Loading...
HomeMy WebLinkAboutBuilding PlansBUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WIND W 4 PRODUCT MODEL " MANUFACTURER ATTACHMENT METHOD BUILDING DESIGN PRESSURE EXPIR. DATE TYPE, SIZE, SPACING 4 EMBEDMENT APPROVAL" EVALUATION AGENCY RO RE GN PRESSURE 3/16" x 2 314" TAPCONS / "12 HEAD MI WINDOWS 4 DOORS a' EVERY HOLE. (HEAD 4 SILL) 10" WINDOWS 185 SH SERIES O,C. 4 2" FROM CORNERS (VERT) +40.5 / -54.2 10/I f/23 MIAMI / DADE (SINGLE HUNG) (IMPACT) 10" O.C. MAX 4 2" FROM CORNERS +55.0 / -55.0 FL-11499.1 (1 1/4" MIN. EMBED) (WORST CASE) 3/16" x 2 3/4" TAPCONS / 012 HEAD M.I, WINDOWS 4 DOORS 6 EVERY HOLE, (HEAD 4 SILL) 10" WINDOWS 185 PW SERIES O.C. 4 2" FROM CORNERS (VERT) +40.5 / -54.2 04/03/2023 (FIXED GLASS) (IMPACT) 10" O.C. MAX 4 2" FROM CORNERS +60.0 / 400.0 FL-15349,1 MIAMI /DADE (1 114" MIN. EMBED) (WORST CASE) 114" x 2 3/4" TAPCONS / 012 HEAD THERMA-TRU (HEAD) (2) 4" FROM CORNERS FRENCH DOOR COMP, EDGE (IMPACT) (VERT) 16" O.C, MAX TO +40,5 / -43,9 N/A MIAMI 1 DADE (FIBERGLASS) FIBERGLASS GLAZED BUCK 4 4" O.0 FROM / +50,0 -50,0 FL-20468.1 CORNERS (1 1/4" MIN, EMBED) 1/4" x 2 314" TAPCONS / 4012 HEAD MI WINDOWS 4 DOORS (HORIZ.) 16" O,C. MAX 4 6" FROM SIT. GL. DR. SERIES 100 CORNERS (VERT) 20" D.C. MAX TO +40,5 / -43.9 11/29/2021 (IMPACT) MIAMI / DADE BUCK 4 10 O.0 FROM +55,0 / -55.0 FL-22401.3 CORNERS (1 1/4" MIN. EMBED) MI WINDOWS 4 DOORS 1 1/2" x 1/4" TAPCONS AT EACH HOLE WINDOW 1"x4"x.375" W/ I I/4 MIN, EMBED. 4 +40.5 / -43.9 12/31/2019 3RD PARTY MULLION ALUMIN. TUBE 2 I/2 MIN. EDGE DISTANCE +50.9 / -50.9 FL-15353,3 1/4" LAG SCREWS a 6" GARAGE DOOR STEEL SECTIONAL DAB DOOR COMP. FROM ENDS AND 9" O.G. +35,5 / -39. N/A 3RD PARTY INSULATED (IMPACT) MAX. PROVIDE 1 1/2" MIN. EMBED. +36.0 / -44.0 FL-153TI.2 (EACH BRACKET) 114" x 2 314" TAPCONS / 012 HEAD PANEL DOOR FIBER -CLASSIC THERMA-TRU (HEAD) (2) 4" FROM CORNERS +40.5 / -43,9 N/A (SINGLE) OUTSWING - IMPACT (VERT) 16" O.C. MAX TO +50,0 / -50,0 FL-20465.1 3RD PARTY BUCK 4 4" O,C FROM CORNERS (1 1/4" MIN. EMBED) PRODUCT MODEL " MANUFACTURER ATTACHMENT METHOD BUILDING DESIGN PRESSURE EXPIR. DATE TYPE, SIZE, SPACING 4 EMBEDMENT APPROVAL" EVALUATION AGENCY PRODUCT DESIGN PRESSURE ROOFING OWENS CORNING USE 6 NAIL PATTERN. SPACING PER +23,4 / -95,7 0"1/19/2021 (ASPHALT SHINGLE) DURATION MANUF. SPECS. SEE NAILING PATTERN TAS I10 16-0425,01 MIAMI / DADE SHEET 3, NA +18.1 / -25.5 NA STUCCO NA STUCCO ON MTL. LATH NA MIAMI / DADE v m GENERAL NOTES: I. VERIFY LOCATION OF UTILITIES W/ SUBDIVISION BEFORE PROCEEDING WITH WORK, 2, CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS OR EASEMENTS ARE ENCROACHED. (OWNER, 4 OR CONTRACTOR, IS RESPONSIBLE FOR PROVIDING SETBACKS, EASEMENTS, LOT COVERAGES, ETC.) 3. PROVIDE ACCESS TO ALL CONCEALED PLUMBING SLIP JOINTS, 4, PROVIDE EGRESS WINDOW UNIT AT BEDROOMS. 5, DO NOT SCALE DRAWINGS, USE WRITTEN DIMENSIONS. 6, PROVIDE PVC SLEEVES AS REQUIRED AT DRIVEWAY AND SIDEWALKS FOR LANDSCAPE LIGHTING AND IRRIGATION. 1. VERIFY A/C UNITS SEER WITH ENERGY CODE, 8, USE TEMPERED GLASS AT ALL HAZARDOUS AREAS, S, USE MOISTURE RESISTANT DRYWALL AT WET AREAS, 10, SURVEYOR SHALL VERIFY ALL SITE DIMENSIONS, EASEMENTS 4 SETBACKS PRIOR TO ANY CONSTRUCTION AND SHALL IMMEDIATELY CONTACT 4 NOTIFY ARCHITECT IF ERRORS OR PROBLEMS ARISE. 11. OWNER 4 OR CONTRACTOR IS RESPONSIBLE FOR PROVIDING DESIGN GUIDELINES AND RESTRICTIONS PER SUBDIVISIONS ARCHITECTURAL REVIEW BOARD. 0 0 5,' 4" 20' 5" 18, 01, 8' 41,4" 12' Ol4" 8" 16' O" 1' 4" 31 0" 15, it" 5/8" SM. STUCCO ON SH 25 _ 16" x 8" x 16" BLK. COL, 5' (SEE ELEV.) IN EG SS -O' 5" FIN. F - I I I I B" 31 B" COVERED EDROOM *4 CLG. HT. :PET 0 Y 0 W= BEDROOM *2 n x O N �7= 9'4" CLG. HT. „ W CARPET 7 42 2' 8" PKAF II I /m-z- N N X1-0 W SEDF n � = xW N „l9'4" CLG. HT. CARPET 8" m 9'4" CLG. HT, CONIC, FL, 4" FIN, Flll B' e" CONC. 5LAB (2) SH 25 6' 2" x 5' 3" 22' ," EGRESS 14' p" 2' 4" 19' all ; 1 1 I i , 2 0" I ; (TYPJ 1 � ; 3L DISP.I. SINKMASTER ' o SUITE a s u- O GREAT ROOM CARPET HT. Q I , TILE FL. , 1 ; I 1 N 1 1 1 , 1 1 1 O � 1 � 1 c r 0 � , w.I.e. 5 03' 4" 5' 0' � i1 'O" FIN. FL. ' 4" 4" 4" R!SVT Rtg_- _____________ ' VTR m 13' 8" _ _ _ _ _,IO' pll _ _ " • _2"- El --FO`t'ER 0 5 H MASTER 5ATH SV 0 TILE CLG. HT, TILE FL� HT 14' O m a LL 2' O" 18' O" l' B' I' B' r 6' O" RECESS S W DINING 10 FR. DRS, W/ RECESS 9'4" CLG. HT. 'B" TRANS ABV, v. N TEMP. GL. ON TILE FL = 42" 1/2 WALL RAIN 2' N 3' 4" 2': I" 1 1 1 6' O" STUB GAS LINE FOR FUTURE USE IL X 0 0 0 Y £ W f O � ' > v K 1 1 1 ITCHE 1 1 n1 �Qn ; 2' 0" PANTRY /y v M 03 a LAUNDRY- r �14�wtde� x �p 10'0" CLG, HT. II pull down .{ N in 9' O" I _4 "4 •t - I ot SPRINKLER PUM 0 AC COND. q r'F BATT. INSUL. ro� H!C l20 MIN RATING . DOOR AND FRAME 3 FIN. FL. W/ HAGER SPRING O INGE C 302.5 p N QUAL 3' O" v // PER FBC R302.5,U o ENTRNr d lf8" CLG. HT, El l 212".V311 2'2"x5'3" I I N TILE ^', W.N. SH 1435 SH H35 SH H35--- - - - - -- 2' O" 3,1" 3' ," 1' 10" - 94 II pull down, Tr ip -0'4" FIN. F , 19' 4" a NOTE: (RB02,5.2) ul DUCTS IN GARAGE AND DUCTS PENETRATING THE p WALLS OR CEILINGS SEPERATING THE DWELLING m 11 FROM THE GARAGE SHALL B£ CONSTRUCTED OF A MIN, NO, 26 GAGE SHEET STEEL, I" MIN. RIGID 0 NONMETALLIC CLASS O OR I DUCT BOARD, OR OTHER -01 APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO GARAGE. z GARAGE ' 9'4" CLG. HT, i 1/2" GYP, BD. ON 2x FRAME WALLS ' AND 5/8" STUCCO ON BLK. WALLS IN GARAGE 5/8" GYP, BD, CL'G, W/ KNOCK-DN. FINISH -O'r." rIN, F � i 16'O"x8'0" 0.1 ,D, 11. 0" 1' 4" 3' 6" 3' 6" '0 4' 5" x 5' 3" SH 35 is pBSC. TEMP, GL. EC. STONE ON x I6" ELK, COL YP. OF 2 PLACE,') EE ELEVJ 4�� AREA CALCULATIONS A/C Space 2226 S.F. Garage 435 S,F. Entry porch 51 S.F. Rear porch 203 S,F. Total Non A/C (099 S.F. Total Under Roof 2915 S,F, * Contractors to verify all footagee • All areas are calculated to outeide dlmenslom O U) B" TEMP. GL. TO FL. 0 n z� mp z� z �• Wan Q m -6 0 0a. OQn i Q 9 = N~ N m w� uW�u�a O U VOW' W d� (I> �R O m O dv3 c m •s�dm O£ DATE 015/21/20 DRAWN BY: p)g me CHECHED MC REVISIONS 20' 8" 10' 4" 121411 11011 ]FL001iR1\\\,. PLAN REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC FA71 N I/8" W x I" DEEP SAWCUT m 30' O.C- MAX, (WITHIN 24 HOURS OF POUR - DO NOT INTERRUPT MESH) x—x—x�—x—x METAL KEY - FORM BY KEYHOLE) INC. OR EQUAL (STOP MESH) CONSTRUCTION JOINT CONTROL JOINT mr A Tm 1rjfO%%1ri\Trl 1r%,,"rIM A IM r9 ®A VV_'A 9 NOTE: CONTROL JOINTS/CONSTRUCTION JOINTS SHALL CREATE PANELS OF SOO S.F. (MAXIMUM) SEE FOUNDATION PLAN FOR SLAB DETAILS — SLAB RECESS (6" MAX. STEP DIi x 1211 105 BAR CONT. SEE FOUNDATION PLAN FOR SLAB DETAILS WD, BRG. WALL SLAB RECESS (6° MAX. STEP ON.� /x—x— x 0 0 Ail x — x II®�9®Ia PROVIDE PREFAB. "L" JOINT REINFORCING AT ALL CORNERS —x ..x.............--1 05 - AR uxx.uuu.....� STRUCTURAL NOTES CONTRACTOR NOTE: THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, TI CORSON B ASSOC, INC. IS NOT RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION OR FOR RELATED SAFETY PRECAUTIONS AND PROGRAMS, CODES AND STANDARDS COLUMN SYMBOLS 8 x 8 GROUT FILLED CELL WITH 1 05 VERTICAL BAR ■ 8 x 16 BLOCK COLUMN WITH ■ 2 05 VERTICAL BARS IN FILLED CELL 45 DEGREE BLOCK COL. �2 05 BARS VERT, IN IN FILLED CELL NOTE: FILL CELLS SOLID ON BOTH SIDES OF EVERY OPENING TYP. PROVIDE PREFAB. "T" JOINT REINFORCING AT ALL �id'�1.L� T-INTTERRyV�llLeSECCTIIO'N5 P1L.W MASONRY EXTEND JOINT RENF.6"N �r PROVIDE DOVETA IN70CCONCRETE Got MANCHOR SYSTEM PLdu VmV PL)uq VmTE (MASONRY LAID BEFORE COLUMN) (MASONRY LAID AFTER COLUMN) 7C5Y =CAL MALSONRY DETAILS 3/4VVO1 90 YI I. ND LOADS ARE PER ASCE 1-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, FOR A 0 MPH WIND SPEED (3 SEC GUST), EXPOSURE C, INTERNAL PRESSURE COEFFICIENT (CLOSED STRUCTURE) 0,18, IMPORTANCE FACTOR, AND BUILDING CATEGORY II, 2. THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE: D A FLORIDA BUILDING CODE 2020 (1TH EDITION) +�13. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) C, SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-05) D. MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315-99) E. NATIONAL DESIGN SPECIFICATION, WOOD CONSTRUCTION NDS/199T EDITION. 3, ARCHITECTURAL AND MECHANICAL DRAWINGS: A. THE STRUCTURAL DRAWINGS ARE PART OF THE CONTRACT DOCUMENTS AND DO NOT BY THEMSELVES PROVIDE ALL THE INFORMATION REQUIRED TO PROPERLY COMPLETE THE PROJECT STRUCTURE. THE GENERAL CONTRACTOR SHALL CONSULT THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND COORDINATE THE INFORMATION CONTAINED IN THESE DRAWINGS WITH THE STRUCTURAL DRAWINGS TO PROPERLY CONSTRUCT THE PROJECT, B. BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS TO PROPERLY SIZE OR FIT THE WORK, NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED BY THE OWNER RESULTING FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT. C. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH ANY WORK. 4. ALL DETAILS, SECTIONS AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE SHOWN, FOUNDATION L BOTTOM OF FOOTINGS ASSUMED TO BEAR ON SOIL CAPABLE OF SAFELY SUPPORTING 2500 PSF. 2. TOP OF ALL EXTERIOR FOOTINGS SHALL BE MINIMUM 1'-0" BELOW EXTERIOR FINISH GRADE, 3. ALL EXCAVATION SHALL BE KEPT DRY. EXCAVATE TO DEPTHS AND DIMEN5ION5 INDICATED. TAKE EVERY PRECAUTION TO GUARD AGAINST ANY MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES, UTILITIES, PIPING, ETC, 4, PROVIDE ANY BRACING OR SHORING NECESSARY TO AVOID SETTLEMENT OR DISPLACEMENT OF EXISTING FOUNDATION OR STRUCTURES, 5. CENTERLINE OF FOOTINGS: SHALL COINCIDE WITH CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED ON DRAWINGS. 6. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE VERIFIED AND COORDINATED WITH THE ARCHITECTURAL DRAWINGS BY THE CONTRACTOR BEFORE PROCEEDING WITH THE CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER IN WRITING BEFORE PROCEEDING WITH ANY WORK. CONCRETE I. ALL CONCRETE SHALL BE READY MIX AND MEET THE FOLLOWING REQUIREMENTS: A. A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI s 26 DAYS, B. SLUMPS SHALL BE 4 INCHES MINIMUM AND 6 INCHES MAXIMUM, C, CONCRETE SHALL HAVE A MINIMUM OF 3 PERCENT AIR ENTRAINMENT. D. ALL CONCRETE TO HAVE MAXIMUM WATER/CEMENT RATIO OF 0,55. E. J0561TE WATER SHALL NOT BE ADDED. 2. CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS REQUIRED BY ACI SPECIFICATIONS. 3. ALL BARS SHALL BE LAPEL) PER THE REQUIREMENTS OF ACI 318 FOR TENSION LAP SPLICE BUT NOT LESS THAN 48 BAR DIAMETERS UNO, LAP ALL WWF A MINIMUM OF 12 INCHES UNO. 4, ALL HOOKS SHALL BE PER ACI 316 HOOK REQUIREMENTS BUT NOT LE55 THAN 12 BAR DIAMETERS BEYOND BEND UNO. 5, WELDED WIRE FABRIC SHALL COMPLY WITH ASTM A 155. PLACE WELD WIRE FABRIC 2" CLEAR FROM TOP OF THE SLAB IN SLAB ON GRADE AND SUPPORT ON SLAB BOLSTERS SPACED AT 3'-0" O.C, 6, ALL REINFORCING STEEL SHALL BE MANUFACTURED FROM HIGH STRENGTH BILLET STEEL CONFORMING TO ASTM DESIGNATION A 615 GRADE 60. 1, AT CORNERS OF CONCRETE BEAMS AND CONTINUOUS WALL FOOTINGS, PROVIDE MATCHING HORIZONTAL BARS X 5-0" BENT BAR FOR EACH HORIZONTAL BAR SCHEDULED AT EACH FACE. MASONRY I. MASONRY UNITS SHALL BE A. LOAD BEARING ASTM C 90, NORMAL WEIGHT, AND SHALL BE LAID IN A FULL BED OF MORTAR IN RUNNING BOND (UNO). 2. THE COMPRESSIVE STRENGTH OF MASONRY (F'M) SHALL BE 1,500 PSI AS CALCULATED IN ACCORDANCE WITH ASTM C1314, 3. ALL MORTAR SHALL BE IN ACCORDANCE WITH ASTM SPECS, C210 TYPE M OR S ONLY, 4. GROUT SHALL BE HIGH SLUMP MIX IN ACCORDANCE WITH ASTM SPECS. C41Fi AND HAVING A MIN. COMPRESSIVE STRENGTH OF 3,000 PSI 5. PROVIDE 8"x8" MASONRY BEAM WITH I "5 CONT. AT EVERY WINDOW SILL. EXTEND BEAM B" BEYOND EDGE OF OPENING, 6, PROVIDE HOT DIPPED GALVANIZED LADDER TYPE HORIZONTAL JOINT REINFORCEMENT (9 GA,) AT 16" O.C. VERTICAL IN ALL MASONRY WALLS PROVIDE DOVE TAIL SLOT ANCHORS AT CONCRETE COLUMNS. 2" X b" P.T WOOD BUCK FOR T'-O" HIGH DOOR W, REDHEADS EQUAL SPACw ANL W1Ir-lN 12" OF EA. END (5 BOLTS FOR &'0" HIGH DOORS) GARAGE DOOR ANCHOR DETAIL CONCRETE COLUMN v ro V r 51' 4" 20' 5" IS, O" 8' 419" 12' ONz" 8' 6' O" 1' 411 31011 16" x B" x 16" BLK, COL. W/ 3 05 BARS VERT. r - - - - no T ■ I I ■ ■ I 1 v I — — — — — — -0— — — — — — — — — — — — —I — — ■ — I— � _ r — — — — — — — — — — — — — — — — — — — — — — — — I I I I I I Ir a ` — — — — ' 42"x42"x12" D. I I I GONC, PAD I I I (L O I BELOW COL. I I m I W/ 05 BARS a I I 6" O.C. EA, WA'1. 1 12"11.1. x 12"D. CONC. THK'D EDGE W/ p I 1 (1) 05 BARS CONT. (TYP." � 18" D x 16W CONC. MONO. FTC. W/ I I 1 2 05 BARS CONT. (TYP.) I I 1 I I N I 201 1" 1 [r I -0 '4" FIN. FL, 1 u - - - - - - - - - - - - - - - - - - - - - - - - - - '- 1 2 •5 BARS it LONG I SGD RECESS MID -DEPTH OF SLAB (TYP. 4 PLACES) I I L _________________________________________________- _\\t I 1 I 0-0' FIN. FL, I , l I I III III `ill JL I I I 1 rr hi l 1 o p Ir =kli 1 1 � 1 o Ill — - r� r ul-- J 1 i , I ! REF. K 4"(3000 PSI) CONC, SLAB W/ 6x6 10/10 WWF ON 6 MIL. POLY VAPOR BARRIER II I ON WELL COMPCTED TERMITE TREATED 1 I ' 3'11" GLEAN FILL. (ALT. FIBER -MIX CONC,) 1 I I L _--_J_______ VTR I I I I I 1 I VTR I 1 I `-- - ---- 2"x12" THK. EDGE- SLAB RECESS W/ I 5 BAR CONT. I 1 S' 2" 2' r l I I I r 1 O'O" FIN. FL, 18" D x 16" W CONC. MONO, FTC. W/ - - - - - - - - - - -I �e" 0 O — SHWR. _ — 2 05 BARS CONT, (TYP. I DR. RECESS 1 RECESS � RrC � O I 12"xl2" THK. EDGE 1 1 � "' I 11 511 SLAB RECESS W/Al 3A, FIN F . - I ��� 11 2' 0 3' 6' I "5 BAR CONT, I I 1 9 O 101411 O I I 1 A O I r _ _ _ _ _ _ _ _ _ _ _ _ — - ___________J W L - _ J OPT, rF-- ir --_I F I us n- d SPRINKLER _ 11 I D I II W I rr ll I__ O _ _ _ rl\= _ _ r m O PUMP FLI___ j41. _ _ _ _ _ _ F _ L.T. IUI_- T- ,rr - - " AHu/ I I 2 OII 31 111 3 I' lb" ■■ - - - - - - ■■ I v W �- \ JL ■ 13/4" FIN. FL. ■ I = r - VI - vrte - - e/ ., CONC, PAD BELOW CO L'S I I " x 16" BLK. COL z All 1 W/ 05 BA S O 6" O.C. EA, - - ' L - - _ ' W/ (4) 05 BARS - - U - - I g' 4" 1O' O" 1 Ill II 411 3' 6" 3' 6" (TYP. CIP 2 PLACES) I' 4" VEI*t.4A FILLED C LS, 91 611 v III�;� ,III 4 FIN, F I 12" x 12" THKD EDGE I I W/ I •5 BAR CONT, I I I I I Z I Q I O Q I (L I I m I I - I I O I - I � I I I I 18" D x 16" W CONC. MONO, FTG. W/ 1 2 •5 BARS CONT. (TYP. I I I I I I I I I I I I I I -O' 6" FIN. FL. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ GARAGE DR, RECESS O.H.D. 101411 20. 8.1 12' 4" 1loll 111 411 51' 4" 71FOUNDATHON PLAN Avv=-90" ■ Li am O r REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC z m $ z (1 z S " W oR N�6'p-, N- a lU a S IL 111 0 U rza Z�`��mm`mzo N= Irm w v Q N fl- a0� 8m "�`o.,, �O (L q r o 0 Q J Q m 3 & U L 4 m �` m m 3 3 1 m DATE 08/21/20 DRAWN BY: pJ9 me CHECKED : MC REVLSION3 : STRUCTURAL NOTES CONTRACTOR NOTE: THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. M.A. CORSON t ASSOC. INC. IS NOT R£8PONSI5LE FOR THE MEANS AND METHODS OF CONSTRUCTION OR FOR RELATED SAFETY PRECAUTIONS AND PROGRAMS, WOOD L ALL STRUCTURAL WOOD MEMBERS ARE DESIGNED AS "DRY -USE" MOISTURE CONTENT MUST BE le% OR LESS, STORE WOOD FRAMING ABOVE GROUND AND UNDER TARPS WITH PROPER AIR CIRCULATION 2, ALL LUMBER SHALL BE SOUTHERN PINE SPECIES 02 GRADE OR APPROVED EQUAL. ALLOWABLE DESIGN STRESSES SHALL FOLLOW NATIONAL DESIGN SPECIFICATION (NDS) (LATEST EDITION), 3. PROVIDE SP ACQ PRESSURE TREATED LUMBER IN ACCORDANCE WITH AWPA STANDARDS TO A MINIMUM 0,40 PCF RETENTION WHERE LUMBER 18 IN CONTACT WITH CONCRETE/MASONRY OR OUTSIDE OF BUILDING, ALL METAL CONNECTORS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE GALVANIZED WITH A RATING OF G-185 AND CONFORM TO ASTM A653. ALL NAILS AND SCREWS USED WITH PRESSURE TREATED LUMBER ARE TO BE HOT -DIPPED GALVANIZED AND TO CONFORM TO ASTM A153 CLASS D. ELECTROGALVANIZED FASTENERS SHALL HAVE A CLASS RATING PER ASTM 5695 NO LESS THAN 55. ALUMINUM NOT TO BE USED IN DIRECT CONTACT WITH ACQ TREATED LUMBER, 4. PLYWOOD SHEATHING: A. ROOF: USE IS/32" APA 40/20 RATED, EXP. I, PLYWOOD SHEATHING, B. SEE FRAMING PLANS FOR NAILING AND/OR BLOCKING REQUIREMENTS. USE a'- O" LONG X 4'-0" WIDE SHEETS WITH LENGTH ACROSS FRAMING, STAGGER PANEL END JOINTS 4'-0" TYP., ALLOW 1/8" SPACE ALONG PANEL EDGES AND END JOINTS, 5, WOOD CONNECTIONS - ALL NAILS USED FOR STRUCTURAL FRAMING MEMBERS SHALL BE COMMON WIRE, U.N.O. ALL NAILS, TRUSS HANGERS, TRUSS ANCHORS AND STRAPS SHALL BE GALVANIZED FOR CORROSIVE RESISTANCE. ALL METAL STRAPS MUST BE INSTALLED WITH EQUAL LENGTHS ABOUT THE JOINT LINE. USE SIMPSON STRONG -TIE CONNECTOR PRODUCTS OR APPROVED EQUAL. TOE NAILING WILL NOT BE PERMITTED, WOOD TRUSSES I. WOOD ROOF TRUSSES ARE TO BE DESIGNED FOR THE WOOD FABRICATOR BY A PROFESSIONAL SPECIALTY ENGINEER REGISTERED IN THE STATE OF FLORIDA. SEALED CALCULATIONS AND LAYOUT DRAWINGS ARE TO BE SUBMITTED FOR APPROVAL. TRUSS FABRICATOR TO PROVIDE ALL TRUSS -TO -TRUSS HANGERS AS REQUIRED TO RESIST GRAVITY AND UPLIFT REACTION 2, WOOD TRUSSES SHALL BE BRACED AND ERECTED IN ACCORDANCE WITH THE "TRUSS PLATE INSTITUTE" HANDLING, INSTALLING AND BRACING OF WOOD TRUSSES: COMMENTARY AND RECOMMENDATIONS, NIB (11213IMTION). BRACING IN THE PLANE OF THE WEB MEMBERS: A. THE TRU55 FABRICATOR SHALL PROVIDE AND LOCATE CONTINUOUS LATERAL BRACING FOR EACH TRUSS WEB MEMBER AS REQUIRED, B. LATERAL BRACING SHALL BE RESTRAINED BY DIAGONAL BRACING (MIN. 2" THICK NOMINAL LUMBER). THIS BRACING 18 TO BE CONTINUOUS. C, A MINIMUM OF TWO ROWS OF DIAGONAL BRACING IS REQUIRED, ONE AT EACH VERTICAL WEB MEMBER CLOSEST TO BEARING LOCATIONS, 3. THE BOTTOM CHORDS SHALL BE BRACED BY CONTINUOUS LATERAL BRACING SPACED AT W-O" ON CENTER WITH A CEILING ATTACHED TO BOTTOM OF TRUSSES, IF NO CEILING IS ATTACHED TO BOTTOM OFTRUSSES, BRACING SHALL BE MINIMUM 2X4 e 36" ON CENTER NAILED TO THE TOP OF THE BOTTOM CHORD. DIAGONALS PLACED AT 45 DEGREES TO THE LATERAL BRACES SHALL BE LOCATED AT EACH END. IF BUILDING EXCEEDS 60 FEET IN LENGTH, DIAGONAL BRACING SHOULD BE REPEATED AT 20-FOOT INTERVALS. 4, DO NOT CUT, DRILL OR NOTCH TRUSSES WITHOUT WRITTEN APPROVAL FROM TRU55 ENGINEER. COORDINATE MECHANICAL, ELECTRICAL, PLUMBING, ETC, SIZES AND LOCATIONS WITH TRUSS LAYOUT PRIOR TO ERECTION, 5, TRUSSES SHALL BE MANUFACTURED 6 DESIGNED IN ACCORDANCE WITH NATIONAL DESIGN SPECIFICATION(s) FOR WOOD CONSTRUCTION, AF t PA, AND NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION, ANSI/TPI 1-15e5, AND THE LOCAL CODE JURISDICTIONS, 6, DO NOT OVERLOAD TRUSSES WITH BLDG MAT'LS, 1, CONNECTOR PLATES SHALL BE MANUFACTURED BY A WTCA MEMBER PLATE SUPPLIER AND SHALL MEET OR EXCEED ASTM A653/A653M REQUIREMENTS FOR STRUCTURAL STEEL. 70 I I ti) I GARAGE DOOR ATTATCHMENT 2 x 6 R 7. ((/COD BUCK 70 CONC, 1' HIGH DOOR: 4- 3/8"x5" HILTI KWIK BOLT II, (2 1/2" EMBED.) OR "RED -HEADS" SPACED EQUALLY 4 WITHIN 12" OF EA. END 8' HIGH DOOR: 5- 3/8" x 5" HILTI KWIK BOLT II, (2 1/2" EMBED.) OR "RED -HEADS" SPACED EQUALLY t WITHIN 12" OF EA, END TRACK BRACKETS TO P.T. BUCK 1' HIGH DOOR: 5 - 3/8" x 1 5/8" LAG SCREWS WITH WASHER HEADS, SPACED AS RS&D. BY MANUF. AT EA. SIDE. 8' HIGH DOOR: 6 - 3/8" x 1 5/8" LAG SCREWS WITH WASHER HEADS, SPACED AS RE&D. BY MANUF. AT EA. SIDE, SLIDING GLASS DOOR ATTACHMENT lx3 P.T. WOOD BUCK /N5T.41 1 A71ON 1/4" TAPCONS a 16" O.C. MAX, t WITHIN 6" OF CORNERS OR PER DOOR MANUF. ATTACH THRU FRAME AND BUCK INTO BLOCK W/ 1 1/4" MIN. PENETRATION INTO BLOCK WALL 2X4 P.T. WOOD BUCK 70 CONC, 1/4"x2 3/4" TAPCONS m 12" O.G. < WITHIN 6" OF CORNERS DOOR FRAME TO 2x P. T BUCK: SILL: 1 - 010 x 1 1/2" PH CP SMIS CENTERED AT 6" FROM JAMB. HEADERS: 8 - 1/4" x 1 1/2" LAG SCREWS CENTERED AT 6" FROM JAMB, JAMBS: 5 - 1/4" x 1 1/2" LAG SCREWS CENTERED AT 6" FROM HEAD AND SILL. SWING DOOR ATTACHMENT 2x4 P.T WOOD BUCK TO CONC HILTI PINS DS .111" DIA. WITH 1 1/4" PENETRATION AT 12" O.C. MAX. OR 1/4"x2 3/4" TAP -CON SCREWS AT 12" O.G. MAX. 6 WITHIN 6" OF CORNERS NOTE. DOOR BUCKS MUST BE WIDER THAN 774E DOOR .1AMBS PER R-6/3-6. 1�� /4111111e1 9099 NAILING SCHEDULE EDGE FIELD ITEM NAIL SIZE SPACING SPACING NOTES ZONE 1 ! 2 - All Joints In roof decking shall be (Bd round head 4" o.c. 6" o.c, covered w/ min. of 4" wide self- IS/32" CDX ring shank) adhering polymer modified bitumen ZONE 3 Roof sheathing tape applied directly (8d round head 4" c.c. 4" o.c, to the sheathing (secondary water barrier) ring shank) Roof sheathing Sd round head 4" o N/A Nall 2x fascia to truss ends w/ (2)to top of fascia ring shank .c. Ibd nails (min.) 15/32" CDX ad 4" o.c. 6" o.c. Wall sheathiflg 23/32" T<G loll4" o.c. 6" o.c. Glue all plywood Floor sheath) (PL400 arequal) Stud to 16d 3 per header ply 2 x 12 header Tap plate splice 16d 8 per splice Plate overlap minimum 24", over I stud 14 ga., 1.5" leg. 3/4" Install lath per ASTM C-1063-99, self - Wall metal lath crown staples b" O.C. along furring diamond lath, Overlap paper Framing member 1 1/2", overlap lath I" min. at edges Gelling i soffit 6d x 1/4" head 6" O.C. along Install lath per ASTM C-1063-99, metal lath roofing nalls. (1 3/4" Framing member High ribbed lath min.embed. I" min, overlap at edges S. I' "I EDGE O O O O w O O RIDGE 9O 41OO "00 m O n ROOF SHEATHING NAILING ZONES Filled Composfte Beam.., 1 1/2" clear Top two courses of 8" "H" block w/ I 05 bar In ea, filled solid 8" CMU all filled with 3000 psi concrete Number of courses vary with window ! wall elevations. See roof or floor framing plan(s) Precast lintel filled solid Composite Seam... 11/2" Top course of 8" "H" blocks over clear engineered precast lintels, Both with one 05 bar continuous and both Filled with 3000 p.s.i. concrete. Do not splice bars in either course over openings, Lintel Seam.,. 8"x8" precast conc. engineered precast lintel. with one •5 bar continuous filled with 3000 p.S.l, concrete. GENERAL FRAMING E ANCHORAGE NOTES: ALL MEMBERS ARE ANCHORED TO CONCRETE BEAM WITH SIMI-SON HETAL20 UNLESS NOTED OTHERWISE ON LAYOUT. TRUSS MANUFACTURER 18 TO FOLLOW THIS LAYOUT FOR PLACEMENT OF ALL TRUSSES AND GIRDERS, A SEPIA OF THIS LAYOUT 18 AVAILABLE FROM ARCHITECT FOR TRUSS MANUFACTURER'S USE. IF TRUSS MFGR CHANGES THIS LAYOUT WITHOUT WRITTEN PERMISSION FROM ARCHITECT THE TRUSS COMPANY BECOMES RESPONSIBLE FOR ALL ANCHORAGE DETAILS FROM BEARING TO FOOTER. m _W '4 0 0 CAST-CRETE LINTEL SCHEDULE SAFE SAFE LENGTH LOAD LENGTH LOAD LBS/ FT, LBS/ FT. 2' 10" 6113 12' O" 1254 3' 6" 6113 13, 4" I0l5 4' O" 6113 14' O" 1002 4' 6" 6113 14' 8" 13-10 5' 4" 5365 15' 4" 1250 5' loll 4360 1' 4" 950 6' 6" 3480 11 19' 4" l50 T' 6" 2661 21' 4" 598 9' 4" 1843 22' 0" 1 550 1& 6" 1533 24' o" 1 450 11' 4" 1366 8F16-I5 LINTELS: BOTH PRECAST LINTEL AND PERIMETER BEAM HAVE I s5 BAR CONTINUOUS, AND ARE FILLED WITH 3000 P51 CONCRETE. IF LINTEL FALLS BELOW 16" COMPOSITE BEAM, NO ADDITIONAL STEEL 15 REQUIRED - FILL ONLY, LINTEL 51ZE5: LINTELS USED SHALL BE 5"-1(" LARGER THAN THE OPENING BELOW WITH 4"-8" OF BEARING ON EACH SIDE OF THE OPENING. LAYOUT 4 FRAMING DATA ROOF SLOPE: 6/12 CEILING: 0/12 LOADING: 41 .s,f, I OVERHANGS: 24 ins. TAILS: Sq X Plumb U I HEEL HEIGHT: 18 Ins, DESIGN PA 0 CODE EDITION : F.B.C. 2020 (ITH1 EDITION) OCCUPANCY CATEGORY II EXPOSURE CATEGORY : C BASIC WIND PRESSURE : Se c e e ROOF DEAD LOAD : 15 pef CEILING DEAD LOAD 10 pof UNINHABITABLE ATTICS W/O STOR.: 10 pef UNINHABITABLE ATTICS W/ STOR.: (PER F.B.G, R301,5) 20 psf 134" BRG. HT, (9'10" T.O.F.) 91 SOT, a &W' MOT. @ 1' 4" FASTEN W/ 14-I0d. iRVALLEY FRAMING NOTE: VERTICAL MEMBERS MAY NOT NECESSARILY LINE UP WITH TOP CHORD OF SUPPORTING TRUSSES. IN 0 ■ W a REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTN BOCC DATE 08/21/20 DRAWN BY pJg me CHECED) MC REVISIONS 6/18/21 PER B.D. GENERAL NOTES: Contractor, subcontractors, material suppliers, etc, shall make themselves familiar with the contract documents and shall verify all dimensions, condltione at jobeite, plans, specifications, etc, as applicable and report any discrepancies, errors or omissions to the architect prior to any work being performed, otherwise we assume no responslbillty for any errors and the contractor, subcontractor, material supplier, etc. shall assume full responsiblllty for errors and/or delays and correct them at their own expence Changes, revisions, or alterations not made by this office In writing only, will fully, unconditionally and totally release the architect, Its employees, consultants and design professions, from any and all responelbillty. The architect has not been retained for the supervision or the administration of the execution of the work of this project. Each contractor shall be responsible for construction means, methods, techniques, sequences, and procedures for safety precautions and shall comply with the requirements of O.S.H.A. all applicable building codes and all governmental agencleshaving Jurisdiction. Each contractor shall make all arrangements for, obtain and pay for all permits, tests, inspections, and approvals required for his portion of the work. All work shall be guaranteed for a period of at least one year From the date of acceptance. Stucco shall be two coats approximataly 5/8" thick applied to masonry. 3/4" thick applied to metal lath. Lath shall be flat expanded diamond mesh galvanized, paper backed, weighing not lees than 3.4 pounds per sq. yard. Glass shall be float, tinted with shading coefficient of .71 catJI, 3/16" tempered for operable glass doors. Tempered giaes shall comply with ANSI-Z e1l Call glass at showers/tubs to be tempered). Caulking using Tremco or sq. eflicon-type products shall be applied at all junctions of wall and window and door frames with abutting wall surfaces to provide a weathertight water-resistant Installation. ELECTRICAL NOTES Electrical contractor shall comply with the N.E.C. and all applicable codes or authorities having jurisdiction. Electrical contractor to coordinate exact locations of all hvac equip. a it's loads w/ mach, contractor before roughing -In for proper power and wiring control layout and Installation. All outlets, switches and Itght fixture locations to be verified by owner on walk-thru with electrical contractor" Electrical contractor to sleeve drive and walkways as required For landscape lighting. Electrical contractor to provide power as required by pool contractor for all pool equipment. Electrical contractor to provide power as required by Irrigation contractor, Provide PVC sleeve to Inside surface of garage wall for phone termination. Service must enter Inside of garage for security" Provide outlet for eecurlty eyetem at owners option. All 110 V, 10, 15 and 20A. receptacles Installed outdoors and In bathrooms shall have ground fault circuit Interrupter. Unless otherwise noted, minimum size wire shall be 012 "AWG excluding control wiring" Smoke detectors to be powered by house electric service w/ battery back-up. Visible "Power on" Indicator and a test button. Verify all conductors and breakers w/ egiup, manuf. specs. All elect, switches shall be 48" a,f.f, unless otherwise noted. All receptacles shall be 12" a.f.f. unless otherwise noted" Closet lighting shall be min. 18" clear from adge of &helves. FLUM51NG NOTES It shall be the reeponelbillty of the plumbing contractor to produce an operational system in accordance with these drawings. The plumbing contractor shall guarantee the complete eyetem, parts and labor, for one year after first operation. Installation and materials shall be in accordance with the Standard Plumbing Code and all local codes. Plumbing contractor shall verify location, elevation, and size of existing mains before installation is started. Provide vacuum breakers on all hose bibbs and faucets with hose end connections. Fixtures shall be protected against water hammer with air chambers as required by code. Provide shutoff valves In the potable water supply and each piece of equipment. Insulate condensate lines. All hot and cold water lines shall be copper type I" for under- ground and type "M" for above ground installation w/ silver soldered joints. A/C NOTES It shall be the reeponetbllity of the A/C contractor to produce an operational system In accordance with these drawings. The A/C contractor shall furnish installation details and schematics OF all equipment to others who connect to the A/C equipment. t.a. Electrical and Plumbing contractor. Ductwork shall be I" thick fiberglass w/ taped joints unless noted otherwise. Provide condensate overflow pans under all units installed above calling. Provide adjustable, opposed blade dampers at all diffusers. Provide adjustable extractors or sputters at taps Into ducts or where ducts change directions. Airconditiontng supplier shall guarantee the complete eyetem, parts and labor, for one year after first operation. The compressor shall be guaranteed for an additional 4 years, parts only after first operation. Install filters at RAG's. Provide easy access to filters. Refer to energy calculations for A/C unit SEER requirements. NOTES: CONTRACTORS TO VERIFY ALL SQUARE FOOTAGES CONTRACTORS TO VERIFY ALL INTERIOR BEARING WALL FTG, W/ TRUSS MANUF. CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AVAILABLE AT SITE BEFORE PROCEEDING W/ CONSTRUCTION + CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR LAYOUT BUILDING ON LOT TO ASSURE NO SETBACKS OR EASEMENTS ARE ENCROACHED • REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING W/ WORK DUROCK SHALL BE USED IN ALL DAMP LOCATIONS 8 IN ALL SECOND FLOOR WALL AND FLOOR TILE AREAS • PROVIDE PLUMBING ACCESS PANELS TO ALL SLIP JOINT CONNECTIONS • TEMPERED GLASS TO BE USED AT ALL HAZARDOUS AREAS ALL BATH ROOM WALLS SHALL BE INSULATED • ALL LUMBER IN CONTACT W/CONCRETE OR MASONRY SHALL BE PRESSURE TREATED • ALL FRAMING (WALLS < ROOF) LUMBER TO HEMFIR Fb 1000 MIN. 12 I6 5/5" LT., . TEXT. STUCCO - 9_4" B.H_ REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC DATE : 08/21/20 DRAWN BY: pjg me COWED : MC REVISIONS : II'S_' B_H. (ENTRY) 94_ B_H _ _ _ _ _ O'O" FIN, FL. 12 --- --- 6 ,[\\,HGzaT ELEVATHON 14'vm--A 9(gvv 21 oil 5/S" LT. TEXT. STUCCO 'LT. STUCCO .TEXTURE LIHIFT-ELEVATHON Q 9 00 S/S'. SM. STUCCO ON IS" x IS" x S" BLK, COL. W/ 4"14. SM. STUCCO CAP t BASE. O'O"FIN. FL 11'S" B.N. (ENTRY) Ij7w_ 5'4" EA.. SMOOTH STUCCO FRIEZE O:O" FIN _FL. REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC DATE : 00/21/20 DBAWNBY : pl mane CHECIM : MC REVISIONS a ATTACH WINDOW TO BUCK THROUGH FIN (SCREWS PER MANUF. SPECS) COVER W/ STUCCO CAULK JOINTS CONT. BEAD OF DAP PREMIUM POLYURETHANE ADHESIVE SEALANT OR EQ. BEHIND FIN OR FLANGE t CONNECTION BETWEEN WIN. FRAME t STUCCO. ALUMINUM WINDOW i •o . 4•0 4•0 ° 4 4 5/6" STUCCO o D P D o FINISH - MATCH EXIST. ` II11114`�' COMPOSITE OR POURED CONCRETE TIE -BEAM - SEE PLANS ALIGN 2x6 P.T. BUCK W/ EDGE OF ELK. WALL < FINISH W/ 3/4" P.T. FUR STRIPS < 1/2" DRYWALL COAT ENTIRE BLK. OPN'G, W/ VULKEM 350 SEALANT FOR WINDOW FLASHING PER 2014 F,B.C.(5TH ED,) R103.8 (L4) SET 2x6 P.T. WD, BUCKS IN BED OF VULKEM 116 LIQUID FLASHING OR EQ. SEALANT. ANCHOR BUCKS TO CONC, BM., SILL 6 WALLS W/ 1/4'k3 1/4" TAPCONS (STAGGER) SPACE • 12" O.C. < W/1 3" OF CORNERS, (MIN. 1 1/4" EMBED.) COAT FACE AND RETURNS OF BUCKS W/ VULKEM 350 SEALANT OR EQ, ATTACH WINDOW THRU BUCK W/ 1/4" TAPCONS AT EVERY HOLE OR PER MANUF, W/ 1 1/4" MIN, PER 2014 F.B.C. (5TH ED,) R703.8 (1.4) INSTALL PER FMA/AAMA 200-12 WINDOW INSTALLATION SPEC. WOOD SILL W/ SKIRT TRIM _ VERIFY DESIGN W/ OWNER 6" MIN, POURED CONC. SILL W/ 1 "5 BAR W/ 8" HOOK BARS INTO FILLED CELLED WALL BEYOND (TYP. ALL WINDOWS) p 2000�9®00 I�6 ATTACH WINDOW TO BUCK THROUGH FIN (SCREWS ��- PER MANUF. SPECS) a �� COVER W/ STUCCO < DI CAULK JOINTS CONT. BEAD OF DAP PREMIUM POLYURETHANE ADHESIVE SEALANT OR EQ. BEHIND FIN OR FLANGE t CONNECTION BETWEEN WIN. FRAME 6 STUCCO, ALUMINUM WINDOW !\y���/y V V J.L�6 V J. 0 V V J AIZ B. 5" - (o" ICYNENE FILLED BLOCK CELL OR POURED CONC. COL. - SEE PLANS ALIGN 2x6 P.T. BUCK W/ Ile EDGE OF ELK. WALL FINISH W/ 3/4" P.T. FUR STRIPS t 1/2" DRYWALL 2x6 P.T. WOOD BUCK ANCHORED TO CONC. BEAM, SILL t WALLS W/ 1/4"x3 1/4" TAPCONS (STAGGER) SPACE • 12" O.G. < WITHIN 3" OF CORNERS. (MIN. 1 1/4" EMBED.) See typical note on wall section at left II on ceiling 2x4 non -load bearing — wall w/ studs at troll o,c, max. Nall drywall at "I" C.C. A edges E Field. 2x4 fire blocking mid -span (Per F.B.C. R302.11.1.2.) 1/2" drywall on interior walls. Engin, wd, trusses 5/8" Type "X" drywall on clg, '2x4 dbl, top plate nailed to truss w/ (2) IOd nails or blk'g, 6 24" o.c, w/ (2) lOd nails at loot. chord of trusses 1/2" type "X" drywall on garage interior walls. 2x4 p.t. sill plate w/ 1/4"x3 1/2" Tapcons or nails at 16" O.C. Thickened edge - See Foundation plan GARAGE WALL d iLidii.o DETAM d S11LiLd 3/4 99=1 9 0 99 This non -bearing type wall (NON -BEARING) assembly is per. F.B.C. R602,5, See typical note I / on wall section at left Imo/ Embedded Simpson anchor - see roof 8 fI. framing plan , {� S'4" $.H. A, 2'0" O.H. 5/8 STUCCO ON P.B. HIGH -Embedded Simpson 10'4" BOT. OF BM. ° „ RIB. MTL. LATH CLG. anchor - see roof „ E fl. framing plan " 2'0" O.H. CONC. COMPOSITE BEAM 8'0" B.H. ° ° SEE ROOF PLAN 5/8" Drywall on ceiling BEAM... STUCCO SOFFIT ON HIGH -RIB P.B. (COL. BEYOND) 2 courses 8" Hl-blk, with 2 "5 bars MTL. LATH continous.. Install Simpson straps at „ each truss, SEE FRAMING PLAN, " with seats. Concrete to be minimum „ 3000 psi. WALL... COLUMN.... ;; 8" CMU with 05 dowels from beam " „ 8 x 16"x 16 cone. block col. w/ (3) "5 vert. „ „ to footer in poured cells as shown „ „ " bare In filled cells from footer to top, Hook on foundation plan. Finish w/ 5/8" both ends of verticals. Stucco to match Stucco - See elevations. Interior: " „ elevations. " 3/4 p.t, furring stripe at 16 o,c. � „ „ on 3/4" lnaul. lod. and Finish with " 1/2" drywall. 1 1/2" BLOCK RECESS (TYP.) "1, FOUNDATION... 12" x 12" thk'd edge ;; FOUNDATION... ; w/ (1) 05 bar Cont. Slab to be 4" thick la"Cl x 16"w conc. mono. ftg. w/ 2 05 with fiber-mfx slab reinforcing ,;,, bare Cont. Slab to be 4 thick" over 6 mil vtsqueen vapor barrier on with fiber -mix slab reinforcin g ; ; potsened well compacted clean fill. ;} over ro mil vtsqueen vapor barrier on potsened well compacted clean fill, SLOPE DN.FIN. F ;;� • . • ;}' ; ' O'-5" FIN. FL. ;; v Q, ° 0,o a 4' a a a 0'-1 3/4" FIN. FL. I I Iy . , ■■■■■■■■MENNEN �■ ���■ Or■rrrr ■Orr■■■■■■■■■■■■■■■■■■ ■■■■Errrrr �I . L. I . NOON ■■■■■■■■■■ IM■■MMOOEr■■■■■rrrrrr■rrr■■E■r rrrrrrr■■■ EE■NEE■■M■ ■■■■■■■■ A�i■■■■■■■■■■■■■■■■■■■■■■ NOON■■rrrr ■r, r■■■■r ■■■■■■■■■■ rrrrrrrr EEEEEEEEEEEEEEEEEEEEEr rrrrrrrrrr ■■ rrrrrr rrrrrrrrrr rrrrrrrr �� ■■■■■■■■ .�iEEEEEE rrrrrrrrrr ooEEo' • '• • oroE o0000 MENNEEEEEEiiiGiiiiiiiiiEEEEEEEEEEEEEE . • • ' •. • • . • - " or000rl00000r000r0000 �0000�1���oo•ou•uu----- Embedded simpac anchor - see roof E fl, framing plan 5/8" STUCCO ON P.B. HIGH RIB, MTL. LATH CLG, 2X FRAMING ON COL, BEYOND TO CLG. 8"xl6" porch beam See roof plan - beam schedule COLUMN.... 5/8" Stucco on 16"xl6" conc. block column with 4 05 bars vertical from footer to top, Pressure treated full length stud against 8" x lio" column block, with precut stud adjacent. Attach both studs to poured column block with 1/2" x 7" Redheads, or equal, at 24" o.c.. Use Palm Beach County 3" x 3" x 1/4" steel washers at each bolt. 5" - 6" ICYNENE INSUL, Embedded simpson anchor - see roof E fl. Framing plan 5/8" Drywall on ceiling BEAM.,. 2 courses 8" Hl-blk. with 2 05 bars continous.. Install Simpson straps at " each truss, SEE FRAMING PLAN, with seats. Concrete to be minimum „ 3000 psi. „ „ „ „ WALL... 8" CMU with 05 dowels from beam „ to footer 1n poured cells as shown on foundation plan. Finish w/ 5/8" stucco - See elevations. Interior: 3/4" p.t, furring strips at 16" o,c, on 3/4" insul, bd, and finish with III1/2" drywall. .. .. n ancle of Stucco to match elevations, I®I I�I BLOCK -- FOUNDATION... cont.12" x 12" thk'cl edge FOUNDATION... 6 , 3ro" x 36" x 12" conc. bare cont. Slab to be 4" thick ped IL flber-mix slab reinforcing O.C. bare beyond _polsened well Compacted clean fill. SLOPE . ■■■■■■■■■■ ■'" NOON ■■■■■■■■■■ EEEE■I■■ErEErEEEE■■■■■M■■MMMMMMM ■EEEEEEEE M■, NOON ■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ M■rj� •/,' / • / • rrrrrr prrrrr■O EErEEEEEEEEEEEErrrrrrrrrrrrrrrrrrr NEEE rrrrrr EEEEEEEEEE 0000000E■EEEEEEEE■EEErrrrONO, o0000000000000000m o�roo■ EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEMEN O�EEEEE■ EEEEEEEEEEEEEEEEEEEEEErEEEEEEEEENow ■rrrrrrE�j ■Orr EEEEEEEEEErrrrrrrrrrrrrrEEEEEEEEOrr EEEEEEEEEEEEEEEEEEEEEEEIN MEN MEN ErEEEEEEEEEEEEEEEE FFes W (Hold frame wall 1/2" inside column blocks so that 1/2" cdx sheathing butts to block. SECTION VIEW Provide 2 "5 bare hooked from Footer to tie beam. If "U" block type beam Is used hook one "5 into each course, outer bar to top course, inner bar to bottom course. ROOFING... Asphalt shingles on 300 Felt paper tin tagged to 5/8" cdx roof sheathing on engineered wood roof truselss at 24"o.c, Attach roof sheathing to 2x fascia w/ Sd ring shank nails s 4" o.c. < 2x fascia to truss ends w/ (2) 166 nails. 12 EAVE.., e I x 3, 2 x 8 Smooth cedar fascia w/ cont, gale, drip edge w/ stucco on p.b. high rib metal lath soffits. 9'4" B.H. STUCCO SOFFIT ON HIGH -RIB P.B. MTL. LATH 1 1/2" BLOCK RECESS (TYP.) 0'0" FIN. FL. 5" - ro" ICYNENE INSUL. i 5/8" Drywall on ceiling BEAM,,, 2 courses 8" H-blk. with 2 05 bare continous„ Install Simpson straps „ at each truss, SEE FRAMING PLAN, with seats, Concrete to be minimum 3000 psi, WALL,., 8" CMU with 05 dowels from beam • to footer in poured cells as shown on foundation plan. Finish w/ 5/6" stucco - See elevations, Interior: 3/4" p.t. furring strips at 16" o.c. " on 3/4" insul, bd, and finish with 1/2" drywall, ®I I�I I�I FOUNDATION... bars contInous. Slab to be 4" thick with I �Li(• Iover ICII ..:- - -compactedclean NONE rrrrrrr■■r■■■■■■■■rr NONE ■EMMEEEEEEEEEEEEEEEE rrrr EEEEEEEEEEEEEEEEEErMEMMEMEMEMEMEMEMEMM NONE MOMMEMOMMEMMEMEMEME EEEEEE EEEEE�r*r����rr*■err IN r0111 ru EEu!:_ PVJ..:� r,n =Ind • ' 141 W N 41) t� a DATE : 08/21/20 DRAWNBY : FJg me CHECKED : MC REVISIONS : E COMPLIANCE LUCIE COUNTY BOCCp QV o o ®I I�I I�I FOUNDATION... bars contInous. Slab to be 4" thick with I �Li(• Iover ICII ..:- - -compactedclean NONE rrrrrrr■■r■■■■■■■■rr NONE ■EMMEEEEEEEEEEEEEEEE rrrr EEEEEEEEEEEEEEEEEErMEMMEMEMEMEMEMEMEMM NONE MOMMEMOMMEMMEMEMEME EEEEEE EEEEE�r*r����rr*■err IN r0111 ru EEu!:_ PVJ..:� r,n =Ind • ' 141 W N 41) t� a DATE : 08/21/20 DRAWNBY : FJg me CHECKED : MC REVISIONS : E COMPLIANCE LUCIE COUNTY BOCCp QV o o (2) 2/0 CU THHN/THWN 6 lU •I in 2" c — Meter Can (2) 250 MGM < lU 310 IN 2 1/2" C OR AS PER FPL Under rounc from FP04 Grade QW 2020 NEC; 21OJ2 (A) Arc -Fault Clrcuft-/Interrupter Protectlon. 200A Dwellln nI ;- 1 T4 olt, sin a and 20-ampere Dieconnecte as required branch circuits supplying outlets Installed or devices In dwelling panel unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, sun rooms, recreation rooms, closets, hallways, laundy areas or similar rooms or areas shall be protected by any of the means described In the NEC 2020 210,12 (A)(1) through (6) To House Service 2020 NEC 406.12 Tamper -resistant receptacles In are required In dwelling units In all areas as specTfied In 2020 NEC 406.12(A) through (C). All 125-volt, 15- and 20-ampere receptacles. TO APPROVED GROUND (SEE NOTE BELOW) ELECTRICAL RISER no Scales 2011 NEC 250.52 Grounding Electrodes, Concrete -Encased Electrode. An electrode encased by at least 2 In. of concrete, located horizontally near the bottom or vertically, and within that portion of a concrete foundation or footing that Is In direct contact with the earth, consisting of at least 20 ft. of one or more bare or zinc galvanized or other electrically conductive coated steel rainforcing bare or rode of not lees than K in. In diameter. Reinforcing bars shall be permitted to be bonded together by the usual steel tle wires or other effective means. Where multiple concrete-ancased electrodes are present at a building or structure, it shall be permissible to bond only one Into the grounding electrode system. A.1r 1 . [ Ai_= AM / I /1Ar) 0,r'Li=MI11 ;= CI G. DESCRIPTION PO SRKR WIRE LOAD 100% 1 REFRIGERATOR 1 20 12 1.5 NO 3-5 ACCU 01 2 40 10 N/C T-9 AHU -1 2 60 6 10.0 YES I1-13 15-IT 19 SMALL APPLIANCE 1 20 12 1.5 NO 21 SMALL APPLIANCE 1 20 12 1.5 NO 23 SMALL APPLIANCE 1 20 12 1.5 NO 23 GEN, LIGHTING / FANS I 15 14 NO 25 27 29 2 4 b 2114 S.F. x 3 WATTS 0 10 DRYER 2 50 8 8.0 NO 12-14 DISHWASHER / DISP. 2 20 12 2.5 NO 16-I8 OVEN/RANGE 2 50 5 8.0 NO 20 WATER HEATER I 20 72 1.5 NO 22 SPRINKLER PUMP 1 20 112 1.5 NO 24 26 28 30 TOTAL KW LESS 100% LOAD KW 43.3 AIR HANDLER ® 100% 10,000 PANEL / 200 AMP, FIRST 10 KW • 100% 10,000 REMAINDER a 40% 11,320 TOTAL 31,320 + 240 PROVIDE 155.5 AMPS 2" SINK W/ DISP. + Dl (AUTO VEI 2" TUB G Florida Budding Code Ith Edition (2020) Energy Conservation C402.5.6 Recessed lighting. Recessed luminalres Installed In the building thermal envelope shall be all of the follawing: LIC-rated. 2.1-abeled as having an air leakage rate of not more 2.0 cfm (0.944 L/s) when tested In accordance with ASTM E203 at a 1,51 pef (15 Pa) pressure differential. 3.6ealed with a gasket or caulk between the housing and Interior wall or telling covering. (See Section C402.5.13 applicable Bullding cavities) C402.5.9.1 Vented dropped ceiling cavities. C402.5.e,2 Unvented dropped calling cavities. C402.5,'B 3 Separate tenancies. C402.5.9.4 Air distributlon system components. ELECTRICAL LEGEND ELECTRICAL SYMBOL Attic Light ` (abvl Can Light Gen Light VP P Disconnect 1^c Exhaust Fan rEm 99 Exhaust Fan w- Light Flood Light I0a Garage Door Opener w- GFI GFI Opener Light J-Box VLOJ J-BOX v.L.O.J. PB push button PB cable tv outlet fluorescent light I x 4 light outlet outlet 220V outlet gfl outlet split outlet wp-gfI WP/GFI ,FI, smoke afcl cc dot AFCI �CC DET. smoke detector AFCI AFCI ewitCh $ switch 3 was $3 wall light exterior 4 2" VTR 1 1 i 1 1 , i ' SHWR. PLUMDDIHN" RHSER D(siHAAMn VENT TO REAR OF STRUCTURE CONTRACTOR TO VERIFY ALL PIPE SIZES -PER CODE AC � r lu ♦ � � I I I I 'I J-BOX I I OAFCO I, 1, iq� AFCI ,1 sCO DET. AFC \ 1---------------�--'-----------"-' 1 GAS LIN ,\�P FOR FU E U J-BOX 1 ' ♦ ♦ 1 ♦ I ' sAFG ri FOI , ` , 1 ♦I 1 . ` CO PET. ' TV , 1 M 1 1 1 1 , 1 AFCI / � 1 L. AOX 1 ' -To Garage Lights rm � z I14r'wid-I Flood L i� pull call at JJ \ _ D W HU I I I I -- ---""- ----- -L.L_ al W.H. :: ---------- To Garage Lights-' 1 rm e � �14�wide�� I > pull down .{ stair _ J, z a GFI O Opener ____________________ i I I ' �To Switch e Entry ' a Garage I � Z! RDHCAL PLAN TELECT aD4° 9(0 °° REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC DATE : 05/21/20 DRAWN BY : I me CHECKED : MC REVISIONS :