HomeMy WebLinkAboutEnergy CodeFORM r,405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 11 Block 1 Waterstone 2020 AGL
Builder Name: ADAMS HOMES
Street: 5416 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1829.9 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1429.50 ft2
b. Frame - Wood, Adjacent
R=13.0 317.53 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Exterior
R=13.0 82.83 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2100.0 sgft.)
Insulation Area
a. Under Attic (Vented) .
R=30.0 2020.00 ft2
6. Conditioned floor area above grade (ft2) 2020
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(202.3 sgft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 404
a. U-Factor: Dbl, U=0.33 147.17 ft2
SHGC: SHGC=0.23 .
b. U-Factor: Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGCng
Area Weighted Average Overhang Depth: 3.216 ft.
D
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.270
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2020.0 sgft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2020.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.100 Total Proposed Modified Loads: 61.44
PASS
Total Baseline Loads: 62.43
I hereby certify that the plans a p ations covered b
Revie of the plans and'SKE
this calculation are in compli . c the Florid gy
specifications covered by this
_.�
Code.
calculation indicates compliance
�'�� `per
with the Florida Energy Code.
(tn, ,���. •,; ;.�a
PREPARED BY:
Before construction is completed
DATE: n2-1 n-?n2 1 Winn Keomany
this building will be inspected for
compliance with Section 553.908
:.
* = #
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Epergy Code.
OWNER/AG
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
2/10/2021 9:04 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPnRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 11 Block 1 Waterstone 20 Bedrooms: 4
User Conditioned Area: 2020
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 11-1
Block/Subd!vision: Waterstone
PlatBook:
Street: 5416 Lugo Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
I/ Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2020 21210
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2020 21210 Yes 1 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 162 ft 0
2020 ft2 ---- 0.37 0 0.63
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2259 ft2 506 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
v #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2020 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2020 ft2 0.11 Wood
80 ft2 0.11 Wood
2/10/2021 9:04 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT RtIMMARY rl-IFf_KI IST RFPnPT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
0
1 E Exterior Concrete Block - Int Insul
Main
4.1 45 6 9
4
424.7 ft2
0
0 0.6
0
2 N Exterior Concrete Block - Int Insul
Main
4.1 8 0 11
10
94.7 ft2
0
0 0.6
0
3 W Exterior Concrete Block - Int Insul
Main
4.1 46 2 11
10
546.3 ft2
0
0 0.6
0
4 S Exterior Concrete Block - Int Insul
Main
4.1 30 9 11
10
363.9 ft2
0
0 0.6
0
5 - Garage Frame - Wood
Main
13 26 10 11
10
317.5 ft2
0
0.23 0.01
0
6 N Exterior Frame - Wood
Main
13 7 11
10
82.8 ft2
0.23 0.6
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 N Insulated
Main
None
.25
3
6 8
20 ft2 .
2 - Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 E 1 Vinyl LoW-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
2 N 6 Vinyl Low-E Double
Yes
0.33 0.31 N
5.0 ft2
6 ft 0 in
1 ft 6 in
None
None
3 N 2 Vinyl Low-E Double
Yes
0.33 0.21 N
32.4 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
4 W 3 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
5 S 4 Metal Low-E Double
Yes
0.55 0.7 N
17.8 ft2
11 ft 4 in
1 ft 0 in
None
None
6 S 4 Vinyl Low-E Double
Yes
0.33 0.23 N
10.7 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
7 S 4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
8 S 4 Vinyl Low-E Double
Yes
0.33 0.23 N
23.2 ft2
11 ft 4 in
0 ft 6 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 593 ft2 593 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000467
2474.5 135.76 254.87
.1409
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ None
Sing] HSPF:8.5
34.6 kBtu/hr
1
sys#1
2/10/2021 9:04 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHFCKI _IST RFPnRT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency,
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 404 ftz
Main
101 ftZ Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
He H Jan H Feb
Mar
Mar
HX
Apr
Apr
May X Jun Jul
May Jun Jul
Auge
AuSeP
Oct
Oct
Nov
Dec
Dec
H
Ventin Jan Feb
Mar
[X] Apr [
May [ Jun [ Jul
[ Aug
Se [
Oct
XNov
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78t
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68,
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
2/10/2021 9:04 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM Fg05-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
5416 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1429.50 ft2
b. Frame - Wood, Adjacent
R=13.0
317.53 ft2
3. Number of units, if multiple family
1
c. Frame - Wood, Exterior
R=13.0
82.83 ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11..Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2020.00 ft2
6. Conditioned floor area (ft2)
2020
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
147.17 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 404
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
5.00 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average Overhang Depth:
3.216 ft.
Area Weighted Average SHGC:
0.270
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap: 40 gallons
EF:0.94
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 2020.00 ft2
Credits (Performance method)
Pstat
b. N/A
R= ft2
c. N/A
R= ft2
Y
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/10/2021 9:04 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1