANDARDS OFPR4C77CEAS SETFORTH BY 7HEFLORIDA BOARD OFPROFESSIONAL SURVEYORS AND MAPPERS INCHAPTSRW-1T, FLORIDA ADMINISTWIVE CODEAND THATITIS 7RUEAND CORRECT TO 77fEBEST OFMYKNOWLEDGEAND BELIEF. SURVEYMAP AND REPORT OR THE COPIES 7HEREOFARENOT VALID WITHOUT 7HE SIGNATUREAND 774E ORIGJNAL RAISED SEAL OFA FLORIDA LICENSED SURVEYOR AND MAPPER. CRAI . WATSON PROFESSIONAL SURVEYORS MAPPER NO. 5647STATE OF FLORIDA � 3Q Go v� � 0 G� � Oro LL w o Q�OJ >k. ®ail ��_ �.W� �., Qcq Lu U W0 �Qm W 04� w 6,03 OJ DATE REVISIONS DATE: 5221 SCALE.' 1"= DWNG. BY C.D.W CHECKEDBY• CAW.' JOB NUMBER: 21124 SHEETNUMBER OF IN FIRST FLOOR PLAN SCALE- 1/4" = 1'-0" SECOND FLOOR PLAN SCALE- 1/4" = 1'-0" R G �• V Goo4GG �G v 9*1 6o fuf "\&'suMM11 DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 66080 J. EN e .. t; 080 - ' 1r TATE OF /44t H z 0 0 a a z w H Q � w Q z z Q ro H Q z 0 c^ w x DATE DESIGNED BJM 02-23-21 DRAWN NUN 02-23-21 CHECKED JOB NO. 2021-062 Aml GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the Building Department and the building permit has been issued. THRESHOLD NOTE At egress door (Entry Door) the max. hgth. of the threshold shall be 1/2" BUCK ATTACHMENT NOTES AT DOORS USE 2XP.T. PINNINND ATTACH BUCKS TO BLOCK WITH 1/4" DIA. TAPCONS WITH 2 1/4" EMBEDMENT INTO C.B.S. SET A 6" FROM CORNERS AND AT 8"o.c. MAX. STUCCO CEMENT FINISH CMU W ATER RES 1 S TANT C (SEE WATERPROOFING NC CORROSION RESISTANT FLASHING PER WATERPRO NOTE #2 APPLY PERIMETER CAULK SEALANT BETWEEN BUCK WINDOW FRAME (SEE WATERPROOFING NOTE # FILLED CELL AT JAMB BLOCK (T1P) 1 x3 P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS 2x6 OR 2x8 WOOD BUCK W/(2) 1/4"x3-1/4" TAPCONS @ S' O.C. W/SEALANT PER WATERPROOFING NOTE #4 AND ANCHORED TO MASONRY. SEE WATERPROOFING NOTE # 6 ANCHOR DOOR JAMB HEADER TO NOTE. WINDOW FRAME SHOCLD BE MASONRY IN STRICT COMPLETELY SEATED ON BUCK IN NO ACCORDANCE WITH INSTANCE SHALLTHE FRAME OVERHANG MANUFACTURERS PRODUCT THE BUCK. APPROVAL INSTALATI ON REQUIREMENTS EXTERIOR DOOR BUCK DETAIL NOT TO SCALE 1 x 4 bottom chord brocina 24" IT truss 8" x 16" C.M.U. WITH CELLS FILLED WITH GROUT & #5 VERT. DOWEL P.T. 2 x 6 AT (3) SIDES OF OPENING, FASTEN TO BLOCK AS NOTED. DOOR SIDES 1/2" x 6" REDHEADS WITH MIN. 2" x 1/8"WASHER 12" FROM ENDS AND 24"o.c. MAX. "OR" 518" x 6" REDHEADS WITH MIN. 2 x 1/8"WASHER 12" FROM ENDS AND 28"o.c. MAX. "OR" 1/4"xl-1/4"TAPCON MIN EMBEDMENT SPACED 0 7-1 2" O.C. W/1" O.D. WASHERS SPACE BOTTOM ANCHOR 0 3-1/2" FROM BOTTOM OF 2x6 & TOP ANCHOR AT LEAST AS HIGH AS THE DOOR OPENING DOOR HEAD 1/4" x 2 3/4" TAPCONS STAGGERED 24" o. c. Garage Door Buck Detail corner bars at beam — (outside only) (2) corner bars at footing (min.) vert. dowel lapped with wall reinforcing, all laps 25" (min.) in grout filled cell all corner bars to be the same size, number, and spacing as horizontial bars in footing, beams, and walls Corner Reinforcina Detai AT WINDOWS USE 1X P.T. PINE AND ATTACH CBS BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS 3/8" continuous bead of OR T NAILS 4" FROM ENDS AND 12"o.c. bottom chord of caulk (back bedding) behind "STRUCTURAL" buck to prevent liquid passage USE SHIMS DURING DOOR INSTALLATION awtoo2d4trrucsses Min. 1 1/4" embedment WOOD AND/OR CEDAR SHIMS SHALL NOT BE USED. v t ows and set flange in continuous a 1 1%2d " embedmental, bead of caulk across the a a a sl. gl. doors EXTERIOR CEILING & SOFFIT NOTE entire face of buck d. 7/8" Stucco finish over 3/8" high ribbed galy. wire lath fastened to a e framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" A. . dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c. /2" drywall Provide one layer of 15# felt to bottom of framing before installing loth. I I �1 2111060110 Wall and ceiling finishes shall comply with 302.9 of the 2020 Florida Residential Building Code. Wall and ceiling finishes shall have a flame spread index of not greater than 200. Wall and ceiling finishes shall have a smoke developed index of not greater than 450. Insulation shall comply with 302.10 of the 2020 Florida Residential Building Code. Insulation materials shall have a flame spread index not to exceed 25 with an accompanying smoke developed index not to exceed 450. Gypsum board materials shall comply with 702.3.1 of the 2020 Florida Residential Building Code. Gypsum board materials shall conform to ASTM C22, C475, C514, C1002, C1047, C1177, C1178, C1278, C1396 or C1658. Adhesives shall conform to ASTM C557. Ceramic tile shall conform with 702.4 of the 2020 Florida Residential Building Code. Ceramic tile shall be installed in accordance with ANSI A108.1, A108.4, A108.5, A108.6, A108.11, A118.1, A118.3. A136.1 and A137.1. Fiber —cement, fiber mat reinforced cementitious backer units, glass mat gypsum backers or fiber reinforced gypsum backers in compliance with ASTM C1288, C1325, C1178 or C1278, respectively, and installed in accordance with manufacturer's recommendations shall be used as backers for wall tile in tub and shower areas and wall panels in shower areas. WATERPROOFING NOTES: 1. PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER RESISTANT COATING TO SEAL THE WINDOW/ DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. THE APPLICATION OF THE CMU WATER RESISTANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE OPENING ( SILLS, .IAMBS, HEAD ). ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO BUCK INSTALLATIONS. 2. INSTALL BUCKS SO THAT THERE ARE, NO EDGE GAPS EXCEEDING 1/ 8" BETWEEN BUCK AND MASONRY. 3, PRIOR TO BUCK INSTALLATION APPPLY 1/ 3" NOMINAL DIAMETER BEAD OF SEALANT BETWEEN BUCK AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT'rHE PASSAGE OF LIQUID THROUGH THE CUT ENDS AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHALL BE COATED WITH A LIQUID APPLIED WATER RESISTIVE COATING/ SEALANT. 4. PROVIDE PAN FLASHING AT SILL OF WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILL AS WELL. PAN FLASHING SHALL BE CORROSION RESISTANT, (NOT REQUIRED/ OPTIONAL) 5. PROVIDE CONTINUOUS 3/ 8" BEAD OF SEALANT ON WINDOWS/ DOOR FRAMES AT ALL PERIMETER ON FRONT AND BACK SURFACE PRIOR TO WINDOW/ DOOR INSTALLATION. 6. AFTER WINDOW/ DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRE CAST SILL) AND THE WINDOW/ DOOR TO ENSURE A WATER RESISTANT INTERIOR AIR SEAL AROUND THE ENTIRE PERIMETER. 7. WATERPROOFING TO COMPLY WITH FBC R703.4. Bottom Chord Lateral Bracing manufactured ar/roof trusses -0" o.c. drywall cieling 4 galvanized metal track or 4 top plate drywall both sides 4 metal studs or 2x4 wood ids spaced 0 24" o.c. Iseboard (typ.) :4 galvanized track or 2x4 )ad p.t. bottom plate thick concrete slab (2500 psi) with fiber mesh over vapor barrier over clean compacted termite treated soil TYP INTERIOR NON LOAD BEARING WALL SECTION J"=1' SCALE stucco finish—� perimeter caulk Attach p.t. bucks with 8d coil nails at 12"o. c. Typ. Alum. window — jamb or sliding glass door jamb - 1/4" max. struct. shim caulk attach as per manufacturers product approvals NOTE: Method of attachment and waterproofing procedures are the same at poured concrete sill. Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction Typical Window & S.G.D. Jamb Detail at CBS Wall Includes Buck Attachment Method DESIGNED TO MEET THE REQUIREMENTS OF FBC 2020 SECTION R703.4 "FLASHING" Alum. window frame 3/8" continuous bead of — caulk (back bedding) behind shim to prevent liquid passage 1/4" struct. shim set flange in continuous — bead of caulk across the entire face of buck perimeter caulk stucco finish — corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval d Note: Provide double bond beam beam below precast sill. G Provide #5 each bond beam and extend bars 8" into jambs. tunable sealants shall comply with a See structural notes. ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction precast cone. sill Typical Precast Conc. Sill Detail SUMMII DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 66080 z z 0 � a U Q H "ate w Q c� z Q w W N Q � z 0 5 w a 00 �rTJ ZU C) Iw^o 3-4 F� U O W DATE DESIGNED BJM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 A=7 ILE COPY PARAPET WALL (TYP.) MOD BIT ROOF SYSTEM. (TYP.) ROOF ACCESS HATCH ORF].O W CU S CUPPIiR (TYP.) PRIMARY SCUPPER " PER FT. MIN. SCUPPER BOX & DOWNSPOUT (TYP.) MOD BIT ROOF PRIMARY SYSTEM. (TYP.) RIDGE LINE SCUPPI�R BOX & DOWNSPOUT (TYP.) E—/i" PER FT. MIN. O VERFLO W SCUPPER (TYP.) I CRICKET (TYP.) PARAPET WALL (TYP.) ROOF PLAN SCALE- I/4" = V-0" SUMMII DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 66080 �Q- . v\GEN 660 . c1g z O a a u w ra H z 0 5 w a DATE DESIGNED BJM 02-23-21 DRAWN NUN 02-23-21 CHECKED JOB NO. 2021-062 FRAME W/ CAPFLASHING (CORNERS FULL WELDED) FLASHING W/ CANT STRIP - MOD BIT ROOF SYSTEM 5 ' PLYWOOD - ANCHOR PER - MANUFACTURER'S SPECIFICATIONS GASKET (ALL AROUND PREPARED TO RECEIVE SECURITY LOCK (CONSULT FACTORY FOR AVAILABLE LOCK CONFIGURATIONS) COVER LINER ARM GUIDE BRACKET RED VINYL GRIF HOLD OPEN ARM STRIKE =111111:111E ROOF HATCH DETAIL I"= r-o" U 24"X36" DOOR HATCH ' 1" [25] THICK FIBERGLASS COVER INSULATION HEAVY DUTY MANGANESE BRONZE HINGES SPRING LIFTING MECHANISM 7T25] RIGID FIBERBOARD INSULATION - (2)-2X12 BLOCKING ROOF FRAMING PLAN SCALE- 1/4" = F-0 BEAM ELEVATION REFERENCED FROM �UMN MARK. SEE COLUMN SCHEDULES ON .. L�. M MARK SEE BEAM SCHEDULE ON SHEET S.7. L1 = PRECAST LINTEL SEE LINTEL SCHEDULE ON SHEETS-7. G.T. = PRE-ENGINEERED WOOD GIRDER TRUSS. O - CONNECTOR. S EE S CHEDULES ON S HEET S - 7. = DOWEL MAS ONRY WALL TO CONCRETE COLUMN W/ #3xF-0" LNG. DOWEL EPDXIED 6" INTO EXISTING SPA. @ V-4" O.C. THIRD FLOOR WALL PH I CELLS SHOWN. Mr SUMMII DESIGN & FORENSICS, INC. 725. SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 I BRIAN J. MASKOL FL PE # 66080 6y JJ g OF lJJ i OR10?Cy��e� rr�,?/O N A1. z z 0 a o U WW FF�Y,, W A z Q w N- Q � z w� ai i 00 Oo a w �w r O as UO W a DATE DESIGNED BJM 02-23-21 DRAWN NUN 02-23-21 CHECKED JOB NO. 2021-062 AIL WINDOWS TO HAVE BLINDSPAC F_ ELECTRIC BLINDS CEILING MOUNTED. PRE -WIRE. COORDINATE LOCATIONS WITH OWNER. FIRST FLOOR ELECTRICAL PLAN SCALE- 1/4" = V-0" Meter ation to be Determined ground Service ELECTRICAL LE FAN OUTLET QVP VAPOR PROOF SURFACE MOUNTED LIGHT TO FAN OUTLET EXTWF GH EXTERIOR UGHT WALL FIXTURE ® RECESSED LED LIGHT OFLUORESCENT FIXTURE INCANDESCENT LIGHT Rff FIXTURE WITH EXHAUST FAN ❑O EXHAUST FAN OUTLET k DUPLEX OUTLET 220 V OUTLET GROUND FAULT INTERRUPTER WFI WEATHER PROOF GROUND FAULT "S CARBON/SMOKE DETECTOR C SWITCH 3 WAY SWITCH p PUSH BUTTON NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT. SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS CEILING FAN WITH LIGHT SECOND FLOOR ELECTRICAL PLAN SCALE- 1/4" = 1'-0" SUMMII DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 66080 H z 0 0 a z z w F ra � a w Q z z w H Q z 0 5 w a DATE DESIGNED BIM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 Eml DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MAS KOL FLPE#66080 MA �r � EOF :4U ZZ t�il00 H z 0 0 a � a z w H Q � w Q O z Q ro H Q z 0 r w a DATE DESIGNED BJM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 E=2 ,,SUMMII DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE PL34984 (772)295-0572 BRIAN J. MASKOL FL PE # 66080 \ \�e I nn q Zr \GEN SS N .66080' -0 TAT k/ zz ✓ � C9 \ AL `111)Gllltl� bl Z� H z 0 0 a z L w H Q w q z z ro H Q z 0 5 w a m We 01 B DATE DESIGNED BJM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 CU-1 CU-2 MINI -SPLIT 1 MINI -SPLIT 2 THIRD FLOOR MECHANICAL PLAN SC,.9LE- 1/4" = 1'-0" CONDENSING UNIT SCHEDULE: MANUFACTURER MODEL NO. AMBIENT TEMP. TONNAGE I POWER M.C.A. M.O.C.P.1 WEIGHT I NOTES MITSUBISHI MXZ-5C42NA2 MITSUBISHI MXZ-3C30NA2 MINI -SPLIT UNIT SCHEDULE: MANUFACTURER MODEL NO. NOM. CFM I KW I POWER M.C.A. M.O.C.P. WEIGHT I NOTES MITSUBISHI MSZ-GL09 MITSUBISHI MSZ-GL12 MECHANICAL NOTES FURNISH AND INSTALL MECHANICAL SYSTEMS TO MEET ALL CURRENT REQUIREMENTS OF NATIONAL, STATE AND MUNICIPAL CODES, RULES, REGULATIONS, LAWS, ANP STANDARDS AS THEY ARE ADOPTED BY THE GOVERNING AGENCY AND AS THEY MAY APPLY. THE MECHANICAL WORK INDICATED ON THIS PLAN SHALL COMPLY WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODES: RESIDENTIAL, BUILDING, MECHANICAL, PLUMBING, ACCESSIBILITY, ENERGY CONSERVATION, THE FLORIDA FIRE PREVENTION CODE, UNDERWRITERS LABORATORIES (UL) AND THE STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATION SYSTEMS, NFPA 90A. SECURE AND PAY FOR ALL PERMITS AND LICENSES BEFORE ACTUAL WORK IS STARTED AND OBSERVE ANY REQUIREMENT STIPULATED THEREON. COORDINATE WITH AND GIVE ALL NECESSARY NOTICES FOR INSPECTION OF THE WORK TO THE GOVERNMENTAL AUTHORITY HAVING JURISDICTION. COORDINATE LOCATION OF AIR DEVICE WITH ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED CLEARANCE TO SMOKE DETECTORS. CONSTRUCT DUCT IN ACCORDANCE WITH SMACNA REQUIREMENTS. VERIFY DUCT TIGHTNESS IN ACCORDANCE WITH THE FLORIDA ENERGY CONSERVATION CODE. TESTING SHALL BE IN ACCORDANCE WITH APPLICABLE SECTIONS OF ASHRAE STANDARD 152. PROVIDE AN UNCONDITIONAL, ONE (1) YEAR WARRANTY FROM DATE OF SUBSTANTIAL COMPLETION ON ALL PRODUCTS AND WORKMANSHIP PROVIDED FOR THIS PROJECT. SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE #66080 EN of y N .6608 OF CORIDP; Ga�`� S,ONA1 vJ F� z z o a a z v � w E~ ca � w Q c7 z a w w N ca z 0 w a DATE DESIGNED BJM 02-23-21 DRAWN NUN 02-23-21 CHECKED JOB NO. 2021-062 M=2 POOL EQUIP w-mn 14'-4" w 0 O) W OPEN AREA 23`-6-1 �HB WH 7'-4" 10'-0" MECH. ROOM o N JB N 3068 DOOR W/D 1-0'-0" MUD ROOM 18 17 (2)-3' FRENCH DOORS 16 15 8070 OHGD UP 144 r p I 8'-0" I 1'-4" � ? 14'-10" STAIR 4'-21" 4'-22., 1'lr' 18'-8" FURST L SCALE- 1/4" = 4'-0" STORAGE ROOM x 21'-4" 10'-0.. 0" EXERC SE AREA J N C. 0 O M af 0 0 M J N O w 0 ill ID: POWER PANEL GARAGE #2 FPL METER W m 36" HIGH GLASS GUARDRAIL SYSTEM WITH HANDRAIL PER 2020 FBCR 16'-0" 16070 OHGD GARAGE ENTRY I SCALE- 1/4" = 1'-0" LSYSTEM PER ��,_ lvvvlI 1 PROVIDE DESIGN &FORENSICS, INC. 4" O.C. MAX. 725 SE PORT SAINT LUCIE BLVD, SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL!PE #66080 a � .66080 STATE OF rir�•"• PLOWO !/l111Q11\��� z 0 a of U V) w O w a z 0 In w ce Vl Q O J z O u LLJ L) 66 F— LL DATE DESIGNED B1M 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 T/ PARAPET 34'-4" (41.83') T/ PLYWOOD 21'-0" PLYWOOD 10'-0" SLAB 0'-0" (7.50') L- - - - - - - - - - - - 72X84 SLIDER 38X84 FG 72X84 SLIDER �!J�L 72X84 SLIDER 38X84 FG 72X84 SLIDER 8'x7' OVERHEAD STEEL DOOR o$ FRENCH DOORS 14'-0" 72X96 FG 72X96 FG HIGH POINT OF ROOF ROOF SURFACE BEYOND - - - - - - - - - - - / - FRONT ELEVATION SCALE- 1/4" = 1'-0" 120100 SGD i III i III 11 12090 SGD III III /11 16'x7' OVERHEAD STEEL DOOR PER ZONING MAXIMUM ROOFlNG HT. = 8.52'+35.00' = 41.52' 48X48 FG 48X48 FG 48X48 FG 48X48 FG 108X96 FG 108X84 FG 30X108 FG 30X108 FG r a 0 3068 DOOR LEFT ELEVATION SCAM' 1/4" = 1'-0" PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures FL#: 20383.1 Horizontal Slider ES-SW340 E.S. Windows Impact 1/4" x 1 1/4" min embedment Tapcons 8.5"o.c. See Table +80/-90 Window at max. FL#: 21461.1 Fixed Window ES-EL150 E.S. Windows Impact 1/4" x 1 1/4" min embedment Tapcons 12' See Table +80/-105 at o.c, max. FL#: 17893.1 Sliding Glass Door ES-6500 E.S. Windows Impact (2)-5/16" x 1 1/2" min embedment Tapcons 12'o.c. See Table +120/-135 at max. FL#: 21835.1 Swing Doors ES-46T E.S. Windows Impact Im p 1/4" x 1 1/4" min embedment Tapcons 10"o.c. See Table +100 -120 / at max. FL#:16546.4 Overhead Door 73W6 Clopay NA 5/16"xl-5/8" lag screw spaced at the same distances See Table +36 / -42.0 as the track (see ohd buck detail for more information) Approval Number Product Model Number Manufacturer Attachment Method Building Rated Design Pressures Product Rated Design Pressures FL#:1654.1 B Mod it Roof System System W-213 Polyglass Self -adhering base and cap sheet. Provide 4" wide elastoflex SA V Plus -134 (Zone 3) -135 T/ PARAPET 34'-4' PLYWOOD 21'-0" T/PLYWOOD 10'-0" T/ SLAB 0'-0" (7.50') 2 WIND ZONES - WALLS WEND DESIGN PRESSURES END ZONE WIND SPEED TRIB. AREA ZONES - PSF 1 2 3 4 5 4 FT. 170 MPH <10 S.F. -84.5 -111.5 -152.0 +53.0 -57.5 +53.1 -71.1 20 S.F. -75.0 -99.3 -127.7 +50.7 -55.1 +50.7 -66.1 50 S.F. -62.4 -83.1 -95.2 +47.4 -52.0 +47A -60.0 100 S.F. -53.0 -71.1 -71.1 +45.1 -49.6 +45.1 -55.1 500 S.F. +39.6 44.0 AI_LO W ABI E DOORS, FR7 BUILDING C ROOFZONE WALL ZONE ,,46UMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL, PE # 66080 �\GENS, 4 a ix *; i ,a1 ST F'LIJ I� i ORIOP'•0' NA1 "t j F � z o � � z U � H Q w Q z Q w N a q r' m z 0 5 w cG DATE DESIGNED BJM 02-23-21 DRAWN NUN 02-23-21 CHECKED JOB NO. 2021-062 PARAPET 34'-4" (41.83') PLYWOOD 21'-0" PLYWOOD 10'-0" SLAB 0'-0" (7.50') 8080 SGD s T/ RIDGE ROOF SURFACE BEYOND (41.33) HIGH POINT OF ROOF 36X120 FG 144X120 FG 36X120 FG r I I I s I I r I I I r 36X108 FG Ill mill 0DIM1I01G REAR ELEVATION SCAIR- 1/4" = 1'-0" 36X108 FG PER ZONING MAXIMUM ROOFlNG HT. = 6.52'+35.00' = 41.52' 3080 SL 3' DOOR 3080 SL Il RIGHT ELEVATION SCALE- 1/4" = 1'-0" z,=0" ,,\A�SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 66080 0. 80 STATE OF •'� !V H z z O U a z u � H Q w c z Q w N Q z c 5 w a V) z p W DATE DESIGNED BJM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 A=4 COPING & NAILER MOD BIT ROOF SYSTEM R20 SPRAY FOAM 5/8" PLYWOOD INSULATION T.O. MASONRY B.O. TRUSS NEW 8" MASONRY WALL — GROUT SOLID AT REINFORCIP T.O. PLYWOOD. Y TGl -V OL B.O. TRUSS +19'-0" PTD. STUCCO FINISH - NEW 8" MASONRY WALL - `� GROUT SOLID AT REINFORCING me ft OL T.O. PLYWOOD +10'-0„ B.O. TRUSS +8'-0" NEW 8" MASONRY WALL GROUT SOLID AT REINFORCING FINISH GRADE — T.O. SLAB +0'-0" Ii i illiii) l SECTION A 1,1=1' SCALE II,D,I VAPOR BARRIER COMPACTED CONCRETE TERMITE TREATED FOOTING SOIL T.O. MASONRY +31'-0" NEW 8" P GROUT E T.O. PLYWOOD. +21'-0" B.O. TRUSS NEW 8" 1 GROUT c B.O. TRUSS NEW 8" N GROUT S FLO( T.O. SLAB +0'-01, VAPOR BARRI CO TERMITE 12 MIN. F— MOD BIT ROOF SYSTEM 5/8" PLYWOOD R20 SPRAY FOAM 12 INSULATION ER M TREATED PRE-ENGINEERED ROOF TRUSS SPA. @ 2'-0" O.C. NON -SAG GYP. BOARD 1/2" GYPBOARD 1X2 P.T. FURRING @ o 24" O.C. o+ 1ASONRY WALL ---- OLID AT REINFORCING 1/2" PLYWOOD 3/4" T&G PLYWOOD 44 PRE-ENGINEERED FLOOR TRUSS SPA. @ V-4" O.C. NON -SAG GYP. BOARD AASONRY WALL SOLID AT REINFORCING Ti o 'i ell as 1/2" PLYWOOD 3/4" T&G PLYWOOD' 0 4. N PRE-ENGINEERED FLOOR TRUSS SPA. @ V-4" O.C. Z" NON -SAG GYP. BOARD IASONRY WALL - OLID AT REINFORCING o I� A i )R FINISH 4" CONCRETE SLAB a <a I, D,I PACTED I_ " "r° <'�' CONCRETE SOIL f D FOOTING • z"=1' SCALE .4ka.,SUMMIT SIGN & FORENSICS, INC. i SE PORT SAINT LUCIE BLVD. Cl ITTC nA1 ENS�c , f 0:66080 ST4,TE OF ; j TOR10P O \� z 0 a u U N W w a 0 z 0 w DATE DESIGNED BIM 02-23-21 DRAWN MJN 02-23-21 CHECKED ®,`.SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 - FBRIANToSKOLFL PE 66080 s STATE OF I IP �/ z- -. Z O a u U uj w 0 w h Q Z O U) w K W ~ J 0 LL .W ~U oC OW f2 Qry UO �LL J W CL Z O U w V) DATE DESIGNED BJM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 A-6 GENc RAI_d REQUIREMENTS All :writ to be as aeethe currer 4edition of the Florida Bulidinrg Coda and meet or exceee a'! appFccfble local requirements. 'C,Inelal coniroctor is responsible to, ct labor, materials, a,Ulties, testing we,,st ^e rrsmavv,, starers seaurincof site'ac<' +r 9 3 ,om�oda€ton; fira.,sp«rt/i.esg}ti; and a11 ether cost related o tie c:irnpie:ron of This project., unless explicitly i t t f�ea here Ovner is responsible for ol: Muo;c:pol related charges such as impact fees,one crater connec ions, except building permit fees, which are to ne includen III the constri,iction a,i.. :general contractor to check all drawings for errors and ammissions and brinlc there fo the a en ion a- the { r nrt:ct prior to starting any work, or �o s ct the respective ? Y �ire d:vslrxr of worksuch s,rors and ornmissionc- are no repor,ed :n -w ,t,rgto the arch tec.t, any resultinc Carnaaes or Ca.4" .h" steal t. I be born entirely by tae general contraatcr, hf<il ls no'. resronsibk,, for ,re con tractors nielhod or amens o' ce a u cLion, r[c . oln c-w rot<c One 'nstacictior, of specified h<aroware shoall cor.fcrrn to t ne rnonufactur-is .nscrr,,.,;uns ono standard rsroctice, Al Plans and a,awings are not considered co, iplete until they have seen rotrcwry and jppro,rec oy the Building ;e:cri­ie­t C; ,:. the hu Idiog pert^,_t has dcon 'ssuec... HRESHOCr D NOTE At egress ss door (Er Vy Door) r) the rnox hgth; of the thres Ala. t 6ii ae 1/2" BUCK A i TACHMENT NOTE 'I DOORS USE 2XF1.1t 'I( cD Al"ACH SUCKS TCG-C Wr ,i 1/4 D€A. iA CONSW7H 2 1/4 EMB M'"N h I, C,.L.S S_ C ,A b -f C7M S,ah c 2 AND A i d c.c. VAX. AT wNDOWS ha 1x FINE ANa AT,AO DUCKS i(1 BLOCK 4wr 1�- Be CASED HARD C;o;I_ NAILS - `' , A!th 4" PGid ENDS AND12"0.�. t, STRi CTURAt." SONS 'DURING; DOOR NSTA,1 A71ON WO )D AND/OR CEDAq SH MS SPCA,_] NO BE USED. EXTERIOR CEILING & SOFFIT NOTE fE ` u v inisn over 3t'8high ribbec gale wire nth fastened to crarng „ ern nerd wiT, Na-11 guage naile with 1 3/4 embed, c;ith -1/ kin `read b u c. max edges to be ties and n<r,led at 9'0.c, as.:ie one: layer of 13# Pelt ,o bt;i;nmr "orni^g before stal9irg 1iNISHES Wall and ceiling finishes shall ccimpiy with 102..9 of the 2020 Florida Residwratai Budding Dade. Wail and ceiling n s ras sh it _.avc ca .arrro yo rat -n Jex of not cgreoter than 200. .loci a€' I ceiling fi-isne3 shaall ten � a smoke deveopea index of not pr t. than 450 - 1,' uk,t,c n. shalt corns v ante, 302O of [tie 2020 Florida Residen' icl st srldincu Code in o utfor inn e ials chat have a flame spread index not to -exceed 25-with an necornparying smor,,o developed `ncl aol,;to exceed 450. r' Oyi taocrd ;not<ri a hall corriply with 702 3 1 of his 2020 Florida'heseentiu4 a,g Code, "C ypsa.rra trr�ar € n'aater cls shellc,.arr^corn to A.f;-'it r 22, C,4 r5, "' 14, : 1002,. C:C47, C 7r, G1 T8, C`1278, 111396 or _1 58 Acihes es she conforr , to ASTA, C.:,r57 ,Pic fI e sr,clj c. .. rn Wto 702.1 of the 2020 F undo Residential Building Cade. shall be i corner bars at beam (ours:de only) (2) corner 8" x 16' C.M.W. WITH CELLS FjLL.=D bars at footing (rnin.) WITH GROJT & #o VE:RT. _ DOWEL I r — F'.1`.2x6A`C 3 SIDES { } S Oc5 0"r` OPENING, FASTEN TO KOCK ell co ner sure l w �... AS NOTED. __ I snares irr r;iare. =r vent. dowel lapped with -- , a a c. DOOR SIDES sac: r. r ._..__ _ wall reinforcing, ,ail p sty ... no 3z x, t..l our, g r / _ 6m c la s 25" min. i rout 'n :eating, bearr s, avu cwalls 1 f2"" x 6" REDHEADS WITH MIN. p ( } 9 2 x 1 /F" WASHER 12" FROM ENDS .NDS filled eel;. AND 24 o.c. MAX. "OR" a { 5 8` x 6" REDHEADS �dA15S WITH M.N. a ( 2" x t f8"VdASI1ER 12` FROM ENDS I iI AND 28`o.c. MAX. „OR" 1 /4°x,..._1/4"TAPCON MIN EMBEDMENT SPACED - 7-1/2' O.C. W/1" O.D. WASHERS SPACED POi`TOM ANCHOR r 3_112.. FROM BOTTOM OF 2x6 & TOP ANCHOR -6 AT LEAST AS HIGH f -- I-1 AS THE DOOR OPENING DOOR HEAC). _ 1/4x 2 3/4" TAPCONS STAGGERED I 24"o.a. Gar -Coe Door Buck Det • all i I ,--E " x 4 bottom chord bracingCorner Reinforcing ------_._._�_ e t a l 24''rnir. lap (2) 16a of each truss i� I 3 � car _nuo us beea or / 3 bottom chard of caulk (black bedding) behind wood trusses t�ucsc to reinvent liquid passage ernbedrnenl', at V"JI 1iiGIV':", :°jnd r. set flange in continuous d i 1 12„ emCed,ment c�t r a r bevel. O, k / C 7 a CrQSS tilE d l i 1 r \ d doors entire fees or , n�au� d d 1/2 Jr,rbnail t l 1. 10 011 1 Bottom Chord Lateral Brach I •r tc s#u.,co ��r . li1"C.%r COtalk f , e 1 e max. Str1.let. Shirt.. Attach pit. bucks ---------- wit/ l � q ry cofl nails at / I ' - mU. ANl l AiOG. , At V8.4, A10a Ji , ..6.i and A13 ,'= :,. F- of r ccrntn', et reinforced comer titious bdctK yg sum `backers or fib r reinforced grosunn t.:arkrrs in cornp�;rrce with ASTM e'298, G15211, C117E or r?1278= re p{.ctv,.ty,dnd.irazafalled in cvGcorC}nnr- w:lh Yi'=f.r,_<1.­,wp �6 inn, cfaCdl hp Jt+lat{ ec t,h^+a va ,,DY urn i>Eci Srr` h,i-, rr H, ck­,r,.- e-manufac-lured nor/roof trusses -011 o.c. drywall cielirrg c4 galvanized meta' track or c4 loo plate drywcll both sides 2x4 trier studs or 2x4 wood studs spaced @ 24" ra:c. baseboard (typ.) 2x4 galvanized track or 2x4, wood pit, bottom plate 4" thick concrete slob (2500 fnsi)with fiber mesh over vapor barrier over clean corraDocted termite trecte:d soil T P INTERIOR NON LOAD - HARING ARING WALL SECTION j"=1' SCALE L: Typ. Alum. winrcW Y / at�cch as Der Jarred or sliding glass nine aPa tuners door J amn �;ad ct approvals NOTE: Method of �.avt yr rr1e� Grid Waterproofing ;}roc dt,irc;s or",, the some at potired concrete sill- Cunable sealon'ts sric1. crum.r`y Rui,.lr ASTM C 920 C ass 25 i;rrit r greater for proper jorl. exnn sio and contraction Typical Window � 'S.G.D. numb Detail at CBS Wall Includes Buck Attars a nt Pvi:aticc ------ — ..w _. _---- w_.- _--___-. 7E SIC CJC C l /t;, rr- �r-'`(l '4 2 r (0 E � � �E\ .a "7 i> ,. S ( ( r fi i s t../ t.l d_. � � V � � l.F �..I S 4 � � I � � .,i . � � '.,..., r�� ..>) f I � �l t...J Alum. Window _ .... frame 3,/8" continuous bead of corrosive resistant caulk (back bedding) behind \ /__ a Tapcon concreteshire to prevent liquid possoge �> f crews installed as specified in window 1/4" struct. shim - ti manufacturers product set flange in continuous__ approval i t bead of caulk across the entire face of buck perimeter caulk stucco finish Q [Note, Provi e doL e anrfc3 beambeam kaeiarr srer act .,Ili.arovideg s each band boom and extend tears 8" into Jorvcs. Gur:able sealants shall comply with Isee Structural notes. ASTM C 920 C ass 25 grade or greeter for proper joint expansion 1 and contraction r precast Carlo, Fi .I'cal Forecast Conc. Sill Detail SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE #66080 vvN��NN J. MAS�77ii ENSF .66080 ;ir 1J STATE OF k4U T� • �L O 19 P •r.�c°,�� �///r,a z 0 U W LU 0 z O U) w w Evy _J LJ C) LLJ �- C1 LJLL W ®- Uj Ill— Z 06 J Uj DATE DESIGNED BJM 02-23-21 DRAWN MJN 02-23-21 CHECKED F_ JOB NO. L )21-062 ..��SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE #66080 o. 66080 o ®; STrEoF lPllt\\�\ z O a cc U U) w 0 w H Q z O to w 00 ~ J 0 LL �W ~ U OW CL a Q� UO �LL w a_ z Q J CL W O O 66 w F- O z O Q z O LL DATE DESIGNED BIM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 COLUMN (TYP.) CONCRETE FOOTING (TYP.) NOTES: UN DATION PLAN WF1 = WALL FOOTING MARK. SEE FOOTING SCHEDULE ON SHEET S-7. SCALE- 1/4" = V-0" Fl = SPREAD FOOTING MARK. SEE FOOTING SCHEDULE ON EXCAVATE AND REMOVE THE LAYER OF SHEET S-7. IC MATERIAL DOWN TO CLEAN GRANULAR AL FOUND AT APPROXIMATELY SIX FEET Cl = CONCRETE COLUMN MARK. SEE COLUMN SCHEDULES ON ALL BUILDING AREAS PLUS FIVE FEET PAST SHEET S-7. [TER PERIMETER OF THE BUILDING PER THE .HNICAL ENGINEER. COMPACT NEW FILL SPREAD FOOTINGS SHALL BE CENTERED ON COLUMN UNLESS AL PER GEOTECHNICAL ENGINEER. NOTED OTHERWISE. WALL FOOTING TO BE CENTERED ON WALL UNLESS NOTED OTHERWISE. .DUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN I. MASKOL FL PE #66080 �o\\11II////// J. GEMA Ns vkX 08 TA OF z O a d U Lu w w F Q z O Ln w K ~ J �u. .W ~U oC OW a'-' a Q L.L. VO �LL J W a. z J 0 Q 0 0 LL DATE DESIGNED BIM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 S-1 8" MASONRY WALL----\ GROUT SOLID AT REINFORCING #6 SPACED @ 3'-4" O.C. MAX & AS SHOWN (TYP) �) 7 '-A" PRE-ENGINEERED ALUMINUM BALCONY. SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY ENGINEER. I S-5 C4 Fil, 62 ----------------------I C3 B2 +10'-0" C4 F S-5 L E#5 DOWEL @ 1'-0°' O.C. S#5 @ 1'-0" O.C.OP AROUND EXTERIOR BOTTOM PERIMETER NT o o O + 0 0Ell 1 00 000 � 3'-0" B5 Cl Bs Bs 0 rn CONCRETE SLAB. 7" MIN.THICKNESS M� S-5 STEP AS REQ'D FOR TILE SYSTEM L_5 0 o Q o 0 o a o ❑PRE L5 O C1 tr' Kf -EN EER FL R TRUSS PA -4" m z a (TYP-)PLYWOOD ❑ o BB1 (+10'-0") ❑ O BBi (+8'-0") • ❑ MAX &AS SHOWN TYP 8" MASONRY WALL. /F ❑ ❑ O GROUT SOLID AT TYP. TYP. D ' o T.U. PLYWOOD L-5 s-s I] o ± TRUSS SPA V-4" O.C. 8" MASONRY WALL. ❑ I FL R cocoGROUT SOLID AT o TRUSS SPA. @ 1'-4" O.C. o ❑ ULU PLYWOOD v D H m O 2" ❑ G.T. .T. iv (2)-2 8 P.T. ❑ o DN U UP ❑ ❑ �011 O IE0 Ell 11illEl!OO L-2 BB1 (+10'-0") L_1 E S-5 TB1 (+15'-4") ❑ 0 B6 (+10'-0") S 5 o cn rl STAIR TB1 (+ 00 L 5'-4) C•] 0 00 0 B5 CONCRETE SLAB. 7"- MIN.THICKNESS j;_, S LS #5 @ V-0" O.C. BOTTOM 20'-8" O O O TBl (+15'-4") 10'-8" f w� SCALE- 1/4" = V-0" #6 SPACED @ 3'-4" O.C. MAX & AS SHOWN I (TYP) 8" MASONRY WALL GROUT SOLID AT REINFORCING 0 O m m ll_D TYP. #5 DOWEL @ 1'-0" O.C. TOP AROUND EXTERIOR PERIMETER STEP AS REQ'D FOR TILE SYSTEM B5 NOTES: (+XX'-XX") = TOP OF BEAM ELEVATION REFERENCED FROM ELEVATION +0'-0". Cl = CONCRETE COLUMN MARK. SEE COLUMN SCHEDULES ON SHEET S-7. B1 = CONCRETE BEAM MARK. SEE BEAM SCHEDULE ON SHEET S-7. L1 = PRECAST LINTEL. SEE LINTEL SCHEDULE ON SHEET S-7. G.T. = PRE-ENGINEERED WOOD GIRDER TRUSS. AO = CONNECTOR. SEE SCHEDULES ON SHEET S-7. DOWEL MASONRY WALL TO CONCRETE COLUMN W/ #3x1'-0" LNG. DOWEL EPDXIED 6" INTO EXISTING SPA. @ V-4" O.C. FIRST FLOOR WALL FILL CELLS SHOWN. , SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN 1. MASKOL FL PE #66080 v � ® r it ! O. 1 ATE OF to z 0 it U w w 0 w z 0 w oc ee F__ J 0 LL W zU I _4 c� 0W H ce U F-- I u- w a- CL V H f� u_ 0 0 u_ 0 0 U Lu U) DATE DESIGNED BIM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 THIRD FLOOR FRAMING PLAN SCALE- 1/4" = P-0" NOTES: (+XX'-XX") = TOP OF BEAM ELEVATION REFERENCED FROM ELEVATION +0'-0". Cl = CONCRETE COLUMN MARK. SEE COLUMN SCHEDULES ON SHEET S-7. B1 = CONCRETE BEAM MARK. SEE BEAM SCHEDULE ON SHEET S-7. L1 = PRECAST LINTEL. SEE LINTEL SCHEDULE ON SHEET S-7. G.T. = PRE-ENGINEERED WOOD GIRDER TRUSS. OA = CONNECTOR. SEE SCHEDULES ON SHEET S-7. = DOWEL MASONRY WALL TO CONCRETE COLUMN W/ #3x1'-0" LNG. DOWEL EPDXIED 6" INTO EXISTING SPA. @ 1'-4" O.C. SECOND FLOOR WALL FILL CELLS SHOWN. ,\`.SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN ]. MASKOL FL PE #66080 J. a,6 80 STATE OF %,IVe z O a K U w w F Q z O Ln w OC z a z Q U- QC O 0 U. DC 2 DATE DESIGNED BIM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 S-3 FILE f RAMING PLAN SCALE- 1/4" = V-0" SEAM ELEVATION REFERENCED FROM MN MARK. SEE COLUMN SCHEDULES ON 61 = UUNCKt It: BEAM MARK. SEE BEAM SCHEDULE ON SHEET S-7. L1 = PRECAST LINTEL. SEE LINTEL SCHEDULE ON SHEET S-7. G.T. = PRE-ENGINEERED WOOD GIRDER TRUSS. OA = CONNECTOR. SEE SCHEDULES ON SHEETS-7. ■ = DOWEL MASONRY WALL TO CONCRETE COLUMN W/ #3x1'-0" LNG. DOWEL EPDXIED 6" INTO EXISTING SPA. @ V-4" O.C. THIRD FLOOR WALL FILL CELLS SHOWN. .O\SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE #66080 80 OTATEOF : S �40RI C}e°\�e o kw �I///l1\ z O a uU w O F Q Z O w K W ~ J ®u- 'W _7 U Ow ci a _7 <z � UO �J U- LIJ 0 DATE DESIGNED BIM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 CONT. 4" SIMPSON TITEN HD ANCHOR W/ NUT & PLATE WASHER SPA. a @ 1'-4" O.C. (6" MIN. EMBED.) GROUT MASONRY SOLID AT ANCHORS. jk T.O. BEAM N�JSEE PLAN 8" CMU WALL MASONRY BOND BEAM, SEE BEAM SCHEDULE FOR REINFORCEMENT & SIZE 4 WALL REINFORCING, SEE PLAN a d SECTION A CONT. 8d RING SHANK NAILS CONNECTORS, SEE. PLAN SPA. @ 3" O.C. 4 8" PLYWOOD. FASTEN W/ 8d RING 8" PLYWOOD. FASTEN W/ 8d RING SHANK NAILS SPA. @ 4" O.C. SHANK NAILS SPA. @ 4" O.C. T.O. BEAM aI SEE PLAN M M� MASONRY BOND BEAM, SEE BEAM SCHEDULE FOR REINFORCEMENT '^rv) loo &SIZE (2)-2X8 P.T. LEDGER WALL REINFORCING, a- ( a, 34" SIMPSON TITEN HD ANCHOR (2)-2X8 P.T. LEDGER SEE PLAN W/ NUT & PLATE WASHER SPA. @ 1'-4" O.C. (6" MIN. EMBED.) GROUT MASONRY SOLID AT 8" CMU WALL Pll ANCHORS PRE-ENGINEERED WOOD ROOFTRUSS 10d NAILS SPA. @ 3" O.C. 1" T&G PLYWOOD (NAILED W/ 10d SPA. @ 6" O.C. & GLUED) T.O. BEAM ° SEE PLAN z" PLYWOOD MASONRY BOND BEAM, 4 i SEE BEAM SCHEDULE FOR REINFORCEMENT �. & SIZE 4' (2)-2X8 P.T. LEDGER WALL REINFORCING, 4 SEE PLAN a 3" SIMPSON TITEN HD ANCHOR W/ NUT & PLATE WASHER SPA. @ 1'-4" O.C. (6" MIN. EMBED.) 8" CMU WALL SECTION E SLIDER SYSTEM (TYP.) PRE-ENGINEERED ALUMINUM BALCONY 1 /_4" T&G PLYWOOD (NAILED W/ 10d SPA. @ 6" O.C. & GLUED) r6T.O. BEAM 111PSEE PLAN ° f I MCO z" PLYWOOD 4 2" CLR. b • •a q ' (2)-2X8 P.T. LEDGER CONCRETE BEAM, SEE" 4" SIMPSON TITEN HD ANCHOR BEAM SCHEDULE FOR W/ NUT & PLATE WASHER SPA. REINFORCEMENT & @ 1'-4" O.C. (6" MIN. EMBED.) SIZE SECTION B " SIMPSON TITEN HD ANCHOR W/ NUT & PLATE WASHER SPA. @ 8" O.C. (6" MIN. EMBED.) JA T.O. BEAM q�JSEE PLAN - 8" CMU WALL b MASONRY BOND BEAM, SEE BEAM SCHEDULE FOR REINFORCEMENT & SIZE 4' WALL REINFORCING, SEE PLAN 10d NAILS3 SPA. @ 3" O.C. SECTION I 1"=1'-o" #5 X 3'-0" LNG. CONCRETE SLAB 12 DOWEL SPA. @ 1'-0" 7" MIN. THICKNESS 1/8I O.C. W/ STD. HOOK aa v d b a n a a CONCRETE BEAM, SEE U BEAM SCHEDULE FOR d c #5 SPA. @ 1'-0" O.C. REINFORCEMENT & EACH WAY SIZE U 1"=1'-0" :ONNECTOR, SEE PLAN (2)-2X8 P.T. LEDGER 4" T&G PLYWOOD (NAILED W/ N10d SPA. @ 6" O.C. & GLUED) Ln coI/ t z" PLYWOOD PRE-ENGINEERED WOOD FLOOR TRUSS SECTION F 1"= r'-o" 4" SIMPSON TITEN HD ANCHOR W/ NUT & PLATE WASHER SPA. @ 8" O.C. (6" MIN. EMBED.) „ T.O. BEAM SEE PLAN , MASONRY BOND BEAM, SEE BEAM SCHEDULE FOR " REINFORCEMENT & SIZE 8" CMU WALL—� �/ v WALL REINFORCING, SEE PLAN: /// SECTION J 0 U- pw o' wLn >_ �V) QLu a F- w CONCRETE SLAB 12 Ln 7' MIN. THICKNESS 1/$� 4 a 4 � 4 ,.4 4 4 v s 4 — Td 4" J _ U #5 SPA @ 1'-0" O C #5 CONT. 8" CMU WALL 8d RING SHANK NAILS SPA. @ 3" O.C. #5 DOWEL SPA. @ 3' 4" O.C. a $" PLYWOOD. FASTEN W/ 8d RING SHANK NAILS SPA. @ 4" O.C. T.O. BEAM ° INVSEE PLAN C)° uioo :-� 4. �4. .4J,. (2)-2X8 P.T. LEDGER 4" SIMPSON TITEN HD ANCHOR CONCRETE BEAM, SEE W/ NUT & PLATE WASHER SPA. BEAM SCHEDULE FOR @ 1'-4" O.C. (6" MIN. EMBED.) REINFORCEMENT & GROUT MASONRY SOLID AT SIZE ANCHORS SECTION C 8" CMU WALL a WALL REINFORCING, SEE PLAN a, T.O. BEAM SEE PLAN A 2" CLR. Ir4 OPEN la:l a CONCRETE BEAM, SEE BEAM SCHEDULE FOR REINFORCEMENT & SIZE a y SECTION G CONNECTOR, SEE PLAN -(2)-2X8 P.T. LEDGER 4" T&G PLYWOOD (NAILED W/ /l__10d SPA. @ 6" O.C. & GLUED) 2" PLYWOOD PRE-ENGINEERED WOOD FLOOR TRUSS 1"=1'-0" SLIDER SYSTEM STANDARD HOOK 10d NAILS SPA. @ 3" O.C. 4" T&G PLYWOOD (NAILED W/ 10d SPA. @ 6" O.C. & GLUED) T.O. PLYWOOD �i SEE PLAN Z PLYWOOD �N EACH WAY 4 \—(2)-2X8 P.T. LEDGER b" SIMPSON TITEN HD ANCHOR W/ NUT & PLATE WASHER SPA. @ 1'-4" O.C. (6" MIN. EMBED.) MASONRY BOND BEAM, 8" CMU WALL SEE BEAM SCHEDULE FOR REINFORCEMENT WALL REINFORCING, SEE & SIZE. REINFORCING PLAN TO BE CONTINUOUS THROUGH SLAB. CG('TT(li\l M T.O. BEAM CONNECTOR, SEE PLAN / 8" PLYWOOD. FASTEN W/ 8d RING / SHANK NAILS SPA. @ 4" O.C. id PRE-ENGINEERED ROOF TRUSS SPA. @ 2'-0" O.C. 8" CMU WALL • WALL REINFORCING, SEE I. PLAN SECTION D I"= I'-0" PRE-ENGINEERED ALUMINUM PERGOLA/SUNSCREEN WINDOW SYSTEM 2" CLR. .P r v L ah e I g a d CONCRETE BEAM, SEE BEAM SCHEDULE FOR REINFORCEMENT & SIZE LIDER SYSTEM SECTION H 1"=1'-o" O w� pw F w r SLIDER SYSTEM (TYP.) U) STANDARD HOOK �_ 10d NAILS SPA. @ 3" O.C. w ~" T&G PLYWOOD (NAILED W/ 12 v~i 10d SPA. @ 6" O.C. & GLUED) CONCRETE SLAB 1/8F T.O. PLYWOOD 7 MIN. THICKNESS OgL SEE PLAN e 4 s 4 aq a z" PLYWOOD o-d uiloo U 4� �.. #5 SPA. @ 1'-0" O.C. EACH WAY (2)-2X8 P.T. LEDGER CONCRETE BEAM, SEE 4" SIMPSON TITEN HD ANCHOR BEAM SCHEDULE FOR W/ NUT & PLATE WASHER SPA. REINFORCEMENT & @ 1'-4" O.C. (6" MIN. EMBED.) SIZE SECTION K J -V #3 TIES. @ 8" O.C. � a co b A Q b C of �y b N 2" CLR. V#6 (TYP.) 8" DETAIL 1 1"=1'-0" 1"= I'-o" 2" CLR. #3 TIES. @ 1'-0" O.C. #3 TIES. @ 6" O.C. � a N d ry J° o (12)-#7 AS SHOWN DETAIL 2 1"=1'-o" 3 .�s �SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE #66080 \��\\\W I W11//1/ x4 A�k0/sue/ E 6 0 ATE OF 1441 ,o` FCORIOP C9���\� C� z 0 a u U Ln w 0 w a 0 z 0 Ln w 00 ~ J OLL J \Lij F- U I--1 �• pw as a� Up �LL J ui LL J F—I 0 06 z O U w Ln DATE DESIGNED BJM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 Sm5 Jip NOTE: GROUT MASONRY SOLID BELOW GRADE a i �p T.O. SLAB ll�JSEE PLAN GRADE /-771 WALL REINFORCING, SEE PLAN NOTE: GROUT MASONRY 4 If 8" CMU WALL SOLID BELOW GRADE 4 CONCRETE SLAB, SEE PLAN FOR SIZE & REINF. o VAPOR BARRIER g T.O. SLAB 0- " \ SEE PLAN ✓ FOOTING, SEE PLAN & FOOTING SCHEDULE / — COMPACTED EARTH 3''CLR. ° \ STANDARD HOOK a °4 °a / REINFORCING PER CI SCHEDULE `L WALL SECTION N 1"= V-0" d STEP AS REQUIRED 11 FOR TILE SYSTEM { ik T.O. SLAB IRV SEE PLAN — a / 3''CLR. 4 u EQ:� WALL SECTION Q WALL REINFORCING, SEE PLAN 8" CMU WALL CONCRETE SLAB, SEE PLAN FOR SIZE & REINF. VAPOR BARRIER a x/\�" _ FOOTING, SEE PLAN & FOOTING SCHEDULE COMPACTED EARTH STANDARD HOOK REINFORCING PER SCHEDULE WALL REINFORCING, SEE PLAN 8" CMU WALL CONCRETE SLAB, SEE PLAN FOR SIZE & REINF. N VAPOR BARRIER NJ I�� q � `\ FOOTING, SEE PLAN & X /\\\•�'���\\\ / / � FOOTING SCHEDULE / COMPACTED EARTH 3"°CLR, ° STANDARD HOOK REINFORCING PER U ? a SCHEDULE M J^ 4 Ya \ . T.O. SLAB SEE PLAN J U WALL SECTION O REINFORCING. SEE PLAN. CONCRETE COLUMN. SEE PLAN. 2" CLR al x¢ CONCRETE SLAB, SEE PLAN g 7 i FOR SIZE &REINF. or6T.O. SLAB VAPOR BARRIER ~ GRADE SEE PLAN g' g�\ FOOTING, SEE PLAN & FOOTING SCHEDULE / . � \f�--- COMPACTED EARTH 3" CLR. ° r STANDARD HOOK REINFORCING PER SCHEDULE M � c "o 77 EQ, EQ. CLCOLUMN SECTION P 1"=1'-0" fj 41 TTT: MASONRY COLUMN, SEE PLAN I -CONCRETE SLAB, SEE PLAN ° ll it FOR SIZE & REINF. ° VAPOR BARRIER a. vd FOOTING, SEE PLAN AND FOOTING a \ SCHEDULE a 3" CLN d REINFORCING PER SCHEDULE COLUMN COMPACTED EARTH EQ. EQ. SECTION R STANDARD HOOK (TYP.) BOND BEAM a d �r a d O a a 4 d 4 4 c a . ri o'. 4. 4 REINFORCING, SEE PLAN WALL REINFORCING DETAIL 1"=r-0" , SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE #66080 0.66080 s OF z 0 ~a U w w a 0 z 0 w 00 OLL W zy�/ 1� lclL ow �a aIry- U0 �LL J W a- J 66 z 0 U W U) DATE DESIGNED BIM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 Sm6 FILE COPY CONNECTOR SCHEDULE MARK CONNECTOR/FASTENER OHGAM10KTA W 1 x- to truss 4 x- 4 to masonry plus (2)-MTS12 W/(14) 10d x 1-1/2" to each truss V (2)-MSTCM40 W/(26) 16d SINKERS & (14)-4" X 24" TITEN2 EACH O HETALI6 W/(14) 10d X 1-1/2" OD HGAM10KTA W/(4) 1/4" x 1-1/2" SIDS to truss & (4) 1/4" x 2-3/4" TITEN 2 to masonry OHTT4 W/(1) $" THIRD. ROD EPDXIED 7" INTO WALL & (18) 16d X 2Z". FASTEN TO SIDE OF TRUSS TOP CHORD. OHGAM10KTA W/(4) 1/4" x 1-1/2" SIDS to truss & (4) 1/4" x 2-3/4" TITEN 2 to masonry spa. @ 2'-0" o.c. 0 /O `U O Safe Load Table Notes Installation Notes 1. All values based on minimum 6" nominal bearing. 1. Installation of U lintels must comply with architectural Exception: Safe loads for unfilled U lintels must and/or structural drawings. be rg pced by 20% if bearing length is less than 6 1 2'. 2. U lintels can be field cut to the required length. 2. N.R. = Not Rated 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 3. Safe loads are superimposed allowable loads. 4. The exterior surface of U lintels installed in exterior 4. One #7 rebar ma�y be substituted for two #5 concrete masonry walls shall have a coating of stucco C-926 rebar in 8 inch U lintels only. applied in accordance with ASTM or other approved coating. 5. All safe loads in units of pounds per linear foot. 5. Concrete masonryunits used in composite U lintel shall 6. All safe loads are based on simply supported span. be laid in a running bond. 7. Safe load ratings based on rational design analysis 6. Shore composite lintels as required. per ACI 318 and ACI 530. 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical cell reinforcing and grout. � r al top ledca YW tlt Ilnt nNgmInd— rF— Y "o 81`16-1 B/1�IT r.�nCaaiGk �5 repro Ilnlal Df IMt4 wonky ttanM1e�uNl y ,jNyr�' J 9 C Lintel Tvoe Designation CONCRETE COLUMN SCHEDULE MARK SIZE REINFORCEMENT REMARKS VERTICAL CLOSED TIES C1 SEE DETAIL 1 SEE DETAIL 1 SEE DETAIL 1 C2 8"X2'-8" (8)-#6 #3 SPA. @ 8" C3 8"X2'-0" (6)-#6 #3 SPA. @ 8" C4 8"X1'-8" (6)-#6 #3 SPA. @ 8" NOTES: PROVIDE 2" CLEARANCE TO REINFORCING STEEL AT CONCRETE COLUMNS UNLESS NOTED OTHERWISE. PROVIDE STANDARD HOOKED DOWELS INTO SUPPORTING FOOTING OF SAME SIZE AND QUANTITY AS VERTICAL REINFORCING. LAP DOWELS 3'-0" WITH VERTICAL BARS AND EMBED HOOKED DOWEL 9" MINIMUM INTO FOOTING. PROVIDE STANDARD HOOKED VERTICALS INTO UPPER BEAM ABOVE OF SAME SIZE AND QUANTITY AS VERTICAL REINFORCING. EMBED HOOKED BAR 12" MINIMUM INTO BEAM ABOVE. Cast Crete Lintel Schedule COMDosite U Lintel Materials 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60. 3. Concrete masonry units (CMU) per ASTM C90 4. Mortar per ASTM C270 Type M or S All Rebar to be #5 Grade 60 min. MARK LENGTH GRAVITY GRAVIITY APPLIED ALLOWABLE UPLIIF1TA OAD UPLIFT LOAD BEAM SPECS. L-1 7'-6" 5681 1900 2426 — 8F24 1T/113 L-2 9'-4" 3486 1900 1815 — 8F24 1T/18 L-3 17'-4" 1609 1300 638 100 81`24 1T/1B L-4 10'-6" 2781 2300 1461 400 81`24 1T/113 L-5 4'-6" 8060 6700 3607 — 8RF22 1T/113 L-6 7'-6" 5681 2300 2426 400 81`24 1T/1B L-7 13'-4" 1838 400 964 100 81`24 1T/113 L-8 4'-6" 8672 800 4043 400 8F24 1T/1B L-9 5'-4" 7342 900 3399 500 8F24 1T/18 L-10 L-11 L-12 L-13 Mim. Beam depths shown, beams may be increased At Lintels 30" deep or larger, provide (1) #5 vertical rebar at 24 o.c. along length of lintel Worst loading case shown CONCRETE BEAM SCHEDULE MARK DESCR. SIZE REINFORCING REMARKS W x H, IN BOT TOP MIDDLE STI RUPS B81 MAS. 8X16 #5 #5 TB1 CONC. 8X16 (2)#6 (2)#6 B1 CONC. 8X8 (2) #5 (2) #5 - B 2 CONC. 8X24 (2) #7 (2) #5 (2) #5 #3 @ 10" O.C. B3 CONC. 8X24 (2) #7 (2) #7 (4) #7 #3 @ 12" O.C. B4 CONC. SEE DETAIL 2 SEE DETAIL 2 SEE DETAIL 2 SEE DETAIL 2 SEE DETAIL 2 B5 CONC. 8X16 (2) #7 (2) #5 #3 @ 5" O.C. B6 CONC. 8X38 (2) #7 (2) #5 (4) #5 #3 @ 15" O.C. NOTES: 1. PROVIDE 2" CLEAR TO REINFORCING STEEL UNLESS OTHERWISE NOTED. 2. ALL REINFORCING SHALL BE CONTINUOUS OVER COLUMNS. LAP BEAM REINFORCING WITH BOND BEAM OR TIE BEAM REINFORCING. FOOTING SCHEDULE SIZE BOTTOM TRANSVERSE REINFORCING TOP TRANSVERSE REINFORCING BOTTOM LONGITUDINAL REINFORCING TOP LONGITUDINAL REINFORCING MARK WIDTH LENGTH THICKNESS NO. SIZE SPA. NO. SIZE SPA. NO. SIZE SPA. NO. SIZE SPA. REMARKS TE1 8" CONT. 8" - - 1 #5 CENTER - - - WF1 1'-4" CONT. V-0" - - - - 2 #5 EQ. - - - WF2 3'-8" CONT. 1'-0" - #5 V-0" OC - - - 4 #5 EQ. - - - WF3 2'-8" CONT. 1'-0" - #5 1'-0" OC - - - 3 #5 EQ. - - - F1 4'-0" 4'-0" V-0" 4 #5 EQ. - - - 4 #5 EQ. - - - GENERAL STRUCTURAL NOTES: GENERAL: THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE ALONG WITH AMENDMENTS. MATERIALS AND SERVICES PROVIDED BY THE CONTRACTOR SHALL CONFORM TO THE ABOVE MENTIONED CODES AND THE CONTRACT SPECIFICATIONS. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE JOB CONDITIONS AND RESTRICTIONS. FOR DIMENSIONS AND DETAILS NOT SHOWN, REFER TO ARCHITECTURAL DRAWINGS. INSTALL ALL PRODUCTS PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. LOADINGS: ROOF LOADS: LIVE LOAD: 20 PSF (TOP CHORD LOADING) DEAD LOAD: 20 PSF (10 PSF TOP CHORD LOADING AND 10 PSF BOTTOM CHORD LOADING) FLOOR LOADS (INTERIOR): LIVE LOAD: 40 PSF DEAD LOAD: 40 PSF (INCLUDES PARTITION ALLOWANCE) FLOOR LOADS (BALCONIES): LIVE LOAD: 40 PSF DEAD LOAD: 125 PSF WIND LOADS: ULTIMATE WIND SPEED, 3 SECOND GUST: 160 MPH BUILDING CATEGORY: II EXPOSURE CATEGORY: D INTERNAL PRESSURE COEFFICIENT: +/-0.18 FOUNDATIONS: FOUNDATIONS, SLAB AND SITE PREPARATION SHALL SHALL CONFORM TO THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT PREPARED BY FEDERAL ENGINEERING & TESTING, INC. DATED MAY 6, 2019. THE CONTRACTOR SHALL EXERCISE GREAT CARE DURING EXCAVATION, UNDERGROUND UTILITY LOCATIONS ARE UNKNOWN. THE CONTRACTOR SHALL PREDETERMINE UTILITY LOCATIONS AND NOTIFY THE ENGINEER IMMEDIATELY IF A CONFLICT EXISTS. THE CONTRACTOR IS RESPONSIBLE FOR THE SAFE SUPPORT OF UTILITIES ACROSS EXCAVATIONS. FOUNDATIONS SHALL CONFORM TO THE SOILS REPORT PREPARED EIY FEDERAL ENGINEERING & TESTING, INC. DATED MAY 6, 2019. FOUNDATIONS HAVE BEEN DESIGNED USING AN ALLOWABLE BEARING PRESSURE OF 2,500 PSF. PROVIDE PIPE SLEEVES FOR PIPES PASSING THROUGH FOUNDATIONS AND PASSING BELOW FOUNDATIONS. MASONRY: MASONRY SHALL CONFORM TO ACI, LATEST EDITION. MASONRY SHALL DEVELOP A NET AREA COMPRESSIVE STRENGTH OF 2,500 PSI IN 28 DAYS. GROUT SHALL CONFORM TO ASTM C476, WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI IN 28 DAYS. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. VERTICAL REINFORCING LAP SPLICES SHALL BE 48 BAR DIAMETERS. MAXIMUM GROUT POUR SHALL BE 5 FEET, CONSOLIDATE BY MECHANICAL VIBRATION. ALL CORNERS ARE TO BE TIED BY MASONRY BOND. PROVIDE JOINT REINFORCEMENT SPACED AT 16" O.C. VERTICALLY. REINFORCING SHALL BE CENTERED IN CMU. PROVIDE REINFORCING STEEL AS NOTED ON THE PLANS. THESE BARS SHALL BE CONTINUOUS THROUGH LINTELS AND BEAMS. PROVIDE A STANDARD HOOK AT VERTICALS INTO BOND BEAM. GROUT MASONRY SOLID AT REINFORCING STEEL ONLY UNLESS NOTED OTHERWISE. PROVIDE DOWEL INTO FOOTING OF THE SAME SIZE, SPACING AND LOCATION AS VERTICAL REINFORCING ABOVE. PROVIDE 16" MIN. HEIGHT BOND BEAM SILL WITH (1)-#5 HORIZONTAL REINFORCING EACH COURSE DOWELED 6" MIN. INTO JAMBS UNLESS NOTED OTHERWISE. PRE-ENGINEERED WOOD TRUSSES: SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS DETAILING ALL TRUSSES AND TRUSS TO TRUSS CONNECTIONS FOR APPROVAL PRIOR TO FABRICATION. PROVIDE TEMPORARY AND/OR PERMANENT TRUSS BRACING AS REQUIRED TO SATISFY OSHA, THE DESIGN REQUIREMENTS AND PROVIDE ERECTION STABILITY. PROVIDE AT A MINIMUM 2X4 BOTTOM CHORD BRACING SPACED AT 6'-0" O.C. MAX. CONCRETE: CONCRETE SHALL CONFORM TO ACI SPECIFICATIONS, LATEST EDITION. REINFORCING SHALL CONFORM TO CRSI, LATEST EDITION. CAST -IN -PLACE CONCRETE SHALL DEVELOP A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI FOR FOUNDATIONS AND SLABS AND 4,000 PSI FOR BEAMS. ALL CAST-CRETE PRECAST CONCRETE LINTELS SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND SPECIFICATIONS. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. ALL REINFORCING BAR SPLICE LENGTHS SHALL BE CALCULATED IN ACCORDANCE WITH ACI UNLESS NOTED OTHERWISE.. SPLICES SHALL BE CLASS "B" AS DEFINED BY ACI UNLESS NOTED OTHERWISE. PROVIDE CORNER BARS AT ALL LOCATIONS WHERE REINFORCEMENT CHANGES DIRECTIONS OF SAME SIZE AND SPACING AS MAIN REINFORCEMENT. PROVIDE SAW CUT SLAB CONTRACTION OR CONSTRUCTION JOINTS SPACED @ A MAXIMUM OF 10'-0" O.C. IN BOTH DIRECTIONS WITH A MAXIMUM LENGTH TO WIDTH RATIO OF 2 UNLESS NOTED OTHERWISE. PRIOR TO PLACING CONCRETE COORDINATE LOCATION OF ALL SLAB PENETRATIONS WITH MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. SUBMIT CONCRETE MIX DESIGN FOR REVIEW AND APPROVAL PRIOR TO PLACEMENT. SUBMIT REINFORCING STEEL SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. PERFORM CONCRETE TESTING IN ACCORDANCE WITH ACI AND THE BUILDING CODE. STRIP FOOTING REINFORCING SHALL BE CONTINUOUS THROUGH SPREAD FOOTINGS. ,,s Ak, SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE #66080 0\\ NS o. 80 =_ STATE OF 1414 �9 r z O a J U Ln 0 w a 0 z 0 w K ~ J 0 LL w � zy pro C a Q Up JLL LU CL Vl LU O z `06 V W ui U U) DATE DESIGNED BIM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 S111111111117 �� e VrR dt 1-1/rV' 1-1/rV ev 11-1/2-V 2-1 Ir 1-1/2"V 3 3 WC 3* e 2• 3- LAV W, i 2- Ln SHWO 2' LAV TUB 4"V 1-1/rV LAV 3'V 1-1 /2" ev 1-1/2"V rV LAV 2'V I-1/rV SHWR rV 2- 1-1/rV e 1-1/ry LAV 4' 2- C 1-1/rV e 1-1/2• 1-1/2-V 3- V LAV WC 1-1/2-V SHWR -u 2 WC ev 2STUDOR VENT KITCHEN SINK 4" 2" 3"v 2-1/2•V- 4-V rV A - 1/2V 1-1/rV LAV� 1-1/2"V 1-1/2'V 4- TO SANITARY WC SYSTEM 3 SHWR IA L2-1/2' 1-1/2" PLUMBER RISER DIAGRAM NOT TO SCALE PLUMBER TO LOCATE SEWER AND WATER CONNECTIONS PLUMBIN(3 NOTES: Fllumbr I I i with cantr-.7o-4or any equiprrem orcered for r,0UC1- in mr--l-nsIons. Verify c-l'; dimensions vvitrl th,e floor Dian. 7,je floor pian dirnensiQms dl'ctauc-; rill ot'n-., dimensions or) other ,;heets, Do not slcde d-cwinrj, if cry conflicts crise, Contact the Arcir I itecl- 0/- Ingiriee, -'()K Prior to CiDnshr-,-ti0n. Ali sanitcry, 2" or :ess shol. 1-cvc a slope of 1/4" per foo- ry)'nirnurn' Ad sonar c.,y ',nes at 2" slhail hove a slope of /8" per foot rninirnurn. Provice 4-itli Slcaldillg Valve 'In oil showers, Low'esf i,Ariq arec F�oo, elevcion (referee as CWO') to be set by r)rof s'ond no, osuor ��o the rvey, building d e- p a rt rr, e n ' � ezevctor', out not less than i8"required above tne crown of 'he .""�)C. , �, -, �s mh, S U MM IT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE #66080 N 0 TA'OF '4u 4,1 z 0 u U) uj Lu z 0 R V) Lu DATE DESIGNED BJM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 I FILE FIRST FLOOR MECHANICAL PLAN SCALE- 1/4" = 1'-0" SECOND FLOOR MECHANICAL PLAN SCALE- 1/4" = 1'-0" ,,SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN 1. MASKOL FL PE #66080 !!!l11111111///7/ 60 *e E OE lop' z O a uU Lu w w H Q Z O w 00 ~ J � L .w ~U OW a Q� UC �LL J W DATE DESIGNED BIM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 CU-1 CU-2 MINI -SPLIT 1 MINI -SPLIT 2 THIRD FLO MECHANICAL PLAN SCALE- 1/4” = 1'-0" CONDENSING UNIT SCHEDULE: MANUFACTURER MODEL NO. AMBIENT TEMP. TONNAGE POWER M.C.A. M.O.C.P. WEIGHT NOTES MITSUBISHI MXZ-5C42NA2 MITSUBISHI MXZ-3C30NA2 MINI -SPLIT UNIT SCHEDULE: MANUFACTURER MODEL NO. NOM. CFM I KW I POWER M.C.A. M.O.C.P. WEIGHT NOTES MITSUBISHI MSZ-GL09 > MITSUBISHI MSZ-GL12 MECHANICAL NOTES FURNISH AND INSTALL MECHANICAL SYSTEMS TO MEET ALL CURRENT REQUIREMENTS OF NATIONAL, STATE AND MUNICIPAL CODES, RULES, REGULATIONS, LAWS, AND §TANDARDS AS THEY ARE ADOPTED BY THE GOVERNING AGENCY AND AS THEY MAY APPLY, THE MECHANICAL WORK INDICATED ON THIS PLAN SHALL COMPLY WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODES: RESIDENTIAL, BUILDING, MECHANICAL, PLUMBING, ACCESSIBILITY, ENERGY CONSERVATION, THE FLORIDA FIRE PREVENTION CODE, UNDERWRITERS LABORATORIES (UL) AND THE STANDARD FOR THE INSTALLA11ON OF AIR CONDITIONING AND VENTILATION SYSTEMS, NFPA 90A. SECURE AND PAY FOR ALL PERMITS AND LICENSES BEFORE ACTUAL WORK IS STARTED AND OBSERVE ANY REQUIREMENT STIPULATED THEREON. COORDINATE WITH AND GIVE ALL NECESSARY NOTICES FOR INSPECTION OF THE WORK TO THE GOVERNMENTAL AUTHORITY HAVING JURISDICTION. COORDINATE LOCATION OF AIR DEVICE WITH ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED CLEARANCE TO SMOKE DETECTORS. CONSTRUCT DUCT IN ACCORDANCE WITH SMACNA REQUIREMENTS. VERIFY DUCT TIGHTNESS IN ACCORDANCE WITH THE FLORIDA ENERGY CONSERVATION CODE. TESTING SHALL BE IN ACCORDANCE WITH APPUCABLE SEC11ONS OF ASHRAE STANDARD 152. PROVIDE AN UNCONDITIONAL, ONE (1) YEAR WARRANTY FROM DATE OF SUBSTANTIAL COMPLETION ON ALL PRODUCTS AND WORKMANSHIP PROVIDED FOR THIS PROJECT. „SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN ]. MASKOL FL PE #66080 Ng P5E} �404 z O a u V Lu w 0 W 0 z O W 00 F_ ®Lj_ 1 �W z u � DC ®w 1__� z � Q UO 1—ELL uj CL qz J W Q® IU#-# z z <z U W W clL pw LL ( ^V v/ L M DATE DESIGNED BJM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 ...SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN 1. MASKOL FL PE #66080 \!!l\ePN J. � ! i N p . ST EOF\ IOIfj �1110, z O a r4 U w O H Q Z O .. 5 w a' 0 LL_ ®J Lu LL ®I r- u ti-^I L.L C> w Q CL U® JLL LLJ m DATE DESIGNED BIM 02-23-21 DRAWN MIN 02-23-21 CHECKED JOB NO. 2021-062 ELECTRICAL LEGEND WARMER FAN OUTLET VP VAPOR PROOF SURFACE MOUNTED LIGHT FAN OUTLET EXTWF EXTERIOR LIGHT WALL FIXTURE ® RECESSED LED LIGHT FLUORESCENT FIXTURE INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN rc EST FAN OUTLET =49� DUPLEX�QUTLET BOOK 220 V OUTLET .CFI GROUND FAULT INTERRUPTER $AcFl WEATHER PROOF GROUND .FAULT ® CARBON/SMOKE DETECTOR C/S SWITCH 3. WAY SWITCH p. PUSH BUTTON NOTE: RECEPTACLES 1N KITCHEN & BATH AREAS TO BE 46" A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF REC PTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AM BRANCH CIRCUITS T CEILING FAN WITH LIGHT SCALE- 1/4" = 1'-0" Electrical Load Calculations 4988 Living S.F. at 3 VA 14,964 VA (2) Two 20 Amp Appliance, Ckts: 3,000 VA Laundry 1,500 VA Dryer 5,000 VA Dishwasher 1,200 VA Range 12,000 VA Disposal 900 VA Microwave 1,200 VA Garage Door Opener 1,800 VA Ref. Circuit 1,200 VA Water Heater 4,500 VA Well Pump 1,900 VA Pool Pump 1,900 VA (6) Ceiling Fans ® 400ea. 2,400 VA Tankless Water Heater 13,000 VA (2)-Tesla Wall Chargers 24,000 VA Towel Warmer 200 VA Total 90,664 VA First 10 KVA at 100% 10,000 VA Remainder at 40% 32,266 VA Total 42,266 VA AHU1 AC Heat at 100% 11,000 VA AHU2 AC Heat at 100% 7,000 VA Total 60,266 VA 60,266 VA / 240 V = 251.0 Amps 400 Amp NEW Service Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified 600 mcm copper and (1) 1/0 ground (THW) copper in 3" galy. conduit Wall Panel: 400 A.M.C.B. 400 amp meter 1 0, Circuit Main House O main combo 120/24 V0 Volt Panel a.c a.c disc. isc. Grn d. 5/8" dia. x 10'-0' F.P.L. service long ground rod Underground 3/4" copper I water pipe e' tie ground wire to footing rebars Electrical Riser Dicaram S U M MIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE #66080 HII T * OF �4 li Z O E CC U In w 0 H Q Z O L w K N W ® � r zv/ H �+ O W I..L U0 I- II LL J W CL DATE DESIGNED BJM 02-23-21 DRAWN MJN 02-23-21 CHECKED JOB NO. 2021-062 E11111111112