HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Hargrave Residence
Builder Name:
Street: Lot 1
Permit Office: St. Lucie County
City, State, Zip: Port St. Lucie , FL, 34952
Permit Number:
Owner: Hargrave Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$2344.8 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2111.50 ft2
b. Frame - Wood, Adjacent
R=11.0 233.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2226.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2226.00 ft2
6. Conditioned floor area above grade (ft2) 2226
b. N/A
R= ftZ
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(350.3 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 95
a. U-Factor: Sgl, U=0.65 198.67 ft2
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=0.65 151.61 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
40.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 6.142 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.278
a. Electric Strip Heat
34.0 COP:1.00
Area
N/A ft2
15. Hot water systems
N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2226.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2226.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF, Pstat
Glass/Floor Area: 0.157 Total Proposed Modified Loads: 72.23
PASS
Total Baseline Loads: 73.11
1 hereby certify that the plans and specifications covered by
Review of the plans and
S'KE ST,q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
,y0-�
Code.
calculation indicates compliance
y rp, ,.�,,,.�� a!•
�O
with the Florida Energy Code.
�,'��,
a+uFs�'•'• -:: ••• "�,�
PREPARED BY:Q&0
Before construction is completed
DATE: 3-25-2
this building will be inspected for
compliance with Section 553.908�
m
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
CDD WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: r}- t
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
I:, C'WQ,-PV3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software ''--�°� �VPage 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:.
Hargrave Residence
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2226
Lot #
Owner Name:
Hargrave Residence
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
Lot 1
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Port St. Lucie ,
Family Type:
Detached
FL, 34952
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2226
21385.4
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
Bedroom 4
236
2218.4 No
1
1
1
Yes
Yes
Yes
2
Hall
24
225.6 No
0
1
Yes
Yes
Yes
3
Bedroom 2
150
1410 No
1
1
1
Yes
Yes
Yes
4
Bath 2
64
601.6 No
0
1
Yes
Yes
Yes
5
Bedroom 3
144
1353.6 No
1
1
1
Yes
Yes
Yes
6
Laundry
76
714.4 No
1
1
Yes
Yes
Yes
7
Kitchen
182
1710.8 Yes
2
1
No
Yes
Yes
8
Pantry
25
235 No
0
1
No
Yes
Yes
9
Hall
53
498.2 No
0
1
No
Yes
Yes
10
Dining
130
1222 No
1
1
Yes
Yes
Yes
11
Foyer
48
451.2 No
0
1
Yes
Yes
Yes
12
Toilet
30
282 No
0
1
Yes
Yes
Yes
13
Master Bath -
151
1419.4 No
0
1
Yes
Yes
Yes
14
WIC 2
42
394.8 No
0
1
Yes
Yes
Yes
15
Master Bedroom
285
2679 No
2
1
1
Yes
Yes
Yes
16
WIC 1
42
394.8 No
0
1
No
Yes
Yes
17
Great Room
461
4794.4 No
2
1
Yes
Yes
Yes
18
Hall
83
780.2 No
0
1
Yes
Yes
Yes
3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Bedroom 4
40 ft
236 ft2
—
1
0
0
2 Slab -On -Grade Edge Insulatio
Hall 3
6 ft
24 ft2
—
1
0
0
3Slab-0n-Grade Edge Insulatio
Bedroom 2
11 ft
150 ft2
—
1
0
0
4SIab-On-Grade Edge Insulatio
Bath 2
8 It
64 ft2
—
1
0
0
5 Slab -On -Grade Edge Insulatio
Bedroom 3
11 ft
144 ft2
—
1
0
0
6 Slab -On -Grade Edge Insulatio
Laundry
22 ft
76 ft2.
—
1
0
0
7 Slab -On -Grade Edge Insulatio
Kitchen
1 It
182 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulatio
Pantry
1 It
25 ft2
—
1
0
0
9 Slab -On -Grade Edge Insulatio
Hall 2
1 It
53 ft2
_
1
0
0
10SIab-On-Grade Edge Insulatio
Dining
19 ft
130 ft2
—
1
0
0
11SIab-On-Grade Edge Insulatio
Foyer
8 It
48 ft2
—
1
0
0
12SIab-On-Grade Edge Insulatio
Toilet
9 ft
30 ft2
—
1
0
0
13SIab-On-Grade Edge Insulatio
Master Bath
22 ft
151 ft2
—
1
0
0
14SIab-On-Grade Edge Insulatio
WIC 2
7 ft
42 ft2
—
1
0
0
15SIab-On-Grade Edge Insulatio
Master Bedroom 33 ft
285 ft2
—
1
0
0
16SIab-On-Grade Edge Insulatio
WIC 1
1 ft
42 ft2
—
1
0
0
17SIab-On-Grade Edge Insulatio
Great Room
21 ft
461 ft2
—
1
0
0
18SIab-On-Grade Edge Insulatio
Hall 1
5 ft
83 ft2
—
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2490 ft2
0 ft2 Light
N
0.6 No 0.9
No
20
26.6
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2226 ft2
N N
3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Bedroom 4
0
Blown
236 ft2
0.1
Wood
2
Under Attic (Unvented) Hall 3
0
Blown
24 ft2
0.1
Wood
3
Under Attic (Unvented) Bedroom 2
0
Blown
150 ft2
0.1
Wood
4
Under Attic (Unvented) Bath 2
0
Blown
64 ft2
0.1
Wood
5
Under Attic (Unvented) Bedroom 3
0
Blown
144 ft2
0.1
Wood
6
Under Attic (Unvented) Laundry
0
Blown
76 ft2
0.1
Wood
7
Under Attic (Unvented) Kitchen
0
Blown
182ft2
0.1
Wood
8
Under Attic (Unvented) Pantry
0
Blown
25 ft2
0.1
Wood
9
Under Attic (Unvented) Hall 2
0
Blown
53 ft2
0.1
Wood
10
Under Attic (Unvented) Dining
0
Blown
130 ft2
0.1
Wood
11
Under Attic (Unvented) Foyer
0
Blown
48 ft2
0.1
Wood
12
Under Attic (Unvented) Toilet
0
Blown
30 ft2
0.1
Wood
13
Under Attic (Unvented) Master Bath
0
Blown
151 ft2
0.1
Wood
14
Under Attic (Unvented) WIC 2
0
Blown
42 ft2
0.1
Wood
15
Under Attic (Unvented) Master Bedroom
0
Blown
285 ft2
0.1
Wood
16
Under Attic (Unvented) WIC 1
0
Blown
42 ft2
0.1
Wood
17
Under Attic (Unvented) Great Room
0
Blown
461 ft2
0.1
Wood
18
Under Attic (Unvented) Hall 1
0
Blown
83 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing .Framing Solar
Below
1
N
Exterior Concrete Block - Int InsuBedroom 4
4.1
20
0 9
5
188.3 ft2
0
0
0.3
0
2
E
Exterior Concrete Block- Int InsuBedroom 4
4.1
7
0 9
5
65.9 ft2
0
0
0.3
0
3
W
Exterior Concrete Block - Int InsuBedroom 4
4.1
13
0 9
5
122.4 ft2
0
0
0.3
0
4
E
Exterior Concrete Block - Int Insul Hall 3
4.1
6
0 9
5
56.5 ft2
0
0
0.3
0
5
W
Exterior Concrete Block - Int InsuBedroom 2
4.1
11
0 9
5
103.6 ft2
0
0
0.3
0
6
W
Exterior Concrete Block - Int Insul Bath 2
4.1
8
0 9
5
75.3 ft2
0
0
0.3
0
7
W
Exterior Concrete Block - Int InsuBedroom 3
4.1
11
0 9
5
103.6 ft2
0
0
0.3
0
_ 8
E
Exterior Concrete Block - Int Insul Laundry
4.1
2
0 9
5
18.8 ft2
0
0
0.3
0
_ 9
S
Exterior Concrete Block - Int Insul Laundry
4.1
14
0 9
5
131.8 ft2
0
0
0.3
0
_ 10
W
Exterior Concrete Block - Int Insul Laundry
4.1
6
0 9
5
56.5 ft2
0
0
0.3
0
_ 11
E
Exterior Concrete Block - Int Insul Dining
4.1
4
0 9
5
37.7 ft2
0
0
0.3
0
_ 12
S
Exterior Concrete Block - Int Insul Dining
4.1
13
0 9
5
122.4 ft2
0
0
0.3
0
_ 13
W
Exterior Concrete Block - Int Insul Dining
4.1
2
0 9
5
18.8 ft2
0
0
0.3
0
14
S
Exterior Concrete Block - Int Insul Foyer
4.1
8
0 9
5
75.3 ft2
0
0
0.3
0
15
S
Exterior Concrete Block- Int Insul Toilet
4.1
5
0 9
5
47.1 ft2
0
0
0.3
0
16
W
Exterior Concrete Block - Int Insul Toilet
4.1
4
0 9
5
37.7 ft2
0
0
0.3
0
17
E
Exterior Concrete Block - Int InstMaster Bath
4.1
11
0 9
5
103.6 ft2
0
0
0.3
0
_ 18
S
Exterior Concrete Block - Int InsdlAaster Bath
4.1
11
0 9
5
103.6 ft2
0
0
0.3
0
_ 19
E
Exterior Concrete Block - Int Insul WIC 2
4.1
7
0 9
5
65.9 ft2
0
0
0.3
0
20
N
Exterior Concrete Block - Int InsMaster Bedro
4.1
15
0 9
5
141.3 ft2
0
0
0.3
0
_21
E
Exterior Concrete Block- Int InsMaster Bedro
4.1
18
0 9
5
169.5 ft2
0
0
0.3
0
_22
N
Exterior Concrete Block - Int Insu(Sreat Room
4.1
21
0 10
5
218.8 ft2
0
0
0.3
0
3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Space
Cavity Width
Height
Sheathing Framing
Solar
Belo w
SzAdjacent
#
()Mt
10
JAIR11 Type_'lie
Et In
Et In
Area
R-11alue
Fraction Ahqnr
Grade%
23
S
Exterior
Concrete Block - Int Insul Hall 1
4.1 5
0
9 5
47.1 ft2
0
0
0.3
0
_24
N
Garage
Frame - Wood
Laundry
11 10
9 4
93.3 ft2
0.23
0.3
0
25
W
Garage
Frame - Wood
Laundry
11 2
9 4
18.7 ft2
0.23
0.3
0
_26
N
Garage
Frame - Wood
Laundry
11 4
9 4
37.3 ft2
0.23
0.3
0
_27
N
Garage
Frame - Wood
Hall 1
11 5
9 4
46.7 ft2
0.23
0.3
0
28
E
Garage
Frame - Wood
Dining
11 2
9 4
18.7 ft2
0.23
0.3
0
_29
N
Garage
Frame -Wood
Dining
11 2
9 4
18.7 ft2
0.23
0.3
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Wood
Hall 1
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered Proposed orientation.
Wall
Overhang
V/
#
Omt ID
Frame Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Metal Low-E Single
Yes
0.65 0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
E
4
Metal Low-E Single
Yes
0.65 0.3
N
22.7 ft2
8 ft 0 in
1 ft 4 in
None
None
3
W
5
Metal Low-E Single
Yes
0.65 0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
W
6
Metal Low-E Single
Yes
0.65 0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
W
7
Metal Low-E Single
Yes
0.65 0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
W
10
Metal Low-E Single
Yes
0.65 0.25
N
6.3 ft2
2 ft 0 in
1 ft 4 in
None
None
7
S
12
Metal Low-E Single
Yes
0.65 0.25
N
30.0 ft2
2 ft 0 In
1 ft 4 in
None
None
8
S
14
Metal Low-E Single
Yes
0.65 0.3
N
48.0 ft2
7 ft 0 in
1 ft 4 in
None
None
9
S
14
Metal Low-E Single
Yes
0.65 0.25
N
10.2 ft2
7 ft 0 in
1 ft 4 in
None
None
10
S
18
Metal Low-E Single
Yes
0.65 0.25
N
22.1 ft2
2 ft 0 in
1 ft 4 in
None
None
11
N
20
Metal Low-E Single
Yes
0.65 0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
N
22
Metal Low-E Single
Yes
0.65 0.3
N
128.0 ft2
10 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
420 ft2 420 ft2
25 ft
9.4 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000305 1782.1 97.77
183.56
.0971
5
3/25/2021 9:42 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COPA
34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
40 kBtu/hr
1200 cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
— Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handier
TOT
OUT QN RLF
Heat Cool
1 Attic 6 95 ft2
Attic
45 ft2 Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heating f X; Jan Feb ki Mar
Apr
Apr
May
May rl Jun 41 Jul
Aug
JXJ�
jXjSep
Oct H Nov
Oct Nov
H Dec
Dec
Venting [ ]Jan Feb X Mar
Jun [ Jul
Aug
Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10 11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 78
78 78 78
78
78
78
78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78
78 78
78
PM 78
78 78
78 78 78
78
78
78
78 78
78
Heating (WD) AM 66
66 66
66 66 68
68
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Bedroom 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
3/25/2021 9:42 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft..
ft2
ft
0.3
Hall 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 lbs/sq.ft. ,
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Toilet
De%ult(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bedroom
Defauit(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Great Room
Default(8 Ibs/s .ft.
ft2
ft
0.3
Hall 1
3/25/2021 9:42 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Detached or multiple -family
2. Detached
b) Return ducts R
6.0
c) AHU location
Garage
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
40.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2226
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.278
14. Heating system: Capacity
34.0
c) Area
7c.
350.3
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery, unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (insulation R-value)
10132.
16. HVAC credits claimed (Performance
Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be comp�tad-lb4ed on installed code compliant features.
Builder
Date:
Address R New Home: t Lot 1 City/FL Zip: Port St. Lucie, FL 34952
3/24/2021 5:50:12 PM EnergyGauge® USA 7.0.00 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Hargrave Residence Builder Name:
Street: Lot 1 Permit Office: St. Lucie County
City, State, Zip: Port St. Lucie, FL , 34952 Permit Number:
Y
U
Owner: Hargrave Residence Jurisdiction: St. Lucie County
w
x
Design Location: FL, Fort Pierce
o
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The Insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinki cover plates walls or cellingr.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
3/24/2021 6:41 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1