FL #FL17022-R9
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
David Eng
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL17022_R9_COI_26ga_VMAX_plywood.pdf
Referenced Standard and Year (of Standard)Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
5/4/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2b7ZB0qjsB2joMv1ul8qwLyA%3d%3d 2/3
Product Approval Method Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/16/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summary of Products
FL #Model, Number or Name Description
17022.1 01: 26ga VMax on Plywood 26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-228
Other: Refer to evaluation report.
Installation Instructions
FL17022_R9_II_26ga_VMAX_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R9_AE_26ga_VMAX_plywood.pdf
Created by Independent Third Party: Yes
17022.2 02: 032 Aluminum VMax on Plywood Nominally 0.032" aluminum (or thicker) VMax 5V panel with
21" coverage on 15/32" (min) plywood or 3/4" (min) thick
wood plank.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
Other: Refer to evaluation report.
Installation Instructions
FL17022_R9_II_032_VMAX_21in_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R9_AE_032_VMAX_21in_plywood.pdf
Created by Independent Third Party: Yes
17022.3 03: 26ga VMax on Plywood 26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank. Option for fasteners in
the flats and in the ribs.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-114.25
Other: Refer to evaluation report.
Installation Instructions
FL17022_R9_II_26ga_VMAX_plywood_flats.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R9_AE_26ga_VMAX_plywood_flats.pdf
Created by Independent Third Party: Yes
17022.4 04: 26ga CorMax on Plywood 26ga (min) CorMax corrugated panel with 29.5" coverage on
15/32" (min) plywood or 3/4" (min) thick wood plank.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161
Other: Refer to evaluation report.
Installation Instructions
FL17022_R9_II_26ga_CorMax_Plywood_HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R9_AE_26ga_CorMax_Plywood_HVHZ.pdf
Created by Independent Third Party: Yes
17022.5 05: 26ga CorMax on Battens 26ga (min) CorMax corrugated panel with 29.5" coverage on
2x4 (min) battens.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161
Other: Refer to evaluation report.
Installation Instructions
FL17022_R9_II_26ga_CorMax_Battens.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R9_AE_26ga_CorMax_Battens.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
5/4/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2b7ZB0qjsB2joMv1ul8qwLyA%3d%3d 3/3
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts: