Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hargrave Residence Builder Name: Street: Lot 1 Permit Office: St. Lucie County City, State, Zip: Port St. Lucie , FL, 34952 Permit Number: Owner: Hargrave Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$2344.8 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2111.50 ft2 b. Frame - Wood, Adjacent R=11.0 233.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2226.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2226.00 ft2 6. Conditioned floor area above grade (ft2) 2226 b. N/A R= ftZ Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(350.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 95 a. U-Factor: Sgl, U=0.65 198.67 ft2 SHGC: SHGC=0.30 b. U-Factor: Sgl, U=0.65 151.61 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 40.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 6.142 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.278 a. Electric Strip Heat 34.0 COP:1.00 Area N/A ft2 15. Hot water systems N/A a. Electric Cap: 50 gallons 9. Floor Types (2226.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2226.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.157 Total Proposed Modified Loads: 72.23 PASS Total Baseline Loads: 73.11 1 hereby certify that the plans and specifications covered by Review of the plans and S'KE ST,q?, this calculation are in compliance with the Florida Energy specifications covered by this ,y0-� Code. calculation indicates compliance y rp, ,.�,,,.�� a!• �O with the Florida Energy Code. �,'��, a+uFs�'•'• -:: ••• "�,� PREPARED BY:Q&0 Before construction is completed DATE: 3-25-2 this building will be inspected for compliance with Section 553.908� m I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. CDD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: r}- t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). I:, C'WQ,-PV3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software ''--�°� �VPage 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title:. Hargrave Residence Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2226 Lot # Owner Name: Hargrave Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Lot 1 Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Port St. Lucie , Family Type: Detached FL, 34952 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2226 21385.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 4 236 2218.4 No 1 1 1 Yes Yes Yes 2 Hall 24 225.6 No 0 1 Yes Yes Yes 3 Bedroom 2 150 1410 No 1 1 1 Yes Yes Yes 4 Bath 2 64 601.6 No 0 1 Yes Yes Yes 5 Bedroom 3 144 1353.6 No 1 1 1 Yes Yes Yes 6 Laundry 76 714.4 No 1 1 Yes Yes Yes 7 Kitchen 182 1710.8 Yes 2 1 No Yes Yes 8 Pantry 25 235 No 0 1 No Yes Yes 9 Hall 53 498.2 No 0 1 No Yes Yes 10 Dining 130 1222 No 1 1 Yes Yes Yes 11 Foyer 48 451.2 No 0 1 Yes Yes Yes 12 Toilet 30 282 No 0 1 Yes Yes Yes 13 Master Bath - 151 1419.4 No 0 1 Yes Yes Yes 14 WIC 2 42 394.8 No 0 1 Yes Yes Yes 15 Master Bedroom 285 2679 No 2 1 1 Yes Yes Yes 16 WIC 1 42 394.8 No 0 1 No Yes Yes 17 Great Room 461 4794.4 No 2 1 Yes Yes Yes 18 Hall 83 780.2 No 0 1 Yes Yes Yes 3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 4 40 ft 236 ft2 — 1 0 0 2 Slab -On -Grade Edge Insulatio Hall 3 6 ft 24 ft2 — 1 0 0 3Slab-0n-Grade Edge Insulatio Bedroom 2 11 ft 150 ft2 — 1 0 0 4SIab-On-Grade Edge Insulatio Bath 2 8 It 64 ft2 — 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 3 11 ft 144 ft2 — 1 0 0 6 Slab -On -Grade Edge Insulatio Laundry 22 ft 76 ft2. — 1 0 0 7 Slab -On -Grade Edge Insulatio Kitchen 1 It 182 ft2 — 1 0 0 8 Slab -On -Grade Edge Insulatio Pantry 1 It 25 ft2 — 1 0 0 9 Slab -On -Grade Edge Insulatio Hall 2 1 It 53 ft2 _ 1 0 0 10SIab-On-Grade Edge Insulatio Dining 19 ft 130 ft2 — 1 0 0 11SIab-On-Grade Edge Insulatio Foyer 8 It 48 ft2 — 1 0 0 12SIab-On-Grade Edge Insulatio Toilet 9 ft 30 ft2 — 1 0 0 13SIab-On-Grade Edge Insulatio Master Bath 22 ft 151 ft2 — 1 0 0 14SIab-On-Grade Edge Insulatio WIC 2 7 ft 42 ft2 — 1 0 0 15SIab-On-Grade Edge Insulatio Master Bedroom 33 ft 285 ft2 — 1 0 0 16SIab-On-Grade Edge Insulatio WIC 1 1 ft 42 ft2 — 1 0 0 17SIab-On-Grade Edge Insulatio Great Room 21 ft 461 ft2 — 1 0 0 18SIab-On-Grade Edge Insulatio Hall 1 5 ft 83 ft2 — 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2490 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2226 ft2 N N 3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Bedroom 4 0 Blown 236 ft2 0.1 Wood 2 Under Attic (Unvented) Hall 3 0 Blown 24 ft2 0.1 Wood 3 Under Attic (Unvented) Bedroom 2 0 Blown 150 ft2 0.1 Wood 4 Under Attic (Unvented) Bath 2 0 Blown 64 ft2 0.1 Wood 5 Under Attic (Unvented) Bedroom 3 0 Blown 144 ft2 0.1 Wood 6 Under Attic (Unvented) Laundry 0 Blown 76 ft2 0.1 Wood 7 Under Attic (Unvented) Kitchen 0 Blown 182ft2 0.1 Wood 8 Under Attic (Unvented) Pantry 0 Blown 25 ft2 0.1 Wood 9 Under Attic (Unvented) Hall 2 0 Blown 53 ft2 0.1 Wood 10 Under Attic (Unvented) Dining 0 Blown 130 ft2 0.1 Wood 11 Under Attic (Unvented) Foyer 0 Blown 48 ft2 0.1 Wood 12 Under Attic (Unvented) Toilet 0 Blown 30 ft2 0.1 Wood 13 Under Attic (Unvented) Master Bath 0 Blown 151 ft2 0.1 Wood 14 Under Attic (Unvented) WIC 2 0 Blown 42 ft2 0.1 Wood 15 Under Attic (Unvented) Master Bedroom 0 Blown 285 ft2 0.1 Wood 16 Under Attic (Unvented) WIC 1 0 Blown 42 ft2 0.1 Wood 17 Under Attic (Unvented) Great Room 0 Blown 461 ft2 0.1 Wood 18 Under Attic (Unvented) Hall 1 0 Blown 83 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing .Framing Solar Below 1 N Exterior Concrete Block - Int InsuBedroom 4 4.1 20 0 9 5 188.3 ft2 0 0 0.3 0 2 E Exterior Concrete Block- Int InsuBedroom 4 4.1 7 0 9 5 65.9 ft2 0 0 0.3 0 3 W Exterior Concrete Block - Int InsuBedroom 4 4.1 13 0 9 5 122.4 ft2 0 0 0.3 0 4 E Exterior Concrete Block - Int Insul Hall 3 4.1 6 0 9 5 56.5 ft2 0 0 0.3 0 5 W Exterior Concrete Block - Int InsuBedroom 2 4.1 11 0 9 5 103.6 ft2 0 0 0.3 0 6 W Exterior Concrete Block - Int Insul Bath 2 4.1 8 0 9 5 75.3 ft2 0 0 0.3 0 7 W Exterior Concrete Block - Int InsuBedroom 3 4.1 11 0 9 5 103.6 ft2 0 0 0.3 0 _ 8 E Exterior Concrete Block - Int Insul Laundry 4.1 2 0 9 5 18.8 ft2 0 0 0.3 0 _ 9 S Exterior Concrete Block - Int Insul Laundry 4.1 14 0 9 5 131.8 ft2 0 0 0.3 0 _ 10 W Exterior Concrete Block - Int Insul Laundry 4.1 6 0 9 5 56.5 ft2 0 0 0.3 0 _ 11 E Exterior Concrete Block - Int Insul Dining 4.1 4 0 9 5 37.7 ft2 0 0 0.3 0 _ 12 S Exterior Concrete Block - Int Insul Dining 4.1 13 0 9 5 122.4 ft2 0 0 0.3 0 _ 13 W Exterior Concrete Block - Int Insul Dining 4.1 2 0 9 5 18.8 ft2 0 0 0.3 0 14 S Exterior Concrete Block - Int Insul Foyer 4.1 8 0 9 5 75.3 ft2 0 0 0.3 0 15 S Exterior Concrete Block- Int Insul Toilet 4.1 5 0 9 5 47.1 ft2 0 0 0.3 0 16 W Exterior Concrete Block - Int Insul Toilet 4.1 4 0 9 5 37.7 ft2 0 0 0.3 0 17 E Exterior Concrete Block - Int InstMaster Bath 4.1 11 0 9 5 103.6 ft2 0 0 0.3 0 _ 18 S Exterior Concrete Block - Int InsdlAaster Bath 4.1 11 0 9 5 103.6 ft2 0 0 0.3 0 _ 19 E Exterior Concrete Block - Int Insul WIC 2 4.1 7 0 9 5 65.9 ft2 0 0 0.3 0 20 N Exterior Concrete Block - Int InsMaster Bedro 4.1 15 0 9 5 141.3 ft2 0 0 0.3 0 _21 E Exterior Concrete Block- Int InsMaster Bedro 4.1 18 0 9 5 169.5 ft2 0 0 0.3 0 _22 N Exterior Concrete Block - Int Insu(Sreat Room 4.1 21 0 10 5 218.8 ft2 0 0 0.3 0 3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Space Cavity Width Height Sheathing Framing Solar Belo w SzAdjacent # ()Mt 10 JAIR11 Type_'lie Et In Et In Area R-11alue Fraction Ahqnr Grade% 23 S Exterior Concrete Block - Int Insul Hall 1 4.1 5 0 9 5 47.1 ft2 0 0 0.3 0 _24 N Garage Frame - Wood Laundry 11 10 9 4 93.3 ft2 0.23 0.3 0 25 W Garage Frame - Wood Laundry 11 2 9 4 18.7 ft2 0.23 0.3 0 _26 N Garage Frame - Wood Laundry 11 4 9 4 37.3 ft2 0.23 0.3 0 _27 N Garage Frame - Wood Hall 1 11 5 9 4 46.7 ft2 0.23 0.3 0 28 E Garage Frame - Wood Dining 11 2 9 4 18.7 ft2 0.23 0.3 0 _29 N Garage Frame -Wood Dining 11 2 9 4 18.7 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Hall 1 None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered Proposed orientation. Wall Overhang V/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 E 4 Metal Low-E Single Yes 0.65 0.3 N 22.7 ft2 8 ft 0 in 1 ft 4 in None None 3 W 5 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 4 W 6 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 5 W 7 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 10 Metal Low-E Single Yes 0.65 0.25 N 6.3 ft2 2 ft 0 in 1 ft 4 in None None 7 S 12 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 In 1 ft 4 in None None 8 S 14 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 7 ft 0 in 1 ft 4 in None None 9 S 14 Metal Low-E Single Yes 0.65 0.25 N 10.2 ft2 7 ft 0 in 1 ft 4 in None None 10 S 18 Metal Low-E Single Yes 0.65 0.25 N 22.1 ft2 2 ft 0 in 1 ft 4 in None None 11 N 20 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 12 N 22 Metal Low-E Single Yes 0.65 0.3 N 128.0 ft2 10 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 25 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 1782.1 97.77 183.56 .0971 5 3/25/2021 9:42 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 40 kBtu/hr 1200 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — — Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 95 ft2 Attic 45 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating f X; Jan Feb ki Mar Apr Apr May May rl Jun 41 Jul Aug JXJ� jXjSep Oct H Nov Oct Nov H Dec Dec Venting [ ]Jan Feb X Mar Jun [ Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 lbs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry 3/25/2021 9:42 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft.. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 lbs/sq.ft. , ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet De%ult(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Defauit(8 Ibs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/s .ft. ft2 ft 0.3 Hall 1 3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Detached or multiple -family 2. Detached b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 40.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2226 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.278 14. Heating system: Capacity 34.0 c) Area 7c. 350.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery, unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be comp�tad-lb4ed on installed code compliant features. Builder Date: Address R New Home: t Lot 1 City/FL Zip: Port St. Lucie, FL 34952 3/24/2021 5:50:12 PM EnergyGauge® USA 7.0.00 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hargrave Residence Builder Name: Street: Lot 1 Permit Office: St. Lucie County City, State, Zip: Port St. Lucie, FL , 34952 Permit Number: Y U Owner: Hargrave Residence Jurisdiction: St. Lucie County w x Design Location: FL, Fort Pierce o COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinki cover plates walls or cellingr. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/24/2021 6:41 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1